Records from 1986 to 2003. Most recent: inspection, 3 February 2003.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
3 February 2003
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1739133
29 January 2003
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1734054
14 August 2002
Simplified Stability Test · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1663561
15 March 2002
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1493813
21 March 2001
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1445791
18 April 2000
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1048555
23 March 2000
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 816693
24 March 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1115594
18 March 1998
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786950
5 May 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1115807
6 May 1996
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 875209
29 April 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1392218
26 May 1994
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1356666
12 May 1993
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1376976
11 September 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1256565
20 August 1992
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1261527
22 October 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 942116
16 August 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1251956
30 July 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 932923
14 June 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 903470
14 June 1991
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 907038
19 June 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1213547
16 May 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1221449
10 June 1989
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 892676
28 June 1988
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1035114
12 May 1987
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1003601
1 July 1986
Credit Drydock · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1299000
Documentation › Certificates/Documents
Issued 14 August 2002
Resolved
Provide valid vessel documentation or state registration prior to vessel operations. 46 CFR 67.7 & 67.9(c). LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Condition: Placed in Improper Service
Due 14 September 2002
Resolved 10 September 2002
Engineering › Fuel Oil Service System
Issued 14 August 2002
Resolved
Provide fire sleeves on all fuel hoses in engine room or renew with approved hose meeting SAE J-1942 and fittings meeting SAE J-1475. 46 CFR 182.720 LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Due 14 September 2002
Resolved 10 September 2002
Construction/Loadline
Issued 21 March 2001
Resolved
Make engine room bulkhead fume/vapor tight.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 21 March 2001
Resolved
Mark ring buoy with vessel's name.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 21 March 2001
Resolved
Provide audible alarm for fixed fire extinguishing system.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 21 March 2001
Resolved
lower fume detector to approx 10" above bilge bottom.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 23 March 2000
Resolved
PROVIDE VENT CLOSURES FOR CLAM SHELL ENGINE SPACE SCOOPS.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 23 March 2000
Resolved
PROVIDE SPACE FORWARD OF ENGINE ROOM WITH OPERABLE ELECTRIC SUBMERSIBLE BILGE PUMP.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 23 March 2000
Resolved
PROVIDE INDICATOR LIGHT FOR AUTO BILGE PUMP TO SHOW WHEN PUMP IS OPERATING IN AUTOMATIC MODE.
Condition: Unknown
Due 23 March 2000
Resolved 23 March 2000
Construction/Loadline
Issued 24 March 1999
Resolved
Make repairs: Vee/weld lower jet guard mount brackets.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Lifesaving
Issued 24 March 1999
Resolved
Provide a life jacket donning placard.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Lifesaving
Issued 24 March 1999
Resolved
Properly mark the life jacket stowage with quantity.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Unknown
Issued 24 March 1999
Resolved
Provide the following information concerning drug testing: Copy of consortium/third party agency contract, MIS report for 1998.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Documentation
Issued 24 March 1999
Resolved
Provide a copy of current state vessel registration._x001C_
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Documentation
Issued 24 March 1999
Resolved
Provide a copy of master's current license._x001C_ _x001C_
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Fire Fighting
Issued 24 March 1999
Resolved
Have annual service/6 year maintenance performed on the fixed fire extinguisher.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Fire Fighting
Issued 24 March 1999
Resolved
Provide annual service/6 year maintenance performed on the two portable extinguisher. Only 6 year on bottle dated 1992.
Condition: Unknown
Due 24 March 1999
Resolved 24 March 1999
Documentation
Issued 6 May 1996
Resolved
Provide evidence of compliance for drug testing in accordance with 46 CFR 16.
Condition: Unknown
Due 6 June 1996
Resolved 7 June 1996
Lifesaving
Issued 20 August 1992
Resolved
PROVIDE ONE (1) ADDITIONAL CHILD PFD. LIMITED TO ONE (1) CHILD UNTIL PROVIDED.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Engineering
Issued 20 August 1992
Resolved
MOVE FUEL TANK SHUT OFF VALVES TO THE FUEL TANK AND MAKE IT OPERABLE FROM OUTSIDE OF THE FUEL TANK COMPARTMENT.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 14 June 1991
Resolved
PROVIDE 9 ADDITIONAL ADULT AND 1 ADDITIONAL CHILD PFD FOR A TOTAL OF 24_x001C_ ADULT AND 3 CHILD PFDS. VESSEL IS LIMITED TO 15 ADULTS AND 2 CHILDREN_x001C_ UNTIL REQUIREMENT IS COMPLETE.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Engineering
Issued 14 June 1991
Resolved
DOUBLE CLAMP FUEL FILL HOSES ON BOTH FUEL TANKS.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Documentation
Issued 14 June 1991
Resolved
PROVIDE OIL POLLUTION PLACARD.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Engineering
Issued 14 June 1991
Resolved
PROVE SATISFACTORY OPERATION OF BOTH MAIN ENGINES.
Condition: Unknown
Due 14 June 1991
Resolved 14 June 1991
Engineering
Issued 16 May 1990
Resolved
PROVIDE RIGID NON-COMBUSTIBLE DUCTS FOR MECHANICAL EXHAUST.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Lifesaving
Issued 16 May 1990
Resolved
PROVIDE 7 ADDITIONAL PFD'S FOR A TOTAL OF 24. VESSEL IS LIMITED TO CARRYING 17 TOTAL PERSONS UNTIL REQUIREMENT IS COMPLETED.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Lifesaving
Issued 16 May 1990
Resolved
STENCIL VESSEL'S NAME ON RING BUOY.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Fire Fighting
Issued 16 May 1990
Resolved
MAKE HALON INDICATOR LIGHT ON CONSOLE OPERATIONAL.
Condition: Unknown
Due 16 May 1990
Resolved 16 May 1990
Lifesaving
Issued 12 May 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE 31 SQUARE INCHES OF RETROREFLECTIVE MATERIAL ON EACH SIDE OF ALL LIFE PRESERVERS (IN ACCORDANCE WITH 46 CFR 180.25-25).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Construction/Loadline
Issued 12 May 1987
Resolved
EFFECT REPAIRS TO FRACTURED UNDERDECK STIFFENERS (JUST FORWARD OF FISH HOLD).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
PROVIDE MEANS OF QUICK RELEASE FOR THE RING BUOY LINE.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 12 May 1987
Resolved
RENEW OR REPAIR FLOAT SWITCH FOR ENGINE ROOM BILGE PUMP.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Engineering
Issued 12 May 1987
Resolved
PROVIDE CHECK VALVES IN ALL BILGE DISCHARGE LINES (IN ACCORDANCE WITH 46 CFR 182.25-5(C)).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Construction/Loadline
Issued 12 May 1987
Resolved
EFFECT REPAIRS TO HOLE IN BOW (AT DECK LEVEL, ON PORT SIDE).
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Lifesaving
Issued 12 May 1987
Resolved
PRIOR TO CARRYING PASSENGERS FORE HIRE, RENEW LINES ON RING BUOY.
Condition: Unknown
Due 12 May 1987
Resolved 12 May 1987
Electrical
Issued 1 July 1986
Resolved
INTERLOCK IGNITION WITH POWER VENTILATION FOR MACHINERY/FUEL SPACE IN ACCORDANCE WITH 46 CODE OF FEDERAL REGULATIONS PART 182.15-45(D).
Condition: Unknown
Due 1 July 1986
Resolved 1 July 1986