Records from 1984 to 1990. Most recent: inspection, 23 August 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 41
23 August 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247830
11 June 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1219189
15 April 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915230
26 March 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933090
26 March 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1222712
4 January 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237140
4 January 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241991
10 October 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 976581
10 October 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1003813
27 September 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1001208
16 August 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1045089
26 June 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888871
6 June 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350476
16 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195776
10 May 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350591
25 August 1988
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038841
12 July 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1210485
31 May 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896836
23 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292476
16 March 1988
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301669
3 February 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017548
11 January 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318796
29 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319402
4 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011687
9 July 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017218
18 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007746
18 June 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315229
17 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027091
17 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311631
12 May 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027472
21 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334403
10 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316527
27 January 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317676
28 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320047
14 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991078
30 June 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294166
8 November 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1302345
18 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291255
5 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291118
6 June 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282295
20 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973118
Construction/Loadline
Issued 26 March 1990
Resolved
REPAIR OR REPLACE LEAKING SEA VALVE #23 PORT AND PNEUMATIC ACTUATOR.
Condition: Unknown
Due 26 March 1990
Resolved 26 March 1990
Accommodation/Occupational Safety
Issued 10 October 1989
Resolved
PRIOR TO FULL ACTIVATION OF THE SYSTEM, INSTALL RUPTURE DISCS ON ALL HP AIR RECEIVERS WHICH ARE NOT GREATER THAN 2400 LBS OR INSTALL RELIEF VALVES.NEW RUPTURE DISCS SHOULD BE SPOT CHECKED FOR PROPER OPERATION.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Lifesaving
Issued 16 May 1989
Resolved
RENEW LIFEBOAT FALLS NUMBER 3 AND WEIGHT TEST THE NEW RESCUE BOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989
Resolved
WIEGHT TEST THE LIFERAFT DAVITS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Fire Fighting
Issued 16 May 1989
Resolved
REFILL THE TWO EMPTY HALON SPHERES AND MAKE THE STARBOARD PUMP ROOM HALON SYSTEM OPERABLE. REPLACE THE 3 CORRODED CIRCUIT BOARDS ON THE PORT PUMPROOMHALON PANEL.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989
Resolved
REPAIR THE TRANSMISSION IN THE NEW LIFEBOAT NUMBER 3 AND SATISFACTORY TEST THE BOAT IN THE WATER BEFORE ASSIGNING PERSONNEL TO THE BOAT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 16 May 1989
Resolved
MAKE THE LOSS OF PURGE AIR ALARM OPERABLE ON SUBSEA MONITOR. REPORT SATISF-ACTORY TEST OF ALARM TO MSO MORGAN CITY.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Navigation
Issued 16 May 1989
Resolved
MAKE ALL PRESSURE VESSELS EXCEPT THE BULK TANKS AVAILABLE FOR INTERNAL EXAMAND TEST ASSOCIATED RELIEF VALVES IN THE PRESENCE OF A COAST GUARD INSP.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Lifesaving
Issued 16 May 1989
Resolved
MAKE BULK TANKS 2,5,6,7,8,9, AND 10 AVAILABLE FOR AN INTERNAL EXAM BY A COAST GUARD INSPECTOR.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Electrical
Issued 10 May 1989
Resolved
REPLACE TWO MISSING BOLTS ON DRIVER PORTION OF EXPLOSION PROOF SPEAKER LOCATED IN MUD PITS.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
REMOUNT OR REMOVE LOSE WIRING ON SHALE SHAKER STBD SIDE BULKHEAD. REPLACE EYS FITTING BEING USED FOR JUNCTION BOX WITH APPROVED EXPLOSION PROOF JUNCTION BOX FOR CLASS I DIVISION I AREA.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOX IN DOG HOUSE STBD SIDE AFT DRILL FLOOR
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Fire Fighting
Issued 10 May 1989
Resolved
SERVICE FIXED HALON SYSTEMS TO ACCOUNT FOR DESCREPANCIES IN LAST SERVICE REPORT AND APPROVED CALCULATIONS AND CYLINDERS. PRESENTLY APPROXIMATLY 800LBS SHORT.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Navigation
Issued 10 May 1989
Resolved
RENEW STBD FWD OBSTRUCTION LIGHT.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
POUR EYS FITTING ON SWACO UNIT MOTOR JUNCTION BOX LOCATED PORT SIDE SHALE SHAKER EXTERIOR.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
ADD EYS FITTING TO MOTOR FOR HELICOPTER REFUELING PUMP, CLASS I DIVISION I AREA.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
PROVIDE DOCUMENTS TO ENSURE DRIVE BELTS ON THE SWACO UNIT ARE OF THE STATICGUARD TYPE.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
CHECK AND POUR ALL EYS FITTINGS ON GAUTHER BROTHERS MUD CENTRIFUCE RENTAL UNIT.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
POUR EYS FITTING ON JUNCTION BOX LOCATED PORT SIDE SHALE SHAKER EXTERIOR.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
CHECK AND POUR ALL EYS FITTING IN SHALE SHAKER AREA. ENSURE POURED AREAS ENCOMPASS INDIVIDUAL CONDUCTORS.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Unknown
Issued 10 May 1989
Resolved
HOLD FIRE/LIFEBOAT DRILL IN PRESENCE OF USCG MARINE INSPECTOR ( HOLD WHEN WT. TESTING LIFEBOATS)
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
TEST IN THE PRESENCE OF A COAST GUARD INSPECTOR (1) SUBSEA MONITOR PURGE (2) DRILLERS CONSOLE LOSS OF PURGE ALARM (3) ALL PURGED SERVICE EQUIPMENT LOSS OF PURGE ALARMS (4) LOSS OF MUD PIT VENTILATION ALARMS.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
PROVIDE BONDING BETWEEN ALL FLANGE TO FLANGE CONNECTIONS ON HELOCOPTER REFUELING PIPING. CL I DIV I AREA.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Unknown
Issued 10 May 1989
Resolved
REPLACE WASTED BOLTS ON FLANGE TO FLANGE CONNECTIONS ON HELOCOPTER REFUELING PIPING.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Deck/Cargo
Issued 10 May 1989
Resolved
MAKE AVAILABLE ALL PRESSURE VESSELS FOR BIENIAL INTERNAL EXAM AND ASSOCIATED RELIEF VALVES FOR TESTING IN THE PRESENCE OF A USCG MARINE INSP.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Lifesaving
Issued 10 May 1989
Resolved
RENEW FALLS AND PENANTS ON #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Lifesaving
Issued 10 May 1989
Resolved
WEIGHT TEST ALL LIFEBOAT AND LIFE AFT DAVITS IN THE PRESENCE OF A USCG MARINE INSPECTOR
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Electrical
Issued 10 May 1989
Resolved
TEST RIG SHUTDOWN IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Fire Fighting
Issued 31 May 1988
Resolved
PROVIDE COPY OF ANNUAL FOAM ANALYSIS REPORT.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Documentation
Issued 31 May 1988
Resolved
LOCATE AND PAINT IN A CONSTRASTING COLOR, THE VESSEL'S LOADLINE.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Fire Fighting
Issued 31 May 1988
Resolved
PROVIDE WITH APPROPRIATE VAPOR TIGHT FITTING THE ACTUATION SWITCH, ELECTRICSIDE ONLY, FOR HALON SYSTEM IN PAINT LOCKER.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Navigation
Issued 31 May 1988
Resolved
MAKE FOG HORN AUDIBLE FOR A MINIMUM OF TWO (02) MILES AS PER 33 CFR 67.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Documentation
Issued 31 May 1988
Resolved
PROVIDE ONBOARD A VALID FCC CERTIFICATE.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Construction/Loadline
Issued 29 December 1987
Resolved
RESUBMIT YOUR SPECIAL EXAM IN LIEU OF DRYDOCKING PROPOSAL TO REFLECT INSPECTION BEING PERFORMED AT WORKING DRAFT VICE LIGHT DRAFT AS STATED FOR APPROVAL.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Construction/Loadline
Issued 29 December 1987
Resolved
COMPLETE UNDERWATER PORTION OF SPECIAL EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Construction/Loadline
Issued 29 December 1987
Resolved
SUBMIT PROPOSAL FOR EFFECTING REPAIRS TO DAMAGE ON PORT AND STBD CENTER CAISSONS, OUTBD. INCLUDE YOUR ANTICIPATED TIME SCHEDULE FOR EFFECTING SAME.REPAIRS NOT TO BE COMMENCED WITHOUT PRIOR APPROVAL OF [name withheld] THE OUTER CONTINENTAL SHELF SECT. ([phone withheld]) 46 CFR 107.275
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Engineering
Issued 12 May 1987
Resolved
DEMONSTRATE OPERABLE BILGE ALARM FOR PORT AND STBD PUMP ROOMS.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
DAVIT ARMS AND HOOKS FOR INFLATABLE RAFT STATIONS TO BE WEIGHT TESTED IN PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 12 May 1987
Resolved
LABEL VALVES TO HYDRANT STATIONS NO.2 FOAM AND NO.2 FIRE STATION. THESE TWOHYDRANT STATIONS ARE LOCATED NEXT TO ONE ANOTHER AND THEIR HOSES FOUND MIS-CONNECTED.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 12 May 1987
Resolved
RE-ACTIVATE SPRINKLER SYSTEM ON RIG AND PROVE ITS OPERATION, OR REMOVE SYSTEM FROM RIG.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 12 May 1987
Resolved
RE-ACTIVATE FIRE CONTROL SENSORS AND BELLS OR PROVE IT'S OPERATION; OR REMOVE SYSTEM FROM RIG.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 12 May 1987
Resolved
PROVIDE HIGHER PROTECTION FIRE FIGHTING BOOTS FOR EACH FIRE FIGHTING OUTFIT(OR LONGER LENGTH FIRE FIGHING OVER COAT).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Electrical
Issued 12 May 1987
Resolved
RENEW CRACKED EYS FITTING TO MUD CIRCULATING PUMP #6, MUD PIT ROOM.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Electrical
Issued 12 May 1987
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF LOW LUBE OIL PRESSURE SHUTDOWN AND HIGH ENGINE TEMPERATURE ALARM FOR EMERGENCY GENERATOR DIESEL ENGINE.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 12 May 1987
Resolved
LABEL #3 COLUMN BILGE ISOLATION VALVE.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Accommodation/Occupational Safety
Issued 12 May 1987
Resolved
MAKE TENSIONER BOTTLES AVAILABLE FOR INTERNAL INSPECTION AT NEXT RIG MOVE.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Electrical
Issued 12 May 1987
Resolved
MAKE EMERGENCY LIGHTING OPERABLE IN PORT AFT COMPARTMENT (ELEVATOR) AND LIGHTS IN PORTY FORWARD ELEVATOR.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Electrical
Issued 12 May 1987
Resolved
MAKE OPERABLE THE FOLLOWING GENERAL ALARMS: (2) ON MAIN DECK PORT SIDE; (1) ON FRONT OF ACCOMMODATION HOUSE PORT SIDE; (1) SHALE SHAKERS; (1) PORT CRANE ON FWD PEDESTAL; (1) IN MUD PITS; (2) ON DRILL FLOOR.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Accommodation/Occupational Safety
Issued 12 May 1987
Resolved
MAKE THE FOLLOWING BULK/TANKS AVAILABLE FOR INTERNAL INSPECTION; #1,3,4,6,810 & 12
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
REPLACE INCORRECT DAVIT LAUNCH RAFT OPERATING INSTRUCTIONS WITH CORRECT MASECO INSTRUCTIONS AT STERN RAFT STATION.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 12 May 1987
Resolved
PROVIDE AN ADDITIONAL OPERABLE, FM OR UL APPROVED, O2/COMBUSTIBLE GAS INDICATOR.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
CHANGE FUEL OIL IN NO.3 LIFEBOAT (23-MAN), OR PROVIDE EVIDENCE THAT FUEL HAS BEEN CHANGED WITHIN THE LAST 12 MONTHS.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Documentation
Issued 12 May 1987
Resolved
REVISE THE FUEL OIL TRANSFER PROCEDURES TO HAVE IT COMPLY WITH 33 CFR 155.750. THE CONTANTS ARE TWO BRIEF AND DO NOT CONTAIN ALL THE INFORMATIONREQIURED PER THE REFERENCE.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Documentation
Issued 12 May 1987
Resolved
OIL RECORD BOOK TO BE MAINTAINED IN ACCORDANCE WITH 33 CFR 151.25
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 12 May 1987
Resolved
REPAIR DISTORTED STERN LIGHT NAVIGATION SCREEN.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Navigation
Issued 12 May 1987
Resolved
RESET AUTOMATIC FOG SIGNAL DEVICE FOR SIGNAL TO COMPLY WITH ARTIFICIAL ISLANDS AS PER 33 CFR 67.10 AND/OR COLREGS RULE 35 (33 CFR 80).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
REMOVE FROM THE RIG ALL NON (U.S. COAST GAURD) APPROVED HELLY-HANSEN SURVIVAL SUITS (IE., EXPOSURE SUITS).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
PROVIDE A WHISTLE AND APPROVED WATERLIGHT FOR EACH SURVIVAL SUIT MAINTAINEDABOARD THE RIG.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Fire Fighting
Issued 12 May 1987
Resolved
LABEL ALL FOAM SYS. CONTROL VALVES IN ACCORDANCE WITH THE POSTED OPERATING INSTRUCTIONS (IE., A,B,C, OR D).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 30 June 1986
Resolved
PROVIDE RELIEF VALVES ON THE FOLLOWING AIR RECEIVERS THAT WILL RELIEVE AT NOT MORE THAN 150 PSI; STARBOARD AFTER PUMP ROOM, BOTH RIG AIR RECEIVERS.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Lifesaving
Issued 30 June 1986
Resolved
REPAIR/REPAIR THE FOLLOWING ITEMS IN THE RESCUE BOAT: REPLACE BROKEN GLASSIN THE RESCUE BOAT, REPAIR EXHAUST LEAKS& ENGINE SMOKES EXCESSIVELY, REPAIRFRACTURED FIEBERGLASS, CABIN SHELL.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Lifesaving
Issued 30 June 1986
Resolved
REPLACE CABIN GLASS WINDOWS IN BOTH CAPSULES DUE TO FROSTING.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Navigation
Issued 30 June 1986
Resolved
MAKE OPERATIONAL THE FOG HORN; 33CFR67.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Construction/Loadline
Issued 30 June 1986
Resolved
MAKE REPAIRS TO THE STARBOARD CENTER COLUMN; #20 SQUARE FEET AT APPROX THE 80' DRAFT MARK.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Deck/Cargo
Issued 30 June 1986
Resolved
DAMAGE AREA FOR ITEM 6 WAS MARKED INITIALLY ON THE INSIDE OF THE COLUMN.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Accommodation/Occupational Safety
Issued 30 June 1986
Resolved
MAKE OPERATIONAL THE SPRINKLER CONTROL PANEL AND PROVE SATISFACTORY OPERATION OF THE SPRINKLER SYSTEM.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Fire Fighting
Issued 30 June 1986
Resolved
PROVIDE ONBORD THE RIG STAMPED APPROVED COPIES OF THE FOLLOWING: FIRE CONTROL PLAN, HAZARDOUS LOCATION PLAN, CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Lifesaving
Issued 30 June 1986
Resolved
REPAIR/REPLACE RELIEF VALVE ON THE BREATHING AIR SYSTEM, #1 CAPSULE.
Condition: Unknown
Due 30 June 1986
Resolved 30 June 1986
Lifesaving
Issued 5 June 1985
Resolved
REPAIR GENERAL ALARM BELLS WHERE INOPERATIVE THROUGHOUT THE VESSEL REF 46 CFR 113.25-9.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 5 June 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PENROD 76 DN654701
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Lifesaving
Issued 5 June 1985
Resolved
REMOVE KNOTED MANROPES LOCATED AT LIFEBOAT EMBARKATION STATIONS REF 46CFR 108.527.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 5 June 1985
Resolved
PROVIDE STAMPED APPROVED OPERATING MAN VAL ON BOARD RIG REF 46CFR109.121.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Deck/Cargo
Issued 5 June 1985
Resolved
PORVIDE FOR INTERNAL INSPECTION THE FOLLOWING DRILL AIR RECEIVER2) BULK AIRRECEIVER 3) STBD PUMP RM AIR REC 4) EMERGENCY AIR REC STBD PUMP RM 5) AIR FOAM TANK BY HELO DECK (46 CFR 61.10.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Electrical
Issued 5 June 1985
Resolved
REPAIR LOW LUBE OIL PRESSURE ALARM ON GENERATOR DIESEL NO 2 REF 46 58.10
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 5 June 1985
Resolved
REPAIR AND TEST LIMIT SWITCH ON THE NO 2 LIFEBOAT FWD DAVIT REF 46 CFR 111.95
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Navigation
Issued 5 June 1985
Resolved
PROVIDE A BELL ON BOARD VESSEL REF COLREGS ANNEX 111(2).
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 5 June 1985
Resolved
PROVIDE DESIGNATION D OR DS ON FORKLIFT REF 46 CFR 108.613.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 5 June 1985
Resolved
PROVIDE UL OR FM APPROVAL ON FORKLIFT REF 46 CFR 108.613.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Electrical
Issued 5 June 1985
Resolved
PROVIDE LIGHTING IN ESCAPE HATCHS FROM PUMP ROOMS PORT AND STBD REF 46 CFR 112.15(C).
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Electrical
Issued 5 June 1985
Resolved
PROVIDE UL OR FM APPROVED SWITCHES ON TWO FIRE ACARM BOXES ON DRILL FLOOR REF 46 CFR 111.105.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Electrical
Issued 5 June 1985
Resolved
PROVIDE UL OR FM APPROVED SWITHES TO MOTORS FOR DEGASER AND MUD CLEANER IN SHALE SHAKER AREA REF 46 CFR 111.105.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Electrical
Issued 5 June 1985
Resolved
PROVIDE UL OR FM APPROVED SWITCHES FOR THREE FAN MOTORS LOCATED AT MUD PIT AREA REF 46 CFR 111.105.
Condition: Unknown
Due 5 June 1985
Resolved 5 June 1985
Unknown
Issued 20 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 76, DN654701.
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Electrical
Issued 20 April 1984
Resolved
REPAIR LOSS OF PURGE AIR INDICATORS ON TOTCO UNIT ON DRILL FLOOR. 46CFR111.105
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Fire Fighting
Issued 20 April 1984
Resolved
PROVIDE A UL OR FM APPROVED OXYGEN AND EXPLOSIVE METER FOR EACH OF THE FIREMANS OUTFITS ON BOARD. 46CFR108.497
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Unknown
Issued 20 April 1984
Resolved
(REQ 6B CONTINUE) 46CFR160.40
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Lifesaving
Issued 20 April 1984
Resolved
PROVIDE 1500 FEET OF AUXILLARY LINE FOR LINE THROWING GUN EITHER 3 INCH MANILA OR POLYPROPOLENE WITH AT LEAST 9000 LBS. BREAKING STRENGHT.
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Lifesaving
Issued 20 April 1984
Resolved
REPAIR OR REMOVE RESCUE BOAT. 46CFR108.103
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Electrical
Issued 20 April 1984
Resolved
LABEL ALL EMERGENCY LIGHTS WITH PROPER SIZE LETTERING. 46CFR108.639
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Fire Fighting
Issued 20 April 1984
Resolved
PROVIDE APPROVED LOW VELOCITY FOG APPLICATORS FOR FOUR (4) FIRE STATIONS SERVING MACHINERY SPACES. 46CFR108.425
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984
Accommodation/Occupational Safety
Issued 20 April 1984
Resolved
PROVIDE PROPER RELIEF DEVICES FOR ALL TWENTY-ONE (21) TENSIONER BOTTLES. 46CFR61.10-5
Condition: Unknown
Due 20 April 1984
Resolved 20 April 1984