J. W. MCLEAN

J. W. MCLEAN is a 1970 mobile offshore drilling unit. The Coast Guard has recorded 8 inspections since 1985, most recently in February 1989, along with 49 deficiencies.

Records from 1985 to 1989. Most recent: inspection, 10 February 1989.

Built
1970
Last inspected
10 February 1989
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WZU8815
Flag
PANAMA
—
Maury page id
psix-55174

Inspections, by type

…with no type recorded4
Years with a record 4 calendar years (1985–1989)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3572 - Regulatory (Subpart C or D), Gross Ton
3572 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

10 February 1989 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034016
8 January 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1008044
2 December 1986 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1329200
2 May 1986 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 999716
18 September 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 986402
9 August 1985 Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1295171
2 June 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1285791
12 April 1985 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1291209

Deficiency record · 49

Unknown
Issued 2 May 1986 Resolved
REMOVE ALL DEAD ENDED ELECTRICAL CABLES AND SUPPORT ALL HANGING ELECTRICAL CABLES UNDER DRILL FLOOR.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE REPAIRS TO THE FIRE MAIN PIPING IN WAY OF THE DETERIORATED AND PATCHED SECTION IN THE ENGINEERS STORE ROOM. PIPING SHALL BE CROPED TO GOOD METAL AND RENEWED.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE REPAIRS TO FIRE PUMP NO. 1 AND 2 SHAFT PACKING AND FIRE MAIN DISCHARGE PIPING IN WAY OF DETERIORATED AND PATCHED SECTIONS. PIPING SHALLBE CROPED TO GOOD METAL AND RENEWED.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
SUBMIT REPAIR PROCEDURE AND PROVIDE REPAIRS TO THE STBD SIDE OF COLUMN NO. 2 DAMAGED AREAS BETWEEN THE 75 AND 85 FOOT LEVEL.
Condition: Unknown
Due 30 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 2 May 1986 Resolved
PROVIDE SERVICING FOR THE STBD AFT LIFERAFT AT A USCG APPROVED FACILITY. THERE SHALL BE SUFFICIENT LIFERAFTS ON BOARD FOR A TOTAL OF 91 PERSONS.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE A USCG APPROVED AUTOMATIC DISENGAGING DEVICE FOR THE PORT LIFERAFT DAVIT.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE 62 GALLONS OF WATER, FLOATING ORANGE SMOKE SIGNAL AND ENGINE OPERATING MANUAL, FOR THE STBD LIFEBOAT.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE 33 POUNDS OF PROVISIONS, FLOATING ORANGE SMOKE SIGNAL, DRINKING CUP, FIRST AID KIT, 49 GALLONS OF WATER AND 214 OUNCES OF CONDENSED MILK, FOR THE PORT LIFEBOAT.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE HYDROSTATIC TESTING AND REFILL ALL HOSPITAL OXYGEN CYLINDERS, AND PROVIDE SUFFICIENT FIRST AID MATERIALS MEETING MESH OR MSHA STANDARDS.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE OPERABLE SMOKE DETECTORS WITHIN THE ACCOMMODATION SPACES.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE REPAIRS TO FIRE MAIN PIPING IN WAY OF DETERIORATED SECTION AT STAION NO. 8. PIPING SHALL BE CROPED TO GOOD METAL AND RENEWED.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE PERMANENT REPAIRS TO THE DEEP WELL PUMPS DISCHARGE PIPING. CROP THE PATCHED AREA TO GOOD METAL AND RENEW.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE CORRECTIONS TO THE SAFETY EQUIPMENT LAYOUT DRAWING SHOWING AS INSTALLED EQUIPMENT, BERTHING AREA ALTERATIONS AND SUBMIT THEM FOR USCG APPROVAL.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
MUNBER OF BERTHS AND PERSONNEL ONBOARD ARE 98. SUBMIT FOR USCG APPROVAL AND AMENDMENT TO THE CERTIFICATE OF INSPECTION INCREASING TOTAL NUMBER OF PERSONNEL FROM 91 TO 98.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE PERMANENT REPAIRS TO THE INSTALLED GAS DETECTION SYSTEM AND PROVE OPERATION.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE A FIRE NOZZLE AT FIRE STATION NO. 7.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE REPAIRS TO THE BILGE PUMPING SYSTEM AND PROVE ITS OPERATION.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE REPAIRS TO NO. 1 GENERATOR LOW LUBRICATING OIL PRESSURE ENGINE SHUT DOWN AND ALARM.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE A GENERAL ALARM BELL WITHIN THE HALLIBURTON PUMP ROOM SPACE, AND PROVIDE REPAIRS TO THE GENERAL ALARM BELL ON THE DRILL FLOOR.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE A LOW VELOCITY SPRAY APPLICATOR TO FIRE STATIONS SERVICING THE MACHINERY SPACES.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE A FIRE HYDRANT NEXT TO THE FORWARD ACCESS TO THE HELICOPTER DECK, AND A LOW VELOCITY SPRAY APPLICATOR AT THE TWO FIRE STATIONS.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE REPAIRS TO THE MUD PIT DOORS MAKING THEM SELF-CLOSING AND GAS TIGHT.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE REPAIRS TO DETERIORATED RETURN MUD PIPING, MUD PUMP ROOM.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE A HIGH VELOCITY FIRE NOZZLE TIP AT FIRE STATION NO. 10.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Unknown
Issued 2 May 1986 Resolved
PROVIDE AN AIR PURGE AND PURGE INDICATOR TO THE DRILL FLOOR ROTARY TABLE ELECTRIC MOTOR, ELECTRICAL ENCLOSURE ABOVE DRILLERS CONSOLE, ALARMS, INTER-COMMS, HYDRAULIC PUMPS, MOTOR CONTROLLER, CURLEE ELECTRICAL ENCLOSURE AND ALARM BELL CONTACT MAKER.
Condition: Unknown
Due 2 May 1986
Resolved 2 May 1986
Lifesaving
Issued 9 August 1985 Resolved
PROVIDE ONE ADDITIONAL HANDHELD RED DISTRESS FLARE FOR STARBOARD LIFEBOAT.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Lifesaving
Issued 9 August 1985 Resolved
PROVIDE NEW BRAKE RELEASE CABLE FOR PORT LIFEBOAT.
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Lifesaving
Issued 9 August 1985 Resolved
HAVE BOTH AUTOMATIC DISENGAGING DEVICES FOR BOTH DAVIT LAUNCHED LIFERAFTS REPAIRED AND RETESTED IN ACCORDANCE WITH 46 CFR 107.239(C).
Condition: Unknown
Due 9 August 1985
Resolved 9 August 1985
Documentation
Issued 12 April 1985 Resolved
OBTAIN AND MAINTAIN A USCG OIL RECORD BOOK PER 33 CFR 151.25.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
FOR THE NEW LIFEBOAT DAVIT INSTALLATION SUBMIT WELDING PROCEDURES FOR APPROVAL AND QUALIFY WELDERS FOR THESE PROCEDURES PER 46CFR57.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985 Resolved
CONDUCT WEIGHT TESTS OF DAVIT LAUNCHED LIFERAFT LAUNCHING EQUIPMENT IN ACCORDANCE WITH 46 CFR 107.239 TO SATISFACTION OF THE ATTENDING USCG INSPECTOR.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Electrical
Issued 12 April 1985 Resolved
INSTALL AN ALARM IN A MANNED CONTROL STATION TO INDICATE LOSS OF VENTILATION IN THE MUDPIT ROOM IN ACCORDANCE WITH 46 CFR 108.175(C).
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985 Resolved
REPAIR OR RENEW 76 LIFE PRESERVERS AND PROVIDE THEM FOR INSPECTION AND STAMPING BY ATTENDING USCG INSPECTOR. A TOTAL OF 114 LIFE PRESERVERS EQUIPPED PER 46 CFR 108.514 ARE REQUIRED.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Documentation
Issued 12 April 1985 Resolved
OBTAIN AN APPROVED OPERATIONS MANUAL AND STABILITY LETTER.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Accommodation/Occupational Safety
Issued 12 April 1985 Resolved
OPEN AND CLEAN FOR INSPECTION OR HYDROSTATICALLY TEST SIX P-TANKS TO THE SATISFACTION OF THE ATTENDING USCG INSPECTOR PER 46 CFR 61.10-5(B).
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE A STANDARD DISCHARGE CONNECTION PIECE PER DIMENSIONS IN MARPOL 73/78 PROTOCOL REGULATION 19 PRIOR TO ISSUANCE OF IOPP CERTIFICATE.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE AN ADDITIONAL FIRE PUMP OR RELOCATE AN EXISTING FIRE PUMP TO A SPACE OUTSIDE THE PUMP ROOM PER 46 CFR 108.421. THE TWO PUMPS SHALL HAVE THE CAPACITY AS REQUIRED BY 46 CFR 108.415.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Fire Fighting
Issued 12 April 1985 Resolved
PROVIDE TWO APPROVED EXPLOSION PROOF FLASHLIGHTS WITH SPARE BATTERIES AND REPAIR ONE EXPLOSIVE METER FOR FIREMAN OUTFITS PER 46 CFR 108.497.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
SUBMIT A REVISED FIRE CONTROL AND SAFETY PLAN FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
REPLACE CLEAR LENS IN STBD RUNNING LIGHT WITH A PROPER GREEN LENS.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE HYDROSTATIC RELEASES FOR LIFERAFTS WITH USCG INSPECTION TAGS SHOWING TEST DATES WITHIN THE LAST 12 MONTHS.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
REVIEW THE ONE EMBARKATION LADDER FOR LIFERAFT STATIONS NOS. 5 AND 6.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE ONE 1500 FOOT MANILA AUX. LINE OR SYNTHETIC EQUIVALENT WITH BREADKING STRENGTH OF AT LEAST 9,000 LBS FOR LINE THROWING APPARATUS.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
CLOSE INTERIOR STAIRWAYS AT A MINIMUM OF ONE LEVEL WITH SELF-CLOSING A-CLASS DOORS AT EITHER DECK OR OVERHEAD LEVEL PER NVC 4-78, 3.D.(7) AND 46CFR 108.143.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE AT LEAST 2 USCG CLASS AII PORTABLE FIRE EXTINGUISHERS WITH BRACKETS FOR EACH ACCOMMODATION CORRIDOR PER NVC 4-78 3.D.(7)(B).
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
REPLACE ALL ELEC EQUIP NOT RATED FOR CLASS I DIV 2 HAZ LOCATIONS FOR SPACESCONTINGEOUS TO THE MUD PIT OR PROVIDE ACCEPATBLE ALTERNATIVES PER 46CFR 108.175 (C) TO MAKE SPACES NON-HAZ LOCATIONS.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE A COPY OF THE LATEST CARGO GEAR CERTIFICATES FOR THE INSTALLED CRANES.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE DOCUMENTATION THAT CRANE TESTS WHICH WERE CONDUCTED ON 27 AUG 84 AND WITNESSED BY ABS MEET THE API SPECIFICATION PER 46 CFR 107.259.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Unknown
Issued 12 April 1985 Resolved
PROVIDE A CRANE RECORD BOOK FOR THE RIG AND DESIGNATE IN WRITING ALL CRANE OPERATORS.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.