MAURY USCG vessel records
← All vessels

SBYC I

Built
1982
Last inspected
2 June 2026
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-55131

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 14 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

2 June 2026 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8387115
13 April 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8347104
23 July 2025 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8192450
22 August 2024 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7986286
6 August 2024 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7975605
23 August 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7774750
19 May 2022 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7460583
21 April 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7435204
25 May 2021 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7203212
21 September 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7062012
30 April 2020 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6945867
22 July 2019 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6758096
11 July 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6475332
20 April 2018 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6395413
28 April 2017 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6132839
2 May 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5866998
18 March 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5835788
16 February 2016 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5815877

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 2 June 2026 Resolved
"The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew." the wood around the engine room compartment in which the fire boy is attached is broken. repair needed. 46CFR177.100
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2026
Resolution: Recieved photos via email of satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 August 2024 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years... Vessel lapsed required inspection dates 31APR2024. Make vessel ready for drydock and internal structures examination. Prior to carriage of passengers/cargo, vessel must receive credit drydock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 August 2024
Resolution: Completed SAT drydock exam
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2023 Resolved
Each ring life buoy must be of an approved type, constructed in accordance with subpart 160.050 of this chapter. At the time of inspection, vessel's grab line on the ring buoy was in-serviceable. In addition, the ring buoy was not equipped with an attached lifeline.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 August 2024
Resolution: Life ring ALL SAT
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 May 2021 Resolved
No means of securing ventilation. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 31 May 2021
Resolved 25 May 2021
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 May 2021 Resolved
First-Aid kit to meet Q spec.
Action required: 705 - Other - as specified
Due 31 May 2021
Resolved 2 June 2021
Resolution: New First-aid kit installed meeting Q spec.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 25 May 2021 Resolved
Non-operational floating water marker light.
Action required: 705 - Other - as specified
Due 31 May 2021
Resolved 2 June 2021
Resolution: New marker light installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 July 2018 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel did not have indicator. Install visual indicator for bilge pump operation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 July 2018
Resolved 25 July 2018
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 April 2017 Resolved
Vessel needs to install first aid kit onboard vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 3 May 2017
Resolution: Operator mounted waterproof firstaid kit on vessel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 April 2017 Resolved
COI needs to be posted onboard vessel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 3 May 2017
Resolution: Operator posted COI on vessel, making it available to all passengers.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 April 2017 Resolved
Replace PFD with valid PFD with vessel name and retroreflective tape
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 3 May 2017
Resolution: Operator properly replaced 02 Type I PFD's.
Documentation › Markings/Placards › Certificate of Number (state)
Issued 28 April 2017 Resolved
Vessel state registration decals attached to the hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 3 May 2017
Resolution: Operator mounted state registration decals to hull of the vessel.
Engineering › Bilge Water Management System › Interface Detector
Issued 2 May 2016 Resolved
AF01- Repair bilge operating light at control station.
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 17 May 2016
Resolution: Vessel installed operating light for their bilge pump.
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 2 May 2016 Resolved
AF02- Properly ground all electrical devices to one common source.
Action required: 705 - Other - as specified
Due 16 May 2016
Resolved 17 May 2016
Resolution: Vessel properly grounded all electrical equipment to common bus bar under their counsel.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 February 2016 Resolved
CONDUCT COI INSPECTION AND DD/ISE INSPECTION PRIOR TO OPERATING W/PAX.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2016

Ownership record