Records from 1984 to 1995. Most recent: inspection, 12 May 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 32
12 May 1995
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1234806
13 May 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 859372
23 October 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 165136
4 June 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 828968
21 May 1993
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 839803
20 May 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1136826
7 April 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1148573
5 June 1992
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1259960
22 May 1992
Drydock Extension · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 955103
9 March 1992
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1009394
29 May 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 906847
18 October 1990
Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1237961
15 August 1990
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 921761
18 June 1990
Deficiency Check · Drydock Extension
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 919071
1 June 1990
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235614
30 January 1990
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 916006
14 July 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1351731
5 July 1989
Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209835
8 June 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 891387
10 June 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 891940
5 February 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1330543
5 January 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1317421
30 November 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335762
18 September 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1006804
12 June 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1028856
14 October 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1319755
30 June 1986
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1307047
20 December 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 996519
17 September 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1297374
4 September 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989826
13 June 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982135
13 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 975818
Documentation
Issued 13 May 1994
Resolved
PROVIDE EVIDENCE OF COMPLYING WITH THE REQUIREMENTS IN 46CFR16 FOR CHEMICAL(DRUG) TESTING OF CREW.
Condition: Unknown
Due 18 May 1994
Resolved 13 June 1994
Documentation
Issued 13 May 1994
Resolved
PROVIDE LICENSES FOR BARGE MASTERS ON BOARD THE VESSEL.
Condition: Unknown
Due 18 May 1994
Resolved 13 June 1994
Documentation
Issued 13 May 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 May 1994
Resolved 13 June 1994
Lifesaving
Issued 21 May 1993
Resolved
CONDUCT FIRE AND MANOVERBOARD DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Documentation
Issued 21 May 1993
Resolved
PROVE EVIDENCE OF COMPLYING WITH THE REQUIREMENTS IN 46 CFR 16 FOR CHEMICAL(DRUG) TESTING OF CREW, INCLUDING RANDOM TESTING.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Documentation
Issued 21 May 1993
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Construction/Loadline
Issued 21 May 1993
Resolved
PROVE PROPER OPERATION OF THE VESSEL'S FIRE FIGHTING AND BILGE SYSTEMS.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Fire Fighting
Issued 21 May 1993
Resolved
REPLACE HINGES ON BOTH FIRE STATION DOORS.
Condition: Unknown
Due 21 May 1993
Resolved 21 May 1993
Lifesaving
Issued 22 May 1992
Resolved
CONDUCT PERSON OVERBOARD AND FIRE DRILLS TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Engineering
Issued 22 May 1992
Resolved
PROVE PROPER OPERATION OF REMOTE FUEL SHUT-OFF FOR GENERATOR.
Condition: Unknown
Due 22 May 1992
Resolved 22 May 1992
Lifesaving
Issued 1 June 1990
Resolved
PROVIDE 13 ADDITIONAL ADULT PFD'S.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Engineering
Issued 1 June 1990
Resolved
RENEW VENT SCREEN FOR STARBOARD FUEL TANK VENT.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Accommodation/Occupational Safety
Issued 1 June 1990
Resolved
PROVIDE TYPE II MSD OR PROVIDE MEANS TO PUMP OUT EXISTING TYPE III MSD.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Lifesaving
Issued 1 June 1990
Resolved
RELABEL RING BUOYS - PORT AFT AND STARBOARD SIDE AND ENSURE THEY ARE FREE TO USE.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Electrical
Issued 1 June 1990
Resolved
PROPERLY DEADEND IN JUNCTION BOX OR REMOVE WIRE IN AFT STORAGE ROOM AND PROPERLY WIRE CONNECTION IN WAY OF WIRE NUT.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Lifesaving
Issued 1 June 1990
Resolved
PROVIDE NEW INSIDE LIFELINES, PROPERLY ATTACH WATERLIGHTS AND PROPERLY MAKEUP PENDANTS FOR ALL THE BUOYANT APPARATUS.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Documentation
Issued 1 June 1990
Resolved
PROVIDE POLLUTION PREVENTION PLACARD AND PROPERLY POST.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Fire Fighting
Issued 1 June 1990
Resolved
PROPERLY MOUNT 2 B-II FIRE EXTINGUISHERS - ONE IN ENGINE ROOM AND ONE IN DRY STORES.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Electrical
Issued 1 June 1990
Resolved
REMOVE ALL EXTENSION CORDS FROM VESSEL.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Accommodation/Occupational Safety
Issued 1 June 1990
Resolved
LABEL BILGE MANIFOLD VALVES.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Fire Fighting
Issued 1 June 1990
Resolved
PROVIDE SUFFICIENT DISCHARGE AND SUCTION HOSE FOR THE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 1 June 1990
Resolved 1 June 1990
Fire Fighting
Issued 8 June 1989
Resolved
PROVIDE VESSEL WITH ONE ADDITIONAL U/L APPROVED 1.5 INCH FIRE HOSE IAW 46 CFR 181.15-10.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Electrical
Issued 8 June 1989
Resolved
PROPERLY SPLICE VHF WIRING IN GALLEY IAW 46 CFR 183.05-50.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Lifesaving
Issued 8 June 1989
Resolved
ATTACH PENDANTS TO EXTERIOR OF BUOYANT APPARATUS IAW 46 CFR 160.010 AND LINES TO WATERLIGHTS IAW 46 CFR 180.15-5.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Electrical
Issued 8 June 1989
Resolved
PROVE PROPER OPERATION OF 12-VOLT EMERGENCY LIGHT IN LOUNGE AREA.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Engineering
Issued 8 June 1989
Resolved
MAKE REPAIRS TO REMOTE FUEL SHUT OFF TO GENERATOR NUMBER THREE.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Electrical
Issued 8 June 1989
Resolved
PROVIDE ELECTRICAL GROUNDS FOR ALL FANS IN VOIDS, T.V. AND VIDEO MACHINES IN LOUNGES.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Fire Fighting
Issued 8 June 1989
Resolved
SERVICE DRY CHEMICAL FIXED FIRE EXTINGUISHING SYSTEM IN GALLEY.
Condition: Unknown
Due 8 June 1989
Resolved 8 June 1989
Lifesaving
Issued 10 June 1988
Resolved
REPAIR AND PROVE PROPER OPERATION OF THREE (03) WATERLIGHTS FOR BUOYANT APPARATUS.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Electrical
Issued 10 June 1988
Resolved
PROVIDE COVER PLATES FOR THE FOLLOWING CIRCUIT BREAKER BOXES THAT ARE MISSING CIRCUIT BREAKERS: GALLEY; GENERATOR ROOM; AND SECOND DECK STOREROOM.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Fire Fighting
Issued 10 June 1988
Resolved
MOUNT FIRE AX SO THAT IT IS ACCESSIBLE.
Condition: Unknown
Due 10 June 1988
Resolved 10 June 1988
Electrical
Issued 12 June 1987
Resolved
PROVIDE REMOTE FUEL SHUTDOWNS FOR ALL 3 GENERATORS.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Construction/Loadline
Issued 12 June 1987
Resolved
LOWER BILGE SUCTIONS IN ALL COMPARTMENTS. -VFOD,U
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Construction/Loadline
Issued 12 June 1987
Resolved
VESSEL TO BE DRYDOCKED.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Lifesaving
Issued 12 June 1987
Resolved
STENCIL VESSEL NAME ON RING BUOYS.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Lifesaving
Issued 12 June 1987
Resolved
STENCIL VESSEL NAME AND CAPACITY ON BUOYANT APPARATUS.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Fire Fighting
Issued 12 June 1987
Resolved
HAVE FIXED PKP FIRE EXTINGUISHING SYSTEM SERVICED.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Navigation
Issued 12 June 1987
Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Documentation
Issued 12 June 1987
Resolved
RENEW FCC STATION LICENSE.
Condition: Unknown
Due 12 June 1987
Resolved 12 June 1987
Accommodation/Occupational Safety
Issued 13 November 1984
Resolved
ICE MACHINE DRAIN LINE IS IMPROPERLY FITTED THRU DECK TO SPACE BELOW USING RUBBER TUBE INSERTED INTO A PLASTIC DRAIN LINE
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984
Construction/Loadline
Issued 13 November 1984
Resolved
IN #6 COMPT PATCH PLASTIC BAIT LINE & INSTALL RUB PROTECTION P/S WHERE LINEIS TOUCHING FRAMING. APPLY TEMP PATCH TO LEAK IN SAME LINE AT HULL PENETRA-TION PORT SIDE OF COMPT.
Condition: Unknown
Due 13 November 1984
Resolved 13 November 1984