MAURY USCG vessel records Sign in
← All vessels

BLACK PEARL

BLACK PEARL is a 1983 passenger vessel (inspected). The Coast Guard has recorded 92 inspections since 1984, most recently in April 2025, along with 190 deficiencies, 4 operational controls and 4 casualty investigations between 2010 and 2017.

Records from 1984 to 2025. Most recent: inspection, 16 April 2025.

Built
1983
Last inspected
16 April 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI4438
Flag
UNITED STATES
367698640
Maury page id
psix-55198

Inspections, by type

…with no type recorded15
Years with a record 39 calendar years (1984–2025)
The 92 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.8 ft × 17.0 ft × 6.6 ft
Registered tonnagegross 44 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHE WILLARD COMPANY(HULL) · COSTA MESA, CA, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN PEDRO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it44 - Regulatory (Subpart C or D), Gross Ton
30 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ6655MMSI 367698640 · active · compulsorily equipped · granted 3 December 2025, expires 3 December 2035
WDI4438MMSI 367698640 · cancelled · compulsorily equipped · granted 22 October 2015, cancelled 30 September 2025
WDD3096MMSI 368303000 · expired · compulsorily equipped · granted 24 June 2006, cancelled 27 August 2016
WDA4099MMSI 366805740 · expired · compulsorily equipped · granted 29 March 2001, cancelled 4 June 2011 · licensed under a name not among this hull’s recorded names (not shown)
WCL9116MMSI not assigned · expired · compulsorily equipped · granted 22 August 1994, cancelled 23 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 92

16 April 2025 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8116349
28 October 2024 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8025823
19 April 2024 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7907765
14 March 2024 Liferaft Servicing
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7886981
11 January 2024 Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7848867
4 January 2024 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7846580
21 December 2023 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7841020
16 August 2023 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7770199
10 May 2023 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7665450
6 December 2022 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7605277
13 September 2022 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7553249
12 May 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7433670
15 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7398505
8 November 2021 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7326768
29 April 2021 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7171401
7 December 2020 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7107745
18 August 2020 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7036135
10 February 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6907399
7 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6816903
15 May 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6677953
5 June 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6422604
6 March 2018 Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6364312
7 June 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6148754
12 February 2017 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6092681
14 July 2016 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5901696
28 March 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5824022
14 October 2015 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5730705
6 October 2015 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5737178
11 September 2015 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5749477
10 October 2014 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5002927
6 June 2012 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4315150
17 August 2011 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4125751
11 July 2011 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4062240
5 October 2010 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3773804
23 September 2008 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3326991
2 June 2008 Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3225591
25 January 2008 Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3155578
2 October 2007 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3054716
27 June 2006 COI Inspection · Deficiency Check · Simplified Stability Test
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2695235
26 May 2006 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2673454
18 May 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2652725
6 May 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2642198
23 March 2006 Plan Review "T" Boat · Simplified Stability Test · Annual Inspection · Hull Examination · Administrative Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2608113
10 March 2006 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2598999
9 March 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2601491
5 January 2005 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 2273057
9 December 2004 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2252844
4 March 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2018335
6 February 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001961
16 December 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1720510
12 December 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1713993
6 December 2001 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1407046
9 September 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 181335
26 February 2001 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1376480
3 August 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1381985
3 April 2000 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 659221
26 January 2000 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 814590
24 August 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375888
2 August 1999 Damage Survey · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1399158
24 July 1999 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 94072
24 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 167398
24 July 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 223580
19 March 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 777582
19 February 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1129848
3 September 1998 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 797091
11 August 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1378433
23 June 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1364771
3 July 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1443898
26 July 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428664
10 July 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 166305
18 June 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428665
12 September 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1190625
25 July 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1442289
1 July 1994 Hull Examination · Deficiency Check · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1420857
10 June 1993 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376990
31 July 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 944625
2 June 1992 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1267413
15 January 1992 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1264854
12 June 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1019902
13 June 1990 Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1226183
22 May 1990 Re-Inspection · Drydock Extension
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1233101
26 June 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1200904
5 June 1989 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 888766
4 November 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 890134
31 May 1988 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 886867
4 May 1987 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1321779
4 March 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1316309
13 June 1986 Deficiency Check · Credit Drydock · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1292388
30 August 1985 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 978193
17 May 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 981792
7 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284816
11 October 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1282278

Deficiency record · 190

11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 April 2025 Resolved
Each survival craft must be: (1) Secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter; Sea painter was connected to the tie down strap and would prevent the raft from inflating in the event of the vessel sinking. 46 CFR 180.130(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: Instructed crew on proper installation of sea painter to weak link.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 September 2022 Resolved
Each EPIRB must be tested monthly using the integrated test circuit and output indicator, to determine that it is operative. Vessel was not able to show correct interval of EPIRB tests over last year. vessel conducted satisfactory test of EPIRB in presence of attending Marine Inspector and was instructed on regulatory requirement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 September 2022
Resolution: See deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2022 Resolved
Each ring life buoy on a vessel must be approved in accordance with § 160.050 in sub-chapter Q of 46 CFR, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. 01 life buoy grab-line was wasted. Make grab line satisfactory and to manufacturer specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 27 June 2022
Resolution: Made grab line satisfactory to attending Marine Inspector..
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 December 2020 Resolved
Life rafts a required to be inspected annually. Unit is delaying this requiremnt until the end of 01/2021 IAW 46CFR185.730
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 January 2021
Resolution: Life raft was serviced.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 18 August 2020 Resolved
Have MMSI number programed into DSC radio.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 August 2020
Resolution: Received objectable evidence that MMSI number is programmed into radio.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 18 August 2020 Resolved
Prove proper operation of general alarm system. Vessel restricted from carrying overnight pax.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 August 2020
Resolution: Received objectable evidence of the general alarm system working properly. Overnight restriction removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019 Resolved
Undersized electrical wiring was used in a 120 VAC circuit in the pilot house. All power and lighting circuits must be installed with at least 14 AWG wire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel changed wire sizes to 14AWG.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2019 Resolved
Smoke detectors in passenger areas did not meet UL 217 approval. Provide smoke detectors that meet UL 217 approval.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 10 October 2019
Resolution: Verified that new smoke dedectors that meet UL 217 approval have been installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019 Resolved
Circuit breaker panel in pantry space not blanked off where circuit breakers are not installed. Provide blanks for all open slots in circuit breaker panels.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 20 November 2019
Resolution: Vessel installed blanks.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2019 Resolved
Voyage plans for overnight trips were said to be kept shore side at Virg’s Landing, but were not available upon request. Provide voyage plans to Coast Guard Inspectors. **705, Prior to carrying passenger on overnight voyages**
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2019
Resolved 16 October 2019
Resolution: Received Voyage plan.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 October 2019 Resolved
The emergency instructions were not specific to the vessel. Provide emergency plan that is specific to the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 16 October 2019
Resolution: Emergency instructions provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019 Resolved
Wiring in engine room was not properly supported. Provide metallic supports at least every 24” on all wire runs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel installed wire hangers.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 October 2019 Resolved
No station bill was available for voyages that consisted of 4 or more crewmembers. Provide a station bill for voyages that consist of 4 or more crewmembers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 16 October 2019
Resolution: Station bill provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 October 2019 Resolved
Plastic trash receptacles in enclosed accommodation areas need to be non-combustible material. Provide trash receptacles that are made from non-combustible material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 10 October 2019
Resolution: Verified that all new trash receptacles in enclosed accommodation areas were constructed of non-combustible material.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 October 2019 Resolved
No record of monthly maintenance being performed on portable fire extinguishers. Provide a log that contains recorded monthly maintenance being performed on portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel provided log and record of inspections.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019 Resolved
An ammeter was not installed in the battery charger circuit. Provide an ammeter in the battery charger circuit.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel installed ammeter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2019 Resolved
Replace grab line on life ring or replace life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Life ring replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019 Resolved
Provide 03 fire buckets or nozzle for wash down hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Nozzle provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2018 Resolved
Provide proper battery for life ring water light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2018
Resolved 8 June 2018
Resolution: Proper battery installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 7 June 2017 Resolved
Operator was unable to start PORT MDE due to the failure of the electric starter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2017
Resolved 9 June 2017
Resolution: Operator replaced electric starter.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 June 2017 Resolved
5 adult and 3 child (8 total) lifejackets found with inadequate / worn retroreflective material.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Retroreflective material was replaced on the spot.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2017 Resolved
Inspector discovered that the vessels Safety Radiotelephony Certificate was expired.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Corrected on the spot. Vessel had new certificate issued that day.
Documentation › Logs/Records › Drug Test Records
Issued 14 July 2016 Resolved
Conduct pre-employment drug testing on vessel Master.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2016
Resolved 15 July 2016
Resolution: Corrected prior to issuing COI.
Documentation › Logs/Records › Drug Test Records
Issued 14 July 2016 Resolved
Enroll Master of vessel in the drug and alcohol testing random program.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2016
Resolved 15 July 2016
Resolution: Corrected prior to issuing COI.
Stability › Weathertight Integrity › General
Issued 28 March 2016 Resolved
Meke bulkhead between the lazarette and engine room watertight. Gaps exist around four wet exhausts (2 x generator & 2 MDE) where they penetrate the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 25 April 2016
Resolution: Watertight fittings installed around four wet exhausts.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 October 2015 Resolved
Complete a satisfactory USCG annual inspection, prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2015
Resolution: Completed Annual Inspection
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 10 October 2014 Resolved
Properly install painter to weak leak prior to carrying passengers.
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 24 October 2014
Communications › Radio Communications › EPIRB
Issued 10 October 2014 Resolved
Install new EPIRB and register with NOAA or install new battery in currently installed EPIRB prior to carrying passengers beyond 3nm from shore.
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 24 October 2014
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 October 2014 Resolved
Service all portable fire extinguishers and fixed fire fighting system prior to carrying passengers.
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 10 October 2014
Fire Fighting › Fire Bucket › Availability
Issued 10 October 2014 Resolved
Provide 3 fire buckets.
Action required: 705 - Other - as specified
Due 10 November 2014
Resolved 24 October 2014
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 10 October 2014 Resolved
Install emergency lighting in berthing prior to overnight trip.
Action required: 705 - Other - as specified
Due 10 October 2014
Resolved 24 October 2014
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 10 October 2014 Resolved
Install missing forward hatch dogs for proper closure.
Action required: 705 - Other - as specified
Due 10 November 2014
Resolved 24 October 2014
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 October 2014 Resolved
Properly mark stbd fuel shut-off valve.
Action required: 705 - Other - as specified
Due 10 November 2014
Resolved 24 October 2014
Navigation › Piloting/Steering › US Coast Pilot
Issued 10 October 2014 Resolved
Update Coast Pilot and Light List.
Action required: 705 - Other - as specified
Due 10 November 2014
Resolved 24 October 2014
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 10 October 2014 Resolved
Provide up-to-date log book with current safety drills for fire, MOB, and EPIRB testing.
Action required: 705 - Other - as specified
Due 10 November 2014
Resolved 24 October 2014
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 11 July 2011 Resolved
Reconfigure shore tie to meet the requirements of Subchapter T IAW 46 CFR 183.390..
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 6 June 2012
Resolution: Shore power reconfigured to meet 46 CFR 183.390
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 July 2011 Resolved
Ensure crewmembers receive Employee Assistance Training prior to assuming safety sensitive position. IAW 46 CFR 16.401
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2011
Resolution: Employee Assistance Training provided for safety sensitive positions.
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 11 July 2011 Resolved
Make arrangements for reasonable cause testing IAW 46 CFR 16.250, 33 CFR 95.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2011
Resolution: Contacted US Health Works in Long Beach and established reasonable cause testing.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 11 July 2011 Resolved
Make arrangements for serious marine incident post-casualty chemical testing IAW 46 CFR 4.06 and 46 CFR 16.240.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2011
Resolution: Contacted US Health Works in Long Beach and set up post-casualty chemical testing.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 11 July 2011 Resolved
Provide a minimum of four unexpired alcohol testing devices IAW 46 CFR 4.06-3. Vessel restricted to no more than a 2 hour voyage until alcohol testing devices are onboard.
Action required: 705 - Other - as specified
Due 18 August 2011
Resolved 15 July 2011
Resolution: Provided 04 new, unexpired alcohol testing devices.
Fire Fighting › Fire Bucket › Quantity
Issued 11 July 2011 Resolved
Provide at least three 2.5 gallon buckets, with an attached lanyard, with the words "FIRE BUCKET" stenciled in a contrasting color on each bucket IAW 46 CFR 181.610.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2011
Resolution: Provided 03 five gallon fire buckets with lanyard, labled "fire bucket", with holes drilled to allow for 2.5 gallon capacity.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 July 2011 Resolved
Remove expired rubbing alcohol in first aid kit IAW 46 CFR 184.710 and 46 CFR 160.054-4
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 15 July 2011
Resolution: Expired rubbing alcohol removed from vessel.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 11 July 2011 Resolved
Provide bracket and mount required fire extinguisher in galley accomodation space in accordance with the manufacturer's instructions IAW 46 CFR 181.520 and 46 CFR 181.120.
Action required: 705 - Other - as specified
Resolved 15 July 2011
Resolution: Bracket and fire extinguisher mounted IAW 46 CFR 1881.520 and 1881.120 in galley.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 11 July 2011 Resolved
Install B-II fire extinguisher outside exit of machinery space IAW 46 CFR 181.500 and 46 CFR 181.520.
Due 11 August 2011
Resolved 15 July 2011
Resolution: Fire Extinguisher installed outside of machinery space.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 11 July 2011 Resolved
Provide Inflatable Buoyant Apparatus with current servicing report IAW 46 CFR 180.200 and 46 CFR 180.200(c). Vessel restricted to no more than 1 mile from shore until IBA is onboard.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 15 July 2011
Resolution: Provided IBA with current servicing report. (Returned from being serviced)
Engineering › Bilge Water Management System › Manifold
Issued 11 July 2011 Resolved
Demonstrate proper operation of bilge suction for each watertight compartment IAW 46 CFR 182.510 and 46 CFR 182.520.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2011
Resolution: Bilge suction satisfactorily tested in all compartments.
Pollution Prevention/Response › Prevention Equipment › Portable Containment
Issued 11 July 2011 Resolved
Store spare lube oil, hydraulic fluid in no more than 1 gallon containers, not to exceed 5 gallons in machinery space. Store spare diesel fuel in a suitable leak-proof container. IAW 46 CFR 176.800 and 46 CFR 176.25-50 Old T.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2011
Resolution: Spare lube oil, hydraulic fluid, and diesel fuel removed from machinery space.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 11 July 2011 Resolved
Replace battery in ring life buoy waterlight in accordance with manufacturer's instructions IAW 46 CFR 180.70 and 46 CFR 160.050.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 15 July 2011
Resolution: Battery replaced and dated in ring life buoy.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 11 July 2011 Resolved
Post a durable placard next to all radiotelephone installations with the emergency broadcast instructions and information specific to the vessel IAW 46 CFR 184.506 and 46 CFR 184.520.
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 15 July 2011
Resolution: Emergency broadcast placard posted under plastic protection next to radiotelephone installations.
Personnel › Training › Familiarization Training
Issued 11 July 2011 Resolved
Ensure crew training conducted upon employment, prior to getting underway for the first time and at least every three months. Provide a training log to include the dates of training and a general description of the training topics.
Action required: 705 - Other - as specified
Due 11 October 2011
Resolved 15 July 2011
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 July 2011 Resolved
Ensure crew members are familiar with their emergency duties for abandon ship, man overboard and fire fighting by conducting drills. Each drill must be conducted as if there were an actual emergency. All drills shall be logged and include date of drill and general description of the drill scenario.
Action required: 705 - Other - as specified
Due 11 October 2011
Resolved 15 July 2011
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 11 July 2011 Resolved
Maintain monthly EPIRB testing log IAW 46 CFR 185.728
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2011
Resolved 5 August 2011
Resolution: O/O provided binder with monthly checks to include monthly EPIRB checks.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 11 July 2011 Resolved
Provide Substance Abuse Professional (SAP) name and contact information IAW 46 CFR 16.401
Action required: 705 - Other - as specified
Due 11 August 2011
Resolved 15 July 2011
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 July 2011 Resolved
Complete an inspection for renewal of the Certificate of Inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2011
Resolved 15 July 2011
Resolution: Inspection Completed with 03 deficiencies remaining.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 5 October 2010 Resolved
Provide updated charts and pubs as per 46 CFR 184.420
Condition: Invalid
Due 17 November 2010
Resolved 14 January 2011
Resolution: Provided updated charts and pubs.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 October 2010 Resolved
Provide annual fire extinguisher service
Condition: Improper/Lack of Maintenance
Due 17 November 2010
Resolved 14 January 2011
Resolution: Had all fire extinguishers serviced.
Fire Fighting › Remote Fuel Shutoff › General
Issued 5 October 2010 Resolved
Label emergency fuel cutoff valves as per 46 CFR 185.608
Condition: Improper/Lack of Maintenance
Due 17 November 2010
Resolved 14 January 2011
Resolution: Labeled emergency fuel fuel cutoff valves.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 October 2010 Resolved
Move fireboy controller from eng room as per manufactures instructions.
Condition: Improper Installation
Due 17 November 2010
Resolved 14 January 2011
Resolution: Removed fireboy controller from engine room and installed per manufactures instructions. Conducted operational test, test sat.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 23 September 2008 Resolved
Provide MIS report and renew Alcohol swabs
Action required: 705 - Other - as specified
Resolved 23 September 2008
Resolution: MIS report was provided and swabs were renewed
Fire Fighting › Grease Extraction Hood › General
Issued 23 September 2008 Resolved
Provided plans for hood replacement, vsl has to 28 Feb 2009 to comply
Action required: 705 - Other - as specified
Resolved 23 February 2009
Resolution: Galley hood now complies with our CID policy
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 23 September 2008 Resolved
Replace four child life jackets
Action required: 705 - Other - as specified
Resolved 23 September 2008
Resolution: Life jackets have been replaced
Engineering › Electric Propulsion System › Wiring
Issued 23 September 2008 Resolved
Repair 12 volt MDE electrical box, box will not close
Action required: 705 - Other - as specified
Resolved 23 September 2008
Resolution: Box has ben repaired
Documentation › Logs/Records › Drug Test Records
Issued 2 October 2007 Resolved
Provide an annual drug report.
Condition: Improper/Lack of Maintenance
Due 22 October 2007
Resolved 4 October 2007
Operations/Management › Drills/Instruction › Fire
Issued 2 October 2007 Resolved
Log fire and man overboard drill.
Condition: Improper/Lack of Maintenance
Due 22 October 2007
Resolved 1 November 2007
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 2 October 2007 Resolved
Tape new reflective tape for 13 lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 October 2007
Resolved 1 November 2007
Lifesaving › Lifebuoys › Serviceable
Issued 2 October 2007 Resolved
Provide a new ring buoy due to rotted lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2007
Fire Fighting › Fire Bucket › Quantity
Issued 2 October 2007 Resolved
Provide 3 fire buckets.
Condition: Placed in Improper Service
Due 22 October 2007
Resolved 1 November 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 2 October 2007 Resolved
Update coast pilot and light list.
Condition: Improper/Lack of Maintenance
Due 22 October 2007
Resolved 4 October 2007
Navigation › Piloting/Steering › Marine Charts
Issued 2 October 2007 Resolved
Provide chart for SD harbor and area where boat operate.
Condition: Improper/Lack of Maintenance
Due 22 October 2007
Resolved 4 October 2007
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 2 October 2007 Resolved
Complies with CID policy #20 for galley hood.
Condition: Improper Installation
Due 22 October 2007
Resolved 7 October 2009
Resolution: Galley hood meets CID policy #20.
Lifesaving › Inflatable Liferafts › Boarding Ramp/Ladder
Issued 2 October 2007 Resolved
Provide a sturdy embarkation ladder
Condition: Placed in Improper Service
Due 22 October 2007
Resolved 1 November 2007
Engineering › Fuel Oil Service System › Valve
Issued 10 March 2006 Resolved
Demonstrate proper operation of all emergency fuel shut-off valves IAW 46CFR 182.455. Not deficient, just not demonstrated as of yet. Strange (top of tank) configuration which needs operational testing, then maybe a special note
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Engineering › Bilge Water Management System › Piping
Issued 10 March 2006 Resolved
Remove PVC and provide bilge piping IAW 46 CFR 182.70. In engineroom, system had been pieced together with several temporary flexible hose repairs and PVC segments. Other than engineroom PVC may be accepted (with close inspection) if original under CID memo 13-93.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Resolution: O/OP has completely renovated the bilge piping system with copper pipe and new manifold.
Communications › Alarms/Indicators › Bilge Alarm
Issued 10 March 2006 Resolved
Repair bilge alarms IAW 46 CFR 182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 March 2006 Resolved
Fish hold: Remove combustibles from vicinity of engine exhaust IAW 46 CFR 177.405.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Operations/Management › Drills/Instruction › Not Conducted
Issued 10 March 2006 Resolved
Demonstrate satisfactory operation of all machinery and conduct drills for inspection.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 27 June 2007
Resolution: Issued COI, drills SAT
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 10 March 2006 Resolved
Provide drug testing program IAW 46 CFR part 16
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Communications › Alarms/Indicators › Fire Alarm
Issued 10 March 2006 Resolved
Provide smoke detectors (ceiling of both port & stbd berthing areas) IAW 46 CFR 181.400. The one, small detector installed a foot down from the ceiling, is not sufficient. In my opinion these are TWO berthing areas.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Fire Fighting › Means of Escape › Emergency Lighting
Issued 10 March 2006 Resolved
Provide better visibility of berthing area emergency escape IAW 46 CFR 183.432. During emergency lighting conditions, the escape route is not illuminated nor visible at all, even from close up.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Accommodation/Occupational Safety › Ventilation › General
Issued 10 March 2006 Resolved
Make repairs to all berthing ventilation IAW 46 CFR 177.600. Port suction was too dirty to move any air. Neither of the stbd fans even worked. Electrical problem?
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 10 March 2006 Resolved
Remove chemicals and combustibles from berthing rack storage cubicles 46 CFR 177.405. (i.e.: paint & over-accumulation of papers & plastics)
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 March 2006 Resolved
Repair embarkation door 46 CFR 177.900. Port side embarkation door at rail coming apart at the hinges.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Panelboard
Issued 10 March 2006 Resolved
Provide appropriate cover and dripshield to 12 VDC distribution panel 46CFR 183.330.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 March 2006 Resolved
Provide overcurrent protection to all 12 VDC electrical circuits IAW 46 CFR 183.380
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Conductor
Issued 10 March 2006 Resolved
Repair burnt electrical circuits in crew berthing IAW 46 CFR part 183
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 10 March 2006 Resolved
Repair shower drain pump as original. Tank was overflowing into bilge, then pumping overboard, instead of being sent to sewage tank.
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Resolution: Shower in berthing area has been taken out of service and will no longer be used as a shower. Drain capped. Showers have now been added to upper deck heads.
Fire Fighting › Grease Extraction Hood › General
Issued 10 March 2006 Resolved
The galley griddle is not to be used prior to approved installation of Grease Extraction Hood, IAW 46 CFR 181.400, consider also 46 CFR 177.410 (structural fire protection), requirement previously issued January 5, 2005 by MSD Santa Barbara. I fully explained the provisions of the exemption, if he chooses to apply. No cooking with passengers until corrected.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 25 May 2006
Resolution: Waiver granted to vessel, during dry dock, to continue using the currently installed hood system but to provide w/i 12 months a proposal for a new system that meets all NFC/NFPA standards.
Communications › Radio Communications › EPIRB
Issued 10 March 2006 Resolved
Provide current EPIRB registration and hydrostatic release IAW 46 CFR 180.64. Vessel's route is reduced to no more than 3NM from mainland shore.
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Cable
Issued 10 March 2006 Resolved
Repair shorepower cable connection so as to prevent moisture intrusion. 46 CFR part 183
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 March 2006 Resolved
Repair all freshwater and sewage entrailments into upper structural portion of engineroom. Battery compartment was leaking into upper e/r structure (rotting wood) as well as the port macerator pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Resolution: Deck & battery compartment completely re-furbished.
Construction/Loadline › Structures › Machinery Space Opening
Issued 10 March 2006 Resolved
Provide detailed repair proposal for replacing rotting transverse and longitudinal underdeck structural members of engineroom, to include plans for all attachments, appurtenances, and interferences; and a long term maintenance plan to arrest microbe infestation and rot. A portion of this requirement was previously issued on January 5, 2005.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 10 March 2006 Resolved
Provide structurally safe ladder to engineroom, even if temporary. The upper left bolt not secured into the rotten wood. (This requirement to be corrected prior to any future CG inspection activity in engineroom).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2006 Resolved
Repair entire "Lube oil pump" circuit (beginning at ladder) to conform to 46 CFR part 183
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 10 March 2006 Resolved
Provide protection from moisture intrusion to all electrical components in upper engineroom IAW 46 CFR part 183. All are corroding from water splash.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Engineering › Bilge Water Management System › Pump
Issued 10 March 2006 Resolved
Remove ability for 12 VDC bilge pump in engineroom to automatically pump overboard. Pump switch energized and pumped oily water ovbd during inspection. Crew opened a breaker, but automatic switch needs to be disconnected properly.
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Resolution: Rule automatic bilge pumps have been removed. Vessel has a manifold system that works both electronically and off of the engine block.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 10 March 2006 Resolved
Permanently mount fuel transfer pump and filter on engineroom fwd bulkhead. (hanging by hose).
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Engineering › Fuel Oil Service System › Piping
Issued 10 March 2006 Resolved
Permanently repair fuel return pipe where temporary repair is located. Brittle epoxy-like substance applied on aft e/r bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 March 2006 Resolved
Install manufacturer's approved gasket on stbd raw water strainer. It had a full piece of emery cloth being used as a gasket. Port side leaked as well.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 March 2006 Resolved
Remove all PVC in all engine and exhaust cooling circuits IAW 46 CFR 182.710. (both main engines in two places)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2006 Resolved
Provide metallic wire/cabling supports throughout the vessel IAW 46 CFR 183.340 (Lazzarette, berthing rack storage cubicles, E/R exhaust fans, port side of E/R behind longitudinal underdeck beam, fish hold, etc).
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Accommodation/Occupational Safety › Potable Water System › General
Issued 10 March 2006 Resolved
Permanently mount fresh water pump, repair electrical circuit to meet 46 CFR part 183.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Lighting (service) › Lighting Fixture
Issued 10 March 2006 Resolved
Repair engineroom port/fwd light socket assembly IAW 46 CFR part 183
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 March 2006 Resolved
Repair bait tank motor lead wire so as to prevent moisture intrusion (stuffing tube) 46 CFR part 183
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Lifesaving › Lifefloat › Not on Board
Issued 10 March 2006 Resolved
Provide primary lifesaving appliances IAW 46 CFR part 180
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2006
Resolved 5 July 2006
Resolution: Vsl has a 50person IBA.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 March 2006 Resolved
Provide non-expired first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 10 March 2006 Resolved
Permanently mount galley griddle.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 25 May 2006
Resolution: One year waiver granted for continued use of current galley griddle.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 10 March 2006 Resolved
Provide dripshield above engineroom battery charger (port)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 March 2006 Resolved
Drain and dry battery box inside steps to galley, remove ability for water to accumulate. (Water accumulates from washing down the decks)
Action required: 705 - Other - as specified
Due 10 April 2006
Resolved 5 July 2006
Resolution: Deck completely re-furbished and batteries re-located. They are now properly stored in battery boxes beside of engines in engine room.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 9 March 2006 Resolved
Conduct required annual exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 March 2006
Resolved 10 March 2006
Resolution: Exam conducted 10MAR06.
Construction/Loadline › Structures › Machinery Space Opening
Issued 5 January 2005 Resolved
Provide repair/corrective action proposal for rotting section of transverse underdeck beam at forward end of engine room on overhead. Center section of transverse beam showing rot deterioration.
Action required: 705 - Other - as specified
Due 5 February 2005
Resolved 25 May 2006
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 5 January 2005 Resolved
Replace cutlass bearings for both port and stbd propulsion tailshafts.
Action required: 705 - Other - as specified
Due 5 February 2005
Resolved 25 May 2006
Engineering › Steering Gear System › Rudder Bearing
Issued 5 January 2005 Resolved
Replace both port and starboard rudder post bearings.
Action required: 705 - Other - as specified
Due 5 February 2005
Resolved 25 May 2006
Construction/Loadline › Structures › Machinery Space Opening
Issued 5 January 2005 Resolved
Arrest and treat furring on underdeck boards by starboard engine room vent in engine room.
Action required: 705 - Other - as specified
Due 5 February 2005
Resolved 25 May 2006
Fire Fighting › Grease Extraction Hood › General
Issued 5 January 2005 Resolved
Install grease extraction hood over galley griddle in accordance with 46 CFR 181.425.
Action required: 705 - Other - as specified
Due 5 February 2005
Resolved 25 May 2006
Resolution: Vessel granted one year waiver to submit plans and proposal for proper fire protection & UL710 Grease Extraction Hood in Galley.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 12 December 2002 Resolved
Generarator leaking exhaust fumes (worn rings) into engine room by way of crankcase ventiltor.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2003
Resolved 10 January 2003
Resolution: Replaced.
Accommodation/Occupational Safety › Ventilation
Issued 12 December 2002 Resolved
Power ventilation system in engine room venting generator exhaust fumes into fish hold and lazzarette.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 5 March 2004
Resolution: Inspected and corrected by a prior inspector. Verified power ventilation system.
Accommodation/Occupational Safety › Ventilation
Issued 12 December 2002 Resolved
Missing shutdown for power ventilation system on pilothouse.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 5 March 2004
Resolution: Per Old Subchapter T 46 CFR 182.15-45 -, vessel is not required to have power ventilation system shutdown on pilothouse.
Accommodation/Occupational Safety › Medical/First Aid
Issued 6 December 2001 Resolved
First aid kit incomplete, no scissors. Item corrected before inspection completed. LEGACY COMPONENT DESC: Medicine Chest
Due 6 December 2001
Resolved 6 December 2001
Communications › Radio Communications
Issued 6 December 2001 Resolved
Noted emergency broadcast placard was not posted by radios. Item corrected before inspection complete.
Due 6 December 2001
Resolved 6 December 2001
Construction/Loadline
Issued 26 February 2001 Resolved
Install new backing block on bilge pump sea valve.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Construction/Loadline
Issued 26 February 2001 Resolved
Repair as new watertight scuttle in way of forward peak compartment.
Condition: Unknown
Due 26 February 2001
Resolved 26 February 2001
Electrical
Issued 26 February 2001 Resolved
Renew all SO, SOJ, SOW and other SO style electrical cable throughout the vessel's AC electrical system using marine grade cable as required by 46 CFR 183.
Condition: Unknown
Due 26 February 2003
Resolved 16 December 2002
Resolution: All wire renewed.
Construction/Loadline
Issued 26 February 2001 Resolved
Install bilge suction line in forward peak compartment as required by 46 CFR 182.510.
Condition: Unknown
Due 26 March 2001
Resolved 19 April 2001
Construction/Loadline
Issued 3 August 2000 Resolved
INSTALL CHECK VALVES IN INDIVIDUAL BILGE SUCTION LINES FOR BILGE PUMPING SYSTEM IAW 46CFR182.510(c).
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Fire Fighting
Issued 3 August 2000 Resolved
CONDUCT ANNUAL SERVICING ON ENGINE ROOM FIXED FIRE SUPPRESSION SYSTEM.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Construction/Loadline
Issued 3 August 2000 Resolved
PROVE PROPER OPERATION OF BILGE PUMPING SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Construction/Loadline
Issued 24 August 1999 Resolved
Install audible alarms for installed high level bilge alarm system.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Engineering
Issued 24 August 1999 Resolved
Repair as new fuel leak on auxiliary generator fuel pump.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Electrical
Issued 24 August 1999 Resolved
Install protective cover over exposed light fixture above galley griddle.
Condition: Unknown
Due 24 August 1999
Resolved 24 August 1999
Accommodation/Occupational Safety
Issued 11 August 1998 Resolved
MARK EMERGENCY EXIT "EMERGENCY EXIT KEEP CLEAR" IN 2" LETTERS
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Navigation
Issued 11 August 1998 Resolved
UPDATE CHARTS W/CURRENT LOCAL NTM'S
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Lifesaving
Issued 11 August 1998 Resolved
INSTALL CROSSION RESISTANT CLIP ON LIFERING BUOY FLOATLIGHT LANYARD
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Engineering
Issued 11 August 1998 Resolved
PROPERLY LABEL EMERGENCY F/O STOP VALVES
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Lifesaving
Issued 11 August 1998 Resolved
REPAIR AS NEW LIGHT ON PORT LIFEFLOAT
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Lifesaving
Issued 11 August 1998 Resolved
INSTALL RETROREFLECTIVE TAPE ON LIFERING BUOYS
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Construction/Loadline
Issued 11 August 1998 Resolved
REPAIR AS NEW PORT RUDDER AND BME PACKING GLANDS
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Lifesaving
Issued 11 August 1998 Resolved
PROVIDE FLASHLIGHT AT ENGINROOM ACCESS
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Lifesaving
Issued 11 August 1998 Resolved
REPLACE REJECTED LIFEJACKETS
Condition: Unknown
Due 11 August 1998
Resolved 11 August 1998
Engineering
Issued 23 June 1998 Resolved
REPAIR AS NEW RUSTED F/O FITTING ON STBD AFT F/O TANK
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Construction/Loadline
Issued 23 June 1998 Resolved
RENEW GASKET FOR FORE PEAK SCUTTLE TO MAKE FITTING WATER TIGHT
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Navigation
Issued 23 June 1998 Resolved
REPAIR BROKEN WELD TO STEERING FOUNDATION
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Engineering
Issued 23 June 1998 Resolved
LABEL EMERGENCY F/O STOPS
Condition: Unknown
Due 2 July 1998
Resolved 2 July 1998
Engineering
Issued 3 July 1997 Resolved
Rework the caps for the fuel shut offs to unstick them.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Lifesaving
Issued 3 July 1997 Resolved
Provide two adult type one lifejacket prior to carring more than 50 person total.
Condition: Unknown
Due 6 August 1997
Resolved 6 August 1997
Lifesaving
Issued 10 June 1993 Resolved
PRIOR TO CARRYING PASSENGERS, CONDUCT FIRE AND MAN-OVERBOARD DRILLS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Engineering
Issued 10 June 1993 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE OPERATION OF MACHINERY, INCLUDING MAIN DIESEL ENGINES, AUXILIARY GENERATOR, AND ANCHOR WINDLASS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Construction/Loadline
Issued 10 June 1993 Resolved
PRIOR TO OPERATION OF VESSEL, CLEAN OIL FROM ENGINEROOM BILGE.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 10 June 1993 Resolved
PRIOR TO CARRYING PASSENGERS, APPLY RETRO-REFLECTIVE MATERIAL TO BUOYANT APPARATUS IN ACCORDANCE WITH 46 CFR 160.010-3(P).
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Accommodation/Occupational Safety
Issued 10 June 1993 Resolved
PRIOR TO CARRYING PASSENGERS, CLEAN SCREENS FOR VENTILATION IN BERTHING SPACES BELOW DECKS.
Condition: Unknown
Due 10 June 1993
Resolved 10 June 1993
Lifesaving
Issued 12 June 1991 Resolved
RENEW LIFE RING GRABLINES.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Engineering
Issued 12 June 1991 Resolved
PROVIDE AFTER FUEL TANK SPACE WITH VENTILATION IN ACCORDANCE WITH 46 CFR 182.20-50.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Deck/Cargo
Issued 12 June 1991 Resolved
PROPERLY MOUNT BAIT TANK SUPPLY PUMP.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Engineering
Issued 12 June 1991 Resolved
LABEL EMERGENCY FUEL SHUT-OFFS.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Accommodation/Occupational Safety
Issued 12 June 1991 Resolved
INSTALL FILTER ON GRILL EXHAUST FAN.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Accommodation/Occupational Safety
Issued 12 June 1991 Resolved
CLEAN GREASE FROM GRILL EXHAUST FAN AND DUCTING.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Lifesaving
Issued 12 June 1991 Resolved
RENEW LIFE FLOATS GRABLINES ON BOTH LIFE FLOATS.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Lifesaving
Issued 12 June 1991 Resolved
RENEW PADDLES ON STARBOARD LIFEFLOAT.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Electrical
Issued 12 June 1991 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGHOUT VESSEL IN ACCORDANCE WITH IEEE-45.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Accommodation/Occupational Safety
Issued 12 June 1991 Resolved
LABEL TOP SIDE OF EMERGENCY ESCAPE HATCH.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Construction/Loadline
Issued 12 June 1991 Resolved
MAKE COLLISION BULKHEAD WATERTIGHT.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Construction/Loadline
Issued 12 June 1991 Resolved
PROPERLY SECURE FUEL TRANSFER PUMP.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Engineering
Issued 12 June 1991 Resolved
REPAIR FUEL SYSTEM LEAKS/DRIPS.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Construction/Loadline
Issued 12 June 1991 Resolved
PLUG UNUSED SEA VALVE DISCHARGES.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Accommodation/Occupational Safety
Issued 12 June 1991 Resolved
RENEW MSD RAW WATER HOSES WITH USCG APPROVED HOSES.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Construction/Loadline
Issued 22 May 1990 Resolved
REPAIR ONE SECURING BOLT TO THE FLUSH DECK HATCH COVER FORWARD.
Condition: Unknown
Due 22 May 1990
Resolved 22 May 1990
Electrical
Issued 5 June 1989 Resolved
PROVIDE DRIP PAN OR SPRAY SHIELD TO THE SERVICE GENERATOR ELECTRICAL BOX TO WHERE THE BAIT TANK OVERBOARD DISCHARGE CONNECTION LINE IS LOCATED.
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Navigation
Issued 5 June 1989 Resolved
PROVIDE THREE BLACK BALLS DAY SHAPE FOR ANCHORING IN ACCORDANCE WITH THE NAVIGATION RULES.
Condition: Unknown
Due 5 June 1989
Resolved 5 June 1989
Construction/Loadline
Issued 4 May 1987 Resolved
PROVIDE CAPTURE CHAINS ON BOW FLUSH DECK HATCH
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Navigation
Issued 4 May 1987 Resolved
DEMONSTRATE VESSELS HORN
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Accommodation/Occupational Safety
Issued 4 May 1987 Resolved
PROVIDE METALLIC VENT PIPE TO ER BILGE.
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Navigation
Issued 4 May 1987 Resolved
POST STABILITY LETTER IN PILOT HOUSE
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Navigation
Issued 4 May 1987 Resolved
PROVE PROPER OPERATION OF EPIRB
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987 Resolved
STENCIL ADULT PFD STOWAGE
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Fire Fighting
Issued 4 May 1987 Resolved
PROVIDE SUCTION HOSE FOR HAND HELD FIRE PUMP
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 4 May 1987 Resolved
POST EMERGENCY CHECKOFF LIST
Condition: Unknown
Due 4 May 1987
Resolved 4 May 1987
Lifesaving
Issued 13 June 1986 Resolved
PROPERLY MOUNT LIFE FLOATS FOR FLOAT FREE OPERATION
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Lifesaving
Issued 13 June 1986 Resolved
RESTRING BOTH RINGBUOYS
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Navigation
Issued 13 June 1986 Resolved
PROVIDE COMPASS DEVIATION CARD
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Navigation
Issued 13 June 1986 Resolved
PROVIDE RECENT EDITION OF LIGHTLIST AND TIDE TABLES
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Engineering
Issued 13 June 1986 Resolved
PROVIDE 30X30 FLAME SCREEN ON ALL FUEL TANK VENTS
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Construction/Loadline
Issued 13 June 1986 Resolved
DEMONSTRATE PA SYSTEM
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Electrical
Issued 13 June 1986 Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTS
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Navigation
Issued 13 June 1986 Resolved
PROVIDE 8 INCH BELL
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Construction/Loadline
Issued 13 June 1986 Resolved
PROVIDE METHOD FOR PROPERLY SECURING ALL FLUSH DECK HATCHES
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Navigation
Issued 13 June 1986 Resolved
PROVE PROPER OPERATION OF STERN LIGHT
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Navigation
Issued 13 June 1986 Resolved
PROVIDE CURRENT EPIRB BATTERY
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Lifesaving
Issued 11 October 1984 Resolved
INSTALL FLOAT-FREE LINK ASSEMBLY FOR LIFE FLOATS.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Lifesaving
Issued 11 October 1984 Resolved
REPAIR LIGHTS ON 11 LIFE PRESERVERS.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Fire Fighting
Issued 11 October 1984 Resolved
PROVIDE ONE EACH B-II PORTABLE FIRE EXTINGUISHER FOR PASSENGER BERTHING AND CREWS BERTHING.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Engineering
Issued 11 October 1984 Resolved
PROVIDE GUARDS ON ROTATING BELTS ON FORWARD ENDS OF MAIN ENGINES.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984

Casualty record · 4

22 August 2010Routine · role: Involved in a Marine Casualty · activity 3832695
25 August 2012Routine · role: Involved in a Marine Casualty · activity 4423985
5 July 2015Routine · role: Involved in a Marine Casualty · activity 5175523
12 February 2017Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 6092681
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record