← All vessels
HORIZON
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named HORIZON
HORIZON is a 1980 passenger vessel (inspected). The Coast Guard has recorded 125 inspections since 1984, most recently in March 2026, along with 104 deficiencies and 7 casualty investigations between 2002 and 2026.
Records from 1984 to 2026. Most recent: inspection, 25 March 2026.
- Built
- 1980
- Last inspected
- 25 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 125
- Deficiencies
- 104 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 7 investigations · 2002–2026
Identity
626408
WDH3298
55121
Flag
UNITED STATES
368356330
Maury page id
psix-55121
Inspections, by type
…with no type recorded28
Years with a record
41 calendar years (1984–2026)
The 125 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)71.0 ft × 25.0 ft × 6.3 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRICHARD T CHRISTOPHER · GARDENA, CA, UNITED STATES · built 1980
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDP4646MMSI 368356330 · active · compulsorily equipped · granted 7 March 2024, expires 7 March 2034
WDH3298MMSI 338776000 · expired · compulsorily equipped · granted 19 February 2014, cancelled 20 April 2024
WAB6355MMSI 366944880 · expired · compulsorily equipped · granted 4 May 2004, cancelled 23 August 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 125
25 March 2026
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8331415
14 February 2026
Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8310748
14 February 2026
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8315046
7 January 2025
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8046256
9 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8045052
23 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8023701
4 March 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7873966
22 December 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7612192
22 December 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7855806
10 November 2022
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7592645
30 September 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7584503
19 July 2022
Damage Survey · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7512865
10 May 2022
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7453220
19 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7382084
25 October 2021
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7339143
13 August 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7294466
17 June 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7231584
11 May 2021
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7194426
16 April 2021
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7191011
13 April 2021
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7174669
18 November 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7097732
7 January 2020
DAPI Audit · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6882425
20 September 2019
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6816658
18 March 2019
Examination of Repairs · Hull Examination · Damage Survey · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6644603
19 February 2019
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6611111
20 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6544882
21 February 2018
DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6358727
5 January 2018
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6332598
28 February 2017
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6096241
18 February 2016
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5817431
29 December 2015
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5788361
22 March 2014
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4822298
11 January 2012
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4221873
16 February 2011
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3935193
11 February 2010
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3673566
8 February 2010
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3677573
13 January 2010
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3663305
12 February 2009
Deficiency Check · DAPI Audit · MTSA/ISPS Verification · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3401764
7 January 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3378469
3 August 2008
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3288647
19 February 2008
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3141813
6 February 2008
Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3135921
2 November 2007
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3093308
12 October 2007
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3079043
17 January 2007
Inclining Experiment · Deficiency Check · Administrative Inspection · COI Inspection · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2853190
14 February 2006
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2574136
13 January 2006
Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2562330
8 March 2005
Deficiency Check · COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2288950
14 January 2005
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2268887
22 June 2004
MTSA/ISPS Verification
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2107269
27 May 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2080126
11 March 2004
Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2014385
4 December 2003
Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1959075
17 May 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1815799
4 February 2003
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1739501
13 January 2003
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1728295
10 October 2002
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1706109
28 March 2002
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1598743
5 March 2002
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1490802
9 January 2002
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1476965
9 November 2001
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1077305
27 October 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 29626
12 July 2001
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1067454
8 March 2001
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1379340
22 February 2001
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1058515
11 January 2001
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376566
19 July 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 82339
14 July 2000
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 820183
12 May 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1049455
17 April 2000
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1461278
28 January 2000
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 159429
22 December 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213018
22 December 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1461277
9 December 1999
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1046726
4 October 1999
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1440245
10 August 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 92849
1 June 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 810981
18 February 1999
Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 795425
28 January 1999
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375637
7 January 1999
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378540
25 June 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 794238
22 January 1998
Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1437342
4 August 1997
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 143331
20 December 1996
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1354068
25 May 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 536
18 January 1996
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 881222
11 December 1995
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1363431
27 October 1995
Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1441005
20 October 1995
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 103878
16 March 1995
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 866647
10 January 1995
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387698
3 January 1995
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1463154
29 April 1994
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1171546
18 April 1994
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 857179
15 December 1993
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1425386
27 April 1993
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 834137
29 December 1992
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1140249
22 December 1992
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 826050
19 September 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2252
2 June 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 64399
1 May 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 960537
1 May 1992
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 960902
12 March 1992
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1260800
15 January 1992
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 958768
11 December 1991
COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 942701
13 December 1990
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 927232
5 December 1990
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1226854
27 April 1990
Excursion Permit
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 919305
4 January 1990
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 926100
15 December 1989
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1214272
28 April 1989
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1043762
31 March 1989
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1204494
8 December 1988
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1352884
1 December 1988
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 894494
8 December 1987
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1002949
24 November 1987
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1333373
19 December 1986
Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1331883
18 November 1986
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1015820
13 February 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 985778
20 December 1985
Deficiency Check · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 995085
12 December 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1298073
18 November 1985
Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 994370
10 January 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 976841
13 December 1984
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284779
15 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1282366
Deficiency record · 104
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 25 March 2026
Resolved
Each entrance to a space storing carbon dioxide cylinders, a space protected by carbon dioxide systems, or any space into which carbon dioxide might migrate must be conspicuously marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2026
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessel's life ring was deteriorated and in need of replacement.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in wheel house. Remove dead end wiring and update electrical plans.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 February 2026
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel experienced electrical issue's resulting in vessel going full astern without throttle control. Submit tech report to local OCMI once issue is discovered/corrected to set up a sea trial before the vessel can operate.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 January 2025
Resolved
The proposed vessel modifications and egress drill must be completed by the vessel's next scheduled
drydock or January 1, 2026, whichever comes first. Vessel completed drydock on December 09, 2024 and has not completed all approved egress modifications. Vessel is restricted to no overnight passenger or passengers in bunk areas until all egress modifications and drill are completed.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 7 January 2025
Resolved
An interconnected detection and alarm system must be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. Vessel doesn't have a intergraded smoke detector in the E/R. Install smoke detector and notify local OCMI for operational test. Vessel is restricted to limited coastwise until intergraded smoke detector is installed in the E/R.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 January 2025
Resolved
The number of penetrations in a watertight bulkhead must be minimized. A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. MI found two bulkhead penetrations in the laz to the E/R. Fill in holes with fire retardant material.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 January 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI found 2 groups of dead-end wire in the Laz. Properly secure dead-end wires and notify local OCMI.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 January 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. MI found missing Aspirin and ammonia inhalant. Provide proof of missing items to OCMI.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 March 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 March 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. MI discovered 01 ring buoys line was deteriorating. Remove from service and replace with new life buoy. Submit proof to local OCMI.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 March 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] found 02 drainage ports were covered up. Remove and provide proof to local OCMI.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 4 March 2024
Resolved
An interconnected detection and alarm system must: Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system. MI found 01 smoke detector on the bridge that failed to visual and audible alert. Replace and notify local OCMI to re-attend vessel to conduct operational test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022
Resolved
Vessel engine space flooded due to a misaligned rigid, plastic pipe going to bait tank at the first threaded connection point adjacent to pump. Must configure pipe to better align system preventing stress on connection point and reconnect to the satisfaction of the Coast Guard Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2022
Resolved
Must repair/replace in kind all vessel vital systems (generator boxes, fire pumps, bilge pumps, main engine gear boxes, start batteries) that were damaged from engine space flooding. All systems repaired/replaced must be installed and tested to the satisfaction of the Coast Guard Marine Inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 January 2022
Resolved
Wire in engine room labeled "unknown" found to have unprotected dead end. Wire should either be removed or capped. (Corrected on the spot)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 January 2022
Resolved
Hose on wet exhaust system found to have only one clamp. Hose clamp should be double clamped. (Corrected on the spot)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 January 2022
Resolved
Port side CO2 pull station instruction placard found to be worn. Replace placard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 March 2019
Resolved
Provide a repair plan for USCG approval for 4'x 1' protrusion/damage on portside hull. Crop and renew to original material IAW repair plan.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 20 September 2018
Resolved
ZERO DRAFT: no static draft information
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 February 2017
Resolved
Replace non-metallic caps with metallic caps on through-hull fittings.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 28 February 2017
Resolved
Provide waste management plan.
Construction/Loadline › Structures › Superstructure
Issued 18 February 2016
Resolved
Make repairs/replace termite infested rotted wood main mast.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 February 2016
Resolved
Prove proper operation of SSDG fuel oil supply shut off valve.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 18 February 2016
Resolved
Prove proper operation of both MDE/SSDG's.
Electrical › Electrical Distribution System (service) › Conductor
Issued 11 February 2010
Resolved
Remove temporary electrical cords that are permanently installed.
Engineering › Pressure Vessel › Marking and Stamping
Issued 11 February 2010
Resolved
Provide hydrostatic testing documentation for dive tanks.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 11 February 2010
Resolved
Demonstrate proper operation of emergency lighting.
Engineering › Lubricating Oil Storage/Transfer System › Tank
Issued 11 February 2010
Resolved
Properly stow excess lube oil.
Construction/Loadline › Penetrations › Valve Flange
Issued 11 February 2010
Resolved
Cap/plug gate valve in engine room port side aft.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 February 2009
Resolved
Conduct drills (MOB, fire, abandon ship) in presence of CG inspector and log drills as required. No passengers until corrected.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 12 February 2009
Resolved
Condemned (9) adult Type-1 PFDs. Provide an additional (9) adult Type-1 PFDs, vessel restricted to not more than 36 total persons until corrected.
Fire Fighting › Fire Hoses › Condition
Issued 12 February 2009
Resolved
Replace fire hose (port side).
Lifesaving › Inflatable Liferafts › Servicing
Issued 12 February 2009
Resolved
Provide servicing report and properly install liferafts upon return from liferaft servicing facility.
Lifesaving › Hand Flares › Expired
Issued 12 February 2009
Resolved
Provide (9) rocket parachute flares as required by CID Policy Letter #10.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 12 February 2009
Resolved
Provide blanks for exposed breakers on breaker panels (2) on bridge (110/220v).
Navigation › Piloting/Steering › Marine Charts
Issued 12 February 2009
Resolved
Provide current chart of SD Bay (18773).
Documentation › Logs/Records › Drug Test Records
Issued 12 February 2009
Resolved
Provide drug testing MIS Report.
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 12 February 2009
Resolved
Conduct radio check and prove familiarity with SSB radio w/DSC.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 February 2008
Resolved
replace 3 adult PFD.
Lifesaving › Lifebuoys › Serviceable
Issued 19 February 2008
Resolved
replace forward ring buoy.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 19 February 2008
Resolved
Caulk around mesh of fuel vents.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 February 2008
Resolved
Provide instruction for PFD
Communications › Audible Communications › Horn/Whistle
Issued 19 February 2008
Resolved
Repair ship horn.
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 19 February 2008
Resolved
Install galley exhaust with fixed fire system.
Stability › Incline Test › General
Issued 2 February 2007
Resolved
Vsl must prove stability
Construction/Loadline › Hull › Sheerstrake
Issued 17 January 2007
Resolved
Replace port sheerstrake
Construction/Loadline › Hull › Side Shell
Issued 17 January 2007
Resolved
Continue repair port and starboard hull repairs.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 January 2007
Resolved
Provide proof of Drug program
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 January 2007
Resolved
Replace expired first aid equipment
Engineering › Fuel Oil Service System › Hose
Issued 17 January 2007
Resolved
Install proper fuel hoses on both generators.
Engineering › Fuel Oil Service System › Filter
Issued 17 January 2007
Resolved
Install flame bowl on both main engines
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 January 2007
Resolved
Replace 17 life jackets, vsl is restricted to 49 persons
Fire Fighting › Grease Extraction Hood › General
Issued 17 January 2007
Resolved
Vsl has six months to comply with Grease extraction policy.
Fire Fighting › Fire Pumps › Pressure
Issued 17 January 2007
Resolved
Install new gauges and prove that pump produces 60 PSI
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 17 January 2007
Resolved
Vsl must provide an additional MF or imarsat phone.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 14 February 2006
Resolved
Fill void in electrical pannel.
Construction/Loadline › Structures › Superstructure
Issued 14 February 2006
Resolved
Replace cracked starboard side bridge window.
Construction/Loadline › Hull › Keel
Issued 13 January 2006
Resolved
Provide written proposal for planned keel replacement project.
Engineering › Freshwater Generation System › Valve, Dump
Issued 13 January 2006
Resolved
Repair/replace worn ball valve for fresh water maker located in engineroom, starboardside aft.
Electrical › Lighting (service) › Lighting Fixture
Issued 8 March 2005
Resolved
Install guards on lighting fixtures in engine room.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 8 March 2005
Resolved
Ensure nonconductive mat is installed in vicinity of switchboard.
Communications › Alarms/Indicators › Bilge Alarm
Issued 8 March 2005
Resolved
Repair engine room bilge alarm.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 8 March 2005
Resolved
Ensure all publications are up to date, to include light list, coast pilot and tidal current tables.
Navigation › Piloting/Steering
Issued 11 March 2004
Resolved
Procure Light list and Coast Pilot IAW 46CFR184.420 LEGACY COMPONENT DESC: Coast Guard Light List
Communications › Alarms/Indicators
Issued 11 March 2004
Resolved
Provide smoke detector in cook's berthing area IAW 46CFR181.400(c) LEGACY COMPONENT DESC: Fire Alarm
Operations/Management › Equipment Service/Testing
Issued 4 February 2003
Resolved
EPIRB is in operable, Master to replace with new EPIRB NLT 07 Feb. 2003. IAW 46 CFR 180.210. Due to this discrepency, this vessels route is restricted to Limited Coastwise. LEGACY COMPONENT DESC: EPIRB
Electrical › Electric Generation Source (service)
Issued 4 February 2003
Resolved
Permanantly marking on all circuit breakers through out vessel. IAW 46 CFR 183.220(d)(e). LEGACY COMPONENT DESC: Circuit Breaker
Lifesaving › Lifebuoys
Issued 4 February 2003
Resolved
Renew retro tape on fwd. life ring. IAW 46 CFR LEGACY COMPONENT DESC: Markings (ship name/port)
Lifesaving › Buoyant Apparatus
Issued 4 February 2003
Resolved
Put fourth (4th) retro tape on fwd. life ring. IAW 46 CFR 180.75 and IMO Resolution A 658 "16" LEGACY COMPONENT DESC: Life Ring
Electrical › Electrical Distribution System (service)
Issued 4 February 2003
Resolved
Install metallic banding every 24 inches on port side of E/R. IAW 46 CFR 183.340 (b)(4) LEGACY COMPONENT DESC: Cable
Lifesaving › Embarkation Appliances/Stations
Issued 4 February 2003
Resolved
Provide a more suitable Jacobs ladder or demonstrate a rapid deployment of rescue boat. IAW 46 CFR 180.210(a)(1)
Electrical › Electrical Distribution System (service)
Issued 7 March 2002
Resolved
make Lazarette vent fan connections in a JCT box LEGACY COMPONENT DESC: Wiring
Electrical › Electrical Distribution System (service)
Issued 7 March 2002
Resolved
Install metal cable supports on fore and aft cable run in Lazarette. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 7 March 2002
Resolved
Reconnect liquidtight conduit to JCT box on fresh water pump. LEGACY COMPONENT DESC: Junction Box
Electrical › Electrical Distribution System (service)
Issued 7 March 2002
Resolved
Replace JCT box and reconnect cable on anchor motor. LEGACY COMPONENT DESC: Junction Box
Electrical › Electrical Distribution System (service)
Issued 7 March 2002
Resolved
Cover blank spaces in PH electrical panels. LEGACY COMPONENT DESC: Panelboard
Stability › Unintentional Flooding
Issued 7 March 2002
Resolved
Seal cable penetration through FWD Lazarette BLKHD.
Accommodation/Occupational Safety › Ventilation
Issued 7 March 2002
Resolved
Install flame screen on MSD vent
Navigation › Collision/Grounding Avoidance
Issued 7 March 2002
Resolved
Relocate stern light so it may be seen by all vessels IAW COLREGS LEGACY COMPONENT DESC: Navigation Lights
Engineering › Bilge Water Management System
Issued 7 March 2002
Resolved
Repair light on bunkroom bilge alarm. LEGACY COMPONENT DESC: Interface Detector
Stability › Unintentional Flooding
Issued 7 March 2002
Resolved
Install valves on bulkhead penetrations in bunkroom accessible from the deck.
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 March 2002
Resolved
Provide seven adult PFDs and restrict to sixty (60) the number of passengers carried. LEGACY COMPONENT DESC: Quantity
Construction/Loadline
Issued 8 March 2001
Resolved
Install bilge pump.
Documentation
Issued 8 March 2001
Resolved
Post stability letter in wheelhouse.
Documentation
Issued 8 March 2001
Resolved
FAX drug program information to MSO
Documentation
Issued 8 March 2001
Resolved
Post COI in in loung in plain view of passengers.
Lifesaving
Issued 11 January 2001
Resolved
Replace four broken weatherdeck windows in the salon.
Construction/Loadline
Issued 11 January 2001
Resolved
Make two cable runs in lazarette fwd bulkhead watertight.
Construction/Loadline
Issued 11 January 2001
Resolved
Seal leaks in main deck IWO starboard boarding gate, aft port cleat, and two scuppers in transom.
Construction/Loadline
Issued 4 October 1999
Resolved
MINOR FIGERGLASS SEPERATION ALONG CHIME, PORT AND STARBOARD, TWO AREAS. WORK LIST ITEM CLEARED IN YARD.
Unknown
Issued 4 October 1999
Resolved
BULKHEAD PENETRATIONS IN FWD AND AFT ENGINE ROOM BULKHEADS NEED SEALING.
Documentation
Issued 4 October 1999
Resolved
AIR SUPPLY TANKS FOR SCUBA SERVICE APPEARED HEAVILY RUSTED. OWNER HAD NO EVIDENCE OF LAST HYDRO/INSPECTION DATES.
Deck/Cargo
Issued 4 October 1999
Resolved
CORRODED AND MISSING NUTS ON 4 DECK CLEATS. REQD OWNER INSP OF ALL CLEAT FASTNERS AND LOG DEFS IN ACCORDANCE WITH ISM REQS.
Documentation
Issued 18 January 1996
Resolved
PROVIDE TWO RADAR TRANSPONDER (SARTS) AS REQUIRERED BY 47 CFR 80.1095(b), PRIOR TO SAILING ON AN INTERNATIONAL ROUTE.
Construction/Loadline
Issued 27 October 1995
Resolved
Make proper repairs to allision damage at starboard bow hull.
Documentation
Issued 11 December 1991
Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47 CFR 80.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC. VESSEL ROUTE LIMITED TO NO MORE THAN 100 NAUTICAL MILES FROM THE NEAREST LAND UNTIL THIS REQUIREMENT IS CLEARED.
Unknown
Issued 15 December 1989
Resolved
PROVIDE FCC CERTIFICATE OF COMPLIANCE WITH THE RADIO PROVISIONS OF THE INTERNATIONAL CONFERENCE OF SAFETY OF LIFE AT SEA.
Construction/Loadline
Issued 15 December 1989
Resolved
PROVIDE CAPTURE CHAIN TO EACH OF THE DECK HATCHES.
Lifesaving
Issued 1 December 1988
Resolved
PROVIDE 2-25MAN INFLATABLE LIFERAFTS. VESSEL IS RESTRICTED FROM OPERATING IN OCEAN, EXTENDED OCEAN AND INTERNATIONAL VOYAGES UNTIL INFLATABLE LIFERAFTS ARE PROVIDED.
Lifesaving
Issued 1 December 1988
Resolved
PROVIDE LIFEFLOATS FOR FIFTY PERCENT OF THE TOTAL PERSONS ON BOARD PRIOR TOOPERATING VESSEL IN SEASONAL LIMITED COASTWISE ROUTE.
Unknown
Issued 24 November 1987
Resolved
REPAIR INOPERABLE BILGE ALARM LOCATED FORWARD OF COLLISION BULKHEAD.
Unknown
Issued 24 November 1987
Resolved
REPAIR DISCONNECTED DISCHARGE LINE ON MARINE SANITATION DEVICE TO SHORE FACILITY.
Casualty record · 7
10 October 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1706109
17 May 2003Routine · role: Involved in a Marine Casualty · 1 dead · activity 1815799
13 August 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3027221
12 October 2007Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 3079043
2 November 2007Routine · role: Involved in a Marine Casualty · 1 dead · activity 3093308
22 March 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4822298
14 February 2026Routine · role: Involved in a Marine Casualty · activity 8315046
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.