JIM CUNNINGHAM is a 1982 mobile offshore drilling unit. The Coast Guard has recorded 60 inspections since 1985, most recently in February 2016, along with 217 deficiencies and 1 casualty investigation in 2002.

Records from 1985 to 2016. Most recent: inspection, 19 February 2016.

Built
1982
Last inspected
19 February 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
MARSHALL ISLANDS
366686000 (licence lapsed)
Maury page id
psix-55170

Inspections, by type

…with no type recorded12
Years with a record 21 calendar years (1985–2016)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it7977 - Regulatory (Subpart C or D), Gross Ton
12647 - Convention (Subpart B), Gross Ton
5866 - Regulatory (Subpart C or D), Net Ton
3794 - Convention (Subpart B), Net Ton
15469 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KSHXMMSI 366686000 · expired · compulsorily equipped · granted 3 April 1998, cancelled 7 June 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MAERSK PACER Towing Vessel · MISLE 491248 · 15 December 1998 · activity 50432

Inspection history · 60

19 February 2016 Deficiency Check
Physical examination · Activities Europe · Activity 5818023
24 June 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2401275
17 June 2003 Administrative Inspection
Administrative · Activities Europe · Activity 1819522
21 October 2002 Annual Inspection
Physical examination · Activities Europe · Activity 1671656
5 January 2002 Type not recorded
No type recorded · Activities Europe · Activity 1480579
29 November 2001 COI Inspection · Hull Examination
Physical examination · Activities Europe · Activity 1366552
5 February 2001 Deficiency Check
Physical examination · Activities Europe · Activity 1058700
3 October 2000 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1054546
2 October 2000 COI Inspection
Physical examination · Activities Europe · Activity 1379216
11 February 2000 Deficiency Check
Physical examination · Activities Europe · Activity 814205
3 December 1999 Deficiency Check
Physical examination · Activities Europe · Activity 809862
24 October 1999 Re-Inspection · Hull Examination
Physical examination · Activities Europe · Activity 1402974
15 December 1998 Type not recorded
No type recorded · Activities Europe · Activity 50432
7 October 1998 COI Inspection
Physical examination · Activities Europe · Activity 799019
31 July 1998 Plan Review "T" Boat
Administrative · Activities Europe · Activity 795533
23 January 1998 Deficiency Check
Physical examination · Activities Europe · Activity 779035
18 December 1997 Deficiency Check
Physical examination · Activities Europe · Activity 1116585
20 November 1997 Re-Inspection
Physical examination · Activities Europe · Activity 1404468
30 July 1997 Administrative
Administrative · Activities Europe · Activity 1117252
17 June 1997 Administrative
Administrative · Activities Europe · Activity 775614
14 April 1997 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1099962
7 February 1997 Type not recorded
No type recorded · Activities Europe · Activity 186796
2 February 1997 Plan Review "T" Boat
Administrative · Activities Europe · Activity 1102715
9 December 1996 Plan Review "T" Boat
Administrative · Activities Europe · Activity 1091647
7 October 1996 COI Inspection · Inclining Experiment · Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1359324
8 May 1995 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 866541
28 April 1995 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1174431
7 April 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1151430
12 February 1995 Drydock Extension
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 840946
30 November 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 863789
25 September 1994 Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1363127
8 June 1994 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 141185
20 May 1994 Re-Inspection · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1374072
19 October 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 44018
19 October 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 69351
30 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 92386
23 April 1993 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1139809
8 April 1993 COI Inspection · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 837656
15 October 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 956147
5 April 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 948548
23 July 1991 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1249314
23 May 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1254007
24 April 1991 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 932258
17 January 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 925997
24 April 1990 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 920040
17 November 1989 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 926890
27 September 1989 Hull Examination · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034136
24 April 1989 COI Inspection · Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1210469
12 August 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1040726
22 June 1988 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1040717
15 April 1988 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1041332
23 December 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1012006
21 November 1987 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1335146
29 April 1987 COI Inspection · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1325645
18 June 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 996885
8 June 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1300163
27 May 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1297720
16 January 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1309134
11 November 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301521
17 May 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 982865

Deficiency record · 217

Fire Fighting › Fire Main
Issued 21 October 2002 Resolved
Provide U/T readings on entire exterior fire main piping, all fire main piping must meet ABS rules for acceptance or renew to as built approved plans. Due 17 NOV 02. ** This requirement was extended by MIO Europe due to well testing. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 5 December 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 October 2002 Resolved
Service all fixed, semi-portable CO2 extinguishers, CO2 local & remote release stations IAW 46 CFR 107.235. LEGACY COMPONENT DESC: Quantity of CO2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 5 December 2002
Resolution: Vessel is now weighing their own cylinders.
Construction/Loadline › Penetrations › Pipe Flange
Issued 21 October 2002 Resolved
Provide / renew port and starboard lower cooling water supply valves - sea valves 12" - To meet specifications on approved construction plans. Due 17 NOV. This item was extended until 5 DEC by MIO Europe. LEGACY COMPONENT DESC: Valve Flange
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Accommodation/Occupational Safety
Issued 21 October 2002 Resolved
Make proper repairs to "holed" bulkhead between mud pump room and mud pit room. This is a classifed space, Class 1 Div 1 and must maintain negative pressure inside or upgrade the mud pump room to Class 1 Div 1 also.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 5 December 2002
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 21 October 2002 Resolved
New quarters addition not to be commissioned for use until proof of approvals, all lifesaving items reviewed (new davit launched raft under helo deck), fire fighting, electrical, sanitary connections are connected, inspected and accepted by attending marine inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Operations/Management
Issued 21 October 2002 Resolved
Prepare rig for annual USCG inspection IAW 46 CFR 107.231.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2002
Resolved 5 December 2002
Lifesaving › Lifeboat
Issued 21 October 2002 Resolved
All weight tests due on life boats, davits, davit launched rafts must be witnessed by USCG inspector NLT JAN 2003.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 December 2002
Construction/Loadline › Penetrations
Issued 21 October 2002 Resolved
Crop and renew ballast piping where doubler plates are welded on port side inside column pump room. Must be competed ASAP. LEGACY COMPONENT DESC: Pipe Flange
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2002
Resolved 5 December 2002
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 October 2002 Resolved
Prove operation of port & starboard OWS's, ALL oily waste must be retained onboard until shoreside disposal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Construction/Loadline › Structures › Door
Issued 21 October 2002 Resolved
Repair/adjust all weathertight & watertight doors and hatches to provide proper closure (interior & exterior).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 October 2002 Resolved
Repair leaking S/W cooling line to #3 generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Construction/Loadline › Structures › Door
Issued 21 October 2002 Resolved
Repair/renew all doors and door closures, adjust doors to close properly, doors include galley, mess room, changing rooms, and accomodations passageways.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Lifesaving › Lifeboat › Markings
Issued 21 October 2002 Resolved
Renew reflective tape as necessary and where missing on all three lifeboats, and on all lifejackets as necessary.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Lifesaving › Lifeboat › Hull
Issued 21 October 2002 Resolved
Make permanent professional repairs to cracked bow area starboard side of #3 lifeboat hull and deck prior to returning boat to service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Lifesaving › Lifeboat › Propeller
Issued 21 October 2002 Resolved
Operate all three lifeboats in the water IAW 46 CFR 109.213(d).
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Lifesaving › Inflatable Liferafts › Floor
Issued 21 October 2002 Resolved
Operate/deploy one davit launched life raft for training IAW 46 CFR 109.213(g)(5).
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 21 October 2002 Resolved
Properly post/mark helicopter access routes with tail rotor warning signs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Accommodation/Occupational Safety › Ventilation › General
Issued 21 October 2002 Resolved
Make permanent repairs to damaged mushroom closures IVO aft end of helicopter deck. LEGACY COMPONENT DESC: Exterior closures
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 October 2002 Resolved
Renew/adjust/repair doors and closures to both doors for mud pit room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 January 2003
Resolved 19 February 2016
Resolution: Vessel reflagged Deficiencies no longer apply
Documentation
Issued 29 November 2001 Resolved
Submit copy of written ABS and diver's report, including video of SEILOD.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Documentation › Certificates/Documents
Issued 29 November 2001 Resolved
Provide ABS crane test reports on all three cranes.
Condition: Unknown
Due 11 February 2002
Resolved 11 February 2002
Resolution: OIM states that ABS will forward. OIM faxed Class Document with endorsement for 2001.
Fire Fighting
Issued 29 November 2001 Resolved
Upon reciept of CO2 cylinders within hydrostatic test date, as per OIM ltr dtd 2 AUG 01, OIM to fax statement of fact, with OIM license number and signature.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 29 November 2001 Resolved
Provide gaugings and structrual analysis for #3 lifeboat davit or make proper repairs to wasted area's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 November 2002
Resolved 11 February 2002
Resolution: Area to be inspected at next USCG inspection. Deck plating was renewed.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 November 2001 Resolved
Provide safety cables on all hazardous location lights.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 February 2002
Resolved 11 February 2002
Resolution: Cleared by fax. Verify at next USCG inspection.
Construction/Loadline
Issued 29 November 2001 Resolved
Renew cooling water supply valve on stbd lower seachest - OIM to fax signedstatement of fact with license number.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2001
Resolved 6 December 2001
Resolution: Valve renewed on 2 SEP 2001, OIM Bennie Smith faxed status and statement that valve had been renewed. Verify at next USCG inspection.
Documentation
Issued 29 November 2001 Resolved
Provide final ALGOA NDT testing report on K-Brace repairs.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Lifesaving
Issued 29 November 2001 Resolved
Operate #3 Lifeboat in the water, including water spray and fax OIM's statement of fact with OIM's license number and signature.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Fire Fighting
Issued 29 November 2001 Resolved
Renew flex loop hose on paintlocker CO2 cylinder.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Lifesaving
Issued 29 November 2001 Resolved
Provide SART in #3 lifeboat IAW 79/89 MODU code, 91 amendments 10.7.2.
Condition: Unknown
Due 30 November 2001
Resolved 30 November 2001
Lifesaving
Issued 2 October 2000 Resolved
Provide insulated gloves for firemans outfit. Gloves to be in compliance with NFPA 1971
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Electrical
Issued 2 October 2000 Resolved
Electric box adrift at forward end of life boat #3, cable penetrations not properly secured. Secure box and make up proper cable penetrations.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Construction/Loadline
Issued 2 October 2000 Resolved
Crop and renew all wasted water tight door gasket retaining channels.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Navigation
Issued 2 October 2000 Resolved
Properly time obstruction lights to required international standard.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
Renew all broken life boat water curtain spray nozzles.
Condition: Unknown
Due 10 November 2000
Resolved 18 February 2001
Fire Fighting
Issued 2 October 2000 Resolved
Provide copy of the foam analysis report.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Engineering
Issued 2 October 2000 Resolved
Properly bracket the JP 5 fuel lines at the forward corner of the accommodation space.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Fire Fighting
Issued 2 October 2000 Resolved
Restore the class A boundary in the storeroom across from the mess room entrance.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Construction/Loadline
Issued 2 October 2000 Resolved
Renew the waste knife edge for the vent closure on the bulkhead by life boat #1.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Construction/Loadline
Issued 2 October 2000 Resolved
Make proper electric cable penetration through bulkhead near fire station #7.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Fire Fighting
Issued 2 October 2000 Resolved
Black iron pipe used in the paint locker CO2 system in way of flex loop. Renew pipe with proper non corrosive pipe.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
Renew dog missing from forward window and operator's window in life boat number three.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
Life boat windows opaque. Renew all opaque glass to restore as original.
Condition: Unknown
Due 10 November 2000
Resolved 18 February 2001
Lifesaving
Issued 2 October 2000 Resolved
Renew/restore clouded compass for number 1 life boat.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Fire Fighting
Issued 2 October 2000 Resolved
Free up seized vent closure for the battery room vent duct.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
Provide two properly mounted davit launched life rafts with valid annual servicing, replacement for expired rafts, for a total of 4 davit launched life rafts on board.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
Gasoline stored in 5 gallon plastic containers. Provide proper storage container for gasoline.
Condition: Unknown
Due 10 November 2000
Resolved 18 February 2001
Engineering
Issued 2 October 2000 Resolved
Tachometer missing from number 1 diesel generator. Renew tachometer as original.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
Conduct crew training on the launching procedure for davit launched life raft using demonstration raft IAW 46CFR 109.213.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
General alarm light not operating in the shale shaker room and mud pump room, repair and prove proper operation. Repair and prove proper operationof the general alarm bell forward main deck starboard.
Condition: Unknown
Due 29 December 2000
Resolved 29 December 2000
Lifesaving
Issued 2 October 2000 Resolved
Renew wasted fill opening necks on the life boat water tanks.
Condition: Unknown
Due 10 November 2000
Resolved 18 February 2001
Engineering
Issued 2 October 2000 Resolved
Renew wasted sea water line in the engine room over head.
Condition: Unknown
Due 10 November 2000
Resolved 18 February 2001
Construction/Loadline
Issued 24 October 1999 Resolved
Provide a copy of the SEILODD video to the OCMI.
Condition: Unknown
Due 24 October 1999
Resolved 24 October 1999
Engineering
Issued 24 October 1999 Resolved
Crop and renew holed seawater cooling piping located between #2 & #3 generators.
Condition: Unknown
Due 24 October 1999
Resolved 24 October 1999
Fire Fighting
Issued 24 October 1999 Resolved
Provide serviced fire extinguishers for Rig's spares. 16 extinguishers aredue for hydro test.
Condition: Unknown
Due 28 October 1999
Resolved 28 October 1999
Construction/Loadline
Issued 24 October 1999 Resolved
Provide a copy of the eddy current weld test results to the OCMI.
Condition: Unknown
Due 24 October 1999
Resolved 24 October 1999
Construction/Loadline
Issued 24 October 1999 Resolved
Replace sub-pump in the starboard pump room.
Condition: Unknown
Due 24 October 1999
Resolved 24 October 1999
Lifesaving
Issued 24 October 1999 Resolved
Provide liferafts with current servicing dates for stations #1 & #2.
Condition: Unknown
Due 24 October 1999
Resolved 24 October 1999
Construction/Loadline
Issued 24 October 1999 Resolved
Renew wasted deck plating on main deck outboard of the emergency generator room.
Condition: Unknown
Due 24 October 1999
Resolved 24 October 1999
Documentation
Issued 20 November 1997 Resolved
Provide copy of JIM CUNNINGHAM Muster List and Emergency Instructions.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Electrical
Issued 20 November 1997 Resolved
Renew mud pit level indicator explosion proof boxes--corroded.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Fire Fighting
Issued 20 November 1997 Resolved
Replace two 1 1/2" fire hoses.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Fire Fighting
Issued 20 November 1997 Resolved
Refill empty fixed fire system CO2 bottle.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Electrical
Issued 20 November 1997 Resolved
Renew drill floor self-closing explosion proof receptacles.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Documentation
Issued 20 November 1997 Resolved
Provide proper documentation of fully compliant chemical testing program for the following def.: Manual containing procedures for testing for "Serious Marine Incident" and for "Reasonable Cause". Procedures on specimen collection site requirements. Provide (EAP) for crew & supervisors
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Documentation
Issued 20 November 1997 Resolved
Update EMERGENCY TRAINING & DRILLS as per 46CFR109.213.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Lifesaving
Issued 20 November 1997 Resolved
Provide annual liferaft servicing for liferafts with lot numbers 287 & 289.
Condition: Unknown
Due 20 November 1997
Resolved 20 November 1997
Lifesaving
Issued 20 November 1997 Resolved
Mark all lifejackets and lifebuoys storage locations as per 46CFR108.649.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Electrical
Issued 20 November 1997 Resolved
Remove or renew the drill floor 208V receptales.
Condition: Unknown
Due 1 December 1997
Resolved 1 December 1997
Fire Fighting
Issued 7 October 1996 Resolved
Provide holding brackets for 15 lb CO2 bottles. This item to be witnessed by ELF with a leter/check sheet to MIDET Singapore to clear.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Lifesaving
Issued 7 October 1996 Resolved
Repair H2S and LEL monitor for vessel. This item to be witnessed by ELF with a letter/check sheet to MIDET Singapore to clear.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Fire Fighting
Issued 7 October 1996 Resolved
Provide approved plans for AFFF system for mud pit room and CO2 system for SCR room. System to remain deactivated until plans are approved. This item to be witnessed by ELF with a leter/check sheet to MIDET Singapore to clear.
Condition: Unknown
Due 7 October 1996
Resolved 7 October 1996
Lifesaving
Issued 8 May 1995 Resolved
CONDUCT WEIGHT TEST OF LIFEBOAT #3 UPON ARRIVE ON LOCATION OR NO LATER THAN08JUNE95 IAW 46CFR 107.239_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 June 1995
Resolved 2 June 1995
Fire Fighting
Issued 8 May 1995 Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO RIG DRILLING OPERATIONS OR NO LATER THAN 08 JUNE 1995 IAW 46CFR 97.15-35_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 June 1995
Resolved 2 June 1995
Documentation
Issued 30 November 1994 Resolved
PROVIDE PHOTOGRAMMETIC RESULTS FROM 29NOV94 HULL MONITORING INSPECTION TO MIO EAST ASIA FOR REVIEW.
Condition: Unknown
Due 30 November 1994
Resolved 30 November 1994
Fire Fighting
Issued 25 September 1994 Resolved
REPAIR BROKEN HANDLE ON HELO DECK BV SEMI PORTABLE EXTINGUISHER.
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Lifesaving
Issued 25 September 1994 Resolved
PROPERLY LABEL LIFERAFT STATIONS NEXT TO THE LIFE RAFTS WITH RAFT STATION NUMBER OF PERSONS CAPACITY.
Condition: Unknown
Due 5 October 1994
Resolved 5 October 1994
Electrical
Issued 25 September 1994 Resolved
PROPERLY SECURE EXPOSED DEAD END CABLES HANGING LOOSE IN THE SHALE SHAKER ROOM.
Condition: Unknown
Due 1 December 1994
Resolved 5 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
FREE SIEZED BOLTS AND RENEW MISSING BOLTS FOR HELO DECK FOAM MONITOR.
Condition: Unknown
Due 1 December 1994
Resolved 5 October 1994
Engineering
Issued 25 September 1994 Resolved
IDENTIFY ALL FUEL TANK VENTS AND REPAIR OR RENEW ALL FUEL TANK VENT FLAME SCREENS DISREPAIR.
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Electrical
Issued 25 September 1994 Resolved
EMERGENCY GENERATOR ROOM DECK PUDDLED WITH OIL, SWITCHBOARD INSULATING MAT OIL SOAKED. CLEAN EMERGENCY GENERATOR ROOM AND RENEW INSULATING MAT.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
FREE UP AIR SUPPLY AND EXHAUST VENT CLOSERS FOR EMERGENCY GENERATOR ROOM. VENT LOUVERS ARE STIFF IN DISREPAIR AND FAIL TO PROPERLY CLOSE.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
PROPERLY SECURE LOOSE FIRE ALARM PULL BOX LOCATED PORTSIDE OF THE MOTOR ROOM.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
FREE UP AND PROVE PROPER OPERATION OF PAINT LOCKER VENTILATION CLOSER LOUVERS.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
RENEW MISSING TUBING CLAMPS FOR PAINT LOCKER CO2 PULL CABLE TUBING.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 25 September 1994 Resolved
NUMEROUS CANS OF PAINT AND THINNER OPENED AND UNCOVERED IN THE PAINT LOCKER. TIDY UP PAINT LOCKER AND PROPERLY STORE PAINT AND THINNER.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
ACCOMMODATION SPACE FAN ROOM IN DISREPAIR DECK DRAIN PLUGGED, SPACE AWASH IN CONDENSATE WATER. CLEAR DRAIN, REMOVE WATER AND PROPERLY INSULATE PIPING TO ELIMINATE ACCUMULATION OF WATER.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
RENEW MISSING PIPE CLAMPS FOR FIRE MAIN PIPING AT STATION NO. E8 AND NO. E12.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
RENEW BROKEN AND MISSING CHANGE ROOM FLOOR TILES.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Fire Fighting
Issued 25 September 1994 Resolved
RESTORE HELICOPTER WAITING ROOM BULKHEAD TO CLASS "A-60" AND PROPERLY SECURE CABLE RUNS.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Construction/Loadline
Issued 25 September 1994 Resolved
CLEAN ENTIRE PORT AND STARBOARD PONTOONS - TOP, BOTTOM, ENDS, AMD SIDES. MAKE AVAILABLE FOR GAUGING AND VIDEO EXAM. GAUGE AND PROVIDE A WRITTEN REPORT IDENTIFYING ALL AREAS OF PITTING, SIZE AND DEPTH OF PITS, WASTED WELDS, WASHED WELDS AND PLATE DETERIORATION.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
CHANGE ROOM DOOR FALLEN OFF HINGES. RENEW OR REPAIR CHANGE ROOM DOOR.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 25 September 1994 Resolved
QUICK RELEASE RING BOUYS IMPROPERLY INSTALLED AND IN DISREPAIR. REPAIR ANDPROPERLY MOUNT RING BOUYS.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Construction/Loadline
Issued 25 September 1994 Resolved
MANHOLE ACCESSES IN THE #1 AND #3 STARBOARD COLUMNS AT END OF BOX GIRDERS NOT PROPERLY SECURED, NUMEROUS SECURING NUTS AND STUDS MISSING, COVERS LOOSE. REPAIR AND PROPERLY SECURE MANHOLE COVERS.
Condition: Unknown
Due 3 October 1994
Resolved 3 October 1994
Lifesaving
Issued 25 September 1994 Resolved
PORT AND STARBOARD LIFELINES ON #2 MOTOR LIFEBOAT BROKEN. RENEW OR REPAIR LIFELINES.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
GUARD RAIL AT #2 LIFEBOAT MISSING MOUNTS WASTED. RENEW OR REPAIR RAIL AS ORIGINAL.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
RENEW OR REPAIR DOOR CLOSERS AND OR DOOR LATCHES BROKEN AND OR MISSING FOR THE FOLLOWING DOORS: HELO DECK WAITING ROOM, ROUSTABOUTS ROOM #111P, MESS ROOM #1 DOOR, RADIO ROOM, PILOT HOUSE TO ACCOMMODATION.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Electrical
Issued 25 September 1994 Resolved
PROPERLY SECURE RADIO ROOM EMERGENCY LIGHTING FIXTURE.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 25 September 1994 Resolved
PROPERLY MARK BATTERY ROOMS TO INDICATE THAT NAKED LIGHTS OR SMOKING IN THIS ROOM OR AREA IS NOT ALLOWED.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
REMOVE HOLD BACK DEVICE MOUNTED ON MAIN DECK ACCOMMODATION STAIRWAY DOOR.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Engineering
Issued 25 September 1994 Resolved
RENEW FLAME SCREEN AND LOUVERS, MISSING FROM EMERGENCY GENERATOR FUEL OIL TANK.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
DISPOSE OF ALL CHIPPED AND CRACKED CHINA WARE IN USE IN MESS.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
MAKE ALL REQUIRED PORTABLE FIRE EXTINGUISHERS HIDDEN IN BOXES VISIBLE AND READILY AVAILABLE IN ACCORDANCE WITH 46CFR108.493(b).
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 25 September 1994 Resolved
PROPERLY LABEL GENERAL ALARM BELL LOCATED OVER EMERGENCY GENERATOR ROOM DOOR, GENERAL ALARM - WHEN BELL RINGS GO TO YOUR STATION.
Condition: Unknown
Due 4 October 1994
Resolved 4 October 1994
Lifesaving
Issued 25 September 1994 Resolved
DAVIT LAUNCHED LIFERAFTS NOT PROPERLY INSTALLED IN ACCORDANCE WITH MANUFATURES INSTRUCTIONS: IMPROPER RELEASE HOOKS, LOCKING HOOK ASSEMBLY MISSING ETC. PROPERLY INSTALL LIFERAFTS FOR FLOAT FREE RELEASE.
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Construction/Loadline
Issued 25 September 1994 Resolved
TWO INCH DRAFT INDICATING SEA VALVES LOCATED IN THE PORT AND STARBOARD PROPULSION ROOMS ARE NOT READILY ACCESSIBLE. BRING SEA VALVES INTO COMPLIANCE WITH 46CFR56.50-95
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
PROVIDE COMPLETE BUT SIMPLE OPERATING INSTRUCTIONS FOR FIXED CO2 SYSTEMS NEAR THE CONTROLS.
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
FIRE DOOR MAIN DECK PASSAGEWAY TO MACHINERY SPACE PASSAGEWAY DOES NOT CLOSEPROPERLY. RENEW OR REPAIR FIRE DOOR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
DESIGNATED ROUTE FROM REMOTE PULL STATION TO SECONDARY CONTROLS FOR DISCHARGE OF MOTOR ROOM CO2 HAS LOCKED DOOR. MAKE DESIGNATED ROUTE TO SECONDARY MEANS TO DISCHARGE MOTOR ROOM CO2 ACCESSIBLE AND POST REQUIRED INSTRUCTIONS.
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Lifesaving
Issued 25 September 1994 Resolved
MARK EACH ACCESS TO THE HELICOPTER LANDING AREA "BEWARE OF TAIL ROTOR" IAW 46CFR108.653.
Condition: Unknown
Due 1 November 1994
Resolved 5 October 1994
Lifesaving
Issued 25 September 1994 Resolved
ADJACENT TO THE FUEL HOSE STORGE FOR HELICOPTER FUELING STATION MARK "WARNING - HELICOPTER FUELING STATION - KEEP LIGHTS AND FIRE AWAY"
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
MAIN BANK CO2 CYLINDER PILOT BOTTLE FLEX LOOP IS IN TENSION. RENEW EXISTINGFLEX LOOP WITH FLEX LOOP OF PROPER LENGTH.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Lifesaving
Issued 25 September 1994 Resolved
WARNING SIGN FOR GENERAL ALARM LIGHT IN EMERGENCY GENERATOR ROOM OBSCURED. PROPERLY IDENTIFY GENERAL ALARM LIGHT.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Lifesaving
Issued 25 September 1994 Resolved
PROPERLY IDENTIFY STORAGE TANK FOR HELICOPTER FUEL "DANGER - FLAMMABLE LIQUID" IAW 46CFR108.653.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Engineering
Issued 25 September 1994 Resolved
JET "A" FUEL PIPING SECURING BRACKETS WASTED AND MISSING LEAVING FUEL PIPING UNSUPPORTED OVER APPROXIMATELY A 60 FOOT SPAN. RENEW MISSING AND WASTED CLAMPS TO PROPERLY SUPPORT FUEL PIPING.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Electrical
Issued 25 September 1994 Resolved
TROUBLE SHOOT EMERGENCY GENERATOR DETERMINE CAUSE OF OIL LEAKS MAKE PERMANENT REPAIR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
PAINT LOCKER FIRE DOOR HOLED, MISSING DOOR NOB AND LATCH. RENEW LATCH AND NOB FOR PAINT LOCKER DOOR AND PROVE PROPER OPERATION.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Lifesaving
Issued 25 September 1994 Resolved
COLUMN LADDER CAGES MISSING, DAMAGED AND IN DISREPAIR. FIT EACH EXTERIOR VERTICLE COLUMN LADDER WITH A CAGE MEETING ANSI STANDARD 14.3 (1974).
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Lifesaving
Issued 25 September 1994 Resolved
WATERLIGHTS FOR LIFE PRESERVERS LOCATED IN THE WAREHOUSE PAST EXPIRATION DATE. RENEW ALL EXPIRED WATERLIGHTS WITH SOLAS APPROVED WATERLIGHTS.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
Galley reach in refer door gaskets hard, not making proper seal. Renew allrefer door gaskets in disrepair.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Documentation
Issued 25 September 1994 Resolved
SUBMIT DATA FOR TOP DRIVE UNIT TO ABS AND U.S. COAST GUARD AS REQUIRED FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Construction/Loadline
Issued 25 September 1994 Resolved
Watertight and weathertight doors and dogs not properly adjusted. Properlyadjust doors, dogs, and prove proper operation.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Lifesaving
Issued 25 September 1994 Resolved
Provide all lifeboats, rescue boat, and ring life bouys with _x001C_ retro-reflective material in accordance with Solas reg. 30.7 and resolutionA.658[16]. See USCG NVIC 1-87 for guidance.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
Accommodation spaces in disrepair. Room 106P wash basin cracked, room 110S wash basin holed. Restore accommodation spaces to an acceptable standard.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Electrical
Issued 25 September 1994 Resolved
Prov. refer electric control center drip proof box in disrepair. Box jury rigged, hole drilled in top of box with electric cable strung through. Make permanent repair to control box and bring into compliance with 46CFR111.40-5.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Electrical
Issued 25 September 1994 Resolved
NUMEROUS ELECTRIC PANEL BOARDS MISSING DIRECTORIES, NEARLY ALL EXISTING DIRECTORIES ARE IMPROPER. PROVIDE DIRECTORIES FOR ALL PANEL BOARDS AND BRING ALL DIRECTORIES INTO COMPLIANCE WITH 46CFR111.40-11.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Electrical
Issued 25 September 1994 Resolved
Numerous plastic ties in use and numerous cables not properly secured. Properly secure all cable runs in accordance with 46CFR110.10-1 AND IEEE45.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Lifesaving
Issued 25 September 1994 Resolved
PROPERLY LABEL FOAM TANK ROOM AND ALL OTHER SPACES AND ALL OTHER SPACES CONTAINING FIXED FIRE EXTINGUISHING SYSTEM CONTROLS, IN ACCORDANCE WITH 46CFR108.631.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Fire Fighting
Issued 25 September 1994 Resolved
VENT CLOSURE FOR MUD PUMP ROOM IN DISREPAIR. LOUVERS NOT CLOSING PROPERLY.MAKE PERMANENT REPAIR AND PROVE PROPER OPERATION OF VENT CLOSURES.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
RENEW BROKEN, DAMAGED, MISSING TILE IN GALLEY.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Accommodation/Occupational Safety
Issued 25 September 1994 Resolved
DRYSTORES INFESTED WITH INSECTS. EXTERMINATE VERMIN AND ESTABLISH A CONTROL PROGRAM TO MAINTAIN SPACE VERMIN FREE.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Lifesaving
Issued 25 September 1994 Resolved
NUMEROUS ACCOMMODATION SPACE LIFE PRESERVERS PADLOCKED IN LOCKERS. MAKE ALL LIFE PRESERVERS READILY AVAILABLE.
Condition: Unknown
Due 11 November 1994
Resolved 5 October 1994
Construction/Loadline
Issued 25 September 1994 Resolved
MAKE PERMANENT REPAIR TO WASTED, PITTED AND HOLED AREAS IN THE PORT AND STARBOARD #11 SEA WATER BALLAST TANKS, INWAY OF KORT NOZZLE ATTACHMENT TO HULL. PERMANENT REPAIR TO BE MADE IN LIEU OF EXISTING TEMPORARY CEMENT BOXWELDED PLATE PATCH.
Condition: Unknown
Due 25 September 1994
Resolved 25 September 1994
Engineering
Issued 20 May 1994 Resolved
Repair or replace the oliy water separator and prove satisfactory operationfor a Coast Guard Inspector which will demonstrate compliance with the IOPPCertificate.
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994
Lifesaving
Issued 20 May 1994 Resolved
Provide weak links for all four life rafts and rig the hydrostatic release and weak link to allow proper stowage for the required davit launch and float free arrangement as per the IMO code.
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994
Fire Fighting
Issued 20 May 1994 Resolved
Submit revised drawings for review and approval for the fixed CO2 systems for the machinery space and the mud pump room, which reflect the modifications as presently installed.
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994
Electrical
Issued 5 April 1992 Resolved
Repair warning light located on top of the starborad side aft crane A- Frame.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Construction/Loadline
Issued 5 April 1992 Resolved
Provide new bilge high level alarm float switch for the port side pump room.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Electrical
Issued 5 April 1992 Resolved
Have Exlog personnel, properly install cable runs on drill floor and to theExlog trailer.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Electrical
Issued 5 April 1992 Resolved
Provide new control module for number two generator. Upon re-installation conduct reverse power trip, overspeed trip, loww lube oil pressure alarm and trip and high jacket water temperature alarm. Notify [name withheld] of the test results.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Lifesaving
Issued 5 April 1992 Resolved
Replace all expired smoke, hand held and parachute flares for the_x001C_ lifeboats.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Fire Fighting
Issued 5 April 1992 Resolved
Remove the 10 portable fire extinguishers and 4 fixed CO2 bottles which arepresently overdue for hydrostatic test, to a DOT approved facility for testand refill. Insure that the minimum number, type, and size extinguishers are available to meet the requirements of the regulations.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Construction/Loadline
Issued 5 April 1992 Resolved
Provide new digital display board for the Sarex unit.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Fire Fighting
Issued 5 April 1992 Resolved
Provide international shore connection.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Lifesaving
Issued 5 April 1992 Resolved
Remove air bottles from all lifeboats and have them hydrostatically tested at a DOT approved facility. Removal must be accomplished one boat at a time or provide suitable replacement bottles during the period the bottles are ashore for testing and refill.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Fire Fighting
Issued 5 April 1992 Resolved
Provide new flow sensor for the upper level accommodations sprinkler system.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Electrical
Issued 5 April 1992 Resolved
Provide new blower motor for the corner obstruction main lights.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Electrical
Issued 5 April 1992 Resolved
Provide new bulbs for the port bow and starboard aft corner emergency obstruction lights.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Fire Fighting
Issued 5 April 1992 Resolved
Provide rubber gloves for both firemens outfits.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Lifesaving
Issued 5 April 1992 Resolved
Replace the damaged and broken paddles on the #3 lifeboat.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Electrical
Issued 5 April 1992 Resolved
Provide new jacket water temperature sensor for the emergency generator_x001C_ diesel engine.
Condition: Unknown
Due 5 April 1992
Resolved 5 April 1992
Construction/Loadline
Issued 27 September 1989 Resolved
PROVIDE COPY OF UNDERWATER INSPECTION REPORT INCLUDING COPY OF VIDEO TAPE AND COPY OF N.D.T. INSPECTION REPORT.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989 Resolved
PLACE ONBOARD ONE ADDITIONAL 25 MAN FLOATFREE/DAVIT LAUNCHED LIFERAFT PRIOR TO MANNING RIG ABOVE 75 TOTAL PERSONS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Unknown
Issued 27 September 1989 Resolved
REVISE AND RESUBMIT FOR APPROVAL THE DRYDOCKING PLAN FOR 1991. THE REVISEDPLAN SHOULD INCLUDE NON-DESTRUCTIVE TESTING/INSPECTION OF #1P, 2P, AND 2S COLUMN-TO-PONTOON CONNECTIONS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Accommodation/Occupational Safety
Issued 27 September 1989 Resolved
PROVIDE EVIDENCE OF USCG MARINE SAFETY CENTER APPROVAL OF "AS BUILT" PLANS FOR STRUCTURAL FIRE PROTECTION MODIFICATIONS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Accommodation/Occupational Safety
Issued 27 September 1989 Resolved
PROVIDE EVIDENCE OF USCG MARINE SAFETY CENTER APPROVAL OF PLANS FOR FIRE DETECTION INSTALLATION.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 24 April 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Fire Fighting
Issued 24 April 1989 Resolved
SERVICE FIXED AND PORTABLE FIRE EXTINGUISHERS, PROVIDE EVIDENCE OF SATISFACTORY FOAM ANALYSIS FOR BOTH FOAM TANKS, AND RETURN AND INSTALL ONBOARD, 4 MISSING 100 LB CO2 BOTTLES FOR THE FIXED SYSTEM.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Lifesaving
Issued 24 April 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Unknown
Issued 24 April 1989 Resolved
INSTALL "DEADMAN" BACK PRESSURE SHUT-OFF NOZZLES AT FORKLIFT AND CRANE REFUELING STATIONS.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Unknown
Issued 24 April 1989 Resolved
REPAIR OR REPLACE LEAKING TOP VALVES FOR TENSIONER BOTTLES ID#'S PIT 76042 AND PIT 76054. MAKE BOTTLES AVAILABLE FOR INTERNAL INSPECTION, OR HYDRO- TEST AND RELIEF VALVES AVAILABLE FOR TESTING, IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 24 April 1989
Resolved 24 April 1989
Construction/Loadline
Issued 22 June 1988 Resolved
EFFECT PERMANENT REPAIR TO DAMAGED AREA AT FRAME 45 AT AFT END OF NO. 5 CHAIN TUNNEL.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Lifesaving
Issued 22 June 1988 Resolved
CONDUCT WEIGHT TEST OF DAVIT LAUNCHED LIFERAFT DAVITS IN ACCORDANCE WITH 46 CFR 107.239(B). ITEMS OVERDUE FOR INSPECTION. ITEM MAY BE COMPLETED AT NEXT INSPECTION FOR CERTIFICATION.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Construction/Loadline
Issued 22 June 1988 Resolved
EFFECT PERMANENT REPAIRS TO FRACTURED AREA, PORT PONTOON AFT IN WAY OF NO. 11 BALLAST TANK.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Lifesaving
Issued 22 June 1988 Resolved
HYDROSTATICALLY TEST AIR BOTTLES FOR BREATHING SYSTEM IN LIFEBOATS.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Construction/Loadline
Issued 21 November 1987 Resolved
PROVIDE A COPY OF THE NDT REPORT AND YARD SPECIFICATIONS RELATING TO THE UNDERWATER HULL SURVEY CRITICAL JOINT EXAMINATION AND ALL OTHER YARD REPAIRITEMS.
Condition: Unknown
Due 21 November 1987
Resolved 21 November 1987
Lifesaving
Issued 21 November 1987 Resolved
CONDUCT FIRE AND BOAT DRILL AFTER FULL CREW IS ON BOARD BUT PRIOR TO ANY DRILLING OPERATIONS. RECORD COMMENTS AND RESULTS OF THE DRILLS IN THE DAILY LOG AND FORWARD COPY TO THE [name withheld].
Condition: Unknown
Due 21 November 1987
Resolved 21 November 1987
Deck/Cargo
Issued 21 November 1987 Resolved
SUBMIT DRAWING AND MATERIAL SPECIFICATION TO THE COAST GUARD MARINE SAFETY CENTER FOR REVIEW AND APPROVAL OF THE WELL OIL FLOW PIPING PRESENTLY BEING INSTALLED ON THE AFT DECK AREA. SYSTEM MUST BE HYDROSTATICLY TESTED AT ONEAND A HALF TIMES THE MAWP PRESSURE TO BE USED.
Condition: Unknown
Due 21 November 1987
Resolved 21 November 1987
Unknown
Issued 29 April 1987 Resolved
REPAIR OR REPLACE THE DEFECTIVE CIRCUIT BREAKER ON THE NUMBER THREE SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Construction/Loadline
Issued 29 April 1987 Resolved
REPLACE THE DETERIORATED PORT WEATHER TIGHT DOOR TO THE PILOT HOUSE.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Engineering
Issued 29 April 1987 Resolved
DEMONSTRATE THE POSITIONER THRUSTERS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
CONDUCT A FIRE AND BOAT DRILL AND RECORD THE RESULTS IN THE BRIDGE LOG.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
CONDUCT A WEIGHT TEST OF THE NUMBER 1,2,& 3 SURVIVAL CAPSULES
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
REPLACE ALL OF THE CONDENSED MILK IN THE NUMBER 1,2, & 3 SURVIVAL CAPSULES.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
REPLACE THE PROVISIONS IN THE NUMBER 1,2, & 3 SURVIVAL CAPSULES.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
RENEW THE DAVIT CABLES FOR THE NUMBER 1,2, & 3 SURVIVAL CAPSULE DAVITS
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
REPLACE THE OUTDATED BATTERIES FOR THE NUMBER 1 & 2 SURVIVAL CAPSULE EPIRB(S).
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
CONDUCT A WEIGHT TEST OF THE INFLATABLE LIFERAFT DAVITS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Lifesaving
Issued 29 April 1987 Resolved
REPLACE THE OUT OF DATE SMOKE SIGNALS FOR THE BRIDGE.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Unknown
Issued 29 April 1987 Resolved
REPLACE THE OUT OF DATE BATTERY IN THE BRIDGE EPIRB.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Fire Fighting
Issued 29 April 1987 Resolved
SERVICE THE FIXED CARBON DIOXIDE SYSTEM.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Fire Fighting
Issued 29 April 1987 Resolved
HAVE A FOAM SAMPLE SUBMITTED FOR ANALYSIS. PROVIDE A COPY OF THE RESULTS TO THE [name withheld], HAWAII
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987
Unknown
Issued 27 May 1986 Resolved
REPLACE OR REPAIR THE FIRE PUMP PRESSURE GAUGE FOR THE FIRE PUMP LOCATED IN THE MUD PUMP ROOM.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
RECHARGE FIRE EXTINGUISHER FOR LIFEBOAT NUMBER 3.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
PROVIDE FLASHLIGHT FOR LIFEBOAT NUMBER 2.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
REMOVE PADLOCK HASPS ON ALL DOORS THAT SERVE AS PRIMARY ESCAPE ROUTES.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
RENEW ALL EXPIRED WATER FOR LIFEBOAT NUMBER 1 AND 2.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
REPAIR SPRINKLER SUCTION VALVE ON LIFEBOAT NUMBER 3.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
RENEW RED PARACHUTE FLARES FOR LIFEBOAT NUMBER 3.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
PROVIDE A CERTIFICATE OF DOCUMENTATION FOR THE VESSEL WITH A CURRENT RENEWAL DECAL.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
PROVIDE AN INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE FOR THE VESSEL, OR APPLY IN WRITING TO MSO HONOLULU FOR A DUPLICATE. IOPP CERTIFICATE ENDORSEMENT FOR ANNUAL SURVEY CONDUCTED 27 MAY 1986 PENDS.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
PROVIDE PERSONAL FLOATATION LIGHTS FOR ALL EXPOSURE SUITS.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
RENEW ALL BATTERIES FOR LIFE PRESERVER PERSONAL FLOATATION LIGHTS OF THE BATTERY TYPE.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
HYDROSTATICALLY TEST ALL PORTABLE CO2 FIRE EXTINGUISHERS THAT ARE 5 YEARS OR LONGER SINCE THEIR LAST HYDRO TEST.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
REPLACE THE ILLUMINATION LIGHT FOR LIFERAFT STATION NUMBER 3 AND 4 AND REPAIR THE LIGHT SWITCH.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
REMOVE OR PLUG PADLOCK HASPS ON THE LIFE PRESERVER STOWAGE LOCKER AT LIFEBOAT NUMBER 3.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
PROVIDE EXPLOSION PROOF 3 CELL FLASHLIGHTS FOR EACH FIREMANS OUTFIT (2).
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
RENEW DAVIT LAUNCHED LIFERAFT BRAKE RELEASE CABLES AT BOTH LIFERAFT LAUNCHING STATIONS.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
CONDUCT ANNUAL INSPECTION OF THE FIXED CO2 SYSTEMS FOR THE ENGINE ROOM/MUD PUMP ROOM, AND THE PAINT LOCKER PER 46 CFR 109.223.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
SUBMIT FOAM SAMPLES FOR ANALYSIS AND PROVIDE RESULTS AS WELL AS CERTIFICATION AS TO SUITABILITY AS A FIRE FIGHTING FOAM PER 46 CFR 107.235(B)(2)(III).
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 27 May 1986 Resolved
PROVIDE REMOTE RELEASING MECHANISMS FOR 2 RING LIFE BUOYS AS OUTLINED IN 46 CFR 108.515(D). ACCEPTABLE REMOTE LOCATIONS WOULD BE EITHER THE CONTROL ROOM OR RADIO ROOM.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 11 November 1985 Resolved
PROVIDE CG-2692 FOR THE FIRE AND RESULTING LOSS OF THE EMERGENCY GENERATOR.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985 Resolved
REPLACE THE EMERGENCY GENERATOR AND REPAIR ANY OTHER ASSOCIATED DAMAGE, THEN CONDUCT OPERATION TESTS OF THE SYSTEM.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985 Resolved
CONDUCT FOLLOWING OPERATIONAL TESTS ON BOTH BOILERS: A. FLAME FAILURE ALARM/TRIP; B. OPERATIONAL LIMIT CONTROLS; C. LOW WATER ALARM/TRIP; D. REMOTE EMERGENCY SHUTDOWN.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985 Resolved
PROVE PROPER OPERATION OF THE PORT FWD COLUMN KNIFE VALVE ESCAPE HATCH.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985 Resolved
CONDUCT WATER TIGHTNESS TEST ON REPAIR INSERT TO THE STBD AFT DIAGONAL AND PROVIDE RESULTS.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985 Resolved
PROVIDE REPAIR DETAILS, WELD PROCEDURE, AND NON-DESTRUCTIVE TESTING RESULTSFOR REPAIR INSERT TO THE STBD AFT DIAGONAL.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985 Resolved
SET AND SEAL ALL BOILER SAFETY VALVES (4). SAFETY VALVES SHALL RELIEVE AT NOT GREATER THAN 150 PSI UNLESS INFORMATION CAN BE PROVIDED THAT STEAM PIPING WAS DESIGNED AND TESTED FOR A HIGHER PRESSURE. (SEE BOILER EQUIPMENT LIST)
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Unknown
Issued 11 November 1985 Resolved
HYDROSTATICALLY TEST BOTH BOILERS (FIRE TUBE) TO 1.5 MAWP.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Fire Fighting
Issued 17 May 1985 Resolved
PROVIDE 2 UL OR FM APPROVED OXYGEN METERS FOR THE UNITS FIREMEN'S OUTFITS.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Electrical
Issued 17 May 1985 Resolved
LABEL THE HELO DECK REFUELING REMOTE STOPS.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Construction/Loadline
Issued 17 May 1985 Resolved
PROVE PROPER OPERATION OF THE PORT FORWARD COLUMN/PONTOON, ESCAPE HATCH.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Lifesaving
Issued 17 May 1985 Resolved
PROVIDE 12 ROCKET PROPELLED FLARES FOR THE NUMBER 2 LIFEBOAT.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Engineering
Issued 17 May 1985 Resolved
TWO AUXILIARY BOILERS ARE NOT TO BE PLACED IN SERVICE UNTIL SATISFACTORILY HYDRO TESTED. PROVIDE THIS OFFICE WITH A LETTER STATING YOUR INTENTIONS INTHIS REGARD.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Lifesaving
Issued 17 May 1985 Resolved
REPAIR LIMIT SWITCH ON THE NUMBER 2 LIFEBOAT DAVIT, PORT SIDE.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Electrical
Issued 17 May 1985 Resolved
REPAIR H2S VISUAL ALARMS, UPPER DECK AFT QUARTERS AND PORT AND STARBOARD PONTOONS.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Lifesaving
Issued 17 May 1985 Resolved
PROVIDE ONE ADDITIONAL SERVICE LINE FOR THE UNITS' LINE THROWING GUN, TOTALOF 4 REQUIRED.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985
Fire Fighting
Issued 17 May 1985 Resolved
RECHARGE THE BV SEMI-PORTABLE FIRE EXTINGUISHER IN THE ENGINE ROOM.
Condition: Unknown
Due 17 May 1985
Resolved 17 May 1985

Casualty record · 1

5 January 2002Routine · role: Involved in a Marine Casualty · activity 1480579
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.