10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2025
Resolved
Prove proper operation of stern light and remount to display proper characteristics, current configuration has a recently added fishing rod mount installed and blocking view of stern light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 May 2025
Resolved 15 May 2025
Resolution: Installed new nav light and mounted on the aft of pilot house.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 14 May 2024
Resolved
Prove proper operation of Engine room bilge alarm.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 May 2024
Resolved 14 May 2024
Resolution: All SAT
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 11 May 2023
Resolved
Install an inter-connected smoke alarm system.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2023
Resolved 15 May 2023
Resolution: Inter-connected smoke alarm installed
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 15 February 2022
Resolved
COD was not available.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2022
Resolved 16 February 2022
Resolution: O/O provided copy of COD
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 15 February 2022
Resolved
O/O could not provide proof of enrollment in a drug testing consortium.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2022
Resolved 16 February 2022
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 February 2022
Resolved
The port and masthead light were inop. Repair/replace prior to nighttime operations.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2022
Resolved 17 February 2022
Resolution: Port light bulb replaced, masthead light was completely blown and replaced, vessel O/O replaced stbd light at the same time.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 February 2022
Resolved
EPIRB battery expired June 2021. Replace EPIRB battery. restricted to within 3NM until replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2022
Resolved 2 March 2022
Resolution: EPIRB battery replaced and tested and verified.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 February 2022
Resolved
Items in first aid kit were expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2022
Resolved 28 February 2022
Resolution: Old kits were thrown away, a new kit was bought and items consolidated into one.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 15 February 2022
Resolved
Drills were not conducted due to extreme cold WX and the vessel does not operate with passengers in the winter. Drills were postponed for warmer WX and prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 May 2022
Resolved 23 May 2022
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 5 May 2021
Resolved
Submit repair proposal for hole in forward steering compartment bulkhead IWO starboard stringer.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2021
Resolved 11 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2021
Resolved
Renew first aid kit.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2021
Resolved 11 May 2021
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 5 May 2021
Resolved
Provide appropriate recovery ladder for man overboard and conduct successful MOB drill.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2021
Resolved 11 May 2021
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 May 2021
Resolved
Provide list of enrolled personnel for all crew on DAPI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2021
Resolved 11 May 2021
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 June 2020
Resolved
Restrict operations to 1000 feet from shore. Obtain current FCC station license IAW 47 CFR 80.13
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2020
Resolved 13 June 2020
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2020
Resolved
ALL PFDs were stowed in a bin on the top deck not secured to the deck and could easily float off the vessel in an emergency situation.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2020
Resolved 16 June 2020
Resolution: PFD bin on the top deck was secured using brackets fastened to the deck and the bins secured to the brackets.
//s// [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2020
Resolved
Label PFD stowage with size and quantities of PFDs stowed in locations
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
Resolution: Labeling for all PFD storage locations throughout the vessel were installed.
//s// [name withheld], GS-12
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 4 June 2020
Resolved
Prove proper size "weak links" for life floats installed.
2-22 and 1-25 person life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 4 June 2020
Resolution: Vessel representative sent pictures of weak links sized for 22 or more persons for the vessel's 25 person life floats.
//s// [name withheld]12
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 June 2020
Resolved
2 floating electric water lights were identified as not IAW Q specifications and in a water tight container. for the vessel's life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
Resolution: Floating electric water lights were replaced with new elec. water lights.
//s// [name withheld]12
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 June 2020
Resolved
Floating electric water light for the type IV throwable was identified not in a water tight container and in accordance with Q specs for a floating electric water light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
Resolution: Floating electric water light for the type IV ring bouy was replaced with a new elec. water light.
//s// [name withheld], GS-12
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 4 June 2020
Resolved
Provide FCC Safety radio certificate. Restrict operations to 1000 feet from shore.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2020
Resolved 12 June 2020
Resolution: Vessel's radios were inspected and issued an approved FCC radio safety certificate. Vessel O/O sent documentation of the deficiency corrected.
//s// [name withheld]
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 4 June 2020
Resolved
Stability letter must be posted under transparent material as instructed on the stability letter.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
Resolution: Stability letter posted IAW stability letter verbage.
//s// [name withheld]
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 June 2020
Resolved
Post COI under suitable transparent material under glass where visable to passengers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2020
Resolved
Remove and replace expired contents in the first aid kit
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 18 June 2020
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 4 June 2020
Resolved
Provide current and up to date charts for the vessel's operating area.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2020
Resolved 29 June 2020
Resolution: Provided email picture and picture of chart booklet purchased.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 4 June 2020
Resolved
RESTRICT OPERATION TO NO MORE THAN 20 MILES FROM SHORE untill prove proper operation of the vessel's SSB/ MHF radio.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2020
Resolved 4 June 2020
Resolution: Vessel representative found a breaker that had been secured for the vessel's SSB. Vessel's SSB was operated and tested.
//s// [name withheld], GS-12
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 4 June 2020
Resolved
Stow PFDs on both the top and main deck in accordance with the vessel's posted stowage plan.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
Resolution: PFDs were relocated to both the main and top deck IAW with the vessel's posted emergency instructions.
//s// [name withheld], GS-12
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 June 2020
Resolved
Provide sound signal device IAW 33 CFR
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2020
Resolved 4 June 2020
Resolution: A breaker in the machinery space was secured for the vessel's sound producing device. Vessel's SPD is fully operational IAW 33 CFR
//s// [name withheld], GS-12
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 4 June 2020
Resolved
In the collision bulkhead high and at the center line are two holes where old piping ran. The piping was easily removed and holes remained in the structure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
Resolution: Vessel representative/ O/O installed a plate over the holes where the old piping ran.
//s// [name withheld]12
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 June 2020
Resolved
Hose used for rural bilge pump arrangement was of a low grade plastic material, not intended for use de-watering a vessel in an emergency situation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 16 June 2020
Resolution: the old low grade plastic hose was removed and a new hose was installed of better grade and quality.
//s// [name withheld]12
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 May 2019
Resolved
Replace hydrostatic release prior to operating more than 3 miles from shore.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2019
Resolved 4 June 2019
Resolution: Recieved proof of instalation of and purchase receipt for hydrostatic release
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Remove and reisntall #6 plank stbd. side fwd
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 12 April 2019
Resolution: Opened up
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Make available for inspection #1 plank stbd side
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Addreess wastage iwo fasteners at rub rail stbd. side
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Make available for inspection #1 plamk aft stbd side
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Make available for inspection #12 plank at stbd. aft qtr.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed reapair
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Open up and make available for inspection MDE overboard discharges
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed reapair
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 9 April 2019
Resolved
Conduct permanenet reapirs to hull iwo #1 transverse fwd. of aft port transom post
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 9 April 2019
Resolved
Sister deck frame iwo rudder assembly
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2019
Resolved
Replace hydraulic fittings for rudder assembly
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Repalce ecenterline clamp along transom
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 April 2019
Resolved
make available for inspection port side hull staining
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 12 April 2019
Resolution: made available for inspecion, sat
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 April 2019
Resolved
Arrest water ingress from main deck
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 8 May 2019
Resolution: Completed repair
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 9 April 2019
Resolved
Make Focsle available for inspection
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 12 April 2019
Resolution: O/O made available, see narrative
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2019
Resolved
Repalce mechanical hardware for shafts entering into shaft logs
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 9 April 2019
Resolved 12 April 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Conduct permanet repairs to transom iwo MDE overboards
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2019
Resolved 12 April 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
Conduct permanent repairs to #1 transverse frame fwd. of collision blkhd. stbd. and associated under deck transverse
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 April 2019
Resolved 12 April 2019
Fire Fighting › Fire Pumps › Pressure
Issued 22 February 2017
Resolved
Prove proper operation of Fire Main.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 February 2017
Resolved 15 March 2017
Resolution: MI witnessed a satisfactory test of fire pump
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 22 February 2017
Resolved
Provide proper FCC documents for vessel
Due 15 March 2017
Resolved 15 March 2017
Resolution: MI attended vessel and witnessed the correction of this item.
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 22 February 2017
Resolved
Install flame bowls on strainers
Condition: Improper Installation
Due 15 March 2017
Resolved 15 March 2017
Resolution: MI attended vessel and witnessed the correction of this item.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 22 February 2017
Resolved
Label all breakers in engine room
Condition: Improper Installation
Due 15 March 2017
Resolved 15 March 2017
Resolution: MI attended vessel and witnessed the correction of this item.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 February 2017
Resolved
Install an additional hose clamp on the STBD MDE S/W supply hose.
Due 15 March 2017
Resolved 15 March 2017
Resolution: MI attended vessel and witnessed the correction of this item.
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 20 June 2016
Resolved
Post emergency broadcast placard at operating station 46 CFR 184.506
Action required: 705 - Other - as specified
Due 6 July 2016
Resolved 21 June 2016
Resolution: Posted