Behind this panel: 18 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 18
31 July 2026
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8451231
26 June 2026
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8418656
17 June 2025
Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8160647
7 January 2025
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8059969
17 June 2024
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7979844
29 June 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7726542
19 December 2022
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7609061
28 July 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7517067
18 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7219239
15 December 2020
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7112294
16 July 2020
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7006334
16 July 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6752317
6 December 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6593142
10 July 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6474545
12 September 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6265145
23 May 2017
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6154451
19 July 2016
Spot Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5947324
9 June 2016
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5902459
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 June 2025
Resolved
Stability letter must be available to passengers for inspection, either by posting on board or kept on board and readily available in a weathertight container. IAW MIP 01-13 original COI and stability letter may be kept on shore in a binder and available to crew and passengers upon request.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: New stability letter signed, using existing test from 08DEC2008. New letter reconciles administrative issues with previous letter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 June 2025
Resolved
Install positive action valve in discharge hose of electric bilge pump at hull penetration. Work can be completed when vessel is hauled at conclusion of season.
Action required: 705 - Other - as specified
Resolved 31 July 2026
Resolution: Received photographic evidence of deficiency correction - valve installed as directed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2025
Resolved
Provide one additonal Adult Type I PFD, with required markings, to match COI. Stowage markings not less than 2" in height.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: Confirmed addition of one additional Type I PFD and stowage markings with vessel rep.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2022
Resolved
Each ring life buoy must be marked with Type II retro-reflective material. The arrangement of the retro-reflective material must be specified by IMO Resolution A.658(16). The life buoy was missing retro-reflective tape.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 8 August 2022
Resolution: Operator submitted photo of retro-reflective tape on the life buoy.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2021
Resolved
Engine shutdown not working. Engine shutdown must kill engine and override must be operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2021
Resolution: Engine shutdown and override work as designed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 June 2021
Resolved
Missing correct amount of life jackets on board. The required amount of life jackets should be stored with the amount listed in each compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2021
Resolution: Required amount and stowage is accurate onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 June 2021
Resolved
Fuel shut off missing on tank. Install a valve so the fuel can be secured in an emergency.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2021
Resolved 1 July 2021
Resolution: Installed fuel shutoff valve.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 June 2021
Resolved
Fuel strainer missing flame screen. Installed flame screen must be installed on the fuel strainer.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2021
Resolved 1 July 2021
Resolution: Flame screen is installed properly.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 June 2021
Resolved
Bilge alarm installed properly at the operating station and missing visual. Install the bilge alarm properly for the operate to be able to hear and see alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 2 July 2021
Resolved 1 July 2021
Resolution: Alarm works as designed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 July 2020
Resolved
Conduct and log man overboard / fire drills at least once every three months for all operators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 23 July 2020
Resolution: Drills logged; logbook picture provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 July 2020
Resolved
Provide CG-approved first aid kit (or equivalent contents).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 23 July 2020
Resolution: Equivalent contents provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2020
Resolved
Provide 03 fire buckets of 2.5 gal capacity and mark appropriately in accordance with cite. Vessel had one 2.5 gal bucket and one 5 gal bucket.
Action required: 10 - Deficiency Rectified
Resolved 16 July 2020
Resolution: Proper buckets provided and labeled.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 June 2016
Resolved
Replace connectors on fixed fire fighting controls.
Condition: Improper/Lack of Maintenance
Due 8 July 2016
Resolved 7 July 2016
Resolution: Connectors replaced.
Engineering › Steering Gear System › Bracket/Clamp
Issued 9 June 2016
Resolved
Tighten steering bolts for shaft on hull.
Condition: Improper/Lack of Maintenance
Due 8 July 2016
Resolved 7 July 2016
Resolution: Steering bolts tightened.