POTTER is a 1932 industrial vessel. The Coast Guard has recorded 60 inspections since 1985, most recently in October 2002, along with 134 deficiencies.

Records from 1985 to 2002. Most recent: inspection, 3 October 2002.

Built
1932
Last inspected
3 October 2002
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-55087

Inspections, by type

…with no type recorded15
Years with a record 16 calendar years (1985–2002)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)234.4 ft
Registered tonnagegross 1,500 / net 769
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · PITTSBURGH, PA, UNITED STATES · built 1932
Hull materialSteel
PropulsionSteam Reciprocating
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsNot recorded
DocumentationInvalid
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1500 - Regulatory (Subpart C or D), Gross Ton
769 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 60

3 October 2002 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1683789
29 May 2001 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1066757
6 October 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1416975
8 September 1999 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 783854
5 August 1999 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 775547
9 October 1998 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 803310
9 October 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1436139
20 August 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 795794
9 June 1998 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473331
5 November 1997 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 782319
9 October 1997 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1430468
24 July 1997 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 781366
25 June 1997 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1111702
8 January 1997 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1096570
8 October 1996 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1460925
12 September 1996 Examination of Repairs
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1270226
7 August 1996 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1086563
10 July 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1088821
17 May 1996 Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1442426
16 March 1996 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 75508
27 December 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1385606
12 October 1995 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 882617
3 August 1995 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1188795
15 March 1995 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1174636
11 January 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1171191
27 October 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 832085
12 October 1993 Deficiency Check · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 835081
4 October 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1158934
27 May 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 845272
30 April 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 836457
29 January 1993 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1140576
8 July 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 948533
21 May 1992 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 948224
5 March 1992 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1267722
29 July 1991 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 933038
15 November 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1241204
7 November 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1224717
15 August 1990 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 919880
31 March 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1241766
6 February 1990 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 901274
19 January 1990 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1237908
16 January 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 916240
20 November 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1223578
20 October 1989 Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1201101
5 July 1989 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1035000
29 June 1989 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 974046
17 October 1988 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 886912
13 October 1988 Deficiency Check · Examination of Repairs
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 886883
21 June 1988 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 894174
26 May 1988 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1194183
25 April 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1035159
14 December 1987 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1309896
14 October 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1014884
9 July 1987 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1326636
19 March 1987 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1018594
11 July 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1310849
12 February 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1292993
6 December 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 986606
10 July 1985 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1290817
10 June 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1295367

Deficiency record · 134

Engineering
Issued 6 October 1999 Resolved
Clean or replace flame screens on all 03 deck fuel tank goose necks.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Lifesaving
Issued 6 October 1999 Resolved
Ensure proper operation of General Alarm in galley.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Accommodation/Occupational Safety
Issued 6 October 1999 Resolved
Replace electrical cover for air conditioner located in galley pantry.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Construction/Loadline
Issued 6 October 1999 Resolved
Ensure proper operation of light & alarm for galley walk in freezer.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Construction/Loadline
Issued 6 October 1999 Resolved
Ensure holes in BLKHD are made watertight above WTD in lower port side wire room.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Lifesaving
Issued 6 October 1999 Resolved
Ensure proper operation of the P/A system in the general mode. (all speakers should work off of one switch.)
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Fire Fighting
Issued 6 October 1999 Resolved
Prove proper annual servicing of all fixed and portable fire extinguishing equipment.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Navigation
Issued 6 October 1999 Resolved
Ensure proper display of dayshapes.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Lifesaving
Issued 6 October 1999 Resolved
Properly attach waterlight lanyard to lifering.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Lifesaving
Issued 6 October 1999 Resolved
Properly label general alarm and switch located in deck berthing.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Fire Fighting
Issued 6 October 1999 Resolved
Conduct hydrostatic test of paint locker CO2 bottle.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Electrical
Issued 6 October 1999 Resolved
Prove proper operation of reverse power relay.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Lifesaving
Issued 6 October 1999 Resolved
Clean fuel station containment area free of excess fuel.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Engineering
Issued 6 October 1999 Resolved
Prior to using aux boiler provide proof of boiler hydro to 1 1/4 MAWP.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Electrical
Issued 6 October 1999 Resolved
Ensure proper operation of aft deck hand passageway emergency light.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Accommodation/Occupational Safety
Issued 6 October 1999 Resolved
Clean exhaust fan in bunk room head.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Electrical
Issued 6 October 1999 Resolved
Install electrical outlet for fans in laundry room.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Construction/Loadline
Issued 6 October 1999 Resolved
Properly repair fracture in base of bridge main mast & VHF radio mast.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Construction/Loadline
Issued 6 October 1999 Resolved
Repair or replace upper rung on bridge ladder.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Construction/Loadline
Issued 6 October 1999 Resolved
Install handrails on Texas deck & top of bridge.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Fire Fighting
Issued 6 October 1999 Resolved
Hydro all fire station hoses to 125psi.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Lifesaving
Issued 6 October 1999 Resolved
Ensure type 1 PFD's are installed in all berthing rooms, bridge, and enginerooms.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Fire Fighting
Issued 6 October 1999 Resolved
Ensure all fire stations operate and stations have spanner wrenchs.
Condition: Unknown
Due 6 November 1999
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Fire Fighting
Issued 9 October 1998 Resolved
Properly service SCBA located in the engineroom.
Condition: Unknown
Due 2 December 1998
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Engineering
Issued 9 October 1998 Resolved
Repair steam leak at aft piping plange at aft bulkhead in stbd storage locker.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Construction/Loadline
Issued 9 October 1998 Resolved
Repair hole in main deck above spud well hold, port side.
Condition: Unknown
Due 2 December 1998
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Fire Fighting
Issued 9 October 1998 Resolved
HYDRO TWO FIRE HOSES CURRENTLY PART OF ENGINE ROOM FOAM FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 2 December 1998
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Construction/Loadline
Issued 9 October 1998 Resolved
Inspect all below deck bulkheads and ensure all are watertight.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Construction/Loadline
Issued 9 October 1998 Resolved
ENSURE THAT COLLISION BULKHEAD AND BULKHEAD BETWEEN PAINT LOCKER AND HEAD ARE WATERTIGHT.
Condition: Unknown
Due 2 December 1998
Resolved 3 October 2002
Resolution: Cleared for administrative purposes
Engineering
Issued 9 October 1998 Resolved
Properly label diesel fuel tank on stern.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Fire Fighting
Issued 9 October 1998 Resolved
TEST OR REPLACE FOAM FOR FIXED FOAM FIRE FIGHTING SYSTEM; ENSURE SYSTEM IS FULLY OPERATIONAL.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Electrical
Issued 9 October 1998 Resolved
ENSURE PROPER OPERATION OF ALL EMERGENCY LIGHTING ON BOARD.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Fire Fighting
Issued 9 October 1998 Resolved
REPLACE MISSING GLASS COVER FROM CO2 PULL STATION.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Fire Fighting
Issued 9 October 1998 Resolved
RESTOW FIRE AXE CURRENTLY STOWED DIRECTLY ABOVE ENTRYWAY TO MORE SUITABLE LOCATION.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Accommodation/Occupational Safety
Issued 9 October 1998 Resolved
ENSURE THAT LAUNDRY AREA IS FREE OF EXCESS LINT.
Condition: Unknown
Due 9 October 1998
Resolved 9 October 1998
Electrical
Issued 9 October 1997 Resolved
PROVE PROPER OPERATION OF REVERSE POWER RELAYS ON MAIN SHIPS SERVICE GENERATORS. VESSEL IS TO LIMITED TO SINGLE GENERATOR OPERATION UNTIL CORRECTED.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Accommodation/Occupational Safety
Issued 9 October 1997 Resolved
MARK TRIP HAZARD ON DECK OF AFT BOILER DECK PASSAGEWAY.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
PROVE PROPER OPERATION OF GENERAL ALARM BELL IN HAULING ROOM.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Lifesaving
Issued 9 October 1997 Resolved
MARK GENERAL ALARM CONTACTOR AND BELL IN AFT BOILER DECK PASSAGEWAY.
Condition: Unknown
Due 9 October 1997
Resolved 9 October 1997
Construction/Loadline
Issued 8 October 1996 Resolved
REPAIR/REPLACE WATERTIGHT FITTINGS IWO AFT BLKH, STBD SIDE JET PUMP HOLD.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Construction/Loadline
Issued 8 October 1996 Resolved
PROPERLY SECURE BILGE PIPE CLAMP, IWO JET PUMP HOLD, STBD SIDE.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
ENSURE ALL MOTOR CONTROLLERS AND DICONNECTS ARE PROPERLY LABLED.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Lifesaving
Issued 8 October 1996 Resolved
REMOVE ASH TRAYS FROM ALL BERTHING ROOMS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
REPLACE COVER ON 90DEG. CONDUIT CENTER LINE AFT BREESE WAY.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Lifesaving
Issued 8 October 1996 Resolved
REPLACE RETRO TAPE ON LIFERING PORT SIDE AFT BY GENERATOR ROOM.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
INSTALL GLOBE ON OVERHEAD LIGHT IN TURBINE ROOM PORT SIDE.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Lifesaving
Issued 8 October 1996 Resolved
PROPERLY LABEL ALL GENERAL ALARM STATIONS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Fire Fighting
Issued 8 October 1996 Resolved
MARK CO2 OPERATING STATIONS WITH INSTRUCTIONS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
REPAIR MOTOR CONTROLLERS/JUNCTION BOX IN CIRCULATOR HOLD.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Fire Fighting
Issued 8 October 1996 Resolved
MARK STEAM SMOTHERING SYSTEM WITH OPERATING INSTRUCTIONS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
PROPERLY SECURE BATTERIES IN GENERATOR SPACE.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
PROPERLY LABEL WATER PUMP CONTROLLERS AND SWITCHED PORT SIDE TURBIN ROOM.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Engineering
Issued 8 October 1996 Resolved
REPLACE/REPAIR FLAME SCREENS ON DEISEL FUEL TANK AND F/O TANKS ON 3RD DECK.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996 Resolved
CLEAN OVERHEAD VENT IN 2ND DECK LAUNDRY ROOM.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
PROPERLY BOLT BOTH MAIN ELECTRICAL PANEL COVERS (S/S GEN SPACE).
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
INSTALL PROTECTIVE COVERS ON BOTH S/S GENERATOR EXHAUST PIPES.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996 Resolved
GENERAL HOUSE CLEANING IN BERTHING ROOMS, REMOVE FIRE HAZARDS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996 Resolved
PROPERLY STORE GEAR ADRIFT IN STORAGE SPACE UNDER PILOT HOUSE
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
ALL EXTERIOR LIGHTS NEED METAL GUARD OR UNBREAKABLE LENS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Electrical
Issued 8 October 1996 Resolved
PROPERLY SUPPORT AND BUNDLE ELECTRICAL WIRES THREW OUT VESSEL.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Engineering
Issued 17 May 1996 Resolved
GAS FREE FUEL TANKS AND MAKE AVAILABLE FOR INTERNAL EXAMINATION BY AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 August 1996
Resolved 8 August 1996
Engineering
Issued 12 October 1995 Resolved
LAST HYDROSTATIC TEST WAS ON JULY 1991. CONDUCT THE FOLLOWING TESTS AND EXAMINATIONS TO THE SATISFACTION OF THE COGNIZANT O.C.M.I. PRIOR TO PLACINGTHE BOILER IN SERVICE. 1). HYDROSTATIC TEST AT 1.25 MAWP, 2). SET AND SEAL THE SAFETY VALVE. 3). WITNESS OPERATION OF ALL CONTROLS & ALARMS.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Lifesaving
Issued 15 March 1995 Resolved
PRIOR TO DREDGE POTTER GETTING UNDERWAY, CONTACT MSO ST LOUIS, AND PROVE TOMARINE INSPECTOR 1) HAULING MOTOR GENERATOR OVERSPEED AND 2) BOILER SAFETY SERVICING. VESSEL IS RESTRICTED FROM OPERATING UNDER ITS CERTIFICATE OF INSPECTION UNTIL SUCH TIME ABOVE MENTIONED REQUIREMENTS COMPLETED.
Condition: Unknown
Due 15 March 1995
Resolved 15 March 1995
Electrical
Issued 11 January 1995 Resolved
IDENTIFY ALL MOTOR CONTROLLERS WITH NOMENCLATURE OF EQUIPMENT THEY CONTROL.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Electrical
Issued 11 January 1995 Resolved
CONTACT [name withheld] TO CONDUCT REVERSE POWER RELAY TEST ON GENERATORS.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Fire Fighting
Issued 11 January 1995 Resolved
HAVE ALL PORTABLE EXTINGUISHERS THAT HAVE PASSED 5 YR HYDRO DATE SERVICED.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Unknown
Issued 11 January 1995 Resolved
INSTALL CONTAINMENT ON STERN, BELOW OIL "JUG" RACK.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Electrical
Issued 11 January 1995 Resolved
READJUST FLYWEIGHTS ON GOVERNOR TRIP FOR HAULING MOTOR AFT DC GENERATOR. CONTACT CG TO WITNESS OVERSPEED SHUTDOWN TEST._x001C_
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Engineering
Issued 11 January 1995 Resolved
MAKE PERMANENT REPAIRS TO AFT BOILER BLOW DOWN PIPING, IN AREA OF TEMPORARYREPAIR.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Unknown
Issued 11 January 1995 Resolved
PRESENT ALL AIR RECEIVERS FOR COAST GUARD INSPECTION.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Engineering
Issued 11 January 1995 Resolved
HAVE BOTH STEAM DRUM SAFETY RELIEF VALVES ON AFTER BOILER SERVICED, SUBJECTVALVES RESEAT BELOW MANUFACTURES SPECIFICATIONS. SUPERHEATER SAFETY VALVESON BOTH FWD AND AFT BOILERS TO ALSO BE SERVICED, (PER ORIGINAL REQUIREMENT ISSUED 12OCT93 UNDER CASE MI93039542). ALL VALVES TO "POP" OPEN AND SHUT.
Condition: Unknown
Due 11 January 1995
Resolved 11 January 1995
Navigation
Issued 12 October 1993 Resolved
MAKE ADJUSTMENT TO BRIDGE ENGINE ORDER TELEGRAPH, ENGINE ROOM ANSWER.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Fire Fighting
Issued 12 October 1993 Resolved
SHOW PROOF/HAVE GENERATOR ROOM FIXED CO2 SYSTEM SERVICED.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Fire Fighting
Issued 12 October 1993 Resolved
HAVE 15# CO2 LOCATED AT STBD FUELING STATION HYDROED.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Engineering
Issued 12 October 1993 Resolved
HAVE BOTH FWD AND AFTER BOILER SUPERHEATER SAFETY VALVES SERVICED, ALONG WITH AFT BOILER STEAM DRUM STARBOARD SAFETY. SUPERHEATER SAFETY VALVES TO "POP" WHEN LIFTING, AFT BOILER STEAM DRUM SAFETY SET BELOW OTHER BOILER SAFETYS.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Fire Fighting
Issued 12 October 1993 Resolved
LABLE EMERGENCY PULL FOR GENERATOR ROOM CO2 FLOOD SYSTEM, PORT SIDE AFT OUTSIDE SPACE.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Lifesaving
Issued 12 October 1993 Resolved
CONTACT OCMI TO WITNESS VESSEL DRILLS, BOAT, FIRE, ETC.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Accommodation/Occupational Safety
Issued 12 October 1993 Resolved
CLEAN SPACE LOCATED UNDER DIESEL GENERATOR ROOM.
Condition: Unknown
Due 12 October 1993
Resolved 12 October 1993
Engineering
Issued 4 October 1993 Resolved
PRIOR TO PLACING PROPULSION BOILERS IN NORMAL OPERATION, CONTACT OCMI TO HAVE MARINE INSPECTOR WITNESS SET AND SEAL BOILER SAFETYS.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Documentation
Issued 4 October 1993 Resolved
MAKE VESSEL AVAILABLE FOR INSPECTION PRIOR TO VESSEL GETTING UNDERWAY FOR DREDGING OPERATIONS.
Condition: Unknown
Due 4 October 1993
Resolved 4 October 1993
Engineering
Issued 29 January 1993 Resolved
PRESENT A MINIMUM OF 5% OF BOILER STEAM GENERATING, SCREEN AND RECIRC TUBESFOR INSPECTION.
Condition: Unknown
Due 29 July 1993
Resolved 5 February 1993
Engineering
Issued 29 January 1993 Resolved
PRIOR TO PLACING PROPULSION BOILERS IN NORMAL OPERATION, CONTACT OCMI TO HAVE MARINE INSPECTOR WITNESS SET AND SEAL BOILER SAFETYS.
Condition: Unknown
Due 29 January 1993
Resolved 29 January 1993
Lifesaving
Issued 29 January 1993 Resolved
PRESS UP AIR TANKS IN ORDER TO LIFT RELIEFS, OR HAVE RELIEFS TESTED AT PROPER FACILITY.
Condition: Unknown
Due 12 February 1993
Resolved 5 February 1993
Construction/Loadline
Issued 29 July 1991 Resolved
RENEW HATCH GASKET STBD FWD DECK HATCH.
Condition: Unknown
Due 29 August 1991
Resolved 12 December 1991
Unknown
Issued 29 July 1991 Resolved
RENEW MARPOL GARBAGE PLACARD ABOVE ENGINE ROOM SINK.
Condition: Unknown
Due 29 August 1991
Resolved 12 December 1991
Construction/Loadline
Issued 29 July 1991 Resolved
FREE DOGS ON WTD IN FORWARD CAPSTAIN HOLD.
Condition: Unknown
Due 29 August 1991
Resolved 12 December 1991
Engineering
Issued 29 July 1991 Resolved
MAKE BOTH FORWARD AND AFTER BOILER WATERSIDE INTERNALS READY FOR CG INSPECTION.
Condition: Unknown
Due 29 August 1991
Resolved 12 December 1991
Electrical
Issued 29 July 1991 Resolved
INSTALL LIGHT FIXTURE GUARD FOR INCANDESCENT FIXTURE AFT OF AFT BOILER LOWER LEVEL.
Condition: Unknown
Due 29 August 1991
Resolved 12 December 1991
Accommodation/Occupational Safety
Issued 15 August 1990 Resolved
PROVIDE HAND RELIEVING GEAR ON AIR RECEIVER LOCATED IN AFT CAPSTAN VOID SPACE.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Deck/Cargo
Issued 15 August 1990 Resolved
PROVIDE PROPER CAPACITY PORTABLE OR FIXED OIL CONTAINMENT AROUND FUEL TRANSFER STATIONS.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Documentation
Issued 15 August 1990 Resolved
MAKE LEGIBLE ALL EMERGENCY INSTRUCTION PLACARDS; SEVERAL WERE PAINTED OVER THROUGHOUT.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Documentation
Issued 15 August 1990 Resolved
PROVIDE WRITTEN OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Engineering
Issued 15 August 1990 Resolved
PROVIDE SECOND MEANS OF WATER LEVEL INDICATION.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Electrical
Issued 15 August 1990 Resolved
PROVE OPERATION OF STEAM TURBINE DRIVEN GENERATOR SETS SERVING ANCHOR WINDLASSES.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Electrical
Issued 15 August 1990 Resolved
PROVIDE SUITABLE COVER FOR OPEN ELECTRIC BOXES ON STARBOARD WALL OF WHEEL ROOM.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Electrical
Issued 15 August 1990 Resolved
SECURE EXCESS WATERCOM CABLE IN WHEEL ROOM.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Electrical
Issued 15 August 1990 Resolved
PROPERLY WIRE POWER CABLE TO HEATER IN CENTER SPUD HOLD.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Fire Fighting
Issued 15 August 1990 Resolved
PROPERLY MOUNT PORTABLE FIRE EXTINGUISHERS AS NECESSARY.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Engineering
Issued 15 August 1990 Resolved
REPLACE TUBULAR WATER GAGE ON BOTH MAIN BOILERS WITH LEVEL INDICATING DEVICES OF ACCEPTABLE TYPE.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Navigation
Issued 15 August 1990 Resolved
REMOVE DEBRIS IN STEERING PUMP ROOM COMPARTMENT TO PROVIDE ACCESS TO MOTOR CONTROLLERS.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Engineering
Issued 15 August 1990 Resolved
PROVIDE AT LEAST TWO U-CLAMPS OR OTHER ACCEPTABLE DEVICES ON EACH SAFETY VALVE HAND RELIEVING GEAR.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Engineering
Issued 15 August 1990 Resolved
REMOVE STANDING SHAFT SEAL OIL IN STBD SHAFT COMPARTMENT.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Construction/Loadline
Issued 19 January 1990 Resolved
DRYDOCK VESSEL AND CONDUCT PERMANENT REPAIRS TO THE PORT RUDDER.
Condition: Unknown
Due 19 January 1990
Resolved 19 January 1990
Engineering
Issued 20 October 1989 Resolved
TWO GENERATING TUBES IN HEADER #13, GROUP G, WERE PITTED AND LEAKING. THE PITS WERE INTERNAL. BOTH TUBES WERE REPLACED AND HYDROSTATICALLY TESTED TOTHE SATISFACTION OF THE ATTENDING U.S.C.G. MARINE INSPECTOR.
Condition: Unknown
Due 20 October 1989
Resolved 20 October 1989
Navigation
Issued 29 June 1989 Resolved
INSTALL PROPER SOCKETS AND BULBS IN ALL NAVIGATION LIGHTS AS NEEDED.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989 Resolved
RENEW GENERAL ALARM SIGN - BOILER ROOM.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989 Resolved
STENCIL SCBA LOCATIONS AS REQUIRED BY 46 CFR 97.37-20.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Engineering
Issued 29 June 1989 Resolved
REPLACE STBD AFT FUEL TANK VENT SCREEN. CLEAN PORT FORE AND AFT FUEL TANK VENT SCREEN.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Navigation
Issued 29 June 1989 Resolved
REPAIR OR REPLACE STEAM WHISTLE.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Electrical
Issued 29 June 1989 Resolved
RENEW AFT A/C GENERATOR TACHOMETER.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Navigation
Issued 29 June 1989 Resolved
RENEW WIRING SUPPORT STBE CAPSTAN ROOM.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Electrical
Issued 29 June 1989 Resolved
REWIRE MANUAL CONTROLLER FOR AFT ENGINE ROOM CIRCULATOR (CHILL WATER COMPT)
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Fire Fighting
Issued 29 June 1989 Resolved
REPLACE TWO (02) 2 1/2" FIFTY FOOT FIRE HOSE.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Accommodation/Occupational Safety
Issued 29 June 1989 Resolved
PROVIDE APPROVAL LETTER FOR NON-APPROVED SEWAGE SYSTEM.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Electrical
Issued 29 June 1989 Resolved
INSTALL REMOTE SHUT DOWN FOR AFT GENERATOR COMPARTMENT.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Fire Fighting
Issued 29 June 1989 Resolved
REPLACE PORTABLE FIRE EXTINGUISHER BRACKETS WITH APPROVED BRACKETS AS NEEDED.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Electrical
Issued 29 June 1989 Resolved
REPAIR EMERGENCY LIGHT IN GALLEY.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989 Resolved
CONDUCT HYDRO TEST ON THE TOW DESIGNATED SCBA BOTTLES.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Accommodation/Occupational Safety
Issued 29 June 1989 Resolved
CLEAN EXHAUST DUCTS TO FAN JET PUMP AND LOWER A/C COMPARTMENT.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Engineering
Issued 13 October 1988 Resolved
DESUPERHEATER PITTED DUE TO FEED WATER IMPINGEMENT FROM THE FEED PIPE. THE PITTED SECTION WAS CUT OUT AND REPLACED. AFTER BOILER.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Engineering
Issued 13 October 1988 Resolved
1 EA 2.00" SUPERHEATER SCREEN TUBE RENEWED IN THE AFTER BOILER.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Engineering
Issued 13 October 1988 Resolved
2 EA 1.25" GENERATING TUBES PLUGGED IN THE FORWARD BOILER.
Condition: Unknown
Due 13 October 1988
Resolved 13 October 1988
Electrical
Issued 21 June 1988 Resolved
PROVIDE BATTERY BOXES FOR BATTERIES UNDER WHEELHOUSE.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Engineering
Issued 21 June 1988 Resolved
LABEL EMERGENCY FUEL SHUT OFF'S FOR BOILERS.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Construction/Loadline
Issued 21 June 1988 Resolved
PROVIDE GASKETS FOR ALL WATERTIGHT/WEATHER TIGHT HATCHES AND DOORS (DECK AND ENGINEROOM).
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Electrical
Issued 21 June 1988 Resolved
REPAIR "E" LIGHT IN GENERATOR ROOM.
Condition: Unknown
Due 21 June 1988
Resolved 21 June 1988
Unknown
Issued 9 July 1987 Resolved
PROVIDE APPROVED PLANS FOR ELECTRICAL SYSTEM ALTERATION AND GENERATOR SPACEADDITION. IF PLANS HAVE NOT PREVIOUSLY BEEN SUBMITTED FOR APPROVAL, SUBMITPLANS TO THE MARINE SAFETY CENTER, WASHINGTON, D.C.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Electrical
Issued 9 July 1987 Resolved
PROVIDE EMERGENCY LIGHTING FOR PASSAGEWAYS, STAIRWAYS, AND ESCAPE TRUNKS INCREW QUARTERS, PUBLIC SPACES, AND MACHINERY SPACES TO ALLOW CREW TO FIND THEIR WAY TO OPEN DECKS AS PER 46 CFR 112.15-1.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Unknown
Issued 9 July 1987 Resolved
PRIOR TO NEXT OPERATION TEST SAFETY AND PERFORM HYDRO OF AUXILIARY BOILER IN THE PRESENCE OF A C.G. INSPECTOR.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Fire Fighting
Issued 9 July 1987 Resolved
PROVIDE (2) FIREMAN OUTFITS.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Electrical
Issued 9 July 1987 Resolved
PROVIDE GLOBES AND GUARDS FOR LIGHTING FIXTURES WHERE MISSING THROUGHOUT THE MACHINERY SPACES.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Electrical
Issued 9 July 1987 Resolved
PROVE PROPER OPERATION OF #1 S/S GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Electrical
Issued 9 July 1987 Resolved
LABEL DISTRIBUTION PANAL ELECTRICAL CIRCUITS.
Condition: Unknown
Due 9 July 1987
Resolved 9 July 1987
Engineering
Issued 10 July 1985 Resolved
OPEN FOR EXAMINATION OR HYDROSTATICALLY TEST ALL AIR RECEIVERS.
Condition: Unknown
Due 10 July 1985
Resolved 10 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.