MAURY USCG vessel records Sign in
← All vessels

NEWPORT

NEWPORT is a 1983 industrial vessel. The Coast Guard has recorded 168 inspections since 1985, most recently in July 2026, along with 182 deficiencies, 1 operational control and 6 casualty investigations between 2011 and 2026.

Records from 1985 to 2026. Most recent: inspection, 24 July 2026.

Built
1983
Last inspected
24 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8308616 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRC2930
Flag
UNITED STATES
366942880
Maury page id
psix-55203

Inspections, by type

…with no type recorded43
Years with a record 39 calendar years (1985–2026)
The 168 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)259.3 ft × 54.0 ft × 22.0 ft
Registered tonnagegross 2,519 / net 755
ITC dimensions (L × B × D)259.3 ft × 54.0 ft × 22.0 ft
ITC tonnagegross 2,519 / net 755
BuilderNICHOLS BROTHERS BOAT BUILDERS INC · FREELAND, WA, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 5 March 2026 · expires 30 April 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2519 - Convention (Subpart B), Gross Ton
755 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WRC2930MMSI 366942880 · active · compulsorily equipped · granted 7 November 2017, expires 23 January 2028
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 168

24 July 2026 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8445763
3 April 2026 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8341713
3 April 2026 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8372894
23 March 2026 Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8330300
6 January 2026 Drydock Exam · COI Inspection · Administrative Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8291014
16 August 2025 Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8211437
16 August 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8212494
15 April 2025 TPO Audit
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8121502
10 April 2025 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8110104
6 January 2025 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8059136
22 November 2024 Administrative Inspection · Examination of Repairs · Damage Survey · MARPOL Annex I Examination · Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 8038601
1 May 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7904948
22 April 2024 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7899515
18 March 2024 Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7881130
2 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7844190
1 January 2024 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 7844096
8 November 2023 In-Service Inspection · Examination of Repairs · Periodic Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7822168
10 July 2023 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7738503
4 July 2023 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7734086
4 July 2023 Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7735203
23 February 2023 MTSA Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7641117
13 September 2022 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7557891
22 June 2022 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7490320
23 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7437292
8 November 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7347219
17 September 2021 Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7314277
26 May 2021 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7207470
25 May 2021 Permit to Proceed
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7206218
30 April 2021 Permit to Proceed
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7186622
13 November 2020 COI Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7094964
3 November 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7090191
28 August 2020 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7044707
15 January 2020 Permit to Proceed · Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6890101
11 January 2020 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6887405
8 January 2020 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6884561
2 January 2020 Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6882230
19 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6876947
22 November 2019 Examination of Repairs · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6866500
11 September 2019 Damage Survey · In-Service Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6809396
20 August 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6790180
7 May 2019 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6678586
15 August 2018 Hull Examination · MARPOL Annex V Examination · MTSA Verification · MARPOL Annex I Examination · Internal Structural Exam · Administrative Inspection · MARPOL Annex VI Survey · MARPOL Annex IV Survey · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6513183
20 April 2018 Administrative Inspection · Deficiency Check · Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6397247
19 April 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6396224
12 April 2018 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6395456
2 March 2018 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6364905
28 February 2018 Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6363303
17 January 2018 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6338908
22 December 2017 MARPOL Annex VI Survey · MARPOL Annex IV Survey · MTSA/ISPS Verification · MARPOL Annex I Examination · MARPOL Annex V Examination · Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6328113
26 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6192030
13 June 2017 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6182285
18 April 2017 Damage Survey
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6127687
7 April 2017 Damage Survey · Examination of Repairs
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6119931
4 April 2017 Type not recorded
No type recorded · Sector North Carolina · USCG East District (CGD-E) · Activity 6139059
21 December 2016 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6060951
14 December 2016 Annual Inspection · Deficiency Check · MTSA/ISPS Verification · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 6050028
12 March 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5831880
8 October 2015 COI Inspection · Hull Examination · MTSA/ISPS Verification · Internal Structural Exam · Administrative Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5749306
26 August 2011 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4127456
18 January 2011 Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3928549
15 January 2011 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3928817
14 January 2011 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3928107
4 January 2011 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3920630
29 November 2010 Deficiency Check · Drydock Exam · COI Inspection · MARPOL Annex I Examination · Hull Examination · Examination of Repairs · Internal Structural Exam · MTSA/ISPS Verification · Administrative Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3900235
20 July 2009 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 3541740
24 November 2008 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3368383
15 September 2008 Hull Examination · Annual Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3325186
13 July 2007 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2993500
13 June 2006 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2678176
24 May 2006 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2657895
20 April 2006 COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2628191
18 January 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2568559
29 November 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2542467
28 October 2005 Drydock Extension
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2523994
1 August 2005 Examination of Repairs · Annual Inspection · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2447343
28 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2300633
27 July 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2146683
22 July 2004 MTSA/ISPS Verification · ISM Oversight · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2139525
22 July 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2145643
30 June 2004 Administrative Inspection
Administrative · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2116719
27 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2053940
21 July 2003 Hull Examination · MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1853260
17 November 2002 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1706645
21 May 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1642671
5 June 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070590
24 April 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413915
1 April 2001 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 60501
31 October 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389211
2 August 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451593
10 February 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 716335
4 February 2000 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 110035
30 June 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1103928
30 April 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381557
14 October 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 760231
13 October 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 801518
24 September 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 165522
24 September 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 206219
27 July 1998 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1413395
30 June 1998 Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1454597
9 March 1998 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 769811
3 March 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 716353
19 February 1998 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 206215
5 November 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1120058
4 November 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 163854
13 October 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 181457
22 April 1997 COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1091601
20 January 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 162353
15 January 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1099350
16 September 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264955
28 May 1996 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 875280
16 May 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1425742
7 December 1995 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1357373
26 April 1995 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420966
21 June 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1330383
10 June 1994 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1018718
2 June 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 716347
15 April 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 92174
28 January 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858903
2 December 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 849074
11 November 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 173382
29 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 716341
27 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 55815
27 October 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 148545
7 September 1993 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 846607
20 August 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 845157
13 August 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1158164
20 July 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 843152
18 July 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 485536
20 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 359197
20 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 513256
4 April 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 464137
30 March 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144589
21 September 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 957804
5 September 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 539488
5 August 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1264910
14 July 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952845
2 July 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1455015
12 May 1992 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 948764
19 March 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012017
27 February 1992 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262648
24 January 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 952604
14 January 1992 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1263426
19 November 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246519
24 October 1991 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1244362
27 July 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246116
4 March 1991 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 927328
10 July 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1242652
6 July 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 925549
13 March 1990 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 915404
16 February 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1231976
7 November 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1027230
2 November 1989 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1003370
1 November 1989 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976206
24 August 1989 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1344740
28 July 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1197258
13 June 1989 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 897214
5 June 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1204847
18 January 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1200630
20 October 1988 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1199038
19 July 1988 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1032741
8 October 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1012785
2 September 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1002335
13 July 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1007358
12 May 1987 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1333340
4 October 1986 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315587
29 September 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1303119
17 April 1986 Credit Drydock
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1307964
5 July 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 982955

Deficiency record · 182

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2026 Resolved
Electrical installations on vessels must ensure: (a) maintenance of services necessary for saftey under normal and emergency conditions. Starboard diesel generator had a failed solenoid, causing the generator to emergency shutdown. Vessel has replaced solenoid and reports no issues. Vessel must provide technician report attesting to satisfactory condition of starboard generator to the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2026
Resolved 27 July 2026
Resolution: TPO report attested to satisfactory condition of repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 3 April 2026 Resolved
Electric installations on vessels must ensure: (a)Maintenance of services necessary for safety under normal and emergency conditions. -46CFR111.01-1(a) Starboard ship service diesel generator actuator, stater and coil windings made contact while operating, causing generator to smoke requiring emergency shutdown. Vessel has ordered new generator replace entirety of starboard generator in kind. Vessel must provide technicians report attesting to satisfactory replacement and operation of new starboard ship service diesel generator to the Coast Guard.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2026
Resolved 4 April 2026
Resolution: Received Technician's report attesting to proper operation of newly installed generator.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 30 January 2026 Resolved
Where there are carried liferafts for which approval launching devices are provided, means for illuminating those liferafts and launching devices during the preparation for and the process of launching, and also for illuminating the water into which those liferafts are launched until the process of launching is completed. Embarkation area for liferaft on port bridge deck area had no light for illuminating as required.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 31 January 2026
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 January 2026 Resolved
Bulkheads of galleys, paint and lamp lockers, and emergency generator rooms shall be of "A" Class construction. Galley door did not meet "A" Class boundary due to gap at bottom of door.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 1 February 2026
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 30 January 2026 Resolved
All ships of 150 gross tonnage and upwards and passenger ships irrespective of size, shall, in addition to the req.'s of para. 2.1, be fitted with: .1 a spare magnetic compass. Vessel did not have a spare magnetic compass.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 January 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 January 2026 Resolved
Lifejackets shall be made to the satisfaction of the Administration which may include the increase in the number of lifejackets to be carried. Lifejackets are not SOLAS approved.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 30 January 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 January 2026 Resolved
In lieu of the 2.5 inch hose and hydrants specified in Table 95.10-5(a) on vessels over 1,500 gross tons, the hydrants in interior locations may have siamese connections for 1.5 inch hose. Vessel did not have siamese connections for 1.5 inch hoses.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 2 February 2026
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 30 January 2026 Resolved
Vertical ladders and deck scuttles shall not in general be considered satisfactory as one of the required means of escape. Escape catch inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 31 January 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 30 January 2026 Resolved
A sufficient number of lights throughout machinery spaces to permit the performance of essential operations and observations under emergency conditions and to facilitate restoration of service. Port engine room had inoperable emergency lighting.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 1 February 2026
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 30 January 2026 Resolved
Ships constructed before 1 July 2014 shall comply with the req.' of this parapraph not later than the first survey after 1 July 2018. Fireman outfits did not have two-way radios.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 1 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2026 Resolved
ll fuel pipes, pipe connections, and accessories must be readily accessible, protected against mechanical injury, and effectively secured against excessive movement and vibration by the use of soft nonferrous metal liners or straps. Fuel line fwd of hydraulic pump needs securing.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 1 February 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 30 January 2026 Resolved
Each cable installation must meet (1) Section 6, of IEEE 45.8-2016 (inc. by ref.). Where cables pass through watertight decks or bulkheads, a watertight penetrator or watertight stuffing tubes, capable of taking packing, should be employed. Stbd fwd house stuffing tube is not watertight.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 1 February 2026
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 30 January 2026 Resolved
No oil fuel tank shall be situated where spillage or leakage therefrom can constitute a hazard by falling on heated surfaces. Precautions shall be taken to prevent any oil that may escape under pressure from any pump, filter or heater from coming into contact with heated surfaces. Fuel injectors and fuel piping connections did not have SOLAS approved tape to contain spray or leakage from them.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 February 2026
Resolved 1 February 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 August 2025 Resolved
Electric installations on vessels must ensure:(1) Maintenance of service necessary for safety under normal and emergency conditions. Duty MI was notified by vessel that they experienced a repeat loss of power on the Port generator causing a blackout. Vessel was able to switch to Stbd generator and resume normal operations. Vessel is to have US Coast Guard Marine Inspectors on board to attest to the full working order of generator.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 19 August 2025
Resolved 21 August 2025
Resolution: Generator and breaker install satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 August 2025 Resolved
Electric installations on vessels must ensure:(1) Maintenance of services necessary for safety under normal and emergency conditions. Duty MI was notified vessel experienced a loss of power on the Port generator causing a blackout. Vessel was able to switch to stbd generator and resume normal operations. Vessel to provide technician report attesting to satisfactory operation of port generator prior to any further movement, to Sector New Orleans DMI. 46 CFR 111.01-11(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2025
Resolved 17 August 2025
Resolution: MI attended repair check for port generator/breaker. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 10 April 2025 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel is conducting emergency drydock to repair an integral keel cooler that is leaking into the vessel through the hull material. Provide a repair proposal and UT report for the areas to be cropped and renewed. Effect final weld repair to the satisfaction of the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2025
Resolution: Vessel conducted in house UT shot report, cut back to good metal, and completed full weld repair.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 July 2023 Resolved
Dredging equipment pucntured hole in vessel's #5 void. Void space now has free communication with the sea. Vessel is required to get temp repairs with a PTP to drydock or enact permanent repairs before operation.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 6 July 2023
Resolved 13 July 2023
Resolution: Repairs completed to the satisfactory of the CG.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 22 June 2022 Resolved
No repairs or alterations affecting the safety of the vessel with regards to the hull, machinery, or equipment, shall be made without the knowledge of the Officer in Charge, Marine Inspection. Vessel made repairs to the headlong at tanks 7 Port and 7 Stbd.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 30 June 2022
Resolution: Vessel made repairs to the headlong to the satisfaction of the Coast Guard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021 Resolved
If a defect is found that may affect the safety of a pressure vessel, it shall be hydrostatically tested at a pressure of 1.5 times the maximum allowable working pressure. Substantial rust was found on the side of the air receiver located in the "Puzzle Palace" space. The maximum allowable working pressure (MAWP) is also unknown because the data plate on the pressure was also ineligible. Provide U-1A form for the pressure vessel and hydrostatically test the vessel to 1.5 times the MAWP listed on the air receiver or replace air receiver that meets the requirements of 46 CFR 54.01-5.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Wasted air receiver was replaced with new ASME stamped air receiver.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2021 Resolved
Suitable means shall be provided for priming centrifigual bilge pumps which are not of the self priming type. Bilge pump in port machinery void is not self priming.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Installed new bilge pump. Witnessed bilge pump draw suction.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2021 Resolved
Vessel shall be provided with satisfactory bilge pumping plant capable of pumping and draining any water tight compartment. Bilge system discharge piping in port machinery void has holes in it. Crop to good piping and renew.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Witnessed renewal of 15' of new bilge discharge piping.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 November 2021 Resolved
Nonmetallic fexible hose must be in accordance with SAE J1942 and hose end fittings must comply with SAE J1475. Fire main jumper hose located on the port side of main deck is cracked and dry rotted. Renew hose with hose meeting above requirements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 18 November 2021
Resolution: Installed new SAE J1942 hose
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 November 2021 Resolved
Exhaust pipe installations must conform to the requirements of ABYC P-1 and NFPA 302, section 23, part 1. Found exhaust leaks on inboard hydraulic unit engine. Engine also had oil soaked exhaust lagging. Repair exhaust leaks and replace damaged exhaust lagging.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 18 November 2021
Resolution: Renewed leaking exhaust bellows and installed new lagging.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 8 November 2021 Resolved
Each machinery space ventilation system must have two controls to stop the ventilation, one of which must be located outside the machinery space. Was unable to secure the stack ventilation fans in both the port and starboard engine rooms using the remote ventilation controls.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Installed new emergency shutdowns. Conducted satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021 Resolved
Pipe, tubing, joints and piping system components shall meet requirments of 46 CFR 56.50. Found two unauthorized patches on dredge service water system piping. Crop to good pipe and replace.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Witnessed instillation of two sections of piping. One 2' section and one 8' section.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 November 2021 Resolved
The inspection for certification shall include an inspection of the structure, pressure vessels, machinery and equipment to ensure that the vessel is in satisfactory condition and fit for service for which it is intended. Discovered heavy wastage on hopper slope plating and fwd bulkhead in the service water room, next to fwd ladder. Descale suspect areas and conduct guaging.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Inserted new steel plating in wasted areas. Witnessed dye pen testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2021 Resolved
No alterations affecting the safety of the vessel with regard to hull, machinery, or equipment shall be made without the knowledge of the OCMI. Found unauthorized, unapproved flexible hoses piped into both bilge pump suction piping. Flexible hose does not meet material requirements in 46 CFR part 56 nor is there a cutoff valve where the hose is attached to the bilge pump suction piping. Either remove alteration all together or replace hose with approved piping and add a cutoff valve at the bilge suction pipe.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Removed and capped unauthorized hoses.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 8 November 2021 Resolved
Vessels assigned a load line must meet special requirements as to strenght, closure of openings, etc. in accordance with 46 CFR Subchapter E. Found to two open penetrations in the stairwell serving the stbd machinery void.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 November 2021
Resolved 17 November 2021
Resolution: Threaded plugs were installed in penetrations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 November 2021 Resolved
Fluid power hoses and fittings shall meet the requirements of 46 CFR 56.60. Found leaking hydraulic hose in the fwd machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 17 November 2021
Resolution: Hose was replaced
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 November 2021 Resolved
Each liferaft must be arranged to permit it to drop into the water from the deck on which it is stowed. The arrangement of the liferaft on the port bridge deck is currently arranged that launching them from its stowed position would allow them the strike the deck below. Vessel shall make arrangements to allow the launching of the liferafts to drop into the water from the deck on which it is stowed within 30 days to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 17 November 2021
Resolution: Modified life raft arrangement.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 November 2021 Resolved
At least two lifebuoys, each with attached self-activating smoke signals, must be stowed where they can be quickly released from the navigation bridge and should, when released, fall directly into the water without striking any part of the vessel. The arrangement of the bridge lifebuoys are currently arranged that releasing them from its stowed position would allow them to strike the deck below. In addition, vessel shall ensure the lifebuoys meet requirements in LSA Code 2.1.1.7, weighing 4kg. Vessel shall make arrangements to allow the release of the bridge ring buoy to drop into the water from the deck on which it is stowed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 18 November 2021
Resolution: Installed pivoting launching arrangement to allow SOLAS Lifebuoys to free fall directly into water.
11 - Life Saving Appliances › N/A - No Subsystem › Anti-exposure suits
Issued 8 November 2021 Resolved
Each immersion suit or anti-exposure suit must be marked in such a way as to identify the person or vessel to which it belongs. Immersion suits onboard were not marked with the vessels name or person to which it belongs.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 18 November 2021
Resolution: Properly marked immersion suits.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2021 Resolved
Each portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least ½ inch high. Several portable fire extinguisher stations were not properly marked. Vessel shall adequately mark all portable extinguisher stations onboard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 December 2021
Resolved 18 November 2021
Resolution: Marked fire extinguisher and extinguisher locations.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 17 September 2021 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment shall be made without the knowledge of the officer in charge, marine inspections. Prior to loading or conducting dredging operations, submit a repair proposal and complete permanent repairs to teh port aft void to the satisfaction of the cognizant OCMI.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 September 2021
Resolution: Crack was cut out and 02 new inserts were installed. Witnessed sat dye test of new inserts with no leaks noted.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 15 January 2020 Resolved
Multiple insets and floor frames damaged. Crop and renew and or gouge and reweld where possible.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 January 2020
Resolved 28 January 2020
Resolution: All new inserts tested to the satisfaction of the attending MI.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 2 January 2020 Resolved
After any survey, no change shall be made in the vessel's structure,equipment, arrangement, material or scantlings without prior specific approval of the assigning authority. Vessel must make permanent repairs to damage iwo ramwell and centerling bulkheads to crack in hull to satisfaction of attending USCG marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 January 2020
Resolved 28 January 2020
Resolution: This def was cleared by activity 6890101, all repairs made to the satisfaction of attending MI.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 December 2019 Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of this sub-chapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. The vessel operator reported a 1 inch by 3/32 inch fracture in the hull bottom plating, causing approx. a gallon per minute of sea water to enter the #4 void. Prior to the vessel's departure, the vessel operator shall submit a diver's report documenting the extent of the damage to the exterior of the hull causing the water intrusion and a repair proposal to the cognizant OCMI for approval.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 December 2019 Resolved
In general, compliance with the standards established by the American Bureau of Shipping, see subpart 90.35 of this sub-chapter, will be considered as satisfactory evidence of the structural efficiency of the vessel. The vessel operator reported a 1 inch by 3/32 inch fracture in the hull bottom plating, causing approx. a gallon per minute of sea water to enter the #4 void. The vessel has completed temp repairs consisting of an epoxy patch to a cracked weld on the external portion of the hull and a 6" x 6" doubler plate to the internal fracture. The vessel has 90 days to affect permanent repairs to the satisfaction of the cognizant OCMI.
Action required: 705 - Other - as specified
Due 20 March 2020
Resolved 28 January 2020
Resolution: This def was cleared by activity 6890101, all repairs made to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2018 Resolved
Stbd emergency fuel shutoff valve to diesel supply tank broken and needs to be operable before vessel departure.
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 27 November 2018
Resolved 16 November 2018
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2018 Resolved
Vessel was found to have openings where shore ties penetrated in the machinery space that was unable to be plugged which would allow CO2 to escape the space and fail to extinguish a fire in an emergency.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 13 November 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2018 Resolved
Exhaust leak found on port main engine.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 13 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 15 August 2018 Resolved
Vessel was unable to start rescue boat and complete drill.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 November 2018
Resolved 13 November 2018
Engineering › Non-conventional Propulsion/Steering › Gear Shaft Housing (z-drive)
Issued 19 April 2018 Resolved
While conducted discharge operations of dredge spoils crew observed a lud noise immitting from stbd z drive unit. immediately shut down.authroized transit as per transit plan to Bollinger shipyard Port Fouchon for repairs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 April 2018
Resolved 21 April 2018
Resolution: Affected Z-drive replaced with refurbished drive from company spares.
Construction/Loadline › Hull › Hull Plating
Issued 28 February 2018 Resolved
Vessel has a crack in hull IWO #7 Void from Harper
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2018
Resolved 3 March 2018
Resolution: Insert hull plate 24x12
Engineering › Thrusters › Seal
Issued 28 February 2018 Resolved
Stbd Z drive seal leaking Hyd Oil
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2018
Resolved 3 March 2018
Resolution: Replaced seal
Engineering › Lubricating Oil Service System › Hose
Issued 28 February 2018 Resolved
Fwd Hyd Hose for Hooper leaking Fluid at Ram
Action required: 17 - Rectify deficiencies prior to departure
Due 28 February 2018
Resolved 3 March 2018
Resolution: Replace fitting
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 28 February 2018 Resolved
Vessel to conduct ISM Audit on Company
Action required: 705 - Other - as specified
Due 28 March 2018
Resolved 28 March 2018
Resolution: Recieved Audit report
Engineering › Pressure Vessel › Relief Valve
Issued 22 December 2017 Resolved
Relif valves tags missing and no reports available to verify last time tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 30 January 2018
Resolution: Vessel provided certificate of pressure relief bench test from 3rd party contractor for 175psi, air receivers MAWP is 200psi
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 22 December 2017 Resolved
Missing lagging in Port engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: Ships crew replaced lagging on exhaust side of turbo
Electrical › Lighting (service) › Lighting Fixture
Issued 22 December 2017 Resolved
Puzzle palace light fixture is broken.
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: A new cover was put on old ficture, but was a 1/2" smaller than fixture. C/E showed [name withheld] lighting that was going in the space. MI believes the currant cover is adequate until new fixture is installed.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 December 2017 Resolved
Port Side engine room electrical box is missing cover.
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: New panel cover was mounted on junction box
Electrical › Electrical Distribution System (service) › Junction Box
Issued 22 December 2017 Resolved
Hydraulic room relay cover is broken
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: cover was replaced with new one.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 December 2017 Resolved
Wires though out all engineering spaces are missing the proper banding to support them.
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: New bandings were added to E/R port and STBD, work shop, on deck wiring runs and hydrolic room forward.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 December 2017 Resolved
Vessel is missing most of the required IMO markings as per IMO Res A760(18)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: New placards were mounted
Communications › Alarms/Indicators › General Alarm
Issued 22 December 2017 Resolved
Hydraulic room and BOSN locker are missing the proper labeling for GA.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: New labeling/stencils were put by alarms.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 22 December 2017 Resolved
Fire pump packing has exessive leakage
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 22 December 2017
Resolution: Repaired packing
Fire Fighting › Fixed CO2 Fire Extinguishing System › Piping
Issued 22 December 2017 Resolved
Hydraulic room CO2 system time delay bracket is not supporting the time delay bottle.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 22 January 2018
Resolved 17 January 2018
Resolution: Ships crew mounted time delay bottle with proper bracket.
Fire Fighting › Fire Pumps › Pressure
Issued 13 June 2017 Resolved
Vessel is required to have two operational fire pumps on board. Operator reports that one fire pump is working at reduced capacity and requires servicing. Vessel is permitted to operate with temporary setup of diesel driven Godwin CD-150M Dri-Prime centrifugal pump. Permanent repairs must be completed within 30 days to the satisfaction of the attending Coast Guard marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 July 2017
Resolved 20 July 2017
Resolution: RCVD satisfactory evidence of new installation and operation of the Fire pump.
Construction/Loadline › Hull › Hull Plating
Issued 7 April 2017 Resolved
Prior to conducting commercial operations make permanent repairs to the hull plate and associated framing IWO the inset in the #6 stbd void to the satisfaction of ABS and USCG.
Action required: 705 - Other - as specified
Resolved 18 April 2017
Resolution: Verified, with ABS, that proper repairs have been made.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 December 2016 Resolved
Vessel is to provide sufficient number of valid alcohol testing strips readily available on board.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 December 2016
Resolution: Vessel Master provided photo of test strips and receipt.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 December 2016 Resolved
Install machinery guards on ship service generators.
Due 14 January 2017
Resolved 21 December 2016
Resolution: Vessel Master provided photos of installed machinery guards on port and stbd generators sets and auxiliary machinery.
Engineering › Reduction Gearing/Clutches › Shaft
Issued 18 January 2011 Resolved
Repair/Replace broke componenets in the clutch, gear mechanism (top hat) on the port z-drive.
Action required: 705 - Other - as specified
Due 18 January 2011
Resolved 18 January 2011
Resolution: Gear mechanism (top hat) replaced & tested SAT.
Engineering › Fuel Oil Service System › Piping
Issued 29 November 2010 Resolved
Install hard piping to both MDEs to shorten the length of flexible fuel hoses to within 30" or less.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 4 January 2011
Resolution: Fuel piping was corrected to include 30" or less of flexible hoses.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 29 November 2010 Resolved
Provide a current compass deviation card in Pilothouse near mag compass.
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 4 January 2011
Resolution: Received a copy of the current compass deviation card.
Communications › Long Range Identification and Tracking (LRIT) › Software Package Update
Issued 29 November 2010 Resolved
Install LRIT on board vessel IAW SOLAS V/19-1, vsl restricted to domestic service only.
Action required: 705 - Other - as specified
Due 13 January 2011
Resolved 14 January 2011
Resolution: Received Conformance test report from vsl, scanned into documents.
Communications › Alarms/Indicators › Bilge Alarm
Issued 29 November 2010 Resolved
Install bilge alarms in the lower machinery spaces Port & Stbd, IAW Table 46 CFR 62.35-50.
Action required: 705 - Other - as specified
Due 13 March 2011
Resolved 3 March 2011
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 20 July 2009 Resolved
Prior to departure ensure that fire extinguishers are in the porperly assigned station.
Due 20 August 2009
Resolved 24 August 2009
Resolution: All fire extinguishers are in their properly assigned station.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 20 July 2009 Resolved
Prior to departure replace all whistles and ensure lifevest straps are not in the fastened, locked position.
Due 20 August 2009
Resolved 24 August 2009
Resolution: Proper whistles where placed on life vest and whistles with cork ball removed.
Pollution Prevention/Response › Response Equipment › Containers
Issued 20 July 2009 Resolved
Prior to departure ensure proper house keeping practices are being followed. Rags, wires, and solvents should be stowed in proper locations. (General Housekeeping).
Due 20 August 2009
Resolved 24 August 2009
Resolution: The engineering area of the vessel was prepared for inspection and the areas of house keeping problems were addressed, all sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 July 2009 Resolved
Prior to departure repair the stbd keel cooler.
Due 20 August 2009
Resolved 24 August 2009
Resolution: Stbd keel cooler repaired, all sat.
Fire Fighting › Emergency Fire Pumps › Location
Issued 20 July 2009 Resolved
Prior to departure repair and install both shipboard installed fire pumps.
Action required: 705 - Other - as specified
Due 20 August 2009
Resolved 24 August 2009
Resolution: New fire pumps installed tested and fire drill conducted, all sat.
Lifesaving › Launching Appliances › Davit
Issued 15 September 2008 Resolved
Conduct load test of rescue boat davit.
Due 6 November 2008
Resolved 24 November 2008
Navigation › Piloting/Steering › Compass Deviation Table
Issued 15 September 2008 Resolved
Provide updated compass deviation card.
Due 6 November 2008
Resolved 24 November 2008
Electrical › Electric Generation Source (service) › Generator
Issued 16 July 2007 Resolved
Prior to conducting dredging operations, prove proper operation of the stbd Ship's Service Diesel Generator, to include electrical generating capability and engine alarms/shut-downs.
Action required: 705 - Other - as specified
Resolved 17 July 2007
Resolution: New generator head, replaced in kind, was installed and satisfactorily tested. Generator prime mover overspeed trip was also satisfactorily tested.
Electrical › Electric Generation Source (service) › Generator
Issued 16 July 2007 Resolved
Prior to conducting dredging operations, prove proper operation of the port generator overspeed trip IAW 46 CFR 111.12-1(b).
Action required: 705 - Other - as specified
Resolved 17 July 2007
Resolution: Overspeed trip was satisfactorily tested.
Fire Fighting › Ventilation Systems › Ducts
Issued 16 July 2007 Resolved
Prior to conducting dredging operations, prove proper operation of Port Engine Room ventilation closures.
Action required: 705 - Other - as specified
Resolved 17 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2007 Resolved
Properly wire generator hot-starts for both generators (no plugs/properly hard wire).
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 16 July 2007
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 16 July 2007 Resolved
Prove proper operation of the Oily Water Separator. All oily waste is to be retained onboard and transferred to a reception facility. Oil Record Book is to reflect the same.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 19 July 2007
Resolution: OWS troubleshooting/testing completed by Green Marine based in Metarie, LA. OWS tetsed to be working IAW MIB.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 July 2007 Resolved
Provide metal banding every 24" for all wire runs/cableways. Wiring is to be supported by brackets, not other wiring.
Action required: 705 - Other - as specified
Due 16 August 2007
Resolved 16 July 2007
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 16 July 2007 Resolved
Submit revised Automation Test Procedures to Local OCMI for review and approval IAW 46 CFR 61.40.
Due 16 November 2007
Resolved 6 October 2008
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 April 2006 Resolved
Prove proper operation of the Oily Water Separator.
Due 20 May 2006
Resolved 24 May 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 April 2006 Resolved
Remove all temporary wiring in the Wheel House and install electrical outlets IAW 46 CRF Subchapter J
Due 20 May 2006
Resolved 24 May 2006
Communications › Alarms/Indicators › High Water Alarm
Issued 20 April 2006 Resolved
Prove proper operation on the Generators and Main Diesel Engines High Temp alarms.
Due 20 May 2006
Resolved 24 May 2006
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 20 April 2006 Resolved
Resubmit onboard automation procedures to reflect current installation.
Due 30 June 2006
Resolved 13 June 2006
Resolution: Copies of the approved automation test procedures and approval letters have been received by Sector New Orleans. These copies have been forwarded/routed to be filed in the locally maintained vessel files.
Communications › Radio Communications › Satellite Communications Capability
Issued 1 August 2005 Resolved
Provide yearly maintenance for GMDSS and provide shore based maintenance agreement.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 1 August 2005 Resolved
Demonstrate proper operation of fire detection system.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Engineering › Lubricating Oil Service System › Gauge
Issued 1 August 2005 Resolved
Demonstrate proper operation of port main engine and port Z drive oil pressure gauges.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (hydraulic)
Issued 1 August 2005 Resolved
Demonstrate proper operation of STBD maine engine and Z drive/starter.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Fire Fighting › Firemans Outfit › Quantity
Issued 1 August 2005 Resolved
Provide extra batteries for firemans outfit flashlight.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 1 August 2005 Resolved
Provide cover for overhead light in port engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Construction/Loadline › Structures › Door
Issued 1 August 2005 Resolved
Adjust all watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Lifesaving › Rescue Boat › Capacity
Issued 1 August 2005 Resolved
Demonstrate proper operation of rescue boat.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Fire Fighting › Fire Pumps › Gland Sealing
Issued 1 August 2005 Resolved
Tighten shaft packing fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 August 2005 Resolved
Properly wire rescue boat all around mast head light.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 1 August 2005 Resolved
Provide proof of Co2 loop hose pressure testing.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 August 2005 Resolved
Label circuit directory card for distibution panel 108.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 August 2005 Resolved
Label circuit directory card for distribution panel in hydraulic room.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 August 2005 Resolved
Repair general alarm lights in both port and starboard engine room spaces.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 August 2005 Resolved
Repair exhaust lagging on port main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Electrical › Electrical Distribution System (service) › Switch
Issued 1 August 2005 Resolved
Mount control box for lube oil switch on port main engine.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 1 August 2005 Resolved
Demonstrate proper operation of OWS.
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Engineering › Generator (propulsion/auxiliary-electric) › Receptacle
Issued 1 August 2005 Resolved
Install flame bowls on Racor fuel oil filters for port generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Fire Fighting › Structural Fire Protection - General › Superstructure Construction
Issued 1 August 2005 Resolved
Provide access to fire damper in way of starboard side stack.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 August 2005
Resolved 5 August 2005
Engineering › Compressed Air System (control) › Valve
Issued 1 August 2005 Resolved
Replace pressure gauge on air receiver in hydraulic space
Action required: 705 - Other - as specified
Due 8 August 2005
Resolved 5 August 2005
Engineering
Issued 24 April 2001 Resolved
INSTALL CONTENT METER ON OILY WATER SEPARATOR
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Lifesaving
Issued 24 April 2001 Resolved
INSTALL AND PROVE OPERATION OF EMBARKATION LIGHTS.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Engineering
Issued 24 April 2001 Resolved
PROVIDE AND INSTALL GUARD FOR PULLEYS ON STARBOARD SHIP'S SERVICE GENERATOR.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Electrical
Issued 24 April 2001 Resolved
PROPERLY SECURE PORT FLOOD LIGHT ON BRIDGE DECK.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Lifesaving
Issued 24 April 2001 Resolved
REPLACE CENTER CATWALK AS NEEDED.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Navigation
Issued 24 April 2001 Resolved
PROVIDE CURRENT COMPLASS DEVIAITON CARD.
Condition: Unknown
Due 24 May 2001
Resolved 4 May 2001
Electrical
Issued 24 April 2001 Resolved
REPACE BRACKETS FOR CONDUIT PIPE ON STARBARD SIDE OF MAIN DECK.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Electrical
Issued 24 April 2001 Resolved
REPLACE WIRE RUN CONDUIT PIPE PORT SIDE OF CENTER CATWALK.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Fire Fighting
Issued 24 April 2001 Resolved
REPLACE CO2 BOTTLE, MIDDLE BOTTLE, PORT ENGINE CO2 BANK. VESSEL TO ARRANGE ADDITIONAL FIRE FIGHTING MEASURES UNITL BOTTLE IS REPLACED.
Condition: Unknown
Due 25 April 2001
Resolved 25 April 2001
Engineering
Issued 24 April 2001 Resolved
REPLACE DETERIORATED FUEL LINE.
Condition: Unknown
Due 24 April 2001
Resolved 24 April 2001
Accommodation/Occupational Safety
Issued 31 October 2000 Resolved
03. STARBOARD FORWARD SUPERSTRUCTURE EXTERIOR LADDER TOO NARROW. COMPLY W/MINIMUM REQUIREMENTS OF 46 CFR 92.10-25.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Construction/Loadline
Issued 31 October 2000 Resolved
01.install bilge system in port hull in accordance with 46 cfr 56.50-50.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Accommodation/Occupational Safety
Issued 31 October 2000 Resolved
02. #3 PORT VOID (A.K.A. SERVICE WATER VOID) IS NON-COMPLIANT WITH THE FOLLOWING SITES a) 46 CFR 92.10 (b). (b) 92.15-15. (c) 56.50-96. PROVIDE PROOF THAT THIS SPACE HAS BEEN ACCEPTED AS A WORKSPACE.
Condition: Unknown
Due 30 June 2001
Resolved 21 May 2002
Fire Fighting
Issued 31 October 2000 Resolved
04. REPAIR AND TEST FIREMAIN SYSTEM TO THE SATISFACTION OF ATTENDING COAST GUARD MARINE INSPECTOR PRIOR TO SAILING.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Deck/Cargo
Issued 31 October 2000 Resolved
05. RENEW FLAPPER IN 26" CHECK VALVE IN STARBOARD #3 VOID.
Condition: Unknown
Due 30 November 2000
Resolved 21 May 2001
Lifesaving
Issued 30 April 1999 Resolved
PROVIDE SOLAS APPROVED RESCUE BOAT AND LAUNCHING DEVICE.
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Navigation
Issued 30 June 1998 Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Construction/Loadline
Issued 30 June 1998 Resolved
REPAIR AND PROVE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 30 June 1998 Resolved
PROVIDE RESCUE CRAFT RADAR TRANSPONDERS (2).
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Electrical
Issued 30 June 1998 Resolved
PROVIDE LABELS FOR ELECTRICAL PANELS IN PORTSIDE OF HYDRAULIC ROOM AND FORWARD END OF STBD E/R.
Condition: Unknown
Due 30 July 1998
Resolved 21 August 1998
Construction/Loadline
Issued 30 June 1998 Resolved
PROVIDE 15PPM OILY WATER SEPARATOR AND STANDARD DISCHARGE CONNECTION WITH OILY WASTE DISCHARGE PIPING.
Condition: Unknown
Due 30 June 1998
Resolved 30 June 1998
Construction/Loadline
Issued 30 June 1998 Resolved
LABEL THE STBD BILGE PUMP SELECTOR SWITCH.
Condition: Unknown
Due 30 July 1998
Resolved 21 August 1998
Electrical
Issued 30 June 1998 Resolved
REMOVE PORTABLE CORDS FROM AFT PART OF STBD E/R AND IN PORT VOID NEAR MSD.
Condition: Unknown
Due 30 July 1998
Resolved 21 August 1998
Lifesaving
Issued 15 January 1997 Resolved
PROVIDE 10 PERSON LIFERAFT ON PORT SIDE OF VSL.
Condition: Unknown
Due 29 January 1997
Resolved 30 January 1997
Electrical
Issued 16 May 1996 Resolved
PROPERLY SECURE WIRING BUNDLES:_x001C_ A) ON FORWARD MAINDECK_x001C_ B) OVERHEAD IN HYDRAULIC ENGINEROOM
Condition: Unknown
Due 11 August 1996
Resolved 11 August 1996
Fire Fighting
Issued 16 May 1996 Resolved
PROVIDE COMPLETE SERVICING REPORT FOR FIXED CO2 SYSTEM AND PORTABLES.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Lifesaving
Issued 16 May 1996 Resolved
CONDUCT FIRE DRILL WITH FULL CREW PRIOR TO SAILING
Condition: Unknown
Due 18 May 1996
Resolved 21 May 1996
Electrical
Issued 16 May 1996 Resolved
PROVIDE COVERS FOR OVERHEAD LIGHT FIXTURES IN REFRIGERATOR ROOM
Condition: Unknown
Due 11 August 1996
Resolved 11 August 1996
Construction/Loadline
Issued 16 May 1996 Resolved
COMPLETELY SEAL AFT BULKHEAD OF ENGINEROOMS (P/S) TO ENSURE AIRTIGHTNESS OFSPACES (CO2 PROTECTED).
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Engineering
Issued 16 May 1996 Resolved
REPLACE GAUGE ON AIR START FORWARD PRESSURE VESSEL (LOS-81-401).
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Electrical
Issued 16 May 1996 Resolved
PROPERLY SUPPORT WIRING IN BOTH ENGINEROOMS W/METAL CLASPS/CHAFING PROTECTION MATERIAL (IN PLACE OF PLASTIC WIRE TIES).
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Accommodation/Occupational Safety
Issued 16 May 1996 Resolved
PROVIDE COVERS FOR SUPPLY FAN IN STARBOARD ENGINEROOM.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Electrical
Issued 16 May 1996 Resolved
UPDATE ELECTRICAL PANEL INFO FOR PANEL P404 LOCATED ON PORT SIDE IN HYDRAULIC ENGINE ROOM.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Lifesaving
Issued 10 June 1994 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 July 1994
Resolved 21 June 1994
Construction/Loadline
Issued 7 September 1993 Resolved
PROVIDE COPIES OF SPECIFICATIONS FOR ALL METAL INSERTED DURING THIS DRYDOCK.
Condition: Unknown
Due 28 October 1993
Resolved 28 October 1993
Construction/Loadline
Issued 7 September 1993 Resolved
MAKE AVAILABLE FOR INSPECTION ALL SEA VALVES ON THE INBOARD SIDE OF THE HOPPER.
Condition: Unknown
Due 17 November 1993
Resolved 17 November 1993
Accommodation/Occupational Safety
Issued 20 July 1993 Resolved
PROVIDE CG APPROVAL # FOR MARINE SANITATION DEVICE.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Electrical
Issued 20 July 1993 Resolved
PROVIDE GUARDS FOR GLOBE LIGHTS: _x001C_ A) AFT OF PORT MACHINERY HOUSE_x001C_ B) ABOVE PHONE IN STBD MACHINERY HOUSE
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Electrical
Issued 20 July 1993 Resolved
PROVIDE METAL WIRE TIES FOR WIRE RUNS IN FORWARD MACHINERY SPACE.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Electrical
Issued 20 July 1993 Resolved
REPLACE PORT GENERATOR EXHAUST LAGGING.
Condition: Unknown
Due 20 July 1993
Resolved 20 July 1993
Accommodation/Occupational Safety
Issued 20 July 1993 Resolved
CLEAN AIR RECEIVERS LOS-81402 AND 681910 AND MAKE AVAILABLE FOR INTERNAL EXAMINATION BY A CG MARINE INSPECTOR.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Navigation
Issued 20 July 1993 Resolved
REPOSITION RUNNING LIGHTS TO BE IN ACCORDANCE WITH RULE 21 OF NAVIGATION RULES.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Fire Fighting
Issued 20 July 1993 Resolved
PROVIDE NEW CONTROL STATION DOORS FOR FORWARD ACTIVATION DOORS.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Fire Fighting
Issued 20 July 1993 Resolved
PROVIDE NEW DIRECTION PLACARDS FOR CO2 ACTIVATION STATIONS.
Condition: Unknown
Due 13 August 1993
Resolved 13 August 1993
Deck/Cargo
Issued 21 September 1992 Resolved
VSL DOES NOT HAVE INSTALLED OILY WATER SEPARATOR. PROVIDE AN OILY WATER SEPARATOR OR CHANGE ROUTE OF VESSEL.
Condition: Unknown
Due 21 September 1992
Resolved 21 September 1992
Documentation
Issued 2 July 1992 Resolved
PROVIDE A COPY OF A VALID CERTIFICATE OF FINANCIAL RESPONSIBILITY (COFR)._x001C_
Condition: Unknown
Due 14 July 1992
Resolved 14 July 1992
Fire Fighting
Issued 27 July 1991 Resolved
PROPERLY INSTALL ALL SUPPORTS FOR FIRE MAIN.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Documentation
Issued 27 July 1991 Resolved
SUBMIT REQUEST FOR WAIVER, CONCERNING IOPP CERTIFICATE.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Documentation
Issued 27 July 1991 Resolved
REVISE DRUG TESTING PROGRAM.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Fire Fighting
Issued 27 July 1991 Resolved
PROVIDE USCG APPROVED NOZZLE FOR FWD FIRE STATION.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Fire Fighting
Issued 27 July 1991 Resolved
COMPLETE INSTALLATION OF FWD FIRE STATION.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Fire Fighting
Issued 27 July 1991 Resolved
SUBMIT PLANS OF FIRE MAIN MODIFICATIONS TO U.S. COAST GUARD MARINE SAFETY CENTER.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Fire Fighting
Issued 27 July 1991 Resolved
HYDRO TEST NEW FIRE HOSE FOR FWD FIRE STATION.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Fire Fighting
Issued 27 July 1991 Resolved
SUBMIT UPDATED FIRE CONTROL PLAN TO MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 27 July 1991
Resolved 27 July 1991
Navigation
Issued 28 July 1989 Resolved
8- REPAIR RINGER ON SOUND POWERED TELEPHONE ON FORECASTLE.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Fire Fighting
Issued 28 July 1989 Resolved
9- HYDRO AIR BOTTLES FOR SELF CONTAINED BREATHING APPARATUS. ( 4 BOTTLES )
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Construction/Loadline
Issued 28 July 1989 Resolved
4- REPAIR/REPLACE WATER TIGHT DOORS ON AFT MACHINERY SPACES. INBOARD DOORS ON BOTH MACHINERY SPACES.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Engineering
Issued 28 July 1989 Resolved
5- HYDRO FUEL TRANSFER HOSE TO 150 PSI OR REPLACE HOSE.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Engineering
Issued 28 July 1989 Resolved
6- REPAIR/REPLACE TACHOMETER FOR STARBOARD GENERATOR.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Electrical
Issued 28 July 1989 Resolved
7- TEST OVERSPEED FOR STARBOARD GENERATOR.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Engineering
Issued 28 July 1989 Resolved
1- SUBMIT BILGE PIPING PLANS TO MARINE SAFETY CENTER FOR APPROVAL FOR THE PORT HULL. (46CFR 56.50-50)
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Engineering
Issued 28 July 1989 Resolved
2- INSTALL BILGE SYSTEM IN ACCORDANCE WITH APPROVED PLANS IN PORT HULL.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Accommodation/Occupational Safety
Issued 28 July 1989 Resolved
3- INSTALL VENT COVER ON FORWARD MACHINERY SPACE.
Condition: Unknown
Due 28 July 1989
Resolved 28 July 1989
Engineering
Issued 20 October 1988 Resolved
SUBMIT PROPOSAL FOR INSTALLATION OF KEEL COOLER ISOLATION VALVES, WHICH MEET 46 CFR 56.50.96.
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Construction/Loadline
Issued 20 October 1988 Resolved
CLEAR WORKLIST ITEMS 2 THROUGH 6 AND "B" THROUGH "F" ISSUED 17OCT88, FOR COMPLETION OF CREDIT INTERNAL STRUCTURAL EXAMINATION.
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Engineering
Issued 20 October 1988 Resolved
DRILL AND COTTER PIN KEEL COOLER MOUNTING BOLTS FOR FOUR KEEL COOLERS IN #3P AND #3S VOIDS.
Condition: Unknown
Due 20 October 1988
Resolved 20 October 1988
Fire Fighting
Issued 19 July 1988 Resolved
MAKE PERMANENT REPAIRS TO PORT FIRE PUMP DURING NEXT SCHEDULED DRY DOCKING OR YARD PERIOD, BUT NOT LATER THAN 30 APRIL 1989.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Fire Fighting
Issued 19 July 1988 Resolved
PROVIDE MSO PORTLAND, OREGON, WITH COPY OF CERTIFICATE OF SERVICE FOR ALL FIXED FIRE EXTINGUISING SYSTEMS ONBOARD.
Condition: Unknown
Due 19 July 1988
Resolved 19 July 1988
Documentation
Issued 13 July 1987 Resolved
PROVIDE TRIM & STABILITY BOOK WITH STABILITY LETTER.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Deck/Cargo
Issued 13 July 1987 Resolved
PROVIDE COAST GUARD APPROVED PLANS AND INSTALLATION OF BILGE SYSTEM FOR ALL VOID SPACES.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Navigation
Issued 13 July 1987 Resolved
REPAIR MARK AND PROVE OPERATION OF SOUND POWERED PHONE ON FOC'SLE.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Engineering
Issued 13 July 1987 Resolved
PROVIDE DETAILED OIL TRANSFER PROCEDURES WITH PROPERTY MARKED VALVES.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Engineering
Issued 13 July 1987 Resolved
REPLACE RELIEF VALVE ON MAIN CLUTCH AIR TANK AND TEST.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Documentation
Issued 13 July 1987 Resolved
PROVIDE COAST GUARD APPROVED AUTOMATION TEST PROCEDURE FOR MAIN DIESEL ENGINE.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Engineering
Issued 5 July 1985 Resolved
INSTALL OVERSPEED TRIPS ON THE PORT AND STARBOARD MAIN ENGINES.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Lifesaving
Issued 5 July 1985 Resolved
INSTALL AN APPROVED LINE THROWING GUN AND EQUIPMENT.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Electrical
Issued 5 July 1985 Resolved
REPAIR OR REPLACE THE OVERSPEED TRIPS ON NO. 1 AND NO. 2 S/S GENERATORS.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985
Fire Fighting
Issued 5 July 1985 Resolved
INSTALL VENT CLOSURES IN THE PORT AND STARBOARD ENGINE ROOMS AND THE HYDRAULIC PUMP ROOM.
Condition: Unknown
Due 5 July 1985
Resolved 5 July 1985

Casualty record · 6

15 January 2011Routine · role: Involved in a Marine Casualty · activity 3928817
13 April 2011Routine · role: Acknowledged Pollution Source · activity 3987006
4 April 2017Routine · role: Involved in a Marine Casualty · activity 6139059
4 July 2023Routine · role: Involved in a Marine Casualty · activity 7734086
16 August 2025Routine · role: Involved in a Marine Casualty · activity 8212494
3 April 2026Routine · role: Involved in a Marine Casualty · activity 8372894
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.