← All vessels
FLUSHING I
FLUSHING I is a 1968 passenger vessel (inspected). The Coast Guard has recorded 26 inspections since 1985, most recently in June 2017, along with 45 deficiencies and 1 operational control.
Records from 1985 to 2017. Most recent: inspection, 6 June 2017.
- Built
- 1968
- Last inspected
- 6 June 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 45 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded4
Years with a record
17 calendar years (1985–2017)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
6 June 2017
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6167181
30 April 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2350083
30 April 2005
Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2360041
1 March 2005
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2301767
13 January 2005
In-Service Inspection
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2276237
10 December 2003
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1968080
21 March 2003
Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1760680
12 April 2002
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1606180
19 September 2001
COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1415715
11 February 2000
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1452630
30 November 1999
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1369430
26 August 1999
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1421727
10 March 1999
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 803241
19 August 1998
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1126700
3 February 1998
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1443965
3 February 1998
MARPOL Annex I Examination · COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1445311
20 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087803
1 June 1995
Re-Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1405716
16 June 1994
Re-Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1407351
8 June 1993
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373860
9 December 1992
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1138799
8 June 1989
COI Inspection · Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201800
7 January 1988
Hull Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1318033
5 November 1987
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1329477
15 April 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1287541
20 February 1985
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 974917
Deficiency record · 45
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 January 2005
Resolved
Prior to carrying passengers, repair aft navigation light, to include wiring.
Lifesaving › Lifebuoys › Not on Board
Issued 13 January 2005
Resolved
Prior to carrying passengers, replace ringbuoy. Ensure to include vessel name, water light with 3ft lanyard and quick release and reflective tape.
Construction/Loadline › Structures › Superstructure
Issued 13 January 2005
Resolved
Prior to carrying passengers, secure piltot station to main deck.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide corrosion resistant tray with approved cover and replace or provide proper connection for battery cables. Secure battery to deck.
Electrical › Electric Supply System (service) › Overcurrent Device
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide overcurrent protection from battery to accesories as close as possible to battery. Not to exceed 30 amps and waterproof.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide 10 adult lifejackets.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 13 January 2005
Resolved
Prior to carrying passengers, replace all lifejackets reflective tape with Type I ( Flexible ) retro-reflective tape.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide safety rail on both port and starboard side.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide required fire extinguishers as per COI
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 January 2005
Resolved
Prior to carrying passengers, replace electrical distribution fuse panel. Panel broken.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 13 January 2005
Resolved
Make proper repairs to keel crossmember amidships under pilot station.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 13 January 2005
Resolved
Prior to carrying passengers, make proper repairs to portside hull forward connection to rail. Hull fractured.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide evidence of enrollment on a drug testing consortium. Ensure new deckhand is also enrolled in the consortium with pre-employmet testing done.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide required deckhand as per COI manning.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide CG approved first aid kit or equivalent..
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 13 January 2005
Resolved
Prior to carrying passengers, provide required distress signals.
Electrical
Issued 19 September 2001
Resolved
Rplace all broken and not conneceted electrical wires leading to navigationlights from pilot console.
Lifesaving
Issued 19 September 2001
Resolved
Replaced all damaged reflective tape on PFDs as marked.
Navigation
Issued 19 September 2001
Resolved
Install missing stern navigation light cover.
Fire Fighting
Issued 26 August 1999
Resolved
PROVIDE SERVICING REPORT FOR TWO B-I EXTINGUISHERS
Lifesaving
Issued 26 August 1999
Resolved
PROVIDE WATERPROOF CONTAINER FOR STORAGE OF FLARES
Navigation
Issued 26 August 1999
Resolved
REPAIR CRACKED STERN LIGHT
Engineering
Issued 3 February 1998
Resolved
REPLACE CRACKED OUTBOARD ENGINE FUSE HOLDER
Navigation
Issued 3 February 1998
Resolved
PROPERLY ATTACH RUNNING LIGHT FIXTURE.
Lifesaving
Issued 3 February 1998
Resolved
PROVIDE A TOTAL OF TWO (2) PORTABLE BATTERY LIGHTS.
Documentation
Issued 3 February 1998
Resolved
PROVIDE OIL POLLUTION PLACARD
Documentation
Issued 3 February 1998
Resolved
PROVIDE RECORD BOOK TO LOG CREW TRAINING AND DRILLS
Documentation
Issued 3 February 1998
Resolved
AFFIX VESSEL NAME TO HULL
Lifesaving
Issued 3 February 1998
Resolved
PROVIDE THREE (3) USCG APPROVED HANDHELD ORANGE SMOKES
Navigation
Issued 3 February 1998
Resolved
PROVIDE AUXILIARY STEERING
Fire Fighting
Issued 3 February 1998
Resolved
PROVIDE A TOTAL OF TWO B-I PORTABLE EXTINGUISHERS.
Construction/Loadline
Issued 3 February 1998
Resolved
SECURE THE BILGE PUMP HOSE WITH DOUBLE CLAMPS
Electrical
Issued 3 February 1998
Resolved
IDENTIFY AND LABEL ALL SWITCHES_x001C_
Lifesaving
Issued 3 February 1998
Resolved
PROVIDE A TOTAL OF 22 ADULT AND 3 CHILD LIFEJACKETS
Documentation
Issued 3 February 1998
Resolved
PROVIDE COPY OF STABILITY LETTER
Construction/Loadline
Issued 3 February 1998
Resolved
SECURE/ATTACH ELECTRICAL SUBMERSIBLE BILGE PUMP TO THE DECK
Lifesaving
Issued 3 February 1998
Resolved
PROVIDE ONE RING BUOY
Lifesaving
Issued 3 February 1998
Resolved
PROVIDE USCG APPROVED FIRST AID KIT
Electrical
Issued 1 June 1995
Resolved
REINSTALL ELECTRICAL SYSTEM WITH PROPER OVERLOAD PROTECTION
Electrical
Issued 1 June 1995
Resolved
SUBMIT CORRECTED ELECTRICAL SYSTEM DRAWING TO MSO SAN JUAN.
Fire Fighting
Issued 1 June 1995
Resolved
SERVICE ONE EACH B-II FIRE EXTINGUISHER.
Fire Fighting
Issued 1 June 1995
Resolved
PROVIDE PROPER BRACKETT AND MOUNT B-II FIRE EXTINGUISHER.
Documentation
Issued 16 June 1994
Resolved
Install chemical testing program in accordance with 46 CFR part 16.
Lifesaving
Issued 20 February 1985
Resolved
REPAIR OR REPLACE RING BUOY FLOAT LIGHT.
Lifesaving
Issued 20 February 1985
Resolved
PROVIDE ONE (1) HAND-HELD RED FLARE DISTRESS SIGNAL
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.