Records from 1985 to 2009. Most recent: inspection, 2 March 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
2 March 2009
Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 3426890
27 June 1994
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1394133
27 December 1993
Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 849841
3 August 1993
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1156146
3 August 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 939942
23 June 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 954606
13 November 1991
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1251551
14 August 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1353234
18 July 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1221802
2 April 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1225780
28 July 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1034436
12 April 1989
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 887061
1 November 1988
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 891469
5 May 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1347133
14 April 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329033
23 March 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1313064
2 May 1986
Deficiency Check · COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1297417
22 May 1985
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 974920
3 May 1985
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1285556
3 May 1985
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1286845
Construction/Loadline
Issued 27 December 1993
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, COMPLETE A DRYDOCK EXAMINATION TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Lifesaving
Issued 3 August 1992
Resolved
MAKE NECESSARY REPAIRS TO VESSELS (12) PERSON BA, WHERE WEB STAPING WORN, _x001C_GRABLINES WORN, OUTER SHELL NEEDS SEALING WHERE WORN AND PAINTED WITH NAME OF VESSEL AND NO. OF PERSONS CERTIFIED FOR ST6ENCILED ON TOP AND BOTTOM OF BA.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Fire Fighting
Issued 3 August 1992
Resolved
HAVE ONE B-2 DRYCHEMICAL FIRE EXTINGUISHER SERVICED AND HYDROSTATICALLY_x001C_ PRESSURE TESTED, SO AS TO HAVE A TOTAL OF TWO SERVICABLE B-2 DRYCHEM EXTINGUISHER ONBOARD.
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Construction/Loadline
Issued 23 June 1992
Resolved
REPLACE THIRD ANGLE FRAMES ON PORT AND STBD SIDES IN BOW COMPARTMENT.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Construction/Loadline
Issued 23 June 1992
Resolved
RECAULK DECK WERE NEEDED.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Construction/Loadline
Issued 23 June 1992
Resolved
REPLACE ROTTEN DECK BEAM IN BOW COMPARTMENT.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Construction/Loadline
Issued 23 June 1992
Resolved
REPLACE DECK PLANKS OVER BEAM WHICH ARE ROTTEN.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Construction/Loadline
Issued 23 June 1992
Resolved
REPLACE OR REPAIR THIRD FRAMES ON PORT AND STBD SIDES OF BOW COMARTMENT_x001C_ WHICH ARE ROTTEN AT CHINE.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Engineering
Issued 23 June 1992
Resolved
REPLACE MISSING FLAME SCREENS TO FUEL TANK VENTS WITH 30X30 MESH SCREEN.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Construction/Loadline
Issued 23 June 1992
Resolved
REPAIR OR REPLACE DECK BEAM AFT IN STEERING COMPARTMENT.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Navigation
Issued 14 August 1991
Resolved
VESSEL MUST REPLACE CHART 12304,TIDE TABLES,COAST PIOLT AND RULES OF ROAD_x001C_ PRIOR TO OPERATION.
Condition: Unknown
Due 14 September 1991
Resolved 30 August 1991
Lifesaving
Issued 14 August 1991
Resolved
VESSEL MUST REPLACE 6 RED AND 6 ORANGE HAND HELD DISTRESS FLARES PRIOR TO_x001C_ OPERATION.
Condition: Unknown
Due 14 September 1991
Resolved 30 August 1991
Navigation
Issued 18 July 1990
Resolved
REPACK AND TIGHTEN THE RUDDER POST PACKING GLAND,PRESENTLY LEAKING PROFUSE-LY,VESSEL RESTRICTED FROM CARRYING PASSENGERS FOR HIRE UNTIL ITEM IS COR- RECTED.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Lifesaving
Issued 18 July 1990
Resolved
RENEW WEB BANDS ON RING BUOY OR REPLACE SAME,PRESENTLY NOT FIT FOR USE,THE VESSEL IS RESTRICTED FROM CARRYING PASSENGERS UNTIL THIS ITEM IS CORRECTED.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Lifesaving
Issued 18 July 1990
Resolved
REPAIR OR REPLACE (4) ADULT PFD'S WHERE SHOULDER STRAPS ARE MISSING, THE VESSEL IS RESTRICTED TO CARRYING 32 TOTAL ADULTS UNTIL THIS ITEM IS COR- RECTED.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Navigation
Issued 18 July 1990
Resolved
PROVIDE A OPERATIONAL TEST OF THE VESSEL'S RADAR PRESENTLY INOPERABLE.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Documentation
Issued 28 July 1989
Resolved
PROVIDE A VALID MARINE OPERATOR'S LICENSE PRESSURE LICENSE EXPIRED APRIL 1987. ORIGINAL COMPLIANCE DATE IS 28AUG89.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Construction/Loadline
Issued 1 November 1988
Resolved
REMOVE (10) TEN CHINE BOLTS FOR FURTHER INSPECTION, (5) FROM THE PORT SIDE AND (5) FROM THE STARBOARD SIDE.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Electrical
Issued 1 November 1988
Resolved
REMOUNT ALL ELECTRICAL WIRING PRESENTLY IN THE BILGE IN WAY OF THE ENGINE SPACE AND BELOW THE WHEELHOUSE.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Electrical
Issued 1 November 1988
Resolved
REMOVE ALL DEAD END ELECTRICAL WIRING FROM COMPARTMENT FORWARD OF ENGINE SPACE.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Engineering
Issued 1 November 1988
Resolved
PROVIDE PROOF THAT FLEXIBLE FUEL LINE ON MAIN DIESEL ENGINE IS COAST GUARD APPROVED OR REPLACE SAME WITH CG APPROVED.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Construction/Loadline
Issued 1 November 1988
Resolved
PROVIDE METALLIC THROUGH HULL FITTINGS IN EXISTING DRAIN HOLES IN THE ENGINE SPACE WHERE MISSING AND PLUG SAME WITH METALLIC PLUG.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Accommodation/Occupational Safety
Issued 1 November 1988
Resolved
REMOVE SLUICE VALVE FROM COLLISION BULKHEAD.
Condition: Unknown
Due 1 November 1988
Resolved 1 November 1988
Construction/Loadline
Issued 22 May 1985
Resolved
MAKE PERMANENT REPAIR TO BUNG HOLE ABOVE WATERLINE PORT SIDE JUST FORWARD OF THE PORT FUEL TANK.
Condition: Unknown
Due 22 May 1985
Resolved 22 May 1985
Construction/Loadline
Issued 3 May 1985
Resolved
RENEW AS ORIGINAL THE ROTTED SIDE PLANK AT THE STARBOARD SIDE FREEING PORT RUNNING AFT.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Accommodation/Occupational Safety
Issued 3 May 1985
Resolved
RENEW EXISTING ROTTED STRIP PLANKED GUNWHALE RAILING. IF RENEW IS NOT IN KIND, SUBMIT PROPOSAL TO [name withheld] PRIOR TO COMMENCING INSTALLATION.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Construction/Loadline
Issued 3 May 1985
Resolved
MAKE PERMANENT REPAIRS TO BUNG HOLE IN BOTTOM.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985
Construction/Loadline
Issued 3 May 1985
Resolved
RENEW ROTTEN GUNWHALE PLANK FROM THE STEM AFT ON BOTH SIDES FOR 10 FEET.
Condition: Unknown
Due 3 May 1985
Resolved 3 May 1985