Records from 1984 to 2008. Most recent: inspection, 4 February 2008.
Inspection history · 56
4 February 2008
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3141672
2 February 2008
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3141447
6 October 2007
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3075755
12 July 2007
Damage Survey · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2993367
26 June 2007
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2974907
17 August 2006
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2751279
31 May 2006
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2666272
14 April 2006
Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2624114
28 March 2006
COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2610584
14 February 2006
Hull Examination · Examination of Repairs
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2584045
29 July 2005
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2447386
24 May 2005
Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2328378
18 June 2004
Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2098087
23 January 2004
Examination of Repairs · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1991261
25 June 2003
Re-Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1816634
5 September 2002
Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1670291
16 July 2002
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1636497
18 January 2002
Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1484883
18 May 2001
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1432510
26 June 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1430885
1 November 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1470237
8 July 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1433518
21 October 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 148723
1 July 1998
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 793989
19 May 1998
COI Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126034
23 October 1997
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1116838
9 September 1997
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 789102
12 August 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 783166
1 August 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1084292
18 July 1996
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1089485
2 October 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874782
28 June 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1190555
23 May 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184139
20 September 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1180728
13 July 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176008
2 March 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854466
24 February 1994
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1164315
13 July 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841197
17 July 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1136469
14 May 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1270531
14 May 1991
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1255733
11 January 1991
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1302622
16 May 1990
Deficiency Check · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 911304
6 November 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 911625
17 May 1989
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1041586
16 November 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1205683
3 November 1988
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 889156
16 June 1988
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1202019
5 November 1987
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330218
24 June 1987
Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1330511
14 April 1987
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1329849
10 October 1986
Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1012580
2 July 1986
Deficiency Check · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1012737
12 November 1985
Credit Drydock
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 987297
25 July 1985
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1295408
15 October 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1284018
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 October 2007
Resolved
Make proper repairs to the steering system and prove proper operation to the satisfaction of an attending marine inspector prior to the carriage of passengers. Actual cause of loss of steering has yet to be determined. Speculated to be from air in the hydraulic line.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 October 2007
Resolved 17 October 2007
Engineering › Steering Gear System › Rudder Bearing
Issued 6 October 2007
Resolved
Make proper repairs (significant leak) to the rudder post packing gland to the satisfaction of an attending marine inspector and conduct a sea trial prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2007
Resolved 17 October 2007
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 12 July 2007
Resolved
Prove proper operation of MDE
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2007
Resolution: Verified proper operation of the MDE. No discerpancies noted.
Lifesaving › Hand Flares › Quantity
Issued 26 June 2007
Resolved
Obtain 3 red hand flares.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2007
Resolved 27 June 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 26 June 2007
Resolved
Mount fire extinguisher in forward console.
Due 29 June 2007
Resolved 27 June 2007
Communications › Radio Communications › EPIRB
Issued 26 June 2007
Resolved
Replace EPIRB hydrostatic release.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2007
Resolved 27 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 June 2007
Resolved
Replace 2 bilge high level alarm indicators and prove proper operation prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2007
Resolved 27 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 June 2007
Resolved
Label bilge high level alarms at the console.
Due 29 June 2007
Resolved 27 June 2007
Construction/Loadline › Hull › Keel
Issued 17 August 2006
Resolved
Vessel sustained damage on keel (aft of midships) causing minor delamination. Vessel must submit a repair proposal detailing the extent and procedures to affect proper repairs to the satisfaction of an attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2006
Resolved 19 September 2006
Engineering › Bilge Water Management System
Issued 25 June 2003
Resolved
Renew wasted sea valve & valve leading through watertight bulkhead for fixed bilge pumping system. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Engineering › Bilge Water Management System › Piping
Issued 25 June 2003
Resolved
Remove oil from bilges in engineroom and demonstrate proper operation of bilge pumping system.
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Documentation › Certificates/Documents › FCC SSL
Issued 25 June 2003
Resolved
Provide proof of valid FCC Radio Safety Cert.
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Engineering › Bilge Water Management System › Pump
Issued 25 June 2003
Resolved
Renew portable bilge pump.
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 25 June 2003
Resolved
Tighten shaft packing gland.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Engineering › Bilge Water Management System › Valve
Issued 25 June 2003
Resolved
Renew wasted bilge suction valve for fuel tank space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Engineering › Bilge Water Management System › Valve
Issued 25 June 2003
Resolved
Permanently mount electric bilge pump and install a positive shutoff valve in the discharge line.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Construction/Loadline › Penetrations › Gasket
Issued 25 June 2003
Resolved
Adjust Bowmar hatches so gaskets provide a watertight seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Gaskets renewed.
Engineering › Bilge Water Management System
Issued 25 June 2003
Resolved
Prove proper operation of fixed bilge pumping system. LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 June 2003
Resolved 25 June 2003
Resolution: Corrected.
Engineering › Bilge Water Management System › Strainer
Issued 25 June 2003
Resolved
Install proper size strainers on bilge suction lines.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2003
Resolved 15 July 2003
Resolution: Corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 16 July 2002
Resolved
Provide proof that fixed fire fighting system has been serviced.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 July 2002
Resolved
Label location of fire extinguisher on upper deck. LEGACY COMPONENT DESC: Marking
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Lifesaving › Lifebuoys
Issued 16 July 2002
Resolved
Provide (4) new floating paddles, 4 feet in length for life floats and stencil vessel's name on paddles.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance
Issued 16 July 2002
Resolved
Replace cloudy lens on starboard navigation light. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Communications › Alarms/Indicators
Issued 16 July 2002
Resolved
Replace weak, corroded high level alarms at upper and lower operating stations. LEGACY COMPONENT DESC: High Water Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 16 July 2002
Resolved
Remove dead-end wires in Head and forward compartment. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Electrical › Electrical Distribution System (service)
Issued 16 July 2002
Resolved
Replace wire nuts with pressure connectors in way of water pressure pump. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 July 2002
Resolved
Renew first aid kit in accordance with 46 CFR 160 and 46 CFR 184. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Fire Fighting › Remote Fuel Shutoff
Issued 16 July 2002
Resolved
Properly label emergency fuel shut offs.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected
Documentation › Markings/Placards
Issued 16 July 2002
Resolved
Provide and post PFD donning placard.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected
Lifesaving › Lifejacket/PFD (Type I)
Issued 16 July 2002
Resolved
Provide (2) adult sized PFDs to replace those failed by the Marine Inspector. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected
Lifesaving › Lifebuoys
Issued 16 July 2002
Resolved
Provide a corrosion resistant metallic clip for ring buoy and attach waterlight. Also provide a 60 ft painter for ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 16 July 2002
Resolved
Renew wasted fire extinguisher bracket in way of lower operating station. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Navigation › Piloting/Steering
Issued 16 July 2002
Resolved
Provide navigation publications as required by 46 CFR183, 46 CFR 420, 33 CFR 84 and 72 ColRegs. (CG Light List, Coast Pilot, Charts, Navigation Rules) LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 August 2002
Resolved 5 September 2002
Resolution: Corrected.
Accommodation/Occupational Safety › Occupational Safety
Issued 16 July 2002
Resolved
Install mesh or courses between the top rail and bulwark so that no space is greater than 4 inches in accordance with 46 CFR 177.900 and MSO Miami Bulletin 02-001. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2002
Resolved 25 June 2003
Resolution: Corrected.
Lifesaving
Issued 26 June 2000
Resolved
Replace hydrostatic release for EPIRB.
Condition: Unknown
Due 26 June 2000
Resolved 7 July 2000
Fire Fighting
Issued 26 June 2000
Resolved
Replace 1 BII and service all portable & fixed extinguishers.
Condition: Unknown
Due 30 June 2000
Resolved 7 July 2000
Construction/Loadline
Issued 26 June 2000
Resolved
Install indicator light for each high water alarm.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Navigation
Issued 26 June 2000
Resolved
Repair stbd running light. No evening/night ops until repaired.
Condition: Unknown
Due 30 June 2000
Resolved 7 July 2000
Engineering
Issued 26 June 2000
Resolved
Repair packing gland in fuel tank compt.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Navigation
Issued 1 November 1999
Resolved
Repair/renew rudder post guide in steering lazarette.
Condition: Unknown
Due 3 November 1999
Resolved 8 November 1999
Construction/Loadline
Issued 1 November 1999
Resolved
Re-tab area in stbd side head @ base of oter shell @ deck intersection.
Condition: Unknown
Due 3 November 1999
Resolved 8 November 1999
Accommodation/Occupational Safety
Issued 1 November 1999
Resolved
Repair hand rails, port & stbd side.
Condition: Unknown
Due 3 November 1999
Resolved 8 November 1999
Fire Fighting
Issued 8 July 1999
Resolved
Provide plan for ventilation closures.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Fire Fighting
Issued 8 July 1999
Resolved
Provide one BI extinguisher or shift one BII to the operating station.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Lifesaving
Issued 8 July 1999
Resolved
Provide log for emergency drills.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Lifesaving
Issued 8 July 1999
Resolved
Provide 3 orange smoke & 3 red signal flares.
Condition: Unknown
Due 30 July 1999
Resolved 6 August 1999
Lifesaving
Issued 8 July 1999
Resolved
Provide 6 lights for PFDs.
Condition: Unknown
Due 30 July 1999
Resolved 6 August 1999
Lifesaving
Issued 19 May 1998
Resolved
Renew hydrostatic release and battery for EPIRB.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Renew lines for waterlights on both lifefloats.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Navigation
Issued 19 May 1998
Resolved
Demonstrate proper operation of SSB radio.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Lifesaving
Issued 19 May 1998
Resolved
Re-stencil name of vessel and capacity on stbd lifefloat.
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Documentation
Issued 19 May 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 May 1998
Resolved 19 May 1998
Electrical
Issued 12 August 1997
Resolved
Properly mount light in engineroom.
Condition: Unknown
Due 20 August 1997
Resolved 9 September 1997
Fire Fighting
Issued 12 August 1997
Resolved
Perform annual servicing on all portable fire extinguishers.
Condition: Unknown
Due 20 August 1997
Resolved 9 September 1997
Lifesaving
Issued 12 August 1997
Resolved
Renew retro-reflective tape on 14 adult PFD's.
Condition: Unknown
Due 20 August 1997
Resolved 9 September 1997
Lifesaving
Issued 12 August 1997
Resolved
Repair waterlight for port lifefloat.
Condition: Unknown
Due 20 August 1997
Resolved 9 September 1997
Lifesaving
Issued 12 August 1997
Resolved
Renew retro-reflective tape on both lifefloats and stencil paddles with vessel's name.
Condition: Unknown
Due 20 August 1997
Resolved 9 September 1997
Lifesaving
Issued 12 August 1997
Resolved
Install retro-reflective tape on ring buoy.
Condition: Unknown
Due 20 August 1997
Resolved 9 September 1997
Lifesaving
Issued 18 July 1996
Resolved
Renew expired waterlights on 29 adult PFD's and 5 child PFD's.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Fire Fighting
Issued 18 July 1996
Resolved
Perform annual servicing on all 3 B-II fire ext. and B-I fire ext.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Navigation
Issued 18 July 1996
Resolved
Install proper size key for emer. tiller.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Engineering
Issued 18 July 1996
Resolved
Re-stencil emer. fuel shutoff.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996
Resolved
Post emer. checkoff list.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996
Resolved
Install new retro-reflective tape on 7 adult PFD's and 5 child PFD's.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 18 July 1996
Resolved
Renew 6 expired orange flares and 3 expired red flares.
Condition: Unknown
Due 18 July 1996
Resolved 18 July 1996
Lifesaving
Issued 23 May 1995
Resolved
Repair securing snaps on all lifejackets as necessary.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Lifesaving
Issued 23 May 1995
Resolved
Replace defective Personal Marker Lights on 9 adult lifejackets.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Navigation
Issued 23 May 1995
Resolved
Demonstrate proper operation of SSB radio._x001C_ Limited to voyages not more than 20 miles from a harbor of safe refuge until completed.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Lifesaving
Issued 23 May 1995
Resolved
Provide waterlight for ringbuoy.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Lifesaving
Issued 23 May 1995
Resolved
Capacity limited to 32 Adults and 4 children additional approved lifejackets are placed on board.
Condition: Unknown
Due 23 May 1995
Resolved 23 May 1995
Navigation
Issued 13 July 1994
Resolved
Repair auxiliary steering system.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Lifesaving
Issued 13 July 1994
Resolved
Replace line on ring buoy.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Lifesaving
Issued 13 July 1994
Resolved
Replace painter on port side lifefloat.
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Construction/Loadline
Issued 24 February 1994
Resolved
Tighten loose connections on bilge suction manifold.
Condition: Unknown
Due 3 March 1994
Resolved 3 March 1994
Engineering
Issued 25 July 1985
Resolved
THE FUEL FILTER FOR THE MAIN ENGINE IS A RACOR FILTER WITH THE CLEAR PLASTIC BOWL AND IT DOES NOT HAVE THE REQUIRED METAL BOWL TO PROTECT THE PLASTIC PORTION OF THE FILTER.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Accommodation/Occupational Safety
Issued 25 July 1985
Resolved
THE RAILINGS AROUND THE BOW OF THE VESSEL HAVE NO RUNGS AND ARE 30 INCHES HIGH. THIS AREA IS ACCESSIBLE TO PASSENGERS AND MUST HAVE A MAXIMUM RUNG SPACING OF 12 INCHES.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Documentation
Issued 25 July 1985
Resolved
THE CERTIFICATE OF INSPECTION, STABILITY LETTER, AND RADIO LICENSES ARE NOT POSTED. THERE ARE NO POSTED EMERGENCY INSTRUCTIONS TO THE PASSENGERS.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985