Records from 1985 to 2026. Most recent: inspection, 24 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 49
24 April 2026
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8327925
23 April 2025
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8117117
21 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7939400
1 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7903979
19 April 2024
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7897752
21 July 2023
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7745015
7 December 2022
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7604203
22 April 2022
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7439623
8 April 2021
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7159391
8 December 2020
Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7141900
18 September 2020
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7057612
27 March 2020
Drydock Extension · Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6932241
23 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6646603
20 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6379863
2 April 2018
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6379877
26 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6114308
14 April 2016
COI Inspection · DAPI Audit · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5853606
5 May 2009
Simplified Stability Test · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3458074
27 May 2008
Deficiency Check · Hull Examination · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3219370
30 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3138989
17 April 2007
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2908906
14 April 2006
COI Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2624046
27 April 2005
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2492436
16 April 2004
Annual Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2040115
26 June 2003
Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1824424
23 April 2002
MARPOL Annex V Examination · Hull Examination · Re-Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1606623
27 March 2001
Deficiency Check · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1459708
20 April 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1365833
20 April 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1408528
22 March 2000
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1466110
10 May 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 795047
20 April 1999
Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1365171
31 March 1998
Hull Examination · MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1122916
5 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119562
29 August 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 936914
21 September 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879031
12 September 1995
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 883028
9 August 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866329
8 August 1994
COI Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175862
13 February 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 853744
5 May 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1265911
6 May 1991
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232597
7 May 1990
Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1230093
2 May 1989
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1194094
9 May 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038590
22 June 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003937
8 June 1987
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029378
6 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983633
4 January 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285483
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 April 2026
Resolved
Provide VHF with location information broadcasting for DSC capable radio. Prior to operating beyond 1000ft from shore.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 May 2026
Resolved 8 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 23 April 2025
Resolved
Post crew only sign at entry to FWD below deck cabin area.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 23 April 2025
Resolution: Sign posted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 September 2020
Resolved
Label fuel shut-off valves in case of emergency and immediate shut down/ securing of fuel is required
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: Fuel shut off valves labled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2020
Resolved
Name of vessel on the life ring worn. Re-stencil the vessel name on the life ring/ Type 4 PFD
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: Life ring replaced, and relabled with the vessel name.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 September 2020
Resolved
Restrict operations to less than 1000 feet from shore. Provide FCC safety certificate for VHF installations
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: FCC safety certificate provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 September 2020
Resolved
Re-configure or create easier access to the vessel's fuel shut-off valveswhere the cover to the valves was identified seized
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: Fuel shut-off access panel sanded and re-configured to allow for easire access.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2020
Resolved
Remove old/ unused dead-end wires in the machinery space where some dead ends are electrical tape terminated
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: MDE old and unused dead end wires removed from the machinery compartment.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 September 2020
Resolved
Identified adult life jacket label where adult PFDs were no longer stored. Remove old label where PFDs are not stored
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 29 September 2020
Resolution: Old labeling removed.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 10 June 2008
Resolved
Replace missing pull handle lock pin & tamper seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 27 June 2008
Resolution: Replaced
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 June 2008
Resolved
Repair bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 27 June 2008
Resolution: Tested sat.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 10 June 2008
Resolved
Provide 60' of buoyant lifeline for R/B/
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 June 2008
Resolved 27 June 2008
Resolution: new 60'' line fitted
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 10 June 2008
Resolved
Tamper seal missing on portable fire extinguishers. Check condition of extinguisher & replace seal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 27 June 2008
Resolution: found sat
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 June 2008
Resolved
Provide eyewash for firstaid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 June 2008
Resolved 27 June 2008
Resolution: found sat
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 May 2008
Resolved
Conduct a statisfactory drydock exam.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2008
Resolved 28 May 2008
Resolution: Completed
Stability › Incline Test › General
Issued 30 January 2008
Resolved
Conduct stability test
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 April 2008
Resolved 5 May 2009
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 17 April 2007
Resolved
Apply new retro-reflective material to 4 adult lifejackets.
Due 1 May 2007
Resolved 5 June 2007
Resolution: Per attending MI.
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 17 April 2007
Resolved
Prove servicing of Fixed Firefighting system.
Due 1 May 2007
Resolved 5 June 2007
Resolution: Per attending MI.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 April 2007
Resolved
Provide one adult lifejacket.
Due 1 May 2007
Resolved 5 June 2007
Resolution: Per attending MI.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 April 2007
Resolved
Provide aspirin and eyewash.
Due 1 May 2007
Resolved 5 June 2007
Resolution: Per attending MI.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2007
Resolved
Prove proper operation of navigation lights prior to night operations.
Due 1 May 2007
Resolved 5 June 2007
Resolution: Per attending MI.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 April 2005
Resolved
Provide proof of annual servicing of fixed fire system and portable extinguishers prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2005
Resolution: Per fax ltr and receipt fm O/O, scanned into documents for this activity.
Lifesaving › Lifebuoys
Issued 16 April 2004
Resolved
Provide floating line for ring buoy. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Unknown
Due 1 May 2004
Resolved 24 April 2004
Resolution: Per ltr from operator-ltr is in vessel details, documents
Accommodation/Occupational Safety › Medical/First Aid
Issued 16 April 2004
Resolved
Provide first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 1 May 2004
Resolved 24 April 2004
Resolution: Per ltr from operator-ltr is in vessel details, documents
Fire Fighting
Issued 16 April 2004
Resolved
Provide 3 fire buckets LEGACY COMPONENT DESC: Fire buckets
Condition: Unknown
Due 1 May 2004
Resolved 24 April 2004
Resolution: Per ltr from operator-ltr is in vessel details, documents
Pollution Prevention/Response › Prevention Equipment
Issued 16 April 2004
Resolved
Close thru hulls for marine sanitation device. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 1 May 2004
Resolved 24 April 2004
Resolution: Per ltr from operator-ltr is in vessel details, documents
Fire Fighting › Miscellaneous Items
Issued 26 June 2003
Resolved
Provide fire buckets IAW 46 CFR 184.506.
Condition: Improper/Lack of Maintenance
Due 3 July 2003
Resolved 6 July 2003
Resolution: Three 2-1/2 gallon buckets provided.
Communications › Radio Communications
Issued 26 June 2003
Resolved
Provide emergency broadcast placard IAW 46 CFR 184.506. LEGACY COMPONENT DESC: VHF Radiotelephone
Due 3 July 2003
Resolved 6 July 2003
Resolution: Provided and posted.
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 June 2003
Resolved
Provide life jacket donning placard.
Condition: Placed in Improper Service
Due 3 July 2003
Resolved 6 July 2003
Resolution: Provided and posted.
Navigation › Piloting/Steering › Marine Charts
Issued 26 June 2003
Resolved
Provide chart of operating area.
Condition: Improper/Lack of Maintenance
Due 3 July 2003
Resolved 6 July 2003
Resolution: Mooring area charted placed on board.
Lifesaving › Lifejacket/PFD (Type I)
Issued 23 April 2002
Resolved
Renew/repair 1 adult lifejacket. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 17 May 2002
Resolved 13 May 2002
Resolution: New PFD purchased.
Lifesaving › Lifejacket/PFD (General)
Issued 23 April 2002
Resolved
Separate adult and child lifejackets. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 17 May 2002
Resolved 13 May 2002
Resolution: Completed and verified via fax (see documents).
Construction/Loadline
Issued 27 March 2001
Resolved
HATCH TO AFTER STEERING HARD TO OPERATE. REPAIR/RENEW.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Engineering
Issued 27 March 2001
Resolved
HOSE USED FOR FUEL SUPPLY MORE THAN 30" NOT DOUBLE HOSE CLAMP AND IMPROPER.ALL HOSE ASSEMBLIES OVER 30" MUST MEET SAE J1942-1, HOSES 30" LESS MUST BE DOUBLE CLAMPED.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 27 March 2001
Resolved
1 BII FIRE EXT DISCHARGED, ALL OVER DUE SERVICING, INCLUDING FIXED SYSTEM. REPAIR/RENEW PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Lifesaving
Issued 27 March 2001
Resolved
VSL ON BLOCKS, HAVE VSL IN WATER FOR UNDERWAY TEST AND TO CONDUCT DRILLS.
Condition: Unknown
Due 1 June 2001
Resolved 1 June 2001
Fire Fighting
Issued 20 April 2000
Resolved
INSTALL MANUAL PULL CABLE ON FIXED FIRE EXTINGUISHER.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Lifesaving
Issued 20 April 2000
Resolved
REPLACE LIFELINE ON RING BUOY.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Fire Fighting
Issued 10 May 1999
Resolved
CONDUCT INSTALLATION INSPECTION AND TESTS FOR PRE-ENGINEERED HALON SYSTEM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Documentation
Issued 20 April 1999
Resolved
COME INTO COMPLIANCE WITH USCG DRUG TESTING REGULATIONS.
Condition: Unknown
Due 27 April 1999
Resolved 26 April 1999
Unknown
Issued 12 September 1995
Resolved
PROVIDE VISUAL DISTRESS SIGNAL.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Unknown
Issued 12 September 1995
Resolved
STENCIL ALL LIFE JACKETS WITH VESSEL'S NAME.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Unknown
Issued 12 September 1995
Resolved
PROVIDE PROOF OF ANNUAL SERVICE TO FIRE EXTINGUISHERS, INSUFFICIENT CHARGE.
Condition: Unknown
Due 12 September 1995
Resolved 12 September 1995
Electrical
Issued 8 August 1994
Resolved
REMOVE EXISTING WIRES FROM SWITCHBOARD FOR FRESH WATER PUMP.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Lifesaving
Issued 8 August 1994
Resolved
24 ADULTS PFD REQUIRED, 14 REJECTED. VSL NOT TO CARRY MORE THAN 10 ADULTS UNTIL PROVE OF 24 SAQT PFD'S.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Lifesaving
Issued 8 August 1994
Resolved
LABEL ALL NEW PFD'S AS REQUIRED.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Lifesaving
Issued 8 August 1994
Resolved
3 CHILD TYPE PFD REQUIRED, 2 REJECTED. VSL NOT TO CARRY MORE THAN 1 CHILD UNTIL PRVE OF 3 SAT PFD'S.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Electrical
Issued 8 August 1994
Resolved
SECURE BATTERY BOXES TO PREVENT SHIFTING.
Condition: Unknown
Due 12 September 1994
Resolved 12 September 1994
Engineering
Issued 8 June 1987
Resolved
INSTALL FLAME SHIELD ON RAYCOR FUEL FILTER.
Condition: Unknown
Due 8 June 1987
Resolved 8 June 1987