Records from 2016 to 2026. Most recent: inspection, 18 June 2026.
Documentation record
Registered dimensions (L × B × D)61.0 ft × 16.6 ft × 7.7 ft
Registered tonnagegross 50 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT · LOREAUVILLE, LA, UNITED STATES · built 1976
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portINGLESIDE, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 22 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 18
18 June 2026
Vessel Attendance · Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8391324
4 December 2025
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8277799
28 May 2025
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8146303
9 August 2024
Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7977883
24 October 2023
Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7813594
10 July 2023
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7738571
26 May 2023
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7696992
7 November 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7590554
6 May 2022
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7445242
20 October 2021
Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7336332
24 June 2020
COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6980244
3 October 2019
Examination of Repairs · Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6827670
25 July 2019
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6761387
12 July 2018
Deficiency Check · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6476380
20 November 2017
Hull Examination · In-Service Inspection · Damage Survey · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6310871
17 October 2017
Deficiency Check · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6289363
28 July 2017
Administrative Inspection · Annual Inspection · In-Service Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6215400
10 August 2016
Simplified Stability Test
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5968861
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 August 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel did not have up-to-date charts and could not provide logs of updates made to the ECDIS. Ensure charts or ECDIS are up to date to the satisfaction of the attending Marine Inspector.
46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 26 August 2024
Resolution: Provided receipt of purchased papaer charts.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 20 August 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Radio Station Certificate was expired; station re-certified by FCC to the satisfaction of the attending Marine Inspector.
46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2024
Resolved 22 August 2024
Resolution: Owner provided document in an email.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 12 July 2018
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF–DSC frequency transmitter meeting the requirements of §80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz. The MF–DSC transmitter and receiver must be capable of operation on 2670 kHz. Vessels MF-DSC radio was not checked for proper operation and installation under the Radiotelephone Safety Certificate. Vessels is restricted to a 20 nautical mile limitation from land.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 August 2018
Resolved 7 August 2018
Resolution: Received a newly issued Communications Act Safety Radiotelephony Certificate for the M/V Gulf Star dated 06Aug2018. All required equipment shows to be properly checked in accordance with the vessels route.
Construction/Loadline › Hull › Hull Plating
Issued 21 November 2017
Resolved
Self reported water ingress along the water line on port side engine room.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 November 2017
Resolved 29 November 2017
Resolution: Cropped and renewed hull plating to the satisfaction of the attending marine inspector.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 October 2017
Resolved
Port and starboard navigation light screens require matt black paint. Paint is faded.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Screens were repainted.
Electrical › Electric Supply System (service) › Cable
Issued 17 October 2017
Resolved
Anchor light power supply conduit requires water proofing. Cable conduit into junction box is not sealed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Repaired space between junction box and conudit.
Stability › Watertight Integrity › General
Issued 17 October 2017
Resolved
Engine room bulkhead in aft steering (port side) is not watertight due to removal of mounted equipment. Repair holes to regain watertight integrity.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Sealed holes in bulkhead.
Engineering › Steering Gear System › Rudder Stock
Issued 17 October 2017
Resolved
Starboard rudder post had 2x2 mm hole from corrosion. Repair hole to original condition.
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Spot welded the effected area filling in hole.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 17 October 2017
Resolved
All through hull fitting, including the hull plating and plankings, appendages, propellers, shafts, bearing, rudders, sea chests sea valves, and sea stainers shall be made aviable for examination. Propellers must be removed for inspection of keyway on shaft.
Action required: 705 - Other - as specified
Due 17 October 2017
Resolved 19 October 2017
Resolution: Removed propellers and made available for inspection.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 17 October 2017
Resolved
Cutlass bearing on starboard side has excessive wear. Replace to original condition.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 November 2017
Resolved 2 November 2017
Resolution: Replaced both cutlass bearings.
Construction/Loadline › Hull › Hull Plating
Issued 28 July 2017
Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull shall be made without the knowledge or approval of the OCMI. Vessel stern deck has a doubler plate over a wasted insert as viewed in aft rudder room.
Action required: 705 - Other - as specified
Due 16 August 2017
Resolved 8 August 2017
Resolution: Repairs were completed to the satisfaction of attending Marine Inspector.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 28 July 2017
Resolved
Cable runs through engine room and accommodation space bulkhead are not vapor tight. Machinery and fuel tank spaces shall be separated from accommodation spaces by wateright and vapor tight bulkheads. Make bulkhead water and vapor tight. 46 CFR 182.35-1(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Bulkhead has been made water & vapor tight.
Engineering › Bilge Water Management System › Piping
Issued 28 July 2017
Resolved
Forward bulkhead in engine room has a plastic pipe fitting (covering a bilge suction line) penetrating the bulkhead. Penetration of watertight bulkheads by any rigid plastic pipe or fitting is prohibited unless it is accomplished with and acceptable metalic fitting welded or otherwise attached. Correct to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Bulkhead penetrations have been made watert tight with a metalic fitting.
Construction/Loadline › Structures › Scuttle
Issued 28 July 2017
Resolved
Emergency escapes are not labelled. All escape hatches shall be marked on both sides "Emergency Exit, Keep Clear" in 1" lettering. Properly label escape hatches. 46 CFR 185.30-15
Action required: 705 - Other - as specified
Due 9 August 2017
Resolved 2 August 2017
Resolution: Escape hatches have been properly labled with 1-inch lettering.
Engineering › Fuel Oil Service System › Ventilation
Issued 28 July 2017
Resolved
Mesh on fuel vents is painted and past serviceable life. Discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters consisting of a single screen of 30x30 mesh. Replace to satisfaction of attending marine inspector.
Action required: 705 - Other - as specified
Due 8 August 2017
Resolved 2 August 2017
Resolution: Fuel vent has been fitted with flame screens / mesh.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 28 July 2017
Resolved
Vessel's alcohol test strips are expired. There must be a sufficient number of alcohol testing devices on board. Obtain alcohol test strips that are not expired. 46 CFR 4.06-15
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 August 2017
Resolution: New alcohol strips have been acquired.