Records from 1984 to 2015. Most recent: casualty investigation, 15 January 2015.
Electrical › Electric Generation Source (service) › Generator
Issued 31 October 2011
Resolved
Generator operation is prohibited while passengers are on board until proven satisfactory to a USCG inspector.
Action required: 705 - Other - as specified
Due 31 October 2011
Resolved 25 April 2012
Electrical › Electrical Distribution System (service) › Panelboard
Issued 31 October 2011
Resolved
Bridge A/C panel must remain de-energized and locked out until electrical plans are approved by MSC.
Action required: 705 - Other - as specified
Due 31 October 2011
Resolved 25 April 2012
Stability › Watertight Integrity › General
Issued 31 October 2011
Resolved
Passenger capacity limited to not more than 49 until water tight integrity of bulkheads is proven satisfacotry.
Action required: 705 - Other - as specified
Due 31 October 2011
Resolved 8 May 2012
Engineering › Bilge Water Management System › Pump
Issued 31 October 2011
Resolved
Install indicator lights to indicate when automatic bilge pumps are operating.
Action required: 705 - Other - as specified
Due 22 November 2011
Resolved 8 May 2012
Engineering › Fuel Oil Service System › Piping
Issued 31 October 2011
Resolved
Fuel fill to be relocated outside of the accommodation space prior to June 2012
Action required: 705 - Other - as specified
Due 30 November 2013
Resolved 14 December 2012
Fire Fighting › Structural - B Class Divisions › Windows
Issued 19 September 2008
Resolved
Windows #2 and #4 form the stern forward on the portside are cracked.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 September 2008
Resolved 26 September 2008
Resolution: Windows were replaced witrh new ones, all sat.
Engineering › Fuel Oil Service System › Gauge
Issued 19 September 2008
Resolved
Starboard MDE oil pressure gauge on the bridge was inop
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 September 2008
Resolved 26 September 2008
Resolution: MDE oil pressure gauge operational, all sat.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 6 June 2006
Resolved
Provide current copy of Nav Rules.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 25 July 2006
Resolution: Witnessed current copy of Nav Rules.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 6 June 2006
Resolved
Prove current servicing of fire extinguishers.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 28 July 2006
Resolution: Received proof of purchase of new portable extinguisher.
Documentation › Markings/Placards › Lifejacket Placard
Issued 6 June 2006
Resolved
Provide valid donning placard.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 25 July 2006
Resolution: Witnessed new donning placard.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 6 June 2006
Resolved
Prove approval of MSD.
Action required: 705 - Other - as specified
Due 6 July 2006
Resolved 25 July 2006
Resolution: Received statement from manufacturer.
Documentation › Certificates/Documents › FCC SSL
Issued 7 September 2005
Resolved
FCC SSL not available, Radio Safety Certificate not available & expired.
Action required: 705 - Other - as specified
Due 23 September 2005
Resolved 23 September 2005
Resolution: Owner provided proof of application for FCC SSL. Contacted FCC to ensure SSL was valid. Owner showed valid Radio Safety Certificate. All sat.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 7 September 2005
Resolved
Senior Deck Hand not designated in writing.
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 9 September 2005
Resolution: Owner posted written senior deckhand designation in pilothouse.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 7 September 2005
Resolved
Passenger count not available.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 9 September 2005
Resolution: Owner mounted mailbox on pier.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 7 September 2005
Resolved
Tidal Current tables not onboard
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 9 September 2005
Resolution: Owner purchased tidal current table.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 September 2005
Resolved
No rail on bow.
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 7 October 2005
Resolution: Owner fabricated bow rail all, inspected sat.
Documentation › Markings/Placards › Capacity Marking
Issued 7 September 2005
Resolved
Upper deck not marked for max capacity.
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 8 September 2005
Resolution: Corrected on the spot. Owner labeled ladder.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 September 2005
Resolved
Provide 5 servicable life jackets.
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 9 September 2005
Resolution: Owner purchased 5 new PFD''s.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005
Resolved
In the forpeak conduct adequate repairs to prevent leakage in seams identified by marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 9 September 2005
Resolution: Seams filled with oakum and caulk.
Construction/Loadline › Hull › Hull Plating
Issued 7 September 2005
Resolved
In lazarette conduct adequate repairs to prevent leakage to seams identified by Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 9 September 2005
Resolution: Seams sealed with oakum & caulk, tested with hose all sat.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 7 September 2005
Resolved
Auto shutdown inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 9 September 2005
Resolution: Owner contacted manufacturer to troubleshoot. Replaced wiring test sat.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 September 2005
Resolved
Access to panel blocked.
Action required: 705 - Other - as specified
Due 8 October 2005
Resolved 9 September 2005
Resolution: Owner moved drink equipment.
Engineering › Fuel Oil Service System › Piping
Issued 7 September 2005
Resolved
Stbd eng fuel return line hose fitting on the tank end removed & replaced with hose clamp.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 9 September 2005
Resolution: Owner had new hose made and installed sat.
Fire Fighting › Fire Pumps › Impeller
Issued 7 September 2005
Resolved
Fire/Bilge pump inop.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 October 2005
Resolved 9 September 2005
Resolution: Hole in piping found and repaired, test sat.
Construction/Loadline › Structures › Deck Plating
Issued 10 September 2004
Resolved
Replace overhead deck beam in #2 compartment aft of the hatch.
Due 10 October 2004
Resolved 29 September 2004
Resolution: Replaced beam.
Construction/Loadline › Structures › Deck Plating
Issued 10 September 2004
Resolved
Replace overhead deck beams in laz compartment aft STBD side.
Due 10 October 2004
Resolved 29 September 2004
Resolution: Replaced beams.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 10 September 2004
Resolved
Clean threads on lids of fuel shut offs, replace as needed.
Condition: Improper/Lack of Maintenance
Due 10 October 2004
Resolved 29 September 2004
Resolution: Replaced access covers for fuel shut offs.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 10 September 2004
Resolved
Provide placard for [name withheld] lifejackets.
Condition: Improper Installation
Due 10 October 2004
Resolved 29 September 2004
Resolution: Provided placard.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 10 September 2004
Resolved
Provide a new copy of emergecy procedures.
Condition: Improper/Lack of Maintenance
Due 10 October 2004
Resolved 29 September 2004
Resolution: Provided new copy.
Engineering › Bilge Water Management System › Manifold
Issued 10 September 2004
Resolved
Label high bilge alarms.
Condition: Improper Installation
Due 10 October 2004
Resolved 29 September 2004
Resolution: Labeled alarms.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 September 2004
Resolved
Secure battery boxes from sliding.
Condition: Improper Installation
Due 10 October 2004
Resolved 29 September 2004
Resolution: Secured boxes.
Lifesaving › Thermal Protective Aids
Issued 10 September 2003
Resolved
Install Retro reflective tape on life ring. LEGACY COMPONENT DESC: Life ring
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 9 October 2003
Resolution: Installed retro.
Construction/Loadline › Hull
Issued 10 September 2003
Resolved
Repair seam in rudder compartment. LEGACY COMPONENT DESC: Side Shell
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 9 October 2003
Resolution: Reparied seam.
Engineering › Bilge Water Management System
Issued 10 September 2003
Resolved
Install gate valve in 2nd compartment for bilge pump. LEGACY COMPONENT DESC: Valve
Condition: Placed in Improper Service
Due 10 October 2003
Resolved 9 October 2003
Resolution: Installed gate valve.
Engineering › Fuel Oil Storage/Transfer System
Issued 10 September 2003
Resolved
Mark direction of opening/closing for fuel shut off valves. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 9 October 2003
Resolution: Marked direction.
Navigation › Piloting/Steering
Issued 10 September 2003
Resolved
Repair compass light/ replace light bulb. LEGACY COMPONENT DESC: Gyro Compass
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 9 October 2003
Resolution: Repaired light.
Stability › Watertight Integrity
Issued 10 September 2003
Resolved
Ensure watertight intergrity of forward bulkhead of engine room, starboard side. LEGACY COMPONENT DESC: Bulkhead
Condition: Improper/Lack of Maintenance
Due 10 October 2003
Resolved 9 October 2003
Resolution: Repaired bulkhead crack.
Fire Fighting › Fire Pumps
Issued 10 September 2003
Resolved
Prove proper operation of fire pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 September 2003
Resolution: Fire pump working properly.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 26 September 2002
Resolved
Provide proof of annual servicing of portable and fixed fire fighting equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 October 2002
Resolution: Proof of servicing for portable and fixed fire fighting equipment was provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 26 September 2002
Resolved
Repair alarm at operating station for fixed fire fighting system. LEGACY COMPONENT DESC: Operating Controls
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: Alarm replaced at operating station, working correctly.
Construction/Loadline › Hull
Issued 26 September 2002
Resolved
Repair butt block leak in #2 compartment STBD side. LEGACY COMPONENT DESC: Bottom Plating
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 October 2002
Resolution: Butt block leak repaired.
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2002
Resolved
Replace outdated charts #12312 and #12314.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2002
Resolution: Replaced outdated charts.
Construction/Loadline › Structures
Issued 26 September 2002
Resolved
Repair deck frame fwd of hatch #1 compartment. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Due 24 November 2002
Resolved 8 October 2002
Resolution: Deck frame repaired
Construction/Loadline › Hull
Issued 26 September 2002
Resolved
Repair tonnage brace frame #4 in #1 compartments. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 24 November 2002
Resolved 8 October 2002
Resolution: Tonnage brace repaired.
Navigation › Collision/Grounding Avoidance
Issued 26 September 2002
Resolved
Repair broken bridge window. LEGACY COMPONENT DESC: Navigation Bridge Visibility
Condition: Improper/Lack of Maintenance
Due 24 November 2002
Resolved 8 October 2002
Resolution: Broken window replaced.
Construction/Loadline › Structures
Issued 26 September 2002
Resolved
Caulk foward E/R bulkhead through hole cable runs. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper Installation
Due 24 November 2002
Resolved 8 October 2002
Resolution: Cable runs caulked.
Engineering › Bilge Water Management System
Issued 26 September 2002
Resolved
Repair bilge pump discharge line in E/R. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 24 November 2002
Resolved 8 October 2002
Resolution: Bilge line replaced.
Electrical › Electrical Distribution System (service)
Issued 26 September 2002
Resolved
Provide protection for wiring in E/R bus. LEGACY COMPONENT DESC: Bus Bar Connection
Condition: Improper Installation
Due 24 November 2002
Resolved 8 October 2002
Resolution: Protection provided for wiring in E/R bus.
Fire Fighting › Structural - A Class Divisions
Issued 26 September 2002
Resolved
Refasten insulation in E/R overhead. LEGACY COMPONENT DESC: Bulkheads - Machinery Spaces
Condition: Improper/Lack of Maintenance
Due 24 November 2002
Resolved 8 October 2002
Resolution: Insulation refastened.
Electrical
Issued 11 June 2001
Resolved
REMOVE DEAD-END WIRES ASSOCIATED WITH THE THE OLD GENERATOR.
Condition: Unknown
Due 2 July 2001
Resolved 27 July 2001
Fire Fighting
Issued 11 June 2001
Resolved
VESSEL's GENERATOR IS TO BE INTERGRATED INTO THE VESSEL's FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 2 July 2001
Resolved 27 July 2001
Fire Fighting
Issued 11 June 2001
Resolved
LABEL FUEL SHUT-OFF ON STARBOARD SIDE.
Condition: Unknown
Due 2 July 2001
Resolved 27 July 2001
Documentation
Issued 11 June 2001
Resolved
NUMBER OF PASSENGERS NOT SPECIFIED FOR THE UPPER DECK IN THE STABILITY LETTER. PROVIDE VESSEL FOR SIMPLIFIED STABILITY TEST PRIOR TO 02 JUL 2001 AND UNTIL THAT TIME THE NUMBER OF PASSENGER ARE REDUCED TO NO MORE THAN 37 ON THE UPPER DECK.
Condition: Unknown
Due 2 July 2001
Resolved 27 July 2001
Engineering
Issued 11 June 2001
Resolved
PRIOR TO A REMOTE SHUTDOWN BEING INSTALLED FOR THE VESSELS GENERATOR, THE THE GENERATOR IS NOT TO BE USED WHILE PASSENGERS ARE ON BOARD OR HAVE ACCESS TO THE VESSEL.
Condition: Unknown
Due 2 July 2001
Resolved 27 July 2001
Accommodation/Occupational Safety
Issued 30 August 2000
Resolved
REPLACE BROKEN WINDOW LOCATED PORT SIDE DINING AREA, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 September 2000
Resolved 1 November 2000
Engineering
Issued 30 August 2000
Resolved
REPAIR RAW WATER LEAK ON OUTBOARD SIDE OF PORT ENGINE.
Condition: Unknown
Due 3 September 2000
Resolved 6 September 2000
Accommodation/Occupational Safety
Issued 30 August 2000
Resolved
REPLACE BROKEN WINDOWS, LOCATED AFT PORT SIDE DINING AREA, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 30 August 2000
Resolved 6 September 2000
Navigation
Issued 30 August 2000
Resolved
REPLACE OUT OF DATE CHARTS FOR CERTIFICATED ROUTE.
Condition: Unknown
Due 3 September 2000
Resolved 6 September 2000
Construction/Loadline
Issued 18 July 2000
Resolved
EFFECT PERMANENT REPAIRS TO LEAKING SEAM IN WAY STARBOARD SHAFT LOG AND ADJOPINING BOTTOM PLANKING.
Condition: Unknown
Due 30 November 2000
Resolved 24 April 2001
Construction/Loadline
Issued 18 July 2000
Resolved
PRIOR TO OPERATION/CARRYING PASSENGERS FOR HIRE, PROVIDE VESSEL FOR UNDERWAY EXAM.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Navigation
Issued 12 June 1998
Resolved
Prior to operating on the waters of the Great Lakes, provided currently corrected charts and publications, including the applicable Coast Guard Light List and U. S. Coast Pilot.
Condition: Unknown
Due 12 June 1998
Resolved 12 June 1998
Documentation
Issued 12 June 1998
Resolved
Prior to operating on the waters of the Great Lakes, provide satisfactory evidence of compliance with applicable provisions of the Great Lakes Radiotelephone Agreement.
Condition: Unknown
Due 12 June 1998
Resolved 12 June 1998
Navigation
Issued 23 June 1997
Resolved
Compass deviation table is missing. Providecurrent compass deviation tabel.
Condition: Unknown
Due 10 July 1997
Resolved 29 August 1997
Electrical
Issued 23 June 1997
Resolved
Provide proper 110 volt A.C. receptacle on Port Bridge wing overhead._x001C_
Condition: Unknown
Due 10 July 1997
Resolved 29 August 1997
Lifesaving
Issued 23 June 1997
Resolved
Prior to carrying more than 126 passengers, make repairs to 23 adult life preservers. Passenger count is limited to 126 until all repairs are made.
Condition: Unknown
Due 10 July 1997
Resolved 29 August 1997
Construction/Loadline
Issued 23 June 1997
Resolved
Make repairs to two planks on stern where light shows through at approx. 12inches above waterline. Gaps are approx. 1/16"x12"
Condition: Unknown
Due 10 July 1997
Resolved 29 August 1997
Fire Fighting
Issued 23 June 1997
Resolved
Provide straps for all CO2 cylinders in #2 hold.
Condition: Unknown
Due 10 July 1997
Resolved 29 August 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR TIMBER HORM IN STEERING SPACE IAW COAST GUAR NVIC 7-95.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW PORT ENGINE STRINGER LOCATED IN AFT STORAGE SPACE.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW RUDDER SUPPORT BLOCKS IN THE STEERING SPACE AS ORIGINAL.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 11 April 1997
Resolved
REMOVE ALL PETCOCKS FROM FUEL STRAINERS AND PROPERLY PLUG.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW ALL DOUBLER BLOCKS ON THE MAIN ENGINE SEA SUCTION THROUGH HULLS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR OR RENEW FRACTURED PORT FRAME #5 LOCATED IN THE ENGINE ROOM.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REFASTEN TIMBER HORN AND KEEL.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Navigation
Issued 11 April 1997
Resolved
PROVIDE A PROPER SIZE NAVIGATIONAL BELL IAW 72 COLRTEGS (M16672.2) ANNEX III 2 (b).
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 11 April 1997
Resolved
PROPERLY MARK FLARE BOX "DISTRESS SIGNALS" IAW 46 CFR 185.614.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 11 April 1997
Resolved
PROVIDE A COAST GUARD APPROVED FIRST AID KIT IAW 46 CFR 184.710.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROPERLY CAULK AND SEAL TRANSOM PLANKS.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Electrical
Issued 11 April 1997
Resolved
PROVIDE AND PROVE PROPER OPERATION OF A AMPERAGE METER FOR THE SERVICE GENERATOR IAW 46 CFR 183.10-5(g).
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
SEVERAL BUTT BLOCKS WERE RENEWED IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW ALL WASTED FASTENERS ON ALL CLAMPS AND DECK BEAMS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR OR RENEW ALL FRACTURED OR WASTED DECK BEAMS IAW COAST GUARD NVIC 7- 95.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW OR REPAIR ALL BROKEN OR INADEQUATE PIPE HANGERS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROPERLY REPAIR STBD FRAMES #2,#4,#8 AND #12 IN THE FORWARD STORAGE SPACE.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR PORT FRAMES #2,#4,#5 AND #8 IN FORWARD STORAGE SPACE.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REMOVE AND TREAT ANGLE HAIR FUNGUS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 11 April 1997
Resolved
RENEW IMPROPER FUEL HOSE WITH FLEX FUEL HOSE THAT MEETS THE REQUIREMENTS OFSAE J1942 AND J1475 FOR FITTINGS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR AND RECAULK CENTER SHAFT LOG.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 11 April 1997
Resolved
REPAIR OR RENEW THE PORT RUDDER STUFFING BOX.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Electrical
Issued 11 April 1997
Resolved
PROPERLY INSTALL A BELT GUARD ON THE SERVICE GENERATOR PULLEY SYSTEM.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REFASTEN STBD SHAFT LOG IAW NVIC 7-95.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Engineering
Issued 11 April 1997
Resolved
RENEW STBD STRUT CUTLASS BEARING.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Accommodation/Occupational Safety
Issued 11 April 1997
Resolved
ALL MAIN DECK FRACTURED WINDOWS WERE RENEWED.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Fire Fighting
Issued 11 April 1997
Resolved
PROVIDE AND INSTALL APPROVED BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Fire Fighting
Issued 11 April 1997
Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROPERLY ATTACH A LANYARD OR CAPTIVE CHAIN ON THE FORWARD WATERTIGHT HATCH IAW 46 CFR 171.124(b)(2).
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Electrical
Issued 11 April 1997
Resolved
PROVIDE DOCUMENTATION THAT GENERATOR IS RATED AT 50 DEGREES C OR 40 DEGREESC DERATED TO 80% OF THE FULL LOAD RATING IAW 46 CFR 183.10-5(f)(2). AN ADDITIONAL NAMEPLATE SPECIFYING DERATED CAPACITY SHALL BE PROVIDED AND POSTED.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Electrical
Issued 11 April 1997
Resolved
PROVIDE A GENERATOR NAME PLATE IAW 46 CFR 183.10-5.
Condition: Unknown
Due 11 May 1997
Resolved 22 April 1997
Engineering
Issued 11 April 1997
Resolved
PROPERLY MARK ALL EMERGENCY FUEL VALVES IAW 46 CFR 185.608.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
MAKE BOTH THE PORT AND STBDS AFT DECK CLEAT ACCESS PANELS WATERTIGHT WHEN CLOSED AT LEAST 6" ABOVE THE MAINDECK IAW 46 CFR 171.124 OR INSTALL 6" COAMING IAW TABLE 171.124.
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Lifesaving
Issued 11 April 1997
Resolved
PROVIDE AND PROPERLY INSTALL A 60' LIFELINE ON THE LIFE RING BUOY IAW 46_x001C_ CFR 180.070. _x001C_
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR OR RENEW FRACTURED PORT SIDE FRAMES #2,#3,#4,#5 AND #6 IN THE STEERING SPACE.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
ALL PVC PIPING PENETRATING REQUIRED SUBDIVISION WT BULKHEADS AND DECKS MUSTMEET THE REQUIREMENTS OF 46 CFR 182.40-1.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REMOVE FLEX FUEL HOSE TO FUEL FIRED HEATER. FLEX HOSE MUST NOT PENETRATE AWATERTIGHT BULKHEAD IAW 46 CFR 182.720(3)(iii).
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REMOVE AND PROPERLY DISPOSE OF ALL OIL IN THE BILGES.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROPERLY RECAULK BOTH THE PORT AND STBD BOW PLANKS PRIOR TO NEXT SEA TRIAL.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 11 April 1997
Resolved
PROVIDE A MACHINERY GUARD ON THE STBD MAIN ENGINE PULLEY SYSTEM.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Engineering
Issued 11 April 1997
Resolved
RENEW STBD PROPELLER SHAFT PACKING AND PROVE PROPER OPERATION.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Navigation
Issued 11 April 1997
Resolved
RENEW BOTH THE PORT AND STBD RUDDER PACKING AND PROVE PROPER OPERATION.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR OR RENEW FRACTURED FRAMES #1 AND #5 STBD SIDE IN STEERING SPACE IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROPERLY REPAIR OR RENEW WASTED FRACTURED TRANSOM FRAMES IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REPAIR OR RENEW PORT BILGE CLAMP IN STEERING SPACE.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW GASKETS TO THE -2- FORWARD WEATHERTIGHT DOORS AND PROVE THAT DOORS ARE WEATHERTIGHT IN ACCORDANCE WITH 46 CFR 171.124(a)(1).
Condition: Unknown
Due 11 April 1997
Resolved 11 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROVIDE AND INSTALL A GASKET ON THE FORWARD WATERTIGHT HATCH.
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROPERLY REPAIR OR RENEW ROTTED DECK BEAM IN THE SECOND COMPARTMENT BETWEENTHE SECOND AND THIRD FRAMES. RENEW WASTED MAIN DECK IWO DECK BEAM.
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
MAKE ALL WATERTIGHT SUBDIVISION BULKHEADS WATERTIGHT.
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PLUG ALL UNUSED THROUGH HULL VALVES IN THE ENGINE ROOM AND STEERING SPACE.
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROPERLY BOND ALL THROUGH HULL FITTINGS, FUEL TANKS AND ENGINES IAW COAST GUARD NVIC 7-95.
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Engineering
Issued 11 April 1997
Resolved
PROVIDE AND PRIOPERLY INSTALL FUEL SHUTOFF VALVES AT THE ENGINE END OF THE FUEL LINE ON BOTH MAIN ENGINES, OIL FIRED FURNACE AND THE SERVCICE GENERATOR IAW 46 CFR 182.20-40(b)(3).
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Accommodation/Occupational Safety
Issued 11 April 1997
Resolved
PROVIDE AND INSTALL A PROPER THROUGH HULL FITTING FOR THE MSD TANK VENT IAWNVIC 7-95.
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Accommodation/Occupational Safety
Issued 11 April 1997
Resolved
PROVIDE A MEANS TO LOCK THE MSD OVERBOARD VALVE WHEN WITHIN 3 MILE OF LAND IAW MSM2 18.7.C.2 (g).
Condition: Unknown
Due 11 April 1997
Resolved 22 April 1997
Accommodation/Occupational Safety
Issued 11 April 1997
Resolved
PROVIDE AND INSTALL A 30X30 MESH FLAME SCREEN ON THE MSD TANK VENT IAW 33 CFR 159,95(a)(2).
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Electrical
Issued 11 April 1997
Resolved
REMOVE ALL WIRE NUTS FROM VESSEL'S ELECTRICAL SYSTEM IAW 46 CFR 183.340(i).
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
PROVIDE AND INSTALL SIX INCH COAMING FOR THE TWO WX TIGHT DOORS LOCATEDON THE MAIN DECK FORWARD.
Condition: Unknown
Due 24 April 1997
Resolved 24 April 1997
Lifesaving
Issued 11 April 1997
Resolved
PROVIDE AND INSTALL A CORROSION RESISTANT CLIP ON THE LIFE RING BUOY WATERLIGHT LANYARD.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW ALL ROTTED HULL PLANKING ON BOTH THE PORT AND STBD SIDES APPROX 25 FTAFT OF THE STEM.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW ALL ROTTED RUBRAILING ON THE PORT AND STBD SIDES.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW WORM SHOE AT THE FORWARD AND AFT ENDS OF THE KEEL.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW PORT SHAFT LOG.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW PLANK ADJACENT TO THE PORT SHAFT LOG.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW PLANKING WERE SEAMS ARE TO LARGE TO ALLOW CAULKING WIHOUT INSTALLING DAMS ON THE INTERIOR. REMOVE ALL EXISTING CAULKING DAMS.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Navigation
Issued 11 April 1997
Resolved
REMOVE AND REPAIR THE WORN PORT AND STBD RUDDER TUBES.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
REMOVE ALL SHORT PLANKS ON THE PORT AFT QUARTER AND RENEW PLANKS IAW NVIC 7-95.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 11 April 1997
Resolved
RENEW THE TOP TRANSOM PLANK IAW NVIC 7-95.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Engineering
Issued 11 April 1997
Resolved
PROPERLY REPAIR BOTH PROPELLERS.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Construction/Loadline
Issued 15 November 1996
Resolved
Make vessel available for complete hull examination, prior to carrying passengers, but no later than 15 Mar 97. Vessel's Certificate of Inspection will be retained at MSO Chicago pending satisfactory completion of this requirement.
Condition: Unknown
Due 15 November 1996
Resolved 15 November 1996
Documentation
Issued 28 October 1996
Resolved
PROVE COMPLIANCE WITH PRE-EMPLOYMENT CHEMICAL TESTING REQUIREMENTS LISTED IN 46 CFR 16.210 BY 27 NOV 96. FAILURE TO PROVE COMPLIANCE BY THIS DATE WILL RESULT IN SUSPENSION OF YOUR VESSEL'S CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 28 October 1996
Resolved 28 October 1996
Engineering
Issued 21 June 1996
Resolved
MOUNT OIL PUMP & TANK IN ENGINE ROOM. PROPERLY CONNECT WIRING TO PUMP.
Condition: Unknown
Due 21 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 21 June 1996
Resolved
EXTERMINATE TERNIMITES FOUND IN AFT STEERING COMPARTMENT.
Condition: Unknown
Due 21 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 21 June 1996
Resolved
MAKE REPAIRS TO DAMAGED FRAMES 05 & 06 AFT OF COLLISION BULKHEAD WHERE DECKSTRINGERS MEET SIDE FRAMES.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Construction/Loadline
Issued 21 June 1996
Resolved
drydock and make vessel available for hull inspection by marine inspector prior to 15JAN97
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Accommodation/Occupational Safety
Issued 21 June 1996
Resolved
MOUNT POTABLE WATER PRESSURE STORAGE TANK.
Condition: Unknown
Due 21 July 1996
Resolved 26 July 1996
Lifesaving
Issued 21 June 1996
Resolved
MAKE THE FOLLOWING REPAIRS TO VESSEL BUOYANT APPARATUS OR REMOVE THEM FROM THE VESSEL: PORT/AFT: REPAIR WATERLIGHT, RENEW INNER AND OUTER HANDLINES, RENEW PAINTER, MAKE REPAIRS TO HOLES AND GASHES IN BODY. PORT/FWD: REPAIR WATERLIGHT, RENEW PAINTER. STBD/AFT: RENEW PAINTER.
Condition: Unknown
Due 21 July 1996
Resolved 26 July 1996
Lifesaving
Issued 21 June 1996
Resolved
MARK [name withheld] ON BOTH SIDES (OPPOSITE EACH OTHER) WITH VESSEL NAME AND APPRATUS CAPACITY.
Condition: Unknown
Due 21 July 1996
Resolved 26 July 1996
Construction/Loadline
Issued 21 June 1996
Resolved
INVESTIGATE CAUSE AND MAKE REPAIRS TO LEAK AFT OF ENGINE ROOM THROUGH SHELLPLATING.
Condition: Unknown
Due 21 July 1996
Resolved 26 July 1996
Electrical
Issued 21 June 1996
Resolved
RENEW LIGHT FIXTURES IN 2ND HOLD WITH MARINE APPROVED LIGHT FIXTURES.
Condition: Unknown
Due 21 July 1996
Resolved 26 July 1996
Accommodation/Occupational Safety
Issued 21 June 1996
Resolved
RENEW ALL BROKEN GLASS IN MAIN DECK AREA WINDOWS.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Construction/Loadline
Issued 12 June 1995
Resolved
Provide watertight seal on collision bulkhead on one inch hole centerline approximately 4 inches above keel.
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Electrical
Issued 12 June 1995
Resolved
Renew wiring on generator as indicated by inspector and wirenuts on stairwell lighting in accordance with 46 CFR 183.
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Documentation
Issued 12 June 1995
Resolved
Provide current copy of 46 CFR 166-199 (Subchapter 'T').
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Electrical
Issued 12 June 1995
Resolved
Replace existing light fixtures in engine room with U.L. approved marine type light fixtures.
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Lifesaving
Issued 12 June 1995
Resolved
Prior to carriage of passengers at night, demonstrate proper operation of ringbuoy waterlight.
Condition: Unknown
Due 13 June 1995
Resolved 8 September 1995
Engineering
Issued 12 June 1995
Resolved
Renew flame screen on STBD fuel tank vent which is painted over.
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Electrical
Issued 12 June 1995
Resolved
Provide battery boxes in accordance with 46 CFR 183.05-20.
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Electrical
Issued 12 June 1995
Resolved
Provide proper cover for fuse terminals in storage space.
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Lifesaving
Issued 12 June 1995
Resolved
Renew lines on 7-man buoyant apparatus.
Condition: Unknown
Due 10 July 1995
Resolved 8 September 1995
Fire Fighting
Issued 28 July 1994
Resolved
PROVE CURRENT INSPECTION ON ALL PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Navigation
Issued 28 July 1994
Resolved
PROVIDE CURRENT COPIES OF NAVRUL'S AND 46 CFR PART 166-199.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Lifesaving
Issued 28 July 1994
Resolved
PROVIDE ONE CURRENT RED FLARE.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Lifesaving
Issued 28 July 1994
Resolved
STENCIL VESSELS NAME ON ALL BUOYANT APPRATUS.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Lifesaving
Issued 28 July 1994
Resolved
PROVIDE PROPER FLOAT FREE LINKS WITH CORRECT TAGS.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Lifesaving
Issued 28 July 1994
Resolved
PROPERLY REPAIR MINOR RIPS AND TEARS IN ALL BUOYANT APPRATUS.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Lifesaving
Issued 28 July 1994
Resolved
PROVIDE DATED BATTERIES FOR EPIRB.
Condition: Unknown
Due 28 July 1994
Resolved 28 July 1994
Fire Fighting
Issued 14 July 1993
Resolved
Renew firemain suction piping where PVC piping was used.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Engineering
Issued 14 July 1993
Resolved
Renew fuel oil tank vent lines metallic pipe or tubing.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Lifesaving
Issued 14 July 1993
Resolved
Provide two additional adult PFD's. Vessel is limited to carrying 147 total persons until provided.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Construction/Loadline
Issued 14 July 1993
Resolved
Repair hole at bottom of collision bulkhead.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Lifesaving
Issued 15 December 1989
Resolved
MOUNT 1 RING BUOY.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 15 December 1989
Resolved
REMARK STBD EMERG. FUEL SHUT OFF OK REMOVE CARPET.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
PROVIDE 18' LINES FOR 5 LIFEFLOAT LIGHTS.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 15 December 1989
Resolved
PROVIDE AN AMMETER ON THE AC GENERATOR.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
PROVIDE 1 ADULT PFD PRIOR TO CARRYING 132 PASSENGERS.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
REPAIR AND PAINT 7 MAN LIFEFLOAT.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Deck/Cargo
Issued 15 December 1989
Resolved
PROVIDE SUITABLE PORTABLE BILGE PUMP HOSE.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Navigation
Issued 15 December 1989
Resolved
INSTALL LOCKNUT, SELFLOCK NUT OR DRILL AND PIN STBD RUDDER LINKAGE.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Navigation
Issued 15 December 1989
Resolved
INSTALL PINS TOP AND BOTTOM OF STEERING RAM MOUNTING PIN.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 15 December 1989
Resolved
REPAIR FUEL LEAK GEN. ENGINE.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 15 December 1989
Resolved
DOUBLE CLAMP FUEL FILL LINE HOSES.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Navigation
Issued 12 September 1989
Resolved
RENEW THE TIE BOLTS AND ANGLE IRON WHICH HOLD THE SHAFT LOGS TOGETHER.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Deck/Cargo
Issued 12 September 1989
Resolved
PERMANENTLY AFFIX THE BILGE SUCTION PIPE IN THE COMPARTMENT JUST AFT OF THEENGINE ROOM.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Documentation
Issued 12 September 1989
Resolved
CREDIT DRYDOCK DUE 12MAR91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Navigation
Issued 31 January 1989
Resolved
SECURE LEAK IN PORT RUDDER POST PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Fire Fighting
Issued 31 January 1989
Resolved
PROVIDE A DISCHARGE HOSE FOR HAND HELD BILGE/FIRE PUMP.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Engineering
Issued 31 January 1989
Resolved
REPLACE SPRING TYPE HOSE CLAMPS ON FUEL RETURNS WITH SCREW/THREADED CLAMPS.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Fire Fighting
Issued 31 January 1989
Resolved
PROVIDE COPY OF FIRE EXTINGUISHER SERVICING.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Fire Fighting
Issued 31 January 1989
Resolved
REPLACE HOSE IN FIRE MAIN PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Lifesaving
Issued 31 January 1989
Resolved
INSTALL PENDENTSON INSIDE AND OUTSIDE OF BUOYANT APPARATUS OF 12' LENGTH OFMINIMUM 1/4" LINE THAT IS UV RESISTANT OR DARK AND REPLACE WASTED BANDS ANDGRAB LINES WHERE NOT ATTACHED TO FLOAT PRIOR TO OPERATING COASTWISE.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Lifesaving
Issued 31 January 1989
Resolved
PROVIDE 2 ADDITIONAL RING BOUYS PRIOR TO CARRYING MORE THAN 134 PERSONS COASTWISE.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Fire Fighting
Issued 31 January 1989
Resolved
MOUNT SPARE FIRE EXTINGUISHER.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Fire Fighting
Issued 31 January 1989
Resolved
PROVIDE A BII FIRE EXTINGUISHER BY ENGINE ROOM.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Lifesaving
Issued 31 January 1989
Resolved
RE-STENCIL PFD STOWAGE TO REFLECT ACTUAL STOWAGE.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Deck/Cargo
Issued 31 January 1989
Resolved
INSTALL FLAME SCREENS ON FUEL OIL VENTS OF 30X30 MESH OF CORROSION RESISTANT MATERIAL.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Electrical
Issued 31 January 1989
Resolved
ENSURE ALL WIRE SPLICES ARE EITHER SOLDERED AND SHRINK TUBING OR MECHANICALCRIMP CONNECTORS.
Condition: Unknown
Due 31 January 1989
Resolved 31 January 1989
Construction/Loadline
Issued 6 January 1988
Resolved
INSTALL CAPTURE CHAIN ON FWD. MANHOLE COVER.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988
Accommodation/Occupational Safety
Issued 6 January 1988
Resolved
REPLACE VALVE HANDLE ON S.W. SUCTION VALVE TO TOILETS.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988
Construction/Loadline
Issued 6 January 1988
Resolved
RENEW PLANKS TO GOOD WOOD, PORT SIDE APPROX 40'AFT 5TH PLANK UP FROM CHIME.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988
Construction/Loadline
Issued 6 January 1988
Resolved
REFASTEN BOTTOM PLANK IN WAY OF TRANSOM STBD SIDE.
Condition: Unknown
Due 6 January 1988
Resolved 6 January 1988