MAURY USCG vessel records Sign in
← All vessels

RUBY

RUBY is a 1979 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1984, most recently in July 2023, along with 69 deficiencies, 4 operational controls and 1 casualty investigation in 2009.

Records from 1984 to 2023. Most recent: inspection, 19 July 2023.

Built
1979
Last inspected
19 July 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYR6002
Flag
UNITED STATES
367070550
Maury page id
psix-55113

Inspections, by type

…with no type recorded6
Years with a record 35 calendar years (1984–2023)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)57.0 ft × 13.0 ft × 6.7 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMILLERICK BROS · COTATI CA, UNITED STATES · built 1979
Hull materialSteel
PropulsionAuxiliary Sail
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WYR6002MMSI 367070550 · active · compulsorily equipped · granted 19 September 2025, expires 12 December 2035
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

19 July 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7753174
27 April 2022 Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7435428
4 April 2022 Deficiency Check · COI Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7418594
9 November 2021 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7348078
13 October 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7331102
15 July 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7257513
7 October 2020 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7072639
29 June 2020 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6990096
2 April 2020 Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6935036
3 June 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6701892
30 May 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6428398
6 April 2018 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6391130
5 April 2017 DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6117748
19 May 2016 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5881570
4 April 2016 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5846677
5 June 2014 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4856943
1 May 2009 Examination of Repairs · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3465274
26 April 2009 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3509786
20 May 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3199275
17 March 2008 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3166127
17 April 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2993228
16 May 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639804
1 March 2006 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2591281
24 March 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2318974
17 June 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2101592
13 May 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2066439
27 April 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2053706
6 April 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2038728
5 August 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1867576
22 June 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1970737
12 May 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779788
22 April 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1607521
8 April 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1602526
25 April 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1403368
30 May 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384465
20 March 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1435004
10 March 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 803370
24 April 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1123834
22 April 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1126744
15 April 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 788720
11 March 1998 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1438704
19 March 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1371709
15 April 1996 Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885873
19 March 1996 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787141
21 March 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1152355
12 April 1994 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167728
7 April 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1167704
3 June 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1136641
28 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1143855
26 March 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148779
23 March 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 836065
28 April 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1268521
31 March 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 961314
16 May 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219362
25 March 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 997762
4 June 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 930847
4 June 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1237311
6 April 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 908767
23 March 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1218272
23 March 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1276388
8 July 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 900546
13 April 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 889770
30 March 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1299375
23 March 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018708
23 April 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 999487
16 April 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 998658
12 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 992318
3 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1289541
19 November 1984 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1282365

Deficiency record · 69

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 April 2022 Resolved
An adult life jacket must be provided for each person carried on board. Vessel was found to have damaged Kapok life jackets. Vessel limited to a total of 16 adults (passengers and crew) until life jackets are replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 April 2022
Resolution: Vessel rep sent photos to MI, meet requirments to MI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2022 Resolved
Each ring life buoy on a vessel must be stowed in a way that it can be rapidly cast loose. Vessel had life ring stowed with lifeline taped up and floating light tangled in lanyard. Operator corrected during inspection.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 4 April 2022
Resolution: Corrected on the spot. Vessel Rep cut tape and MI witnesed Operator deploying life-ring rapidly.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2022 Resolved
Cooking and heating equipment must be suitable for marine use. Equipment designed and installed IAW ABYC "Galley Stoves" and "Boat Heating Systems" or with NFPA 302 complies with this requirement. Vessel carries kerosene for a galley stove, but does not meet the requirements. Show that cooking system meets requirements or remove kerosene from vessel when underway with passengers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 18 April 2022
Resolution: Vessel Rep Sent photos of removal of Kerosense and placed off the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2022 Resolved
A lighting fixture may not be used as a connection box for a circuit other than the branch circuit supplying the fixture. Vessel has a USB charger spliced into lighting circuit in forepeak.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 18 April 2022
Resolution: Vessel Rep sent to photo removing electrical plug from light, all sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 4 April 2022 Resolved
Vessels subject to part III of title III of the Communications Act that operate in waters described in 80.901 must be equipped with a VHF-DSC radiotelephone installation. Vessel VHF does not have proper MMSI programmed in.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2022
Resolved 18 April 2022
Resolution: Vessel Rep Sent photo, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 October 2021 Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following tests: For fixed-gas fire extinguishing systems, the inspections and tests required by table 176.810(b) of this section. The pre-engineered fire system is out of date for annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 October 2021
Resolution: Master had system serviced. Uploaded records in documents.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 13 October 2021 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation. VHF at operator station is not connected to GPS and is programmed with the wrong MMSI number. 47 CFR 80.905(a)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 9 November 2021
Resolution: Recieved photos of proper inputs in VHF. Now broadcasts MMSI as well as GPS.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2021 Resolved
All inspected sailing vessel owner/operators should have a written Preventive Maintenance Plan (PMP) that specifically addresses their vessel's sail rigging and components. Owner should submit a PMP that includes daily, monthly, annual inspection regime and life-cycle of standing and running rigging installed. PMP should also include a daily check of the stays'l stay shackle pin. NVIC 02-16 Section II.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 9 November 2021
Resolution: PMP created and sent to Sector SF.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 October 2021 Resolved
A vessel must be operated in accordance with applicable laws and regulations and in such a manner as to afford adequate protection against hazards that might endanger the vessel and the persons being transported. Seizing wire missing on all shackles at deck level. Seize all shackles in rigging system.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2021
Resolved 9 November 2021
Resolution: Received photos of seizing wire in shackles.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 July 2021 Resolved
Inspected vessels must undergo an annual inspection within 3 months before or after each aniversary date. Vessel is overdue for 2021 annual inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2021
Resolution: Completed annual.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 7 October 2020 Resolved
The construction and arrangement of a vessel must allow safe operation of the vessel giving consideration to means of escape in case of a sudden unexpected casualty. Vessels forward cabin area escape hatch does not have dedicated ladder making escape difficult. Vessel shall provide dedicated, well-marked means of escape from below decks. -46CFR177.100
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 October 2020
Resolved 16 October 2020
Resolution: Vessel provided specially constructed ladder to aide in escape from below decks.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 7 October 2020 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit.” A first-aid kit must be easily visible and readily available to the crew. MI found multiple items in first aid kit that were expired. -46CFR184.710 -46CFR160.041
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 16 October 2020
Resolution: All expired items were replaced with new.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 October 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts or large enough scale to make safe navigation possible. Charts were found to be outdated. -46CFR184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 16 October 2020
Resolution: Owner provided new print on demand chart of operating area.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 October 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot or similar publication. Coast Pilot was found to be outdated. -46CFR184.429(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 16 October 2020
Resolution: Operator provided new Coast Pilot Vol. 7
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 October 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Coast Guard Light List. Coast Guard Light List was found to be outdated. -46CFR184.420(a)(3)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 16 October 2020
Resolution: Operator provided 2020 Light List.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2020 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI discovered exposed wire due to improper splice on aft bulkhead of engine room. -46CFR183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2020
Resolved 9 March 2021
Resolution: Operator properly repaired splice.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 30 May 2018 Resolved
05103; Stations in maritime service must be licensed by the FCC. Provide valid FCC Safety Radiotelephony Certificate and FCC Station License. 47CFR80.13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 13 June 2018
Resolution: Received copies fo updated certificate.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 30 May 2018 Resolved
10116; A vessel must carry adequate/up to date US Coast Pilot and Light list appropriate for intended voyage. Obtain up to date versions of above publications. 46CFR184.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 June 2018
Resolved 18 June 2018
Resolution: Received proof of up to date pubs applicable to operating area.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 30 May 2018 Resolved
07124; Fire extinguishers and pre-engineered fire system shall be serviced annually. Proof of last servicing was in 2016. Provide up to date servicing certificates prior to carrying passengers. 46CFR176.180b(1)/NFPA 10 Ch 4
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2018
Resolved 1 June 2018
Resolution: Received verification of servicing.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 May 2016 Resolved
Must ensure all electrical wiring is properly insulated and spliced. 46CFR183.01-15 (old T)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 9 June 2016
Resolution: Wires replaced.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 19 May 2016 Resolved
Provide proof of current annual exam of fixed fire fighting. 46CFR176.810(j)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 June 2016
Resolved 9 June 2016
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 19 May 2016 Resolved
Ensure engine room bilge is free of oil. 46CFR176.830(b)
Due 10 June 2016
Resolved 9 June 2016
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 19 May 2016 Resolved
Must provide verification of drug testing for all crew members with safety duties. 46CFR16
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2016
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 19 May 2016 Resolved
Renew expired battery for the ring buoy waterlight. 46CFR185.726(d)
Due 10 June 2016
Resolved 9 June 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 1 May 2009 Resolved
Vessel main diesel engine seized and is currently being overhauled. Issued no sail 835 until proper operation is proven.
Condition: Unknown
Due 1 June 2009
Resolved 8 May 2009
Fire Fighting › Fire Bucket › Availability
Issued 24 March 2005 Resolved
Provide onboard three, 2 1/2 gallon fire buckets w/lanyard & labelled.
Due 5 May 2005
Resolved 5 May 2005
Engineering › Sea-water System (primary cooling) › Piping
Issued 24 March 2005 Resolved
Reroute raw water cooling hose on MDE to prevent chafing.
Due 5 May 2005
Resolved 5 May 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 March 2005 Resolved
Replace expired ammonia inhalant vials.
Due 5 May 2005
Resolved 5 May 2005
Operations/Management › Drug and Alcohol Testing
Issued 27 April 2004 Resolved
Complete DAPI audit. LEGACY COMPONENT DESC: Recordkeeping
Due 27 May 2004
Resolved 17 June 2004
Resolution: Rcvd fax proof of current enrollment in drug testing program.
Accommodation/Occupational Safety › Medical/First Aid
Issued 27 April 2004 Resolved
Remove expired items in first aid kit an update the same. LEGACY COMPONENT DESC: Medicine Chest
Due 27 May 2004
Resolved 13 May 2004
Lifesaving › Visual Distress Signals (General)
Issued 27 April 2004 Resolved
Renew batteries in way of 3 ea floating water lights. LEGACY COMPONENT DESC: Condition
Due 27 May 2004
Resolved 13 May 2004
Lifesaving › Buoyant Apparatus
Issued 12 May 2003 Resolved
Provide weak link for life floats with 11-20 person capacity per NVIC 7-83. LEGACY COMPONENT DESC: Life float weak link
Action required: 705 - Other - as specified
Due 19 May 2003
Resolved 5 August 2003
Resolution: Recieved faxed purchase reciept.
Navigation › Piloting/Steering
Issued 12 May 2003 Resolved
Update U.S. Coast Pilot and CG Light List per 46 CFR 184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Action required: 705 - Other - as specified
Due 12 June 2003
Resolved 5 August 2003
Resolution: Recieved faxed purchase reciept.
Documentation › Certificates/Documents
Issued 12 May 2003 Resolved
Provide CPR and First Aid Cards for 50% of crew per NVIC 1-91. LEGACY COMPONENT DESC: CPR/First Aid Cards
Action required: 705 - Other - as specified
Due 12 June 2003
Resolved 5 August 2003
Resolution: Recieved faxed copies of cards.
Lifesaving › Buoyant Apparatus
Issued 12 May 2003 Resolved
Label life float paddles with vessel name. LEGACY COMPONENT DESC: Paddles
Action required: 705 - Other - as specified
Due 12 May 2003
Resolved 12 May 2003
Resolution: Labeled paddles.
Lifesaving › Lifebuoys
Issued 22 April 2002 Resolved
Renew pilot house lifebuoy.
Due 22 April 2002
Resolved 22 April 2002
Resolution: Lifebuoy renewed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 April 2002 Resolved
Renew retro on back of one life jacket.
Condition: Improper/Lack of Maintenance
Due 22 April 2002
Resolved 22 April 2002
Resolution: Retro replaced on one life jacket.
Lifesaving › Hand Flares › Storage
Issued 22 April 2002 Resolved
Mark flare box with "Distress Signal" label.
Condition: Placed in Improper Service
Due 22 April 2002
Resolved 22 April 2002
Resolution: Flare box properly labeled.
Lifesaving
Issued 25 April 2001 Resolved
VESSEL IS LIMITED TO TWENTY TOTAL PERSONS UNTIL ADDITIONAL LIFE FLOATS ARE PROVIDED IN ACCORDANCE WITH 46 CFR 180.207; EXCEPT THAT THE VESSEL MAY CARRY 33 TOTAL PERSON ON VOYAGES NOT MORE THAN ONE MILE FROM SHORE.
Condition: Unknown
Due 25 April 2001
Resolved 11 May 2001
Lifesaving
Issued 22 April 1998 Resolved
MOUNT LIFEJACKET DONNING PLACARD
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
STENCIL EMERGENCY ESCAPE - INSIDE AND OUTSIDE
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Engineering
Issued 11 March 1998 Resolved
REPLACE CUTLASS BEARING ON PROPELLER SHAFT.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Deck/Cargo
Issued 11 March 1998 Resolved
PROPERLY REMOUNT MAST AND PROPERLY RECONNECT RIGGING PRIOR TO EMBARKING PASSENGERS.
Condition: Unknown
Due 11 March 1998
Resolved 11 March 1998
Navigation
Issued 7 April 1994 Resolved
RESTORE NAVIGATIONAL SIDELIGHTS TO PROPER OPERATION BY RE-ALIGNING BULB ELEMENTS TO CENTER OF LENS.
Condition: Unknown
Due 21 April 1994
Resolved 13 April 1994
Construction/Loadline
Issued 7 April 1994 Resolved
REMOVE EXCESS OIL FROM BILGES.
Condition: Unknown
Due 21 April 1994
Resolved 13 April 1994
Navigation
Issued 7 April 1994 Resolved
DETERMINE MAGNETIC COMPASS DEVIATION AND POST A RENEWED DEVIATION CARD.
Condition: Unknown
Due 7 April 1994
Resolved 7 April 1994
Construction/Loadline
Issued 7 April 1994 Resolved
CLEAN OIL FROM BILGE PUMPS AND FULLY TEST AFTER BILGES ARE CLEANED.
Condition: Unknown
Due 21 April 1994
Resolved 13 April 1994
Accommodation/Occupational Safety
Issued 7 April 1994 Resolved
REPLACE FASTENING CLIPS ON MIDDLE RAILING GATE CHAIN PORT AND STBD.
Condition: Unknown
Due 21 April 1994
Resolved 13 April 1994
Navigation
Issued 23 March 1993 Resolved
PROVIDE 6 ORANGE FLARES. VSL IS RESTRICTED FROM CARRYING PASSENGERS UNTIL FLARES ARE PROVIDED.
Condition: Unknown
Due 7 April 1993
Resolved 26 March 1993
Lifesaving
Issued 23 March 1993 Resolved
PROVIDE WEAK-LINK FOR 10 PERSON BUOYANT APPARATUS. VSL RESTRICTED FROM CARRYING PASSENGERS UNTIL WEAK-LINK IS PROPERLY INSTALLED.
Condition: Unknown
Due 7 April 1993
Resolved 26 March 1993
Documentation
Issued 23 March 1993 Resolved
PROVIDE OPERATOR'S MARINE RADIO OPERATOR PERMIT.
Condition: Unknown
Due 23 March 1993
Resolved 23 March 1993
Unknown
Issued 31 March 1992 Resolved
PROVIDE DESIGNATION OF SENIOR DECKHAND. SENIOR DECKHAND SHOULD BE AQUAINTED WITH SPECIAL FEATURES AND NOMENCLATURE OF A SAILING VESSEL.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Unknown
Issued 31 March 1992 Resolved
PROVIDE PROPER DRUG TESTING PROGRAM OUTLINING PRE-EMPLOYMENT PAST CASUALTY AND RANDOM DRUG TESTING.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Electrical
Issued 31 March 1992 Resolved
REPAIR AND PROVIDE GLOBES AND CAGES FOR LIGHTS IN ENGINE ROOM.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Documentation
Issued 31 March 1992 Resolved
PROVIDE EMERGENCY CHECK-OFF LIST. IT SHOULD CONTAIN EMERGENCY SAIL DROP AND MAN OVERBOARD UNDER SAIL.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Documentation
Issued 25 March 1991 Resolved
PROVIDE AND POST WASTE MANGMT PLAN.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Documentation
Issued 25 March 1991 Resolved
PROVIDE DRUG FREE TESTING CERTIFICATE.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Documentation
Issued 25 March 1991 Resolved
PROVIDE AND POST MARPOL V PLACARD.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Electrical
Issued 25 March 1991 Resolved
FIT ALL LIGHT FIXTURES WITH APPROPRIATE GLOBES/GUARDS.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Engineering
Issued 23 March 1990 Resolved
PROVIDE A PROPER PRESSURE RELIEVING DEVICE FOR AIR HORN PRESSURE VESSEL
Condition: Unknown
Due 23 March 1990
Resolved 23 March 1990
Deck/Cargo
Issued 30 March 1988 Resolved
REPLACE PORT AND STBD FUEL VENT FLAME ARRESTING SCREENS.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Engineering
Issued 30 March 1988 Resolved
PROVIDE DOCUMENTATION TO PROVE AIR RECEIVER IS EQUIVILENT OR BUILT TO ASME CODE OR REPLACE AIR RECEIVER WITH ASME RECEIVER STAMPED WITH U OR UM.
Condition: Unknown
Due 30 March 1988
Resolved 30 March 1988
Electrical
Issued 16 April 1986 Resolved
REPLACE ONE EMERGENCY FLASHLIGHT.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Documentation
Issued 16 April 1986 Resolved
RENEW FCC OPERATOR'S PERMIT.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Lifesaving
Issued 16 April 1986 Resolved
REPLACE SIX ORANGE SMOKE FLARES.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Lifesaving
Issued 16 April 1986 Resolved
REPLACE THREE ADULT PERSONAL FLOTATION DEVICES.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Lifesaving
Issued 16 April 1986 Resolved
RESTENCIL EMERGENCY EXIT.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Engineering
Issued 16 April 1986 Resolved
CONDUCT OPERATIONAL TESTS OF ENGINEERING, STEERING, AND NAVIGATIONAL SYSTEMS.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Lifesaving
Issued 16 April 1986 Resolved
REPLACE LIFELINE ON RING BUOY.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986

Casualty record · 1

26 April 2009Routine · role: Involved in a Marine Casualty · activity 3509786
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record