Records from 2016 to 2026. Most recent: inspection, 31 July 2026.
Inspection history · 17
31 July 2026
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8451245
26 June 2026
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8418650
17 June 2025
Administrative Inspection · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8160625
7 January 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8059636
17 June 2024
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7979819
29 June 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7726529
19 December 2022
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7609057
28 July 2022
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7517075
18 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7219242
15 December 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7112309
7 October 2020
Administrative Inspection · Plan Review "T" Boat · Construction Oversight
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7073080
16 July 2020
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7006396
16 July 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6752283
6 December 2018
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6593150
12 July 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6482334
28 February 2017
Internal Structural Exam · Drydock Exam · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6092606
9 June 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5905910
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 June 2025
Resolved
Replace shaft packing bellows and all associated seals, flanges and O-rings to new. Bellows is cracked at every ridge and has exceeded service life.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 July 2026
Resolution: Received photographic evidence of compliance. New dripless packing installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 June 2025
Resolved
Stability letter must be available to passengers for inspection, either by posting on board or kept on board and readily available in a weathertight container. IAW MIP 01-13 original COI and stability letter may be kept on shore in a binder and available to crew and passengers upon request.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: New stability letter signed, using existing test from 08DEC2008. New letter reconciles administrative issues with previous letter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 June 2025
Resolved
Install positive action valve in discharge hose of electric bilge pump at hull penetration. Work can be completed when vessel is hauled at conclusion of season.
Action required: 705 - Other - as specified
Resolved 31 July 2026
Resolution: Received photographic evidence of compliance. Valve installed as directed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2025
Resolved
Provide one additional Adult Type I PFD, with required markings to match COI. Stowage markings not less than 2" in height.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 July 2025
Resolution: Confirmed addition of one additional Type I PFD and stowage markings with vessel rep.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 July 2022
Resolved
Each ring life buoy must be marked with Type II retro-reflective material. The arrangement of the retro-reflective material must be specified by IMO Resolution A.658(16). The life buoy was missing retro-reflective tape.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 8 August 2022
Resolution: Operator submitted photo of life buoy with retro-reflective tape.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 July 2022
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The bracket for the fire extinguisher was wasted and not properly securing the fire extinguisher.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 August 2022
Resolved 8 August 2022
Resolution: Operator submitted photo of newly installed portable fire extinguisher bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 18 June 2021
Resolved
Properly label life jacket stowage containers to include the amount of lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2021
Resolved 3 August 2021
Resolution: All life jacket stowage is label correctly.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 June 2021
Resolved
Fixed fire fighting system for the engine room does not shutdown the M/E. Prove proper operation of engine shutdown and alarm.
Action required: 17 - Rectify deficiencies prior to departure
Due 19 June 2021
Resolved 18 June 2021
Resolution: Engine shutdown and override work as designed.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 July 2020
Resolved
Conduct and log man overboard / fire drills at least once every three months for all operators.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 23 July 2020
Resolution: Drills logged; picture of logbook provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 July 2020
Resolved
Provide CG-approved first aid kit (or equivalent contents).
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 23 July 2020
Resolution: Equivalent contents provided.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 16 July 2020
Resolved
Provide fuel tank that complies with-- and conduct pre- and post-installation tests in accordance with-- 46 CFR 182.440 prior to 31 Dec 2020.
Action required: 705 - Other - as specified
Due 31 December 2020
Resolved 16 December 2020
Resolution: Inspected fuel tank and spec plaque on scene
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 July 2020
Resolved
Provide number of lifejackets required by COI. Missing 01 adult lifejacket.
Action required: 10 - Deficiency Rectified
Resolved 17 July 2020
Resolution: Additional lifejacket provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2020
Resolved
Provide 03 fire buckets of 2.5 gal capacity and mark appropriately in accordance with cite. Vessel had one 2.5 gal bucket and one 5 gal bucket.
Action required: 10 - Deficiency Rectified
Resolved 17 July 2020
Resolution: Sufficient buckets provided and marked.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 28 February 2017
Resolved
Install MDE and prove proper installation and operation to attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 18 April 2017
Resolution: Tested MDE sat
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 28 February 2017
Resolved
Renew cutlass bearing.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 18 April 2017
Resolution: Tested saft, sat
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 9 June 2016
Resolved
Repair Stern Light. Vessel is restricted to day time operations only.
Condition: Improper/Lack of Maintenance
Due 8 July 2016
Resolved 5 July 2016
Resolution: Light repaired.
Engineering › Bilge Water Management System › Not Operational
Issued 9 June 2016
Resolved
Repair float switch.
Due 8 July 2016
Resolved 7 July 2016
Resolution: Float switch replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 9 June 2016
Resolved
Repair fire bottle switch wire conector on bottle.
Condition: Damaged By Earlier Event
Due 8 July 2016
Resolved 7 July 2016
Resolution: Connectors replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 9 June 2016
Resolved
Replace battery in float light.
Condition: Improper/Lack of Maintenance
Due 8 July 2016
Resolved 7 July 2016
Resolution: Battery replaced.