Records from 1986 to 1997. Most recent: inspection, 5 May 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
5 May 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 782942
17 June 1996
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1086961
6 May 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1084455
25 April 1995
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1382951
29 June 1994
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1410983
21 July 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1254559
12 August 1990
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 923279
6 July 1990
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 907680
6 July 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 920653
28 June 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1222952
12 April 1990
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1229729
16 January 1990
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1242344
3 October 1989
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1320032
28 April 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1200355
13 May 1987
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1338630
28 August 1986
Credit Drydock · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1005206
Fire Fighting
Issued 5 May 1997
Resolved
HAVE PORTABLE B-I FIRE EXTINGUISHERS PROFESSIONALLY SERVICED.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 5 May 1997
Resolved
PROVIDE ONE ADDITIONAL B-I FIRE EXTINGUISHER ON BOARD.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 5 May 1997
Resolved
HAVE FIXED CO2 BOTTLE ANNUALLY SERVICED.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 May 1997
Resolved
HAVE DRIP PANS, FITTED WITH 30 X 30 MESH METALIC FLAME SCREENS, UNDER EACH FUEL FILTER.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 May 1997
Resolved
REPLACE MISSING STBD SIDE EXH VENT BLOWER.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 5 May 1997
Resolved
PRIOR TO RETURNING TO OPERATION, PROVIDE EVIDENCE OF LICENSED MASTER.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 5 May 1997
Resolved
MARK VESSEL'S HULL (P & S BOW) AND TRANSOM WITH VESSEL'S NAME. TRANSOM ALSO TO BE MARKED WITH HAILING PORT. (4" LTRS)
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 5 May 1997
Resolved
MARK FIXED CO2 LOCATION AND EMERGENCY FUEL SHUT-OFFS AS REQUIRED BY 46 CFR 185.608/.612.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 5 May 1997
Resolved
PROVIDE FIRST AID KIT MEETING OR EQUIVALENT TO 46 CFR 160.041.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 5 May 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 5 May 1997
Resolved
PROVIDE (1) CHILD SIZE & (9) ADULT SIZE CG APPROVED TYPE I LIFE JACKETS.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 5 May 1997
Resolved
PROVIDE 5 GPM HAND BILGE PUMP.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 5 May 1997
Resolved
PROVIDE EMERGENCY CHECK-OFF LIST MEETING 46 CFR 185.512.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 5 May 1997
Resolved
PROVIDE CG APPROVED 24" DIA. RING BUOY W/ 60' LINE ATTACHED. MARK WITH VESSEL'S NAME.
Condition: Unknown
Due 5 June 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 6 May 1996
Resolved
PROVIDE EVIDENCE OF COMPLIANCE FOR DRUG TESTING IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Engineering
Issued 29 June 1994
Resolved
ENGINE COMPARTMENT BLOWERS AND IGNITION SWITCH MUST BE INTERLOCKED TO PREVENT CRANKING OF ENGINE WITHOUT BLOWERS OPERATING.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Construction/Loadline
Issued 29 June 1994
Resolved
BULKHEAD BETWEEN PASSENGER SPACE AND ENGINE/FUEL TANK SPACE MUST BE VAPOR TIGHT.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Engineering
Issued 29 June 1994
Resolved
INSTALL PROPER VENT BLOWER UNIT PORTSIDE ENGINE SPACE.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Construction/Loadline
Issued 29 June 1994
Resolved
MAKE PROPER REPAIRS TO LONGITUDINAL CHANNEL FWD PORTSIDE.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Electrical
Issued 29 June 1994
Resolved
INSTALL GUARDS OVER OPEN ELECTRICAL TERMINAL STRIPS AND PROPERLY SUPPORT WIRING.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Engineering
Issued 29 June 1994
Resolved
FUEL TANK FILL AND VENT LINES MUST BE CONTINUOUS. NO PVC ELBOWS.(GOOD MARINE PRACTICE)
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Engineering
Issued 29 June 1994
Resolved
INSTALL PROPER SHUT OFF VALVE AT TANK FOR SUPPLY LINE TO ENGINE.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Engineering
Issued 29 June 1994
Resolved
REMOVE HINGED COVERS FROM ENGINE SPACE VENTILATION INTAKES AND EXHAUST OUTLETS.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Accommodation/Occupational Safety
Issued 29 June 1994
Resolved
MAKE PERMANENT REPAIRS TO RAILING STBD SIDE.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Lifesaving
Issued 29 June 1994
Resolved
LABEL LIFE JACKET LOCATION WITH ADULT OR CHILD AND NUMBER.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Fire Fighting
Issued 29 June 1994
Resolved
PROVIDE PROOF THAT PORTABLE AND FIXED EXTINGUISHERS HAVE BEEN SERVICED.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Unknown
Issued 29 June 1994
Resolved
PROVIDE EMERGENCY CHECK-OFF LIST FOR POSTING IN PASSENGER AREA.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Engineering
Issued 16 January 1990
Resolved
PROVIDES ADDITIONAL BILGE PUMP FOR AREA FORWARD OF ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Construction/Loadline
Issued 16 January 1990
Resolved
SEAL LOWER PORTION OF ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Construction/Loadline
Issued 16 January 1990
Resolved
REPAIR FRACTURED WELDS IN MIDSHIPS FLOOR FRAMING.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Lifesaving
Issued 16 January 1990
Resolved
PROVIDE 1 ADDITIONAL ADULT PFD. TOTAL ADULTS ON BOARD IS LIMITED TO 19.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Accommodation/Occupational Safety
Issued 16 January 1990
Resolved
REPLACE PLASTIC ENGINE ROOM VENT HOSES WITH VENTS CONSTRUCTED OF FIRE PROOFMATERIAL.
Condition: Unknown
Due 16 January 1990
Resolved 16 January 1990
Lifesaving
Issued 13 May 1987
Resolved
PROVIDE 31 SQUARE INCHES OF RETROREFLECTIVE MATERIAL ON EACH SIDE OF THE LIFE PRESERVERS (IN ACCORDANCE WITH 46 CFR 180.25-25).
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Fire Fighting
Issued 13 May 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE ONE ADDITIONAL B-I EXTINGUISHER (A TOTAL OF TWO B-I EXTINGUISHERS ARE REQUIRED).
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 13 May 1987
Resolved
PROVIDE INTERLOCK SWITCH IN IGNITION SYSTEM FOR ENGINES SO BLOWER WILL BE ACTIVATED BEFORE THE ENGINES CAN BE STARTED (IN ACCORDANCE WITH 46 CFR 182.15-45(D)).
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Lifesaving
Issued 28 August 1986
Resolved
PROVIDE (2) TWO ADDITIONAL CG APPROVED ADULT LIFE PRESERVERS FOR A TOTAL OF 20. THE VESSEL IS RESTRICTED TO CARRYING A TOTAL OF 18 PERSONS UNTIL THE ABOVE REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 28 August 1986
Resolved 28 August 1986