Professional
The full record for this vessel
Behind this panel: 19 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
7 May 2026
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8367452
14 April 2026
Drydock Exam · Vessel Attendance · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8349546
9 May 2025
COI Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8087899
9 May 2024
Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873656
21 March 2024
Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7873815
21 April 2023
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7643118
10 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411236
20 April 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7408619
20 May 2021
Deficiency Check · Plan Review "T" Boat · Examination of Repairs · Damage Survey
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7202507
18 May 2021
Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7161302
18 March 2021
Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7148950
14 May 2020
COI Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6903985
7 May 2019
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6638505
19 March 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6638525
19 November 2018
Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6586721
3 May 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6375216
5 May 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105405
27 March 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6105336
12 May 2016
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5829911
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Renew the grabline and retroreflective tape on the vessel's ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 14 May 2024
Resolution: New life buoy placed on board.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 May 2024
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure and personnel injury. Where flexible nonmetallic hose is permitted for use, it must meet SAE J-1942 or USCG Type A1, A2, B1, or B2. Renew the identified fuel hose located on the starboard side of the fuel filter to the satisfaction of the reviewing Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 May 2024
Resolved 24 May 2024
Resolution: Fuel filter hose renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2022
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Repair throttle control head and complete a sea trail prior to carrying passengers to the satisfaction of the Coast Guard Marine Inspector (CGMI). 46 CFR 182.01-5
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2022
Resolution: See Activity Number 7411236
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 May 2022
Resolved
Portable extinguishers must be maintained in accordance with NFPA 10. 2005 fire extinguisher is more than 12 years old and must be replaced. Replace expired fire extinguisher prior to carrying passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 May 2022
Resolution: See Activity Number 7411236
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2022
Resolved
The owner or managing operator shall destroy, in the presence of the marine inspector, each lifejacket found defective and incapable of repair. Replace two adult life jackets, passenger count lowered to 19.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 17 May 2022
Resolution: See Activity Number 7411236
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2022
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Reduction gear dip stick missing and low on oil. 46 CFR 182.01-5. Replace reduction gear dip stick and ensure that oil level is full.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Reduction gear dip stick replaced and oil added to the correct level.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2022
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Shaft seal leaking sea water.
Repair shaft seal to ensure no sea water intrusion.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Shaft seal tightened.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 May 2022
Resolved
All machinery must be installed and maintained in such a manner as to afford adequate protection against machinery failure and personnel injury. Rudder post leaking sea water.
Repair rudder post to ensure no sea water intrusion.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 10 May 2022
Resolution: Rudder packing tightened
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021
Resolved
A vessel must carry one floating waterlight unless it is limited to daytime operation. Vessel's floating waterlight does not work.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 May 2021
Resolution: Replaced battery in the waterlight.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 May 2019
Resolved
Wire connector is broken off fireboy pressure switch only enabling the engine to run in overide possition. Repair fireboy system and retest to the satisfaction of the attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2019
Resolution: Vessel rep. repaired fireboy. Tested operation, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2019
Resolved
Number of lifejackets and type are not marked on stowage locations. Properly mark stowage location with number and type of lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 May 2019
Resolved
Location of remote fuel shutoff is not marked. Properly mark remote fuel shutoff.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 May 2019
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 May 2019
Resolved
Vessel does not have chartlet of area of operation as per local special consideration for launch policy. Provide chartlet for area of operation.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 May 2019
Resolution: Vessel rep. provided chartlet of area of operation.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 April 2019
Resolved
Stencil vessel's name on stern of vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 May 2019
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2016
Resolved
Eye wash and burn gel were expired. Provide new for first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 May 2016
Resolved 19 May 2016
Resolution: Provided new eye wash and burn gel.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 May 2016
Resolved
Provide fire servicing certificate for fire boy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 May 2016
Resolved 19 May 2016
Resolution: Provided new servicing report for fireboy system