Records from 1985 to 2026. Most recent: inspection, 23 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 54
23 June 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8410952
14 May 2025
Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8129239
24 April 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8118726
8 July 2024
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7933640
24 April 2023
Deficiency Check · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7671523
10 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7465674
17 June 2021
Deficiency Check · Hull Examination · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7231523
27 May 2020
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6962324
7 October 2019
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6829749
29 April 2019
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6669942
17 May 2018
Annual Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6416073
19 May 2017
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6152669
21 April 2017
Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6131728
2 June 2016
COI Inspection · Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 5894314
24 June 2014
Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4909597
5 June 2012
Deficiency Check · Administrative Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4334471
21 May 2012
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4317757
5 January 2012
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 4206379
6 June 2008
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3228857
3 June 2008
Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3226896
19 July 2007
Re-Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 3034346
13 July 2005
COI Inspection · Hull Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2424246
13 May 2004
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2071173
8 May 2003
Hull Examination · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1788946
29 April 2002
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1611166
13 July 2001
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1067641
2 May 2001
Deficiency Check · Hull Examination · COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1373458
29 June 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1051753
5 May 2000
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1454806
3 May 1999
Re-Inspection · Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 807468
5 May 1998
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1125301
7 May 1997
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1102260
16 April 1997
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1099837
17 May 1996
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1082557
7 May 1996
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1082442
11 May 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 926251
24 April 1995
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 866906
20 May 1994
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1023220
3 May 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 826239
12 April 1993
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1145054
11 May 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 952882
20 April 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 955244
7 May 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 919845
15 April 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1218930
9 May 1990
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 912416
17 April 1990
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1239069
10 May 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1198453
23 March 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1030688
2 May 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1036371
19 April 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1195480
5 May 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1025244
21 May 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1305392
9 May 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1296649
15 May 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 984343
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 23 July 2026
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have a means to reset devices used to automatically shut down ventilation systems and engines. Vessel was unable to override/restart after testing of installed system. 46 CFR 181.420(b)(3)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 August 2026
Resolution: Witnessed proper operation of override/restart of installed system following service by technician.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 23 July 2026
Resolved
A vessel must be provided with an auxiliary means of steering that is of adequate strength, capable of moving the rudder from 15 degrees on one side to 15 degrees on the other side in not more than 60 seconds with the vessel at one-half its maximum service speed ahead, or 7 knots, whichever is greater, and controlled from a location that permits safe maneuvering of the vessel and does not expose the person operating the auxiliary means of steering to personnel hazards during normal or heavy weather operation. A suitable hand tiller may be acceptable as the auxiliary means of steering where satisfactory to the cognizant [name withheld] tiller was found wasted and unable to effectively move the rudder. 46 CFR 182.620 (a)(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2026
Resolved 6 August 2026
Resolution: New emergency steering tiller was intalled and operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 July 2026
Resolved
Gauges to indicate engine cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines located so as to be in view of the operator. Oil pressure gauge at the operating station was inoperable. 46 CFR 182.20-5 (Old T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2026
Resolved 14 August 2026
Resolution: Witnessed operation of oil pressure gauge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 May 2025
Resolved
EACH LIFE RING BUOY ON A VESSEL MUST: BE APPROVED IN ACCORDANCE WITH 160.050 IN SUBCHAPTER Q OF THIS CHAPTER.THE RING LIFE BUOY'S GRAB LINE WAS WEATHERED AND DETERIORATED. REPAIR/REPLACE TO THE SATISFACATION OF THE ATTENDING MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 6 June 2025
Resolution: Life buoy was replaced and has required retro tape.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 May 2025
Resolved
PORTABLE FIRE EXTINGUISHERS SHALL BE INSTALLED AND LOCATED TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. THE INSTALLED PORT SIDE PORTABLE FIRE EXTINGUISHER BRACKET WAS BROKEN AND UNABLE TO SECURE THE REQUIRED PORTABLE FIRE EXTINGUISHER. REPAIR/REPLACE TO THE SATISFACATION OF THE ATTENDING MARINE INSPECTOR. Cite: 46 CFR 181.30-10(b)(OLD-T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 27 May 2025
Resolution: Fire extinguiser bracket was replaced with new bracket, fire extinguisher is now sufficiently secured to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 14 May 2025
Resolved
PLACARDS CONTAINING INSTRUCTIONS FOR THE DONNING AND USE OF THE LIFE JACKETS ABOARD THE VESSEL. VESSEL CARRIED TWO DIFFERENT TYPES OF TYPE I LIFE JACKETS (VEST AND COLLAR), THE VESSELS PROVIDED DONNING INSTRUCTIONS ONLY HAD DONNING INSTRUCTIONS FOR TYPE I (COLLAR) LIFE JACKET. EQUIP VESSEL WITH INSTRUCTIONS FOR BOTH STYLES.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 27 May 2025
Resolution: Vessel now has provided donning instructions for both styles of life jackets.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 14 May 2025
Resolved
THE EMPLOYER SHALL PROVIDE AN EMPLOYEE ASSISTANCE PROGRAM (EAP) FOR ALL CREWMEMBERS. OPERATOR COULD NOT PROVIDE EVIDENCE OF HAVING AN ESTABLISHED EAP. PROVIDE EVIDENCE THAT WOULD SHOW THAT THE COMPANY HAS AN EAP, OR CREATED AN EAP TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 May 2025
Resolved 27 May 2025
Resolution: Vessel provided proper documentation for EAP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 July 2024
Resolved
Wiring joints and splices shall be mechanically secure and made in a junction boxes. Multiple joints and splices are exposed the inclement weather and are not in junction boxes. This issue must be addressed/corrected.
46 CFR 183.05-50(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 26 July 2024
Resolution: Received objective Evidence of the wires inside a junction box.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 July 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. Vessel's first-aid kit was expired, must be replaced.
46 CFR 184.710
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 12 July 2024
Resolution: Received objective evidence (photo) from Rep showing issue has been corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 July 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces. Vessel's visual alarm did not work, must be replaced/repaired or removed.
46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 26 July 2024
Resolution: Received objective Evidence showing an active visible/audible bilge alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 8 July 2024
Resolved
A vessel on a lakes, bays, and sounds, or rivers route must carry 03 hand red flare and 03 hand orange smoke distress signals approved in accordance with § 160.021 in subchapter Q of this chapter. Vessel only had 03 hand red flares on board, must maintain an additional 03 distress signals on board.
46 CFR 180.6(b)(1)&(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 July 2024
Resolved 12 July 2024
Resolution: Received objective evidence (photo) from Rep showing issue has been corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 July 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. If any of the equipment or records have not been properly maintained, a qualified servicing facility must perform the required inspections, maintenance procedures, and hydrostatic pressure tests. Maintenance was being conducted but not documented in a log. This corresponds with Monthly maintenance under NFPA 10.
46CFR176.810(b)(2)(iv)
Action required: 10 - Deficiency Rectified
Due 8 July 2024
Resolved 8 July 2024
Resolution: Corrected on the spot with Rep with education.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 July 2024
Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Drills was being conducted but not documented in a log.
46 CFR 185.520(f)
Action required: 10 - Deficiency Rectified
Due 8 July 2024
Resolved 8 July 2024
Resolution: Corrected on the spot with Rep with education.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2023
Resolved
Each fixed power bilge pump must be self priming. It must be permanently connected to the bilge. Fwd and aft Bilge pumps were not mounted/secured to the bilge/hull.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 7 May 2023
Resolution: Operator Permanantly affixed bilge pumps to the bilge as required in 46CFR182.520
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 April 2023
Resolved
A submersible electric bilge pump may be used as a power bilge pump provided a positive Shutoff valve is installed at the hull penetration. The fwd bilge pump does not have a positive shutoff valve installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 7 May 2023
Resolution: Operator installed valve on the discharge hose before the hull on the fwd Electric Bilge pump.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 24 April 2023
Resolved
Small vessels of the open launch type, and other vessels not specifically covered elsewhere in this section shall have such rails or equivalent protection as considered necessary by the officer in charge, marine inspections. Aft STB rail is loose and needs be tightened.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 7 May 2023
Resolution: Operator tightened Aft railing to the satisfaction of the attending Marine inspector.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 24 April 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions
to be taken in the event of fire, heavy weather, or man
overboard conditions. Vessel does not have sufficient emergency instructions posted in case of an emergency.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 7 May 2023
Resolution: Vessel now has emergency instructions on board for passengers.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 April 2023
Resolved
At each initial hull inspection and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. A hole was found on the fwd STBD side weather-deck leading to the fwd compartment. Repair as necessary to maintain watertight integrity, to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 7 May 2023
Resolution: Operator filled the hole in question to the satisfaction of the attending Marine inspector.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 April 2023
Resolved
A Space containing diesel machinery must be fitted with adequate means such as ducts to provide sufficient air for proper operation of main engine. A 1.5 inch in diameter hole was found on the port side engine room ventilation natural supply duct. Renew as necessary to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2023
Resolved 7 May 2023
Resolution: Operator used flex tape to patch a hole in the natural exhaust ventilation pipe.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 10 June 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel did not have appropriate means to secure the ventilation.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 23 June 2022
Resolution: Means to secure ventilation provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 June 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. The number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 10 June 2022
Resolution: PFD's provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 June 2022
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. Exhaust hose was missing double clamps on both ends
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 23 June 2022
Resolution: Hose double clamped.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 June 2022
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. Drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include Date of the drill and training; and general description of the drill scenario and training topics. Operator did not documented their drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2022
Resolved 23 June 2022
Resolution: Drills documented.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 June 2021
Resolved
Except as provided in §173.17, no person may use a vessel to which this part applies. The vessel state registration was not valid.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 June 2021
Resolution: Operator provided evidence of valid state registration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2021
Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. The ringbuoy grabline and waterlight line is dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 27 July 2021
Resolution: Confirmed a new ring buoy was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2021
Resolved
Ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. The Ring life buoy did not have the retroreflective on it.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2021
Resolved 27 July 2021
Resolution: Confirmed the tape was installed.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 June 2021
Resolved
Green light on the starboard side and a red light on the port side each showing an unbroken light over an arc of the horizon of 112.5 degrees and so fixed as to show the light from right ahead to 22.5 degrees abaft the beam on its respective side. The starboard side navigational light was not meeting the arc requirement for a side
light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2021
Resolved 27 July 2021
Resolution: Confirmed light was replaced.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2021
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, The bilge forward of the control station is water logged with an unknown amount of damage. Determine the extent of the damage, submit a plan proposal for approval and execute the approved plan.46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 14 July 2021
Resolution: Attended the vessel and determined that the bilge damage was not structural.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 June 2021
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens. The vessel's vent does not have a flame screen. Install a flame screen on the vent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 14 July 2021
Resolution: Observed that a flame screen was installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2020
Resolved
A vessel must carry one floating waterlight. The waterlight that was onboard the vessel did not have a battery installed. Vessel is restricted to daytime operations until the waterlight is repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 1 June 2020
Resolution: Operator purphased new battery for floatlight
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 27 May 2020
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level. The high level alarm on the vessel was inoperable
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2020
Resolved 1 June 2020
Resolution: Operator fixed the bilge alarm.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 May 2018
Resolved
Affix waterlight to ring life buoy--Vessel limited to daytime operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 May 2018
Resolved 6 June 2018
Resolution: Water light affixed to ring life buoy.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 17 May 2018
Resolved
Mark hailing port on stern of vessel.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2018
Resolved 6 June 2018
Resolution: Hailing port marked on stern of vessel.
Engineering › Bilge Water Management System › Not Operational
Issued 17 May 2018
Resolved
Prove proper operation of bilge high water level alarm.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 May 2018
Resolved 6 June 2018
Resolution: Bilge high water level alarm remounted and operational.
Engineering › Bilge Water Management System › Not Installed
Issued 19 May 2017
Resolved
Install bilge high water level alarm in the ENG room.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2017
Resolved 19 May 2017
Resolution: Installed bilge high water alarm.
Documentation › Logs/Records › Drug Test Records
Issued 19 May 2017
Resolved
Provide approved employee list from current drug consortium.
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 30 May 2017
Resolution: Provided approved employee list from current drug consortium.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 May 2017
Resolved
Replace forward mast headlight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 30 May 2017
Resolution: Repaired forward mast head light.
Engineering › Fuel Oil Service System › Valve
Issued 19 May 2017
Resolved
Label fuel shut off on the deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 30 May 2017
Resolution: Label provided for fuel shut off.
Engineering › Bilge Water Management System › Piping
Issued 19 May 2017
Resolved
Replace the tube on the hand bilge pump.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 30 May 2017
Resolution: Replaced tube on hand bilge pump.
Stability › Watertight Integrity › General
Issued 19 May 2017
Resolved
Re-Install the cleat on the port bow, to fill in the 4 empty holes in the hull.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 May 2017
Resolved 30 May 2017
Resolution: Reinstalled cleat on port bow.
Navigation › Piloting/Steering › US Coast Pilot
Issued 2 June 2016
Resolved
Vessel is missing required pubs. Provide all reaquired pubs.
Due 16 June 2016
Resolved 27 June 2016
Resolution: Pubs have been provided on board.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 June 2014
Resolved
First aid kit had expired meds in it. Provide contents within the expiration date for the first aid kit.
Action required: 705 - Other - as specified
Due 8 July 2014
Resolved 9 July 2014
Resolution: First ait kit was replaced with a new USCG approved kit.
Navigation › Piloting/Steering › Marine Charts
Issued 24 June 2014
Resolved
Provide charts and pubs for their area of operation.
Action required: 705 - Other - as specified
Due 8 July 2014
Resolved 9 July 2014
Resolution: Charts and pubs for area were placed on vessel.
Fire Fighting › Fire Bucket › Availability
Issued 24 June 2014
Resolved
Provide three 2 1/2 gallon fire buckets.
Action required: 705 - Other - as specified
Due 8 July 2014
Resolved 9 July 2014
Resolution: Additional fire buckets were placed on vessel.
Documentation › Certificates/Documents › Stability Letter
Issued 12 December 2011
Resolved
The vessel's owner/operator has not requested an initial or updated stability letter or has not certified compliance with the revised stability criteria for assumed average weight per person (AAWPP) of 185 pounds. Based upon a weight ratio calculation, the vessel's capacity is therefore limited to: 16 persons (passengers and crew). 46 CFR 170.090
Due 1 June 2012
Resolved 5 June 2012
Resolution: Owner has opted to reduce persons on board tp 15.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 3 June 2008
Resolved
Properly mark all PFD's with vessel name.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 6 June 2008
Resolution: Corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 June 2008
Resolved
Remove dead-ended wires from under port and stbd passenger seats.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 6 June 2008
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 19 July 2007
Resolved
Prove proper operation of fixed fire extinguishing system.
Condition: Improper Installation
Due 2 August 2007
Resolved 27 July 2007
Resolution: Witnessed proper operation. ALL SAT.
Engineering › Fuel Oil Service System › Hose
Issued 19 July 2007
Resolved
Install proper USCG approved fuel lines from fuel tank to engine.
Condition: Improper Installation
Due 2 August 2007
Resolved 26 July 2007
Resolution: Proper fuel lines installed.. ALL SAT.
Accommodation/Occupational Safety › Ventilation › General
Issued 19 July 2007
Resolved
Replace air intake piping to engine compartment.
Condition: Unknown
Due 2 August 2007
Resolved 30 July 2007
Resolution: Air intake piping to engine compartment replaced. ALL SAT.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 July 2007
Resolved
Prove proper operation of bilge alarm system.
Condition: Unknown
Due 2 August 2007
Resolved 26 July 2007
Resolution: Witnessed proper operation of bilge alarm system. ALL SAT.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 19 July 2007
Resolved
Replace worn cutlass bearing.
Condition: Unknown
Due 19 July 2007
Resolved 19 July 2007
Resolution: Corrected on the spot. ALL SAT
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 May 2004
Resolved
Install vessel name, retro tape, and lifeline to ring buoy.
Action required: 705 - Other - as specified
Due 27 May 2004
Resolved 14 May 2004
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 13 May 2004
Resolved
Properly repair engine shutdown for fixed fire system (fireboy).
Action required: 705 - Other - as specified
Due 27 May 2004
Resolved 14 May 2004
Engineering › Steering Gear System › Rudder
Issued 13 May 2004
Resolved
Tighten rudder packing.
Action required: 705 - Other - as specified
Due 27 May 2004
Resolved 13 May 2004
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 May 2004
Resolved
Provide expanded Yacht club policy on drug testing program; to include but not limited too, Pre-employment, random, post incident testing as well as info on employee assistance program or enroll company personnel involved with vessel operations into a drug consortium.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2005
Resolved 13 July 2005
Resolution: Vessel has been sold. New owner has satisafctory drug/alcohol testing program.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 8 May 2003
Resolved
Provide servicing for fixed fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 14 May 2003
Resolution: Received fax copy of servicing certificate for fixed system.
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 May 2003
Resolved
Provide one additional adult Type I PFD. Until cleared, passenger capacity is reduced to 20. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 14 May 2003
Resolution: Received fax copy of invoice for new PFD.
Lifesaving › Lifebuoys
Issued 8 May 2003
Resolved
Install lanyard with clip for waterlight on ring life buoy. LEGACY COMPONENT DESC: Stowage
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 June 2003
Resolved 14 May 2003
Resolution: The lanyard and clip were fabriacted and installed on ring buoy.
Engineering › Fuel Oil Service System
Issued 30 April 2002
Resolved
Replace the worn fuel fill hose. LEGACY COMPONENT DESC: Hose
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2002
Resolution: Hose replaced.
Engineering › Bilge Water Management System
Issued 30 April 2002
Resolved
Repair the bilge piping system in the engine compartment. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2002
Resolution: Bilge piping system repaired.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 April 2002
Resolved
Have the fixed fire fighting system in the engine compartment properly serviced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2002
Resolution: System properly serviced.
Engineering › Bilge Water Management System
Issued 30 April 2002
Resolved
Provide a portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2002
Resolution: Bilge pump provided.
Communications › Radio Communications
Issued 30 April 2002
Resolved
Prove proper operation of the VHF radio. LEGACY COMPONENT DESC: VHF Radiotelephone
Due 13 May 2002
Resolved 22 May 2002
Resolution: VHF comms established.
Documentation
Issued 2 May 2001
Resolved
Provide proof of enrollment in a Coast Guard approved Drug Testing Program.
Condition: Unknown
Due 2 May 2001
Resolved 2 May 2001
Navigation
Issued 2 May 2001
Resolved
Repair/Replace port running light
Condition: Unknown
Due 5 May 2001
Resolved 5 May 2001
Lifesaving
Issued 2 May 2001
Resolved
stencil adult and child PFD markings on PFD stowage container.
Condition: Unknown
Due 5 May 2001
Resolved 5 May 2001
Construction/Loadline
Issued 5 May 2000
Resolved
Tapered sea cock for main engine cooling frozen in the open position. Freeup sea valve and prove proper operation.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Lifesaving
Issued 5 May 2000
Resolved
Ring buoy beckets torn and rotted, buoy missing retro-reflective tape. Renew ring buoy.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Lifesaving
Issued 5 May 2000
Resolved
Battery tie down strap buckle broken. Renew tie down strap.
Condition: Unknown
Due 5 May 2000
Resolved 5 May 2000
Lifesaving
Issued 7 May 1996
Resolved
PROVIDE AND PROPERLY MOUNT LIFEJACKET DONNING AND EMERGENCY INSTRUCTION PLACARDS.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Documentation
Issued 7 May 1996
Resolved
PRIOR TO OPERATION, PROVIDE A VALID STATE REGISTRATION.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 7 May 1996
Resolved
REPLACE THE RING LIFE BUOY WITH AN APPROVED DEVICE, LINE AND MARKINGS.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996
Resolved
INSTALL APPROVED 30X30 WIRE MESH FLAME SCREEN IN THE FUEL TANK VENT LINE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Engineering
Issued 7 May 1996
Resolved
RESTENCIL THE EMERGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Accommodation/Occupational Safety
Issued 11 May 1995
Resolved
TIGHTEN RAILING MOUNTS ON STARBOARD QUARTER WHERE LOOSE.
Condition: Unknown
Due 11 May 1995
Resolved 18 May 1995
Lifesaving
Issued 11 May 1995
Resolved
PLACE RETROREFLECTIVE TAPE ON CHILD SIZED PFD, WHERE MISSING.
Condition: Unknown
Due 11 May 1995
Resolved 18 May 1995