BRUCE MAIL is a 1983 offshore supply vessel. The Coast Guard has recorded 15 inspections since 2020, most recently in September 2025, along with 15 deficiencies — 9 with no resolution recorded —, 2 operational controls, 1 with no removal date recorded and 1 casualty investigation in 2011.

Records from 2011 to 2025. Most recent: operational control imposed, 21 September 2025.

Built
1983
Last inspected
20 September 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls, the recorded names, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 September 2025
…with no type recorded1
…past their stated due date1
Operational controls 1 with no removal date recorded
Years with a record 6 calendar years (2020–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8301072
Flag
VANUATU
Maury page id
psix-55041

Documentation record

Tonnage as PSIX records it1189 - Convention (Subpart B), Gross Ton
1696 - Dead Weight, Metric Ton
1710 - Displacement, Metric Ton
356 - Convention (Subpart B), Net Ton
424 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

15 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each; 2 operational controls with the dates imposed and removed; 1 other recorded name, with years; 1 casualty investigation, with date and classification; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

20 September 2025 Appeal · CCSSC Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8237378
20 September 2025 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8237953
21 August 2025 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8219794
16 August 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8210546
8 February 2025 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8076315
1 August 2024 PSC B · CCSSC Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7972337
21 January 2024 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7851226
17 July 2023 CCSSC Examination · PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7743526
16 January 2023 PSC B · Deficiency Check · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7621863
12 July 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7522241
10 July 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7499918
10 January 2022 PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7377716
19 June 2021 PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7229382
9 December 2020 PSC A
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7103608
24 June 2020 Loadline Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6985575

Deficiency record · 15

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 20 September 2025 No resolution recorded
The Company should identify potential emergency shipboard situations, and establish procedures to respond to them. Since the emergency diesel generator is located in the main machinery space, the SMS does not address how to respond to a loss of power in the event of a machinery space casualty (fire, flooding, etc.) that renders the emergency diesel generator inaccessible. This causes a single point of failure that presents an unacceptable risk to the crew, vessel, and the environment. An external ISM audit is required. 74 SOLAS (24) IX/3.1 ISM Code 8.1 Code 30bc
Action required: 30 - Ship detained
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 20 September 2025 No resolution recorded
The Company should ensure that all personnel involved in the Company's SMS have adequate understanding of the relevant rules, regulations, codes, and guidelines. The crew did not identify any issues with the emergency source of power being located in the main machinery space nor that it is impossible to stop the passage of smoke and flame from the galley or accommodation spaces to the bridge. 74 SOLAS (24)IX/3.1 ISM Code 8.1 Code 17bc
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 20 September 2025 No resolution recorded
The emergency source of electrical power, associated transforming equipment...and emergency switchboard should be located above the uppermost continuous deck and should be readily accessible from the open deck. PSCO observed emergency generator located in the main machinery space below the uppermost continuous deck. CCSSC (1997) 2.34 Code 17bc
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 20 September 2025 No resolution recorded
The emergency source of electric power, associated transforming equipment, if any, and emergency switchboard should be located above the uppermost continuous deck and should be readily accessible from the open deck. The emergency diesel generator is located in the main machinery space below the uppermost continuous deck. CCSSC (1997) 2.34 Code 17bc
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 20 September 2025 No resolution recorded
Ventilation systems of each of the following groups of spaces should be entirely separated from each other: machinery spaces; galley; cargo spaces; and accommodation spaces and the control spaces. The ventilation system for the galley is not separated from the accommodation spaces or the navigation bridge as required by CCSSC. Thus, it is not possible to prevent the passage of smoke and flame between the galley, the accommodation spaces, and the bridge. CCSSC (1997) 3.16.6.1 Code 17bc
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 20 September 2025 No resolution recorded
Subject to provisions of 3.16.1.2 and 3.16.1.3, the fire safety requirements of bulkheads, decks, doors, and stairways should, as far and as practicable and reasonable in the opinion of the Administration, comply with the applicable requirements of 1974 SOLAS Convention for such bulkheads, doors, and stairways. A solid wooden door is the only boundary separating the accommodation spaces (on deck 1), also fitted with solid wooden doors, from the stairway leading to the navigation bridge (on deck 2). No doors separate the accommodation spaces from the galley (on the main deck). This design represents an unmitigated fire risk. CCSSC (1997) 3.16.1.1 74 SOLAS Cons. II-2/2 Code 17bc
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 20 September 2025 No resolution recorded
Paints, varnishes, and other finishes used on exposed interior surfaces should not offer an undue fire hazard in the judgment of the Administration and should not be capable of producing excessive quantities of smoke. Wood finishes are on the walls of the accommodation spaces, and the crew was unable to provide evidence that they will not pose an undue fire hazard or produce excessive quantities of smoke. CCSSC (1997) 3.16.3.2 Code 17bc
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 20 September 2025 No resolution recorded
Life-saving appliances required by this chapter should comply with the technical specifications of the LSA Code. Except as provided by this section, all rescue boats shall comply with paragraphs 4.4.1 to 4.4.7.4. Each lifeboat shall be fitted with a permanently affixed approval plate endorsed by the Administration or its representative, containing at least the following items: manufacturer’s name and address; lifeboat model and serial number; month and year of manufacture; number of persons the lifeboat is approved to carry; and the approval information required under paragraph 1.2.2.9. Each production lifeboat shall be provided with a certificate of declaration of conformity. The rescue boat does not have the affixed approval plate nor a certificate of declaration of conformity. CCSSC (1997) 4.3.1 LSA Code 5.1.1.1 LSA Code 4.4.1.2 Code 17bc
Action required: 17 - Rectify deficiencies prior to departure
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 September 2025 No resolution recorded
The ring, lines, and letters...shall be permanently marked on the side of the ship to the satisfaction of the Administration. The deck line was painted but not permanently affixed. ICLL I/8 Code 40bc
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 21 September 2025 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 January 2023 Resolved
The emergency fire pump, sea suction, and other valves shall be operable from outside the compartment containing the main fire pump and in a position not likely to be cut off by fire in the compartment. PSCOs observed both fire pumps in the same space (eng. room). CCSSC 3.3.10.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2023
Resolution: Ship owner provided a diesel emergency portable fire pump. Fire pump tests were verified to the satisfaction of the attending surveyor from class.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 16 January 2023 Resolved
In all such ships, fire control plans shall be kept up to date. PSCO's discovered no fire pumps labeled on the fire control plan; plan incomplete. CCSSC 3.13.2
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2023
Resolution: The fire plan has been corrected to the satisfaction of the attending surveyor. (Main fire pump and Emergency portable fire pump label updated on Fire Control Plan)
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo Securing Manual
Issued 16 January 2023 Resolved
Cargo, cargo units, and cargo transport units shall be loaded, stored and secured throughout the voyage in accordance with the cargo securing manual approved by the administration. PSCOs observed no guidelines for securing vehicles on board the vessel. 74 SOLAS 2020 VII/5
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 18 January 2023
Resolution: Cargo Securing Manual has been updated by DPA (section 5.2.3 Loading, Stowage&Securing Vehicle Instruction) and verified to the satisfaction of attending surveyor.
01 - Certificates & Documentation › 011 - Ships Certificates › International Oil Pollution Prevention (IOPP)
Issued 10 July 2022 Resolved
In every case, The Administration shall fully Guarentee the completeness and efficiency of the survey and shall undertake to ensure the nesessary arrangements to satisfy this obligation. Incorrect equipment identified on IOPP Supplement. MARPOL I/6.3.4
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2022
Resolved 12 July 2022
Resolution: Operator sent updated IOPP supplement with correct separating/filtering equipment listed.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 10 July 2022 Resolved
The Surveys referred to in 1.10.1 should include the following items...lifesaving appliances and arrangements. Life Raft Equipment improperly identified on the CCSSC Supplement. CCSSC 1.10.2.2
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2022
Resolved 2 August 2022
Resolution: Received correspondence confirming updated record of equipment.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 9 December 2020 Resolved
Every oil fuel suction pipe from a storage, settling, or daily service tank situated above the double bottom shall be fitted with a cock or valve capable of being closed from outside the space concerned in the event of a fire in the space in which they are situated. Day tank remote closing valve found inoperable. SOLAS 74(Unamended) II-2/Reg 54(c)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 December 2020
Resolved 10 December 2020
Resolution: Received satisfactory evidence attesting to the proper function of the emergency fuel shut off for the day tanks.

Casualty record · 1

2 May 2011Routine · role: Involved in a Marine Casualty · activity 4028955
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

M/V ELSA LEIGH (2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.