Inspection history · 18
5 March 2026
COI Inspection · Vessel Attendance · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8320569
24 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8117935
11 March 2025
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8091286
18 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7897621
14 April 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7659675
16 March 2023
Deficiency Check · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7652080
13 April 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7430217
14 April 2021
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7149443
2 March 2021
Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7149372
26 June 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7005284
7 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6936414
17 March 2020
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6880575
15 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6638551
18 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6358726
27 March 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6358718
26 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6132449
15 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5832795
19 February 2016
COI Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5818359
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 April 2026
Resolved
Obtain one additional fire bucket with lanyard and label as "FIRE BUCKET"
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 17 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 March 2026
Resolved
Repair bilge high water alarm at operating station.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 17 April 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 5 March 2026
Resolved
Obtain 48 doses of non-expired aspirin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2026
Resolved 17 April 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 24 April 2025
Resolved
First aid kit had expired Motion Sickness Tablets and Aspirin. O/O replacing the first aid kit in kind by end of day today.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 April 2025
Resolved 24 April 2025
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 April 2025
Resolved
Vessel missing portable light in the vicinity of the operating station. O/O will replace in kind by end of day today.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 24 April 2025
Resolved 24 April 2025
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 24 April 2025
Resolved
The railing on the starboard side of the vessel is equipped with 12" long pipe patch around the railing for added protection to the railing while hauling mooring ball lines. The pipe patch was rusted through with exposed jagged edges, causing passenger risk. O/O to eliminate the rusted edges to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2025
Resolved 29 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 March 2023
Resolved
Shaft bearing was worn past allowable limits. Replace shaft bearing. 46CFR176.670.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 30 March 2023
Resolution: MI observed shaft bearing was replaced with a new shaft bearing.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 March 2023
Resolved
Below the waterline appendages shall be watertight. Starboard side exhaust discharge appendage sealant was wasted. Re-bed or seal appendage to maintain watertight integrity. 46CFR176.610
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 30 March 2023
Resolution: Starboard side exhaust discharge appendage was resealed to maintain watertight integrity.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 16 March 2023
Resolved
A penetration in a watertight bulkhead must be as high and as far inboard in the bulkhead as practicable, and made watertight. The engine space, the forward bulkhead had a penetration on the port side that was not watertight. 46CFR179.320(c).
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 14 April 2023
Resolution: O/O sucured hole from ER to forward compartment.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 16 March 2023
Resolved
Deck drainage is permitted to flow overboard from the weather deck tight deck. The scuppers for the vessel must be fitted with a non-return device. The port forward non-return device was not operational. Repair or replace device to become functional. 46CFR178.440; SLIS Policy 01-13.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 30 March 2023
Resolution: The port forward non-return device was operational.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 16 March 2023
Resolved
The deck forward of the engine hatch was wasted. Repair deck. 46CFR177.300
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 14 April 2023
Resolution: The deck was repaired to the satisifaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2023
Resolved
Vessel must be equipped with an auxiliary means of steering. The tiller used as auxiliary steering was able to turn the rudder. 46CFR182.620.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 April 2023
Resolved 14 May 2023
Resolution: Witnessed proper operation of tiller
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 April 2022
Resolved
Grab lines for ring buoy were wasted upon inspection instructed rep to renew.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2022
Resolved 13 April 2022
Resolution: Renewed and installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 April 2021
Resolved
The life buoy water light was not of the required type. The vessel had purchased a waterlight with an on/off switch which did not automatically activate. Required vessel to replace waterlight.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2021
Resolved 28 April 2021
Resolution: Replaced waterlight with correct model.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 14 April 2021
Resolved
The vessels first aid kit had expired items. Required vessel to replace expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 May 2021
Resolved 1 May 2021
Resolution: Vessel has replaced expired items.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 26 June 2020
Resolved
No Coast Pilot or USCG Light List available for refrence.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2020
Resolved 10 July 2020
Resolution: Printed from NAVCEN and NOAA for applicable areas. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 June 2020
Resolved
Shaft packing had moderate leak when underway.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2020
Resolved 10 July 2020
Resolution: Video sent of shaft packing underway. Leak observed was minimal.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 June 2020
Resolved
No retro reflective tape installed on the type IV life ring.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2020
Resolved 10 July 2020
Resolution: Retro reflective tape installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 June 2020
Resolved
Fire buckets were 5 gallon buckets and tangled in the vessel's storage space not available for an emergency quickly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2020
Resolved 10 July 2020
Resolution: holes were drilled mid way through the buckets to reduce the 5 gal capacity and untangled and snap hooks were installed for quick deployment in an emergency.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2020
Resolved
PFE required O/B was identified in the guage attached as "discharged"
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 26 June 2020
Resolved 26 June 2020
Resolution: Company had a spare PFE tagged and inspected by an approved facility installed for operations.