HORIZON

HORIZON is a 1980 passenger vessel (inspected). The Coast Guard has recorded 30 inspections since 2016, most recently in March 2026, along with 26 deficiencies and 7 casualty investigations between 2002 and 2026.

Records from 2002 to 2026. Most recent: inspection, 25 March 2026.

Built
1980
Last inspected
25 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 25 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH3298
Flag
UNITED STATES
Maury page id
psix-55121

Documentation record

Registered dimensions (L × B × D)71.0 ft × 25.0 ft × 6.3 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD T CHRISTOPHER · GARDENA, CA, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

30 inspections, each with its date, unit and type; 26 deficiencies with the resolution recorded against each; 7 casualty investigations, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 30

25 March 2026 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8331415
14 February 2026 Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8310748
14 February 2026 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8315046
7 January 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8046256
9 December 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8045052
23 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023701
4 March 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7873966
22 December 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7612192
22 December 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7855806
10 November 2022 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7592645
30 September 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7584503
19 July 2022 Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7512865
10 May 2022 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7453220
19 January 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7382084
25 October 2021 Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7339143
13 August 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7294466
17 June 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7231584
11 May 2021 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7194426
16 April 2021 Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7191011
13 April 2021 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7174669
18 November 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7097732
7 January 2020 DAPI Audit · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6882425
20 September 2019 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6816658
18 March 2019 Examination of Repairs · Hull Examination · Damage Survey · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6644603
19 February 2019 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6611111
20 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6544882
21 February 2018 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6358727
5 January 2018 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6332598
28 February 2017 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6096241
18 February 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5817431

Deficiency record · 26

09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 March 2026 Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2026
Resolved 11 May 2026
Resolution: Received photo. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring was deteriorated and in need of replacement.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2026
Resolved 11 May 2026
Resolution: Received photo. All SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2026 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in wheel house. Remove dead end wiring and update electrical plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2026
Resolved 11 May 2026
Resolution: Received photo. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2026 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel experienced electrical issue's resulting in vessel going full astern without throttle control. Submit tech report to local OCMI once issue is discovered/corrected to set up a sea trial before the vessel can operate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 February 2026
Resolution: Throttle controls were troubleshot and repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2025 Resolved
The proposed vessel modifications and egress drill must be completed by the vessel's next scheduled drydock or January 1, 2026, whichever comes first. Vessel completed drydock on December 09, 2024 and has not completed all approved egress modifications. Vessel is restricted to no overnight passenger or passengers in bunk areas until all egress modifications and drill are completed.
Action required: 705 - Other - as specified
Resolved 18 February 2025
Resolution: Egress completed. All SAT
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 7 January 2025 Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. Vessel doesn't have a intergraded smoke detector in the E/R. Install smoke detector and notify local OCMI for operational test. Vessel is restricted to limited coastwise until intergraded smoke detector is installed in the E/R.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 27 January 2025
Resolution: Received photos of new smoke detector. All SAT.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 January 2025 Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI found two bulkhead penetrations in the laz to the E/R. Fill in holes with fire retardant material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 27 January 2025
Resolution: Received photos of fire stop installed. All SAT.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found 2 groups of dead-end wire in the Laz. Properly secure dead-end wires and notify local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 27 January 2025
Resolution: Received photos of removed dead end wires. All SAT.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 January 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. MI found missing Aspirin and ammonia inhalant. Provide proof of missing items to OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 January 2025
Resolved 27 January 2025
Resolution: Received photos of medication. All SAT.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 March 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 11 March 2024
Resolution: Received photo of new station License certificate from owner.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 March 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI discovered 01 ring buoys line was deteriorating. Remove from service and replace with new life buoy. Submit proof to local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 11 March 2024
Resolution: Received photo of new life bouy from owner.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2024 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] found 02 drainage ports were covered up. Remove and provide proof to local OCMI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 3 April 2024
Resolution: Received photo from owner showing the blocked scuppers were clear.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 4 March 2024 Resolved
An interconnected detection and alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. MI found 01 smoke detector on the bridge that failed to visual and audible alert. Replace and notify local OCMI to re-attend vessel to conduct operational test.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 March 2024
Resolved 11 March 2024
Resolution: MI attended vessel to conduct operational test, ALL SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022 Resolved
Vessel engine space flooded due to a misaligned rigid, plastic pipe going to bait tank at the first threaded connection point adjacent to pump. Must configure pipe to better align system preventing stress on connection point and reconnect to the satisfaction of the Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: Verified by attending MI: [name withheld]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022 Resolved
Must repair/replace in kind all vessel vital systems (generator boxes, fire pumps, bilge pumps, main engine gear boxes, start batteries) that were damaged from engine space flooding. All systems repaired/replaced must be installed and tested to the satisfaction of the Coast Guard Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 August 2022
Resolution: All systems tested sat and witnessed by attending MI: [name withheld]
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2022 Resolved
Wire in engine room labeled "unknown" found to have unprotected dead end. Wire should either be removed or capped. (Corrected on the spot)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 19 January 2022
Resolution: Corrected on the spot
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 January 2022 Resolved
Hose on wet exhaust system found to have only one clamp. Hose clamp should be double clamped. (Corrected on the spot)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 19 January 2022
Resolution: Corrected on the spot
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 January 2022 Resolved
Port side CO2 pull station instruction placard found to be worn. Replace placard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2022
Resolved 4 February 2022
Resolution: POC provided proof of new placard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 20 December 2019
Resolved 26 September 2019
Resolution: Drawing submitted by operator. Minor errors in drawings, vessel operator making changes as discussed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 March 2019 Resolved
Provide a repair plan for USCG approval for 4'x 1' protrusion/damage on portside hull. Crop and renew to original material IAW repair plan.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 April 2019
Resolution: Hull repaired.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018 Resolved
ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 October 2018
Resolution: Verified in VIVS.
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 February 2017 Resolved
Replace non-metallic caps with metallic caps on through-hull fittings.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 1 March 2017
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 28 February 2017 Resolved
Provide waste management plan.
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 1 March 2017
Construction/Loadline › Structures › Superstructure
Issued 18 February 2016 Resolved
Make repairs/replace termite infested rotted wood main mast.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 2 March 2016
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 February 2016 Resolved
Prove proper operation of SSDG fuel oil supply shut off valve.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 2 March 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 18 February 2016 Resolved
Prove proper operation of both MDE/SSDG's.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 2 March 2016

Casualty record · 7

10 October 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1706109
17 May 2003Routine · role: Involved in a Marine Casualty · 1 dead · activity 1815799
13 August 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3027221
12 October 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3079043
2 November 2007Routine · role: Involved in a Marine Casualty · 1 dead · activity 3093308
22 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4822298
14 February 2026Routine · role: Involved in a Marine Casualty · activity 8315046
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.