Records from 2010 to 2025. Most recent: inspection, 16 April 2025.
Inspection history · 26
16 April 2025
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8116349
28 October 2024
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8025823
19 April 2024
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7907765
14 March 2024
Liferaft Servicing
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7886981
11 January 2024
Administrative Inspection · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7848867
4 January 2024
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7846580
21 December 2023
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7841020
16 August 2023
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7770199
10 May 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7665450
6 December 2022
Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7605277
13 September 2022
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7553249
12 May 2022
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7433670
15 February 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7398505
8 November 2021
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7326768
29 April 2021
COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7171401
7 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7107745
18 August 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7036135
10 February 2020
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6907399
7 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6816903
15 May 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6677953
5 June 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6422604
6 March 2018
Internal Structural Exam · Administrative Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6364312
7 June 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6148754
12 February 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6092681
14 July 2016
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5901696
28 March 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5824022
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 16 April 2025
Resolved
Each survival craft must be:
(1) Secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter;
Sea painter was connected to the tie down strap and would prevent the raft from inflating in the event of the vessel sinking.
46 CFR 180.130(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 16 April 2025
Resolved 16 April 2025
Resolution: Instructed crew on proper installation of sea painter to weak link.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 September 2022
Resolved
Each EPIRB must be tested monthly using the
integrated test circuit and output indicator, to
determine that it is operative. Vessel was not able to
show correct interval of EPIRB tests over last year.
vessel conducted satisfactory test of EPIRB in presence
of attending Marine Inspector and was instructed on
regulatory requirement.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 13 September 2022
Resolution: See deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2022
Resolved
Each ring life buoy on a vessel must be approved in
accordance with § 160.050 in sub-chapter Q of 46 CFR, or
other standard specified by the Commandant, including,
but not limited to, approval series 160.150. 01 life
buoy grab-line was wasted. Make grab line satisfactory
and to manufacturer specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2022
Resolved 27 June 2022
Resolution: Made grab line satisfactory to attending Marine Inspector..
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 December 2020
Resolved
Life rafts a required to be inspected annually.
Unit is delaying this requiremnt until the end of 01/2021
IAW 46CFR185.730
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 January 2021
Resolution: Life raft was serviced.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 18 August 2020
Resolved
Have MMSI number programed into DSC radio.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 August 2020
Resolution: Received objectable evidence that MMSI number is programmed into radio.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 18 August 2020
Resolved
Prove proper operation of general alarm system.
Vessel restricted from carrying overnight pax.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 August 2020
Resolution: Received objectable evidence of the general alarm system working properly. Overnight restriction removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
Undersized electrical wiring was used in a 120 VAC circuit in the pilot house. All power and lighting circuits must be installed with at least 14 AWG wire.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel changed wire sizes to 14AWG.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 October 2019
Resolved
Smoke detectors in passenger areas did not meet UL 217 approval. Provide smoke detectors that meet UL 217 approval.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 10 October 2019
Resolution: Verified that new smoke dedectors that meet UL 217 approval have been installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
Circuit breaker panel in pantry space not blanked off where circuit breakers are not installed. Provide blanks for all open slots in circuit breaker panels.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 20 November 2019
Resolution: Vessel installed blanks.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 October 2019
Resolved
Voyage plans for overnight trips were said to be kept shore side at Virg’s Landing, but were not available upon request. Provide voyage plans to Coast Guard Inspectors.
**705, Prior to carrying passenger on overnight voyages**
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 October 2019
Resolved 16 October 2019
Resolution: Received Voyage plan.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 October 2019
Resolved
The emergency instructions were not specific to the vessel. Provide emergency plan that is specific to the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 16 October 2019
Resolution: Emergency instructions provided.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
Wiring in engine room was not properly supported. Provide metallic supports at least every 24” on all wire runs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel installed wire hangers.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 7 October 2019
Resolved
No station bill was available for voyages that consisted of 4 or more crewmembers. Provide a station bill for voyages that consist of 4 or more crewmembers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 16 October 2019
Resolution: Station bill provided.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 7 October 2019
Resolved
Plastic trash receptacles in enclosed accommodation areas need to be non-combustible material. Provide trash receptacles that are made from non-combustible material.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 October 2019
Resolved 10 October 2019
Resolution: Verified that all new trash receptacles in enclosed accommodation areas were constructed of non-combustible material.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 October 2019
Resolved
No record of monthly maintenance being performed on portable fire extinguishers. Provide a log that contains recorded monthly maintenance being performed on portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel provided log and record of inspections.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 October 2019
Resolved
An ammeter was not installed in the battery charger circuit. Provide an ammeter in the battery charger circuit.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 November 2019
Resolved 20 November 2019
Resolution: Vessel installed ammeter.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 May 2019
Resolved
Replace grab line on life ring or replace life ring.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Life ring replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2019
Resolved
Provide 03 fire buckets or nozzle for wash down hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 11 June 2019
Resolution: Nozzle provided.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 June 2018
Resolved
Provide proper battery for life ring water light.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 July 2018
Resolved 8 June 2018
Resolution: Proper battery installed.
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 7 June 2017
Resolved
Operator was unable to start PORT MDE due to the failure of the electric starter.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2017
Resolved 9 June 2017
Resolution: Operator replaced electric starter.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 7 June 2017
Resolved
5 adult and 3 child (8 total) lifejackets found with inadequate / worn retroreflective material.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Retroreflective material was replaced on the spot.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 June 2017
Resolved
Inspector discovered that the vessels Safety Radiotelephony Certificate was expired.
Action required: 705 - Other - as specified
Due 7 June 2017
Resolved 7 June 2017
Resolution: Corrected on the spot. Vessel had new certificate issued that day.
Documentation › Logs/Records › Drug Test Records
Issued 14 July 2016
Resolved
Conduct pre-employment drug testing on vessel Master.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2016
Resolved 15 July 2016
Resolution: Corrected prior to issuing COI.
Documentation › Logs/Records › Drug Test Records
Issued 14 July 2016
Resolved
Enroll Master of vessel in the drug and alcohol testing random program.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2016
Resolved 15 July 2016
Resolution: Corrected prior to issuing COI.
Stability › Weathertight Integrity › General
Issued 28 March 2016
Resolved
Meke bulkhead between the lazarette and engine room watertight. Gaps exist around four wet exhausts (2 x generator & 2 MDE) where they penetrate the bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2016
Resolved 25 April 2016
Resolution: Watertight fittings installed around four wet exhausts.