Records from 2016 to 2026. Most recent: inspection, 25 June 2026.
Inspection history · 18
25 June 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8413771
14 April 2026
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8349703
14 May 2025
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8088650
31 October 2024
Examination of Repairs · Plan Review "T" Boat
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8035666
18 July 2024
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873649
21 March 2024
Drydock Exam · Administrative Inspection · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873699
22 June 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7645998
21 June 2022
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411310
12 April 2022
Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7408523
15 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161406
7 May 2020
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6908354
16 April 2020
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6903964
18 July 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6637835
21 June 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375264
30 November 2017
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6307545
22 June 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105792
23 June 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5830599
14 April 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829299
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 21 June 2022
Resolved
Portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel fire extinguisher was manufactured in 2005 and is over 12 years old.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: A new fire extinguisher was placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 June 2022
Resolved
A vessel not more than 26' in length must carry a minimum of one life buoy of not less than 20" in diameter. Ring life buoy is no longer serviceable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 21 June 2022
Resolution: A new properly marked ring life buoy was placed onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 15 July 2021
Resolved
Gauges to indicate jacket water discharge temperature and lubricating oil pressure must be provided for all propulsion engines installed in a vessel. Vessel did not have gauges readily visible at operating station nor on the engine as allowed by Sector SE New England special considerations for launch vessels. Install gauges to satisfaction of CG marine inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2021
Resolved 19 August 2021
Resolution: Gauges were installed on the vessel.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 30 November 2017
Resolved
Repair / replace.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2017
Resolved 23 April 2018
Engineering › Shafting/Propeller Arrangements › Stern Tube Bearing
Issued 30 November 2017
Resolved
Replace cutlass.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 December 2017
Resolved 23 April 2018
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 June 2017
Resolved
Replace fireboy to allow proper testing of alarm function.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2017
Resolved 23 June 2017
Resolution: Replaced existing fireboy system and conducted satisfactory testing in presence of marine inspector.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 22 June 2017
Resolved
Install lifejacket donning placard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 23 June 2017
Resolution: Provided photo of properly installed placard.