Records from 1985 to 1995. Most recent: inspection, 10 May 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
10 May 1995
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 865964
11 May 1994
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1169401
9 July 1993
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1154198
12 May 1993
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1143601
22 October 1992
Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1260454
22 July 1992
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1258496
14 May 1992
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1134361
28 June 1991
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1231666
10 June 1991
Deficiency Check
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 934851
9 May 1991
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1219702
10 May 1990
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 904921
26 June 1989
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1200170
12 May 1989
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1039955
19 September 1988
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1195906
8 August 1988
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1344363
10 May 1988
Hull Examination · COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1339361
18 February 1988
Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1330663
21 October 1987
Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1018197
14 May 1987
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1332490
14 May 1986
Re-Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1301327
16 May 1985
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 979487
16 May 1985
COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1332074
Electrical
Issued 12 May 1993
Resolved
PRIOR TO CARRYING PASSENGERS BUT NO LATER THAN 01JUNE93, PROVIDE THIS OFFICE WITH A LETTER THAT THE EXHAUST BLOWER HAS BEEN INTERLOCKED WITH THE IGNITION AND STARTER SYSTEM.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 9 May 1991
Resolved
PROVIDE A BOARDING LADDER SUITABLE FOR USE IN RETRIEVAL OF A PERSON OVERBOARD PRIOR TO 01JUN91. PROVIDE PROOF OF PURCHASE TO THE OFFICER IN CHARGE MARINE INSPECTION UPON RECEIPT.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Lifesaving
Issued 9 May 1991
Resolved
PROVIDE (3) ADDITIONAL APPROVED HAND HELD RED FLARES PRIOR TO 24MAY91. PROVIDE PROOF OF PURCHASE TO THE OFFICER IN CHARGE MARINE INSPECTION UPON RECEIPT.
Condition: Unknown
Due 9 May 1991
Resolved 9 May 1991
Construction/Loadline
Issued 12 May 1989
Resolved
INSTALL A BLOWER IGNITION INTERLOCK SWITCH PRIOR TO USE. NOTIFY THE [name withheld], MN BY LETTER UPON COMPLETION OF THIS ITEM.
Condition: Unknown
Due 12 May 1989
Resolved 12 May 1989
Lifesaving
Issued 12 May 1989
Resolved
PROVIDE 6 RED AND 6 ORANGE FLARES WITHIN 15 DAYS. NOTIFY THE [name withheld] LETTER UPON COMPLETION OF THIS REQUIREMENT, AND PROVIDE A COPY OF THE SALES RECEIPT.
Condition: Unknown
Due 12 May 1989
Resolved 12 May 1989
Engineering
Issued 8 August 1988
Resolved
INSTALL A BLOWER INTERLOCK SWITCH. THE REQUIREMENT FOR A BLOWER HAS BEEN SATISIFED.
Condition: Unknown
Due 8 August 1988
Resolved 8 August 1988
Lifesaving
Issued 14 May 1987
Resolved
REPAIR OR REPLACE THE RING LIFE BUOYS PRIOR TO CARRYING PASSENGERS FOR HIRE
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Construction/Loadline
Issued 14 May 1987
Resolved
REPAIR THE PORT AND STARBOARD PORTLIGHTS IN THE FORWARD COMPARTMENT PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Fire Fighting
Issued 14 May 1987
Resolved
WITHIN FIFTEEN DAYS HAVE THE STORED PRESSURE DRY CHEMICAL FIRE EXTINGUISHER HYDRO TESTED.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987
Accommodation/Occupational Safety
Issued 14 May 1987
Resolved
PROVIDE AND INSTALL A POWER VENTILATION BLOWER IN THE ENGINE / FUEL TANK SPACE IN ACCORDANCE WITH 46 CFR 182.15-45. IN ADDITION, PROVIDE A SUITABLE IGNITION INTERLOCK SWITCH, INSTALLED IN CONJUNCTION WITH THE EXHAUST BLOWERTHIS REQUIREMENT IS TO BE COMPLETED PRIOR TO THE 1988 OPERATING SEASON.
Condition: Unknown
Due 14 May 1987
Resolved 14 May 1987