MAURY USCG vessel records Sign in
← All vessels

INT'L CAVALIER

INT'L CAVALIER is a 1983 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1983, most recently in June 2014, along with 66 deficiencies.

Records from 1983 to 2014. Most recent: inspection, 19 June 2014.

Built
1983
Last inspected
19 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD7263
Flag
UNITED STATES
367093010, 367184050 (licence lapsed)
Maury page id
psix-55169

Inspections, by type

…with no type recorded15
Years with a record 25 calendar years (1983–2014)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it92 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD7263MMSI 367184050 · expired · voluntarily equipped · granted 1 May 2007, cancelled 1 July 2017 · licensed under a name not among this hull’s recorded names (not shown)
WDC8785MMSI 367093010 · expired · voluntarily equipped · granted 14 February 2006, cancelled 16 April 2016 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

19 June 2014 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4893098
27 June 2012 Administrative Inspection · Deficiency Check · Ballast Water Examination · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4368693
23 February 2012 DAPI Audit
Administrative · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 4250036
5 March 2009 Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3442999
19 May 2008 Periodic Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3211207
17 May 2007 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2933305
28 February 2007 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2879103
21 February 2006 Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2586488
7 July 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2418121
7 July 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2418425
19 May 2005 Ballast Water Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2368727
3 February 2005 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2286076
14 May 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2067314
21 May 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1798121
25 February 2003 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1749195
7 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1597264
17 October 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 230788
15 July 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 638516
10 May 2001 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 189547
15 March 2001 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1064594
22 February 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376507
17 July 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 819823
12 May 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1049596
24 April 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1048799
7 April 2000 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421834
16 April 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789695
18 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454643
11 February 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421608
21 August 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 132665
13 February 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1372199
3 September 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388351
25 June 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1406146
16 January 1997 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 754437
23 December 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 196541
8 July 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1413018
25 January 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 752635
11 January 1996 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 196542
15 August 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371140
8 August 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1358868
14 July 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1183489
18 October 1994 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 860679
19 August 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1396166
1 September 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399917
1 September 1993 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399918
13 August 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1153617
11 January 1990 Deadweight Survey
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 909694
19 June 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1004390
6 June 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 994533
29 January 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1303509
29 January 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1309156
22 July 1985 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1289722
12 July 1985 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 981554
27 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 976612
30 June 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967210

Deficiency record · 66

Electrical › Electric Generation Source (service) › Generator
Issued 27 June 2012 Resolved
Both port and stbd generator windings were dirty.
Action required: 705 - Other - as specified
Due 27 July 2012
Resolved 2 July 2012
Resolution: Both armatures and windings were cleaned.
Engineering › Compressed Air System (control) › Compressor
Issued 17 May 2007 Resolved
Guards for engine room's compressor were not installed/missing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 23 May 2007
Documentation › Logs/Records › Logbook (official)
Issued 17 May 2007 Resolved
Steering tests and loss of steering drills not logged.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2007
Resolved 23 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 May 2007 Resolved
Donning instruction placards not provided for all types on board.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2007
Resolved 23 May 2007
Stability › Watertight Integrity › General
Issued 17 May 2007 Resolved
Flood avioidance vent closure devices not installed at bow and ballast tank vents located on forepeak
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 May 2007
Resolved 23 May 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 17 May 2007 Resolved
Stove not attached to vessel. Clasp not installed to prevent rough seas opening of oven door
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 23 May 2007
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 17 May 2007 Resolved
Anchor rope not capable of ready attachment to anchor. Anchor attachment to vessel was corroded and required tools not readily avalible at the station.
Action required: 705 - Other - as specified
Due 17 June 2007
Resolved 23 May 2007
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 May 2007 Resolved
Emergency fuel shutoff not labled
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2007
Resolved 23 May 2007
Communications › Radio Communications › EPIRB
Issued 17 May 2007 Resolved
EPIRB registration displayed incorrect radio call sign.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2007
Resolved 23 May 2007
Deck/Cargo › Ballast › Valves
Issued 17 May 2007 Resolved
Direction of operation not labeled at ballast water reach rod handle.
Action required: 705 - Other - as specified
Resolved 18 May 2007
Engineering › Bilge Water Management System › Valve
Issued 19 May 2005 Resolved
Provide check valve at some accessible point in the bilge lines as required. Prior to next inspection.
Action required: 705 - Other - as specified
Due 22 February 2006
Resolved 21 February 2006
Resolution: Witnessed proper installation of check valve.
Fire Fighting › Fire Pumps › Capacity
Issued 1 March 2005 Resolved
Show proper operation of Fire Pump.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2005
Resolved 1 March 2005
Resolution: Fire pump obtained 70 psi.
Lifesaving › Buoyant Apparatus
Issued 21 May 2003 Resolved
Provide proof of servicing for all life floats onboard. LEGACY COMPONENT DESC: Lifefloats
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Communications › Radio Communications › EPIRB
Issued 21 May 2003 Resolved
Renew hydrostatic release and provide proof of servicing of EPIRB.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Construction/Loadline › Structures › Manhole
Issued 21 May 2003 Resolved
Make repairs to forward void manhole cover.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 21 May 2003 Resolved
Make anchor ready for use.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Construction/Loadline › Structures › End Bulkhead
Issued 21 May 2003 Resolved
Make repairs by welding bulkhead holes on port generator room stairwell and forward engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Fire Fighting › Fire Pumps › Pressure
Issued 21 May 2003 Resolved
Provide properly operating fire pump to achieve 60 psi.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 May 2003 Resolved
Renew eleven (11) of the approved type lifejackets.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 May 2003 Resolved
Provide one (1) emergency light for lower crew's quarters escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 May 2003 Resolved
Stencil lower crew's quarters escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Communications › Alarms/Indicators
Issued 21 May 2003 Resolved
Renew port main engine lube oil pressure gauge at operating station. LEGACY COMPONENT DESC: Lube Oil Pressure Indicator
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 May 2003 Resolved
Provide securing device for operating station electrical panel door.
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 22 May 2003
Operations/Management › Navigation Safety
Issued 21 May 2003 Resolved
Make repairs to starboard aft window on operating station. LEGACY COMPONENT DESC: Windows
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Switchboard
Issued 21 May 2003 Resolved
Provide switchboard electrical safety mat.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Fire Fighting › Ventilation Systems › Ducts
Issued 21 May 2003 Resolved
Provide closure device for paint locker ventilation.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 May 2003 Resolved
Renew first aid kit.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Fire Fighting › Portable Foam Applicators
Issued 21 May 2003 Resolved
Provide portable foam applicator. LEGACY COMPONENT DESC: Portable Foam Applicators
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 June 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service)
Issued 21 May 2003 Resolved
Provide protective cover for wiring strip bar at operating station. LEGACY COMPONENT DESC: Bus Bar Connection
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2003 Resolved
Remove all dead-end wire from operating station.
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 22 May 2003
Stability › Watertight Integrity
Issued 21 May 2003 Resolved
Replace gaskets on 01 deck, galley, ventilation motor space and aft entry watertight doors. LEGACY COMPONENT DESC: Watertight Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 May 2003 Resolved
Provide protective cover for ventilation motor power supply.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 21 May 2003 Resolved
Provide means of collecting dryer exhaust lint.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Stability › Watertight Integrity
Issued 21 May 2003 Resolved
Adjust all watertight doors and hatches. LEGACY COMPONENT DESC: Watertight Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 21 May 2003 Resolved
Properly label lifejacket stowage lockers.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 June 2003
Resolved 22 May 2003
Stability › Watertight Integrity
Issued 21 May 2003 Resolved
Provide securing dog to port side porthole in captain's cabin. LEGACY COMPONENT DESC: Port Holes
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 22 May 2003
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 21 May 2003 Resolved
Make repairs to rack lights in upper and lower crew's quarters.
Action required: 705 - Other - as specified
Due 21 June 2003
Resolved 22 May 2003
Documentation
Issued 7 March 2002 Resolved
FCC RADIO LICENSES NOT PROVIDE FOR ALL PERSONNEL OPERATING MARINE RADIOS. LEGACY COMPONENT DESC: FCC RADIO LICENSE
Due 21 March 2002
Resolved 21 March 2002
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 March 2002 Resolved
ONE NOT UNDER COMMAND LIGHT NOT PROVIDED.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2002
Resolved 7 March 2002
Construction/Loadline › Structures › Door
Issued 7 March 2002 Resolved
ENGINE ROOM WATERTIGHT DOOR OUT OF ADJUSTMENT.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2002
Resolved 7 March 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 March 2002 Resolved
EMERGENCY LIGHT NOT INSTALLED AT EMERGENCY ESCAPE IN ENGINE ROOM.
Condition: Unknown
Due 11 March 2002
Resolved 11 March 2002
Fire Fighting › Nozzles › Number
Issued 7 March 2002 Resolved
AN APPROVED FOAM NOZZLE NOT PROVIDED.
Condition: Unknown
Due 11 March 2002
Resolved 11 March 2002
Navigation
Issued 7 April 2000 Resolved
PROVIDE UPDATES TO NAVIGATION PUBLICATIONS AS NECESSARY.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Electrical
Issued 7 April 2000 Resolved
REMOVE NON-EXPLOSIVE PROOF LIGHT AND SWITCH/OUTLET FROM PAINT LOCKER.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Fire Fighting
Issued 7 April 2000 Resolved
PROVIDE FIRE FIGHTING EQUIPMENT OR PROCEDURES TO PROVIDE EQUIPMENT IAW 49 CFR 176.315 FOR THE TRANSPORT OF MARINE PORTABLE TANKS.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Navigation
Issued 7 April 2000 Resolved
LOCATE/REPAIR LEAK FROM AUTO PILOT WIRE RUN PIPING IN WAY OF RUDDER ROOM.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Navigation
Issued 7 April 2000 Resolved
DOUBLE NUT PORT RUDDER PIN OR INSTALL COTTER PIN.
Condition: Unknown
Due 10 April 2000
Resolved 10 April 2000
Navigation
Issued 7 April 2000 Resolved
INSTALL AND PROVE PROPER OPERATION OF RUDDER ANGLE INDICATORS AT BOTH OPERATING STATIONS.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Documentation
Issued 7 April 2000 Resolved
PROVE 50% OF CREW HAS REQUIRED CPR TRAINING AND CERTIFICATION.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Electrical
Issued 7 April 2000 Resolved
INSTALL JUNCTION BOX FOR OR REMOVE 220V WIRE BEHIND WASHER/DRYER.
Condition: Unknown
Due 7 April 2000
Resolved 7 April 2000
Engineering
Issued 18 March 1999 Resolved
Demonstrate proper operation of both generator overspeeds to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Construction/Loadline
Issued 18 March 1999 Resolved
Install high bilge alarm sensors in rudder room and engine room with visualand audible indicator at the operating station to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 18 March 1999
Resolved 18 March 1999
Engineering
Issued 19 August 1994 Resolved
REPAIR AIR CONTROL VALVE ON PILOT HOUSE CONTROL THROTTLES IN WHEELHOUSE.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Construction/Loadline
Issued 19 August 1994 Resolved
STENCIL "DOOR TO REMAIN CLOSED AT ALL TIMES EXCEPT WHEN USED FOR TRANSIT" ON BULKHEAD DOOR AT FRAME 30 IN ACCORDANCE WITH VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Construction/Loadline
Issued 19 August 1994 Resolved
REMOVE ALL OILY WASTE FROM BILGES.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Electrical
Issued 19 August 1994 Resolved
PLACE DRIP SHIELD OVER CONSTAVOLT BATTERY CHARGER IN GENERATOR ROOM.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Accommodation/Occupational Safety
Issued 19 August 1994 Resolved
REROUTE DRAIN FROM WASHING MACHINE TO DISCHARGE INTO HOLDING TANK VICE BILGES.
Condition: Unknown
Due 19 August 1994
Resolved 19 August 1994
Documentation
Issued 1 September 1993 Resolved
Obtain and post vessel's stability letter. Vessel is not to operate until corrected.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Documentation
Issued 1 September 1993 Resolved
Provide vessel with a valid FCC Radiotelephony Certificate. Vessel is not to operate until this requirement is corrected.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Electrical
Issued 1 September 1993 Resolved
Provide copies of approved electrical plans, USCG approved plans.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Lifesaving
Issued 1 September 1993 Resolved
Conduct a fire and drill in the presence of the U. S. Coast Guard.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Engineering
Issued 1 September 1993 Resolved
Repair flame screens.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Lifesaving
Issued 1 September 1993 Resolved
Provide vessel with nine (09) adult PFD's. Vessel may only carry twenty- seven (27) total persons on board until item is corrected.
Condition: Unknown
Due 15 September 1993
Resolved 15 September 1993
Lifesaving
Issued 12 July 1985 Resolved
SUPPLY 21 MAN DETACHABLE LINK FOR LIFE FLOATS.
Condition: Unknown
Due 12 July 1985
Resolved 12 July 1985
Electrical
Issued 12 July 1985 Resolved
REPAIR ELECTRICAL JURY RIG IN STEERING ROOM.
Condition: Unknown
Due 12 July 1985
Resolved 12 July 1985
Fire Fighting
Issued 12 July 1985 Resolved
FURNISH PORTABLE HAND FIRE AND BILGE PUMP.
Condition: Unknown
Due 12 July 1985
Resolved 12 July 1985

Ownership record