MAURY USCG vessel records Sign in
← All vessels

M G HULME JR

M G HULME JR is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 101 inspections since 1985, most recently in June 2005, along with 225 deficiencies, 1 operational control and 1 casualty investigation in 2003.

Records from 1985 to 2005. Most recent: inspection, 23 June 2005.

Built
1983
Last inspected
23 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
MARSHALL ISLANDS
366305000 (licence lapsed)
Maury page id
psix-55222

Inspections, by type

…with no type recorded14
Years with a record 20 calendar years (1985–2005)
The 101 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it7977 - Regulatory (Subpart C or D), Gross Ton
5866 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

KSLFMMSI 366305000 · expired · compulsorily equipped · granted 27 August 1998, cancelled 1 November 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 101

23 June 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2399956
17 June 2003 Administrative Inspection
Administrative · Activities Europe · Activity 1819521
19 April 2003 Type not recorded
No type recorded · Activities Europe · Activity 1776508
18 March 2003 Type not recorded
No type recorded · Activities Europe · Activity 1758924
9 February 2003 COI Inspection
Physical examination · Activities Europe · Activity 1741922
22 July 2002 Periodic Inspection
Physical examination · Activities Europe · Activity 1628693
13 February 2002 Administrative Inspection
Administrative · Activities Europe · Activity 1486018
7 January 2002 Underwater Inspection in lieu of Drydock
Physical examination · Activities Europe · Activity 1475860
4 January 2002 Deficiency Check
Physical examination · Activities Europe · Activity 1475454
11 October 2001 Administrative
Administrative · Activities Europe · Activity 1075538
30 August 2001 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1453934
4 June 2001 Hull Examination · Re-Inspection
Physical examination · Activities Europe · Activity 1362313
19 March 2001 Deficiency Check
Physical examination · Activities Europe · Activity 1059759
9 August 2000 Deficiency Check
Physical examination · Activities Europe · Activity 1369791
25 July 2000 Deficiency Check
Physical examination · Activities Europe · Activity 1051639
9 June 2000 COI Inspection
Physical examination · Activities Europe · Activity 1413753
10 August 1999 Deficiency Check
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1112184
28 May 1999 Re-Inspection · Hull Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 791654
28 January 1999 Administrative
Administrative · Activities Europe · Activity 1123771
6 January 1999 Administrative
Administrative · Activities Europe · Activity 810734
13 July 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1128499
20 June 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 106557
8 June 1998 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1400811
19 February 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778339
9 February 1998 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1109837
11 August 1997 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1117946
11 July 1997 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1390584
19 March 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098343
24 September 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138982
26 July 1996 Hull Examination · COI Inspection · Inclining Experiment
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1458307
21 February 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 884454
29 June 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 881549
26 June 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189979
14 June 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1190073
31 May 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 873913
16 May 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231587
5 May 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1030580
14 April 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158092
5 April 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458214
21 February 1995 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400141
17 February 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 91501
16 February 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 3802
26 January 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 826315
16 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840942
25 October 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 864539
13 October 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 865588
5 October 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862505
5 October 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172459
22 September 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175671
31 August 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 862538
19 July 1994 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363050
15 July 1994 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 863012
7 July 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1173858
1 June 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 861108
29 April 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 858757
6 April 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165838
29 March 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1166762
29 March 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389793
14 January 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1162620
5 October 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158194
23 September 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1151976
25 August 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831432
16 June 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 841092
6 June 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 46400
20 May 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136116
21 March 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1148200
20 November 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1139288
15 October 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 831032
20 August 1992 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 933106
17 March 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 953808
14 February 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944322
26 September 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935769
15 August 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248506
18 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 934606
17 June 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249970
29 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1248366
23 May 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252466
15 April 1991 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330222
30 March 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928792
16 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 905038
10 May 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927876
9 April 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 911053
29 March 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1234136
19 March 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 904280
26 January 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1233973
24 January 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926663
24 August 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 926886
5 June 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351509
19 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034775
30 March 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 892984
31 March 1988 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 991806
31 March 1988 Examination of Repairs · Re-Inspection · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031133
8 September 1987 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1314443
2 July 1987 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331751
29 April 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020444
13 April 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1004980
13 April 1987 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1311200
30 January 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308136
18 April 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303219
9 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1290940
12 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1288032

Deficiency record · 225

Fire Fighting › Fixed CO2 Fire Extinguishing System › Tanks
Issued 24 March 2003 Resolved
Provide eight (8) CO2 cylinders within hydro date for mud pump room, until installed all use of mud pumps is to stop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Structures › Air Pipe
Issued 24 March 2003 Resolved
Make proper structrual repairs to helicopter deck, repairs must be made immediately to allow continued use, damaged area must have all welds tested by magnetic particle NDT and load tested to largest helicopter or 42,000# and only one helicopter can be on helo deck at centerline. LEGACY COMPONENT DESC: Helicopter Deck
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 March 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Structures › Air Pipe
Issued 24 March 2003 Resolved
Make proper repairs to all sampson posts, support posts, and frames on pipe deck. Installed posts, supports, and frames have numerous fractures in welds and are deteriorated. LEGACY COMPONENT DESC: Deck Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Structures › Deck Plating
Issued 24 March 2003 Resolved
Provide NDT of entire pipe deck - deck plate, shots to be taken on 1 foot grid pattern. Entire deck shows heavy pitting and wastage, note this is a highly loaded deck during drilling operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 24 March 2003 Resolved
Provide CG-2692 for accident involving collision between rig and OSV Maersk Rover on 7 DEC 02.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 2003
Resolved 25 March 2003
Resolution: Submitted CG-2692
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 24 March 2003 Resolved
Prove proper operation of starboard column OWS, IOPP issued by ABS, IOPP due to expire on 31 MAR 03.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving › Lifeboat Equipment › Radar Transponder
Issued 24 March 2003 Resolved
Provide SART for #1 & #2 lifeboats. According to rig SART's were sent out for servicing in DEC 02.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving › Lifebuoys › Stowage
Issued 24 March 2003 Resolved
Repair all ring buoy's and waterlight brackets, and retro tape on aft ring buoy.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 24 March 2003 Resolved
Conduct & provide copy of annual servicing of portable fire extinguishers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 March 2003 Resolved
Remove third party shale shaker from aft deck or permanently mount & classify inside enclosure and add to Hazardous Location plan. LEGACY COMPONENT DESC: Classified Hazardous area''s
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 March 2003 Resolved
Make permanent repairs to shale shaker room bulkheads that are holed/wasted to maintain Hazardous Location Classification Plan. LEGACY COMPONENT DESC: Hazardous Location
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 24 March 2003 Resolved
Prove proper operation of all fire alarms and general alarms & label properly. LEGACY COMPONENT DESC: Alarms
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Structures › Cofferdam
Issued 24 March 2003 Resolved
Make immediate repairs to fractured deck starboard side of moon pool slot @ trolley adjustment posts forward & aft. LEGACY COMPONENT DESC: Deck Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 24 March 2003 Resolved
Immediately renew time delay (30 seconds) cylinder on Control Room / SCR Room CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 24 March 2003 Resolved
Renew all broken windows in port, starboard, and aft cranes. LEGACY COMPONENT DESC: Crane windows
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 24 March 2003 Resolved
Provide one boat hook in #1 lifeboat, provide watertight locker for #2 lifeboat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Construction/Loadline › Structures › Machinery Space Opening
Issued 24 March 2003 Resolved
Make proper repairs to entire bulkhead of "bowling alley" / fan space outside accomodations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 24 March 2003 Resolved
Make proper repairs to hand rails through out rig, numerous broken, missing, holed. LEGACY COMPONENT DESC: Hand rails
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 24 March 2003 Resolved
Make proper repairs to all interior door closures and latches. LEGACY COMPONENT DESC: Stair tower door, passage way doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 March 2003 Resolved
Immediately repair self-closing doors to mud pit room & loss of ventilation alarm. LEGACY COMPONENT DESC: Mud Pit Room Alarms & Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 24 March 2003 Resolved
Immediately repair catwalk support for starboard tensioner at the drill floor level where support attaches to windwall. LEGACY COMPONENT DESC: Cat Walk Supports
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 23 June 2005
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving › Hand Flares › Approval
Issued 24 March 2003 Resolved
Immediately provide six parachute flares for rig.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 24 March 2003 Resolved
Provide ventilation for laundry room & repair door frame (just proped again bulkhead).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Stability › Watertight Integrity › General
Issued 24 March 2003 Resolved
Repair all watertight doors and provide gaskets. LEGACY COMPONENT DESC: Doors & Gaskets
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Stability › Watertight Integrity › General
Issued 24 March 2003 Resolved
Immediately repair all remote controlled ballast, bilge, fuel, drill water, salt water valves in port and starboard pump rooms. LEGACY COMPONENT DESC: Remote Controlled Valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Stability › Watertight Integrity › General
Issued 24 March 2003 Resolved
Immediately repair Class III watertight door to port propulsion room to close manually. LEGACY COMPONENT DESC: Class III Watertight Doors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 March 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Stability › Watertight Integrity › General
Issued 24 March 2003 Resolved
Repair upper hinge on watertight door to mud pump room starboard side. LEGACY COMPONENT DESC: Watertight Door to Mud Pump Room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 24 March 2003 Resolved
Immediately repair all four steel A-60 roll down windows between galley and messdeck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 24 March 2003 Resolved
Properly label all fire call boxes. LEGACY COMPONENT DESC: Fire Call Boxes
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Electrical › Electric Supply System (service) › Cable
Issued 24 March 2003 Resolved
Make proper electrical penetration to mud pit room bulkhead to maintain hazardous classification portside. LEGACY COMPONENT DESC: Cable Penetration
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Stability › Watertight Integrity
Issued 22 July 2002 Resolved
Vessel to make permanent repairs to port and starboard ballast piping in lower hulls, at a minimum, piping that has doubler patches at this time. Vessel to provide U/T gagings on remaining piping in lower hulls. U/T reading to be provided to [name withheld] DESC: Ballast piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 10 August 2002
Resolved 19 September 2002
Resolution: Elbows renewed, received gauging report
Fire Fighting › Fire Main
Issued 22 July 2002 Resolved
Vessel to make permanent repairs to fire main piping that is holed, leaking, has doublers, or has heavy corrosion. Remain piping through out rig to be U/T and provide U/T report to [name withheld] DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 October 2002
Resolved 19 September 2002
Resolution: 75 percent of fire main renewed. Received copy of gauging report.
Personnel › Certificates/Documents/Licenses
Issued 22 July 2002 Resolved
Vessel to have a licensed second BCO in accordance with manning requirements listed on COI. Vessel not to move until second licensed BCO is aboard. LEGACY COMPONENT DESC: License, Ballast Control Operator
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Cleared
Personnel › Certificates/Documents/Licenses
Issued 22 July 2002 Resolved
Vessel to provide four (4) lifeboatmen in accordance with manning listed on COI, with valid STCW 95 endorsements. Vessel to provide prior to departing Malabo, EG. LEGACY COMPONENT DESC: STCW Certificate of Proficiency, Survival Craft
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Non self propelled.
Personnel › Certificates/Documents/Licenses
Issued 22 July 2002 Resolved
Vessel to provide valid STCW 95 endorsements for (1) OIM, (2) BCO, (4) Lifeboatmen, prior to rig movement from Malabo, EG. LEGACY COMPONENT DESC: STCW Endorsement
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Non self propelled.
Engineering › Pressure Vessel
Issued 22 July 2002 Resolved
Vessel to provide means to internally inspect 28 Varco air recievers on tensioner system, or hydrostatically test at 1.25 times MAWP, or have a certified third party inspection company conduct inspection and provide [name withheld] with report.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 March 2003
Resolved 19 September 2002
Resolution: Received copy of examination report.
Stability › Watertight Integrity › Coaming
Issued 22 July 2002 Resolved
Vessel to repair and adjust all watertight doors, hatches through out rig and chalk test. LEGACY COMPONENT DESC: Doors/hatches
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Stability › Weathertight Integrity › General
Issued 22 July 2002 Resolved
Vessel to repair and adjust all weathertight doors and hatches through out rig and hose test. LEGACY COMPONENT DESC: Doors/hatches
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Stability › Weathertight Integrity › General
Issued 22 July 2002 Resolved
Vessel to make accomodation outer bulkheads on weather decks weathertight, repair holed areas. LEGACY COMPONENT DESC: Outer bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 July 2002 Resolved
Vessel to service all emergency lighting to include replacement of weak batteries, burned out bulbs, switches, and adjust direction of lighting to exits, machinery or system served.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 July 2002 Resolved
Vessel to repair all leaking piping in engine room, to include cooling water to air compressor system, main generator cooling water valves and piping, salt water service piping, and drill water piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Engineering › Non-conventional Propulsion/Steering
Issued 22 July 2002 Resolved
Vessel to make necessary repairs or adjustment to shaft packing glands on propulsion assist units port and starboard. Repairs to be made prior to until going to drilling drafts. LEGACY COMPONENT DESC: Propeller Shaft (z-drive)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Stern tube packing renewed.
Electrical › Electric Supply System (service)
Issued 22 July 2002 Resolved
Vessel to remove all pigtail extension cords from drill floor within the Class 1 Div 1 area. LEGACY COMPONENT DESC: Explosion proof fixture/pressurized
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Pigtails and extension cords removed.
Electrical › Electric Supply System (service)
Issued 22 July 2002 Resolved
Vessel to replace broken glass on front of diverter control box in drillers stand, this is a pressurized enclosure in a Class 1 Div 1 area. No drill operations allowed until corrected.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Glass replaced with plexiglass
Electrical › Lighting (service)
Issued 22 July 2002 Resolved
Vessel to provide safety cables for all lighting in hazardous locations, mud pit room, shale shaker room, drill floor below wind wall, and mud pump room.. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Corrected
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 22 July 2002 Resolved
Replace portable extinguisher #4 in shale shaker room, unit has heavy corrosion on bottom of unit. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Extinguisher renewed
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2002 Resolved
Vessel to provide proper warning signs for helicopter access points & helicopter fueling station as per 46 CFR 108.653. LEGACY COMPONENT DESC: Helicopter deck access
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Warning signs posted.
Fire Fighting › International Shore Connection
Issued 22 July 2002 Resolved
Vessel to provide international shore connection and mean to connect to vessels fire main system port and starboard as per 46 CFR 108.427. LEGACY COMPONENT DESC: Connection
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: International shore connections provided.
Fire Fighting › Fixed Low-Expansion Foam Fire Extinguishing System
Issued 22 July 2002 Resolved
Vessel to provide clear access to to foam firefighting system in the 8' level area at the local pump contol panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Foam room tidied up.
Fire Fighting › Ventilation Systems
Issued 22 July 2002 Resolved
Provide, repair, adjust covers on all ventilation closures through out rig. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Vent closurers repaired.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 22 July 2002 Resolved
Make proper sanitary conditions through out rig, including mold in showers, broken floor tiles in messroom, showers, food prep area filthy, cleaniness of food handlers, rotten food in dry stores, in reefers, reefer temps, no hot water for food worker to wash hands, no hot water in rooms. LEGACY COMPONENT DESC: Sanitation conditions
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Fire Fighting › Structural - A Class Divisions
Issued 22 July 2002 Resolved
Adjust, repair all stair tower doors, door will not latch/close properly. LEGACY COMPONENT DESC: Decks - Stairways
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Doors repaired.
Documentation › Certificates/Documents
Issued 22 July 2002 Resolved
Vessel to provide valid certificate prior to operating. LEGACY COMPONENT DESC: Cargo Gear Safety Certificate
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Cargo gear certificate on board.
Lifesaving › Inflatable Liferafts
Issued 22 July 2002 Resolved
Vessel to provide USCG approved DL liferafts for rafts 1 & 2, rafts must be new or serviced by a USCG approved servicing station. LEGACY COMPONENT DESC: Servicing
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: New BFG Rafts on board
Fire Fighting › Ventilation Systems
Issued 22 July 2002 Resolved
Remove all door hold backs on accomodations hallway access doors. LEGACY COMPONENT DESC: Door hold backs
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Hold backs removed.
Fire Fighting › Fixed Deck Foam System › Foam Applicators
Issued 22 July 2002 Resolved
Vessel to discharge foam from all foam F/F stations for 15 seconds.
Condition: Improper/Lack of Maintenance
Due 22 July 2002
Resolved 22 July 2002
Resolution: Cleared during inspection.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2002 Resolved
Conduct required internal, external and pressure test for helicopter fuel marine portable tanks on bow of rig. LEGACY COMPONENT DESC: Marine Portable Tanks MPT
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Tanks on board examined and tested.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2002 Resolved
Vessel to provide standard hand signal chart for all three cranes. LEGACY COMPONENT DESC: Cranes
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Hand signals posted.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2002 Resolved
Vessel to repair broken hand rails on port crane. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Rail repaired.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 July 2002 Resolved
Vessel to repair/renew all broken, wasted, missing pipe hangers and supports through out rig. LEGACY COMPONENT DESC: Piping support
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 25 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 July 2002 Resolved
Vessel to stencil quanity of life jackets stowed in boxes on deck. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Boxes marked satisfactory.
Accommodation/Occupational Safety › Occupational Safety
Issued 22 July 2002 Resolved
Vessel to renew wasted fuel oil hose on port crane. LEGACY COMPONENT DESC: Crane fuel system
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Crane fueling hose renewed.
Pollution Prevention/Response › Prevention Equipment
Issued 22 July 2002 Resolved
Vessel to correct all oil pollution sources on rig, vessel has overflowing portable containment drums and inside fixed containment, and run off areas in machinery areas. LEGACY COMPONENT DESC: Portable Containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 22 July 2002
Lifesaving › Lifebuoys
Issued 22 July 2002 Resolved
Vessel to stencil homeport on all lifebouys. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Completed satisfactory.
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 July 2002 Resolved
Vessel to repair broken head door in hospital space. LEGACY COMPONENT DESC: Hospital Space
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Door repaired.
Lifesaving › Lifeboat
Issued 22 July 2002 Resolved
Vessel to operate #1 and #2 lifeboats in the water and log testing results. LEGACY COMPONENT DESC: Operation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 22 July 2002 Resolved
Vessel to meet hospital described in 46 CFR 108.209. LEGACY COMPONENT DESC: Hospital Space
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 19 September 2002
Resolution: Hospital meets optional requirement.
Lifesaving › Launching Appliances
Issued 13 February 2002 Resolved
PROVIDE NEW HYDROSTATIC RELEASE MECHANISMS FOR ALL 4 LIFERAFTS, CURRENT EXPIRED DEC 2001 LEGACY COMPONENT DESC: Release Mechanism
Action required: 705 - Other - as specified
Due 19 September 2002
Resolved 19 September 2002
Resolution: cleared
Construction/Loadline
Issued 4 June 2001 Resolved
Make port ballast tanks #1, 3, 9, 10, & 11 available for internal examination.
Condition: Unknown
Due 30 September 2001
Resolved 17 December 2001
Lifesaving › Buoyant Apparatus › Approval
Issued 4 June 2001 Resolved
Submit a new safety plan to reflect changes made to berthing areas.
Condition: Unknown
Due 31 October 2001
Resolved 18 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Accommodation/Occupational Safety
Issued 4 June 2001 Resolved
Make the crane air receivers available for internal examination.
Condition: Unknown
Due 30 September 2001
Resolved 17 December 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Crop and renew the discharge piping for the port ballast pump as marked.
Condition: Unknown
Due 31 October 2001
Resolved 19 September 2002
Resolution: Renewed satisfactory.
Construction/Loadline
Issued 4 June 2001 Resolved
Crop and renew the discharge piping for the starboard ballast pump as marked.
Condition: Unknown
Due 31 October 2001
Resolved 19 September 2001
Resolution: Renewed satisfactory.
Fire Fighting
Issued 4 June 2001 Resolved
Crop and renew the piping for the fire main in the breezeway.
Condition: Unknown
Due 25 June 2001
Resolved 25 June 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Conduct NDT on hull in accordance with the 1st schedule of the Structural Inspection and Underwater Survey Plan.
Condition: Unknown
Due 30 September 2001
Resolved 17 December 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Make starboard ballast tanks #1 & 11 available for internal survey.
Condition: Unknown
Due 30 September 2001
Resolved 17 December 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Make the starboard drill water tanks available for internal inspection.
Condition: Unknown
Due 30 September 2001
Resolved 17 December 2001
Electrical
Issued 4 June 2001 Resolved
Remove all non-essential loads from the emergency generator power distribution panel.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Provide dogging wrenches for all watertight doors.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Engineering
Issued 4 June 2001 Resolved
Prove proper operation of the starboard oily water separator.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Accommodation/Occupational Safety
Issued 4 June 2001 Resolved
Make the following bulk tanks available for internal examination: #1, 2, 3,4, 5, 6, & 12.
Condition: Unknown
Due 30 September 2001
Resolved 17 December 2001
Accommodation/Occupational Safety
Issued 4 June 2001 Resolved
Make the following tensioner bottles available for internal examination; #1& 2.
Condition: Unknown
Due 30 September 2001
Resolved 17 December 2001
Accommodation/Occupational Safety
Issued 4 June 2001 Resolved
Submit plans for the elevator control panel upgrade.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Accommodation/Occupational Safety
Issued 4 June 2001 Resolved
Crop and renew the supply vent duct to the port side change room.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Accommodation/Occupational Safety
Issued 4 June 2001 Resolved
Crop and renew the supply vent duct to the port side change room.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Lifesaving
Issued 4 June 2001 Resolved
Replace ten (10) expired provisions in the #1 lifeboat.
Condition: Unknown
Due 31 October 2001
Resolved 22 July 2002
Resolution: Renewed.
Lifesaving
Issued 4 June 2001 Resolved
Replace twenty (20) expired provisions in the #2 lifeboat.
Condition: Unknown
Due 31 October 2001
Resolved 22 July 2002
Resolution: Renewed
Lifesaving
Issued 4 June 2001 Resolved
Have life rafts # 1 & 2 serviced by a qualified servicing facility.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Fire Fighting
Issued 4 June 2001 Resolved
Renew all flex hoses on teh fixed extinguishing systems.
Condition: Unknown
Due 31 October 2001
Resolved 17 December 2001
Lifesaving
Issued 9 June 2000 Resolved
Provide 1 hour training for personnel in supervisory positions. Document training.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Construction/Loadline
Issued 9 June 2000 Resolved
Crop and renew wasted aft bulkhead in the engine room.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 9 June 2000 Resolved
Provide breath testing devices onboard unit.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 9 June 2000 Resolved
Repair elevator call at the 34" level in the starboard hull.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Construction/Loadline
Issued 9 June 2000 Resolved
Repair water tight door operating alarms.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 9 June 2000 Resolved
Repair the galley serving windows so they can be closed from both sides of the galley.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Engineering
Issued 9 June 2000 Resolved
Crop and renew wasted sections of 12' COOLING WATER PIPING.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 9 June 2000 Resolved
Helicopter deck is to be covered with a non-skid surface.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Fire Fighting
Issued 9 June 2000 Resolved
Have the fixed firefighting system serviced by a qualified service technician. Fax copy of completed report to MIO Europe at 31-10-450-4752.
Condition: Unknown
Due 6 July 2000
Resolved 6 July 2000
Lifesaving
Issued 9 June 2000 Resolved
Relocate EPIRB to a position where it can "float free".
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Construction/Loadline
Issued 9 June 2000 Resolved
Provide a class "A" steel door for the laundry room.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 9 June 2000 Resolved
Replace cracked glass in the aft water maker.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Lifesaving
Issued 9 June 2000 Resolved
Provide new first aid kits for the lifeboats.
Condition: Unknown
Due 9 June 2000
Resolved 9 June 2000
Fire Fighting
Issued 28 May 1999 Resolved
PROVE OPERATION OF MUD PUMP ROOM LOUVERS ON ACTIVATION OF CO2 SYSTEM.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 28 May 1999 Resolved
HYDROTEST MEDICAL OXYGEN CYLINDER OR REPLACE WITH CYLINDER WITH VALID HYDROTEST DATE.
Condition: Unknown
Due 28 May 1999
Resolved 28 May 1999
Lifesaving
Issued 11 July 1997 Resolved
REPAIR THE FOLOLOWING GENERAL ALARM: MOTOR ROOM, A/COMPRESSOR ROOM, ELECTRIC SHOP, MUD PIT ROOM, HALIBURTION ROOM, MAIN DECK BREEZEWAY
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL NEW GENERAL ALARMS IN SUPPLY ROOM
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Electrical
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL JUNCTION BOXES FOR DEAD END CABLE TO REPLACE OLD BILGE ALARMS PANEL BOXES IN CONTGROL ROOM
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL NEW DECK GRATING BELOW THE NO. 1&2 LIFE RAFTS.
Condition: Unknown
Due 11 August 1997
Resolved 17 July 1997
Navigation
Issued 11 July 1997 Resolved
REPAIR OR REMOVE BROKEN RADAR IN PILOT HOUSE
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL SHUTDOWN SWITCHES FOR HELIPORT FUEL PUMP AT EACH LADDERLEADING FROM HELIPORT. VESSEL IS RESTRICTED FROM FUELING HELICOPTER UNTIL THESE SWITCHES HAVE BEEN INSTALLED
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
REPAIR AND INSTALL MISSING GENERAL ALARM BELL ON PORT SIDE OF MOTOR ROOM
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Accommodation/Occupational Safety
Issued 11 July 1997 Resolved
REPAIR BROKEN TOILET IN PORT CHANGE ROOM
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL HOLD DOWN FOR HELIPORT B-V EXTINGUISHERS
Condition: Unknown
Due 11 August 1997
Resolved 17 July 1997
Lifesaving
Issued 11 July 1997 Resolved
STENCIL LIFE RAFT CAPACITY AND NO. ON BHD BY LIFE RAFTS.
Condition: Unknown
Due 11 August 1997
Resolved 17 July 1997
Lifesaving
Issued 11 July 1997 Resolved
CONDUCT OPERATION TEST OF NEW BOP ALARM PANEL PURGE ALARM PROIR TO PLACING SYSTEM IN OPERATION
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Fire Fighting
Issued 11 July 1997 Resolved
REPLACE THREE SECTION OF 1.5 FIRE HOSE.
Condition: Unknown
Due 11 July 1997
Resolved 14 July 1997
Lifesaving
Issued 11 July 1997 Resolved
REPAIR FLOODING ALARM IN COLUMN 2S AT 50-85' LEVEL
Condition: Unknown
Due 11 August 1997
Resolved 16 July 1997
Electrical
Issued 11 July 1997 Resolved
REMOVE THE SHUTDOWN ON THE EMERGENCY GENERATOR PRIME MOVER FOR LOW LUBE OILAND HIGH TEMP. SHOULD ALARM ONLY
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Unknown
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL MISSING INSULATION FOR SCR CONTROL ROOM FRONT
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
REPLACE ALL RING BUOYS WITH PROPER SIZE, COLOR AND MARKING.
Condition: Unknown
Due 11 August 1997
Resolved 17 July 1997
Electrical
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL RUBBER MATTING FOR CONTROLLER PANELS IN A/C FLAT
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
INSTALL RETRO REFLECTIVE MATERIAL (MARKING) ON THE NO. 1 AND 2 LIFE BOATS.
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Accommodation/Occupational Safety
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL MISSING GALLEY DECK DRAIN PIPING SO DRAINS EITHER DRAINS INTO A HOLDING TANK OR AS ORGINAL THRU PORT FWD COLUMN TO BELOW THE 65' LEVEL
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
PROVIDE ON BOARD ALL NEW PFD'S (LIFEJACKETS) COAST GUARD APPROVRD FOR SOLASUSE. VESSEL IS RESTRICTED TO DOMESTIC VOYAGE ONLY UNITL THIS ITEM IS CORRECTED
Condition: Unknown
Due 13 August 1997
Resolved 13 August 1997
Lifesaving
Issued 11 July 1997 Resolved
PROVIDE AND INSTALL INSTRUCTION FOR LAUNCHING THE LIFE BOATS.
Condition: Unknown
Due 11 August 1997
Resolved 17 July 1997
Documentation
Issued 26 July 1996 Resolved
UPDATE AND OBTAIN APPROVAL OF RIGS OPERATING MANUAL WITH ISSUE OF NEW STABILITY LETTER.
Condition: Unknown
Due 3 September 1996
Resolved 3 September 1996
Fire Fighting
Issued 5 April 1995 Resolved
PROVIDE FOR EACH FIRE PUMP A RELIEF VALVE ON THE DISCHARGE SIDE OF THE PUMPTHAT IS SET TO RELIEVE AT (1) APPROX. 25 PSI IN EXCESS OF THE PUMP DISCHARGE PRESSURE NECESSARY TO MEET PRESSURE REQUIRED BY 46CFR108.415 OR (2) 125 PSI, WHICHEVER IS GREATER.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Fire Fighting
Issued 5 April 1995 Resolved
CLEAN, PREP AND PAINT ALL EXTERIOR FIRE MAIN PIPING AS NECESSARY TO ARREST CORROSION.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 5 April 1995 Resolved
ADJUST/REPAIR WATERTIGHT DOORS ON PORT AND STARBOARD #2 COLUMNS.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Electrical
Issued 5 April 1995 Resolved
REPAIR OR REPLACE MUD PIT ROOM DOORS AND MAKE GAS TIGHT.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 5 April 1995 Resolved
PROVIDE REPAIR PROPOSAL REGARDING DECK IN VICINITY OF HELICOPTER FUEL TANK.
Condition: Unknown
Due 5 April 1995
Resolved 5 April 1995
Construction/Loadline
Issued 19 July 1994 Resolved
COMPLETE REPAIRS TO INDICATIONS ON HORIZONTAL CROSS MEMBER TO #3 CAISSON (AREA #9).
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Construction/Loadline
Issued 19 July 1994 Resolved
COMPLETE REPAIRS TO INDICATION ON #4 FAIR LEAD.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Construction/Loadline
Issued 19 July 1994 Resolved
MAKE DESIGNATED "FALL '94 STRUCTURAL INSPECTION" TANKS AVAILABLE FOR INTERNAL EXAM.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Construction/Loadline
Issued 19 July 1994 Resolved
COMPLETE MPI ON UNDERSIDE OF HORIZONTAL K-BRACE TO #1 HORIZONTAL CROSS MEMBER (AREA 20).
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Navigation
Issued 29 March 1994 Resolved
REPROGRAM FOG HORN & OBSTRUCTION LIGHTS.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 29 March 1994 Resolved
REMOVE CUT CONDUCTOR IN LOWER SHAKER HOUSE.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Accommodation/Occupational Safety
Issued 29 March 1994 Resolved
PROVIDE COMMANDANT (G-MSC) APPROVAL OF GENERAL ALARM CONTACT MAKER INSTALLATION AS PER 46CFR113.25-5(D).
Condition: Unknown
Due 29 April 1994
Resolved 7 April 1994
Fire Fighting
Issued 29 March 1994 Resolved
CALIBRATE FIRE PUMP DISCHARGE PRESSURE GAUGE IN CONTROL ROOM.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 29 March 1994 Resolved
REPAIR AS NECESSARY EMERGENCY GENERATOR FUEL SHUT-OFF VALVE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Accommodation/Occupational Safety
Issued 29 March 1994 Resolved
REPLACE GENERAL ALARM CONTACT MAKERS WITH TYPE INDICATED IN 46CFR113.25- 11._x001C_
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Fire Fighting
Issued 29 March 1994 Resolved
HAVE INDEPENDENT SERVICE COMPANY SERVICE ALL FIRE EXTINGUISHING EQUIPMENT/SYSTEMS.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Engineering
Issued 29 March 1994 Resolved
HYDROSTATICALLY TEST FUEL TRANSFER HOSES.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 29 March 1994 Resolved
INSTALL EXPLOSION-PROOF CONNECTORS (CLASS I, DIVISIONS I) TO SHAKER SWITCHES, LOUDSPEAKER, AND SHAKER MOTORS.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Fire Fighting
Issued 29 March 1994 Resolved
REMOVE AND REPLACE ALL STAINLESS STEEL FIRE EXT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 29 March 1994 Resolved
REPAIR EMERGENCY EMBARKATION LIGHT BETWEEN LIFEBOAT #2 AND LIFERAFTS.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 29 March 1994 Resolved
PROVIDE ROSITIVE PRESSURE/PURGE WITH FAILURE ALARM (TO CONTROL ROOM) TO AIRLOCK BETWEEN LOWER SHALE SHAKER HOUSE AND PUMPROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Electrical
Issued 29 March 1994 Resolved
REPAIR/PROVE PROPER OPERATION OF PURGE SYSTEMS/ALARMS ON BOP PANEL AND SUB-SEA T.V. MONITOR.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Electrical
Issued 29 March 1994 Resolved
INSTALL BLANKS IN DISTRIBUTION PANEL L-207.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Engineering
Issued 29 March 1994 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Lifesaving
Issued 21 March 1993 Resolved
PROVIDE PROPER GAS TIGHT DOORS AND FRAMES TO BOUNDARIES BETWEEN MUD PIT ANDMUD PUMP ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Unknown
Issued 21 March 1993 Resolved
HYDROSTATICALLY TEST (10) TEN TENSIONER BOTTLES IAW 46 CFR 61.10 INCLUDING RELIEF VALVES OR BY ULTRASONIC TESTING BY CERTIFIED TECHNICIAN AS PER DIAGRAM SUBMITTED BY USCG INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Electrical
Issued 21 March 1993 Resolved
NUMBER ALL PANEL BOARD CIRCUIT BREAKERS AND PROVIDE UPDATED CIRCUIT DIRECTORIES IAW 46 CFR 111.40-11.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Unknown
Issued 21 March 1993 Resolved
HYDROSTATICALLY TEST TRANSFER HOSES IAW 33 CFR 155.800 AND 33 CFR 154.500._x001C__x001C_
Condition: Unknown
Due 7 April 1993
Resolved 7 April 1993
Deck/Cargo
Issued 21 March 1993 Resolved
PROVIDE CG APPROVED RELIEF VALVES WITH STAMPED SETTING NOT MORE THAN MAWP OF ALL BULK TANKS. TEST VALVES IAW 46 CFR 61.10-5 (I) AND 46 CFR 54.15- 5(I)._x001C_ _x001C_
Condition: Unknown
Due 16 June 1993
Resolved 16 June 1993
Documentation
Issued 21 March 1993 Resolved
SUBMIT OPERATION MANUAL FOR USCG APPROVAL IN ACCORDANCE WITH 46 CFR 109.121.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Documentation
Issued 21 March 1993 Resolved
PROVIDE AND PERMANENTLY POST OIL TRANSFER PROCEDURES, IN ACCORDANCE WITH 33CFR 155.700 THRU 33 CFR 155.760.
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Fire Fighting
Issued 21 March 1993 Resolved
PROVIDE EVIDENCE OF USCG PLAN APPROVAL FOR CO2 SYSTEMS FOR CONTROL ROOM ANDENGINEROOM/MUD PIT ROOM. IN LIEU OF SUBMIT PLANS FOR USCG APPROVAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 March 1993
Resolved 21 March 1993
Unknown
Issued 15 October 1992 Resolved
PROVIDE [name withheld] WITH A COPY OF UNDERWATER VIDEO AND MPI REPORT OF SPECIAL SURVEY IN LIEU OF DRYDOCKING COMPLETED ON 15 OCT 92.
Condition: Unknown
Due 15 October 1992
Resolved 15 October 1992
Construction/Loadline
Issued 20 August 1992 Resolved
MAKE PORT/STBD. PONTOON BALLAST TANK AVAILABLE FOR INTERNAL INSPECTION NO LATER THAN 30 SEP 92.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Construction/Loadline
Issued 20 August 1992 Resolved
CONDUCT AN UNDERWATER HULL SURVEY, IN THE PRESENCE OF USCG INPSECTOR IN ACCORDANCE WITH APPROVED INSPECTION PLAN DATED 06 AUG 92 BY NYCMI DURING NEXT RIG MOVE, BUT IN NO CASE LATER THAN 30 SEP 92.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Construction/Loadline
Issued 17 March 1992 Resolved
COMPLETE MPI OF ALL AREAS AS PER ATTACHED SHEET AND MAKE PERMANENT REPAIRS TO ALL CRACKS FOUND TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINEINSPECTOR. ATTACHED SHEET ON FILE AT MIONY.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Construction/Loadline
Issued 17 March 1992 Resolved
OPEN ALL TANKS AND VOIDS IN BOTH PONTOONS FOR INTERNAL INSPECTION. ALSO CONDUCT A FULL SET OF GAUGINGS AT THE WIND AND WATERLINE OF ALL COLUMNS, ATTHE WIND AND WATERLINE OF BOTH PONTOONS AND BELT AND GIRTH OF BOTH PONTOONS.
Condition: Unknown
Due 17 March 1992
Resolved 17 March 1992
Accommodation/Occupational Safety
Issued 15 April 1991 Resolved
PROVIDE RELIEF VALVES WITH LIFTING DEVICES FOR ALL TEN TENSIONER BOTTLES LOCATED IN NO.2P COLUMN, AS REQUIREE DBY 46 CFR 54.15-10(C), OR ACCEPTABLE ALTERNATIVE AS ALLOWED BY 46 CFR 54.15-13.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Engineering
Issued 15 April 1991 Resolved
OPEN AND MAKE READY FOR INSPECTION THE BOILER MOUNTS FOR BOTH AUXILIARY BOILERS. INSPECTION OF MOUNTS TO BE COMPLETED TO THE SATISFACTION FO THE ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 15 April 1991
Resolved 15 April 1991
Fire Fighting
Issued 30 March 1991 Resolved
PROVIDE ACCORDANCE HYDROSTATIC TEST DATE FOR PAINT LOCKER.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Documentation
Issued 30 March 1991 Resolved
REVISE OPERATING MANUAL TO INCLUDE BALLAST STRIPPING SYSTEM AND PROVIDE [name withheld] WITH PROOF OF APPROVAL BY MARINE SAFETY CENTER AND COPY OF CORRESPONDING STABILITY LETTER.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Accommodation/Occupational Safety
Issued 30 March 1991 Resolved
PROVIDE FOR ACCEPTABLE INSPECTION AND/OR TESTING OF TEN AIR RECEIVERS (TENSIONER BOTTLES) LOCATED IN NO.2-P COLUMN THREE CRANE AIR RECEIVERS, ANDALL RESPECTIVE PRESSURE RELIEF DEVICES.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Construction/Loadline
Issued 30 March 1991 Resolved
PROVIDE [name withheld] WITH MATERIAL SPECIFICATION AND BASIS FOR RATINGS OF BALLAST STRIPPING SYSTEM COMPONENTS LISTED IN PARAGRAPH 1, OF MSC LTR DATED03 MAY 90, SER#MNI-00232.
Condition: Unknown
Due 30 March 1991
Resolved 30 March 1991
Engineering
Issued 29 March 1990 Resolved
PROVIDE A DRAINAGE LINE FROM THE DAY TANK AND SETTLING TANK VENT CONTAINMENT.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Deck/Cargo
Issued 29 March 1990 Resolved
REPLACE TWO MISSING FORK CHAINS ON FORKLIFT.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Deck/Cargo
Issued 29 March 1990 Resolved
REPLACE BRAKES ON FORKLIFT.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Fire Fighting
Issued 29 March 1990 Resolved
PROVIDE ONE ADDITIONAL FIRE EXTINGUISHER FOR FORKLIFT FUELING AREA.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Lifesaving
Issued 29 March 1990 Resolved
PROVIDE THIRTY ADDITIONAL LIFEJACKET LIGHTS.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Lifesaving
Issued 29 March 1990 Resolved
PROVIDE SIX ADDITIONAL SURVIVAL SUITS.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Lifesaving
Issued 29 March 1990 Resolved
REPLACE ALL FOOD PACKAGES IN #1 AND #2 MLR.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Lifesaving
Issued 29 March 1990 Resolved
REPLACE ALL MLB PARACHUTE FLARES.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Electrical
Issued 29 March 1990 Resolved
PROVIDE ONE REVOLVING RED BEACON INTHE DRILL FLOOR AREA THAT IS ACTIVATED BY THE GENERAL ALARM SYSTEM.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Deck/Cargo
Issued 29 March 1990 Resolved
PROVE UL RATING OF VESSEL'S FORKLIFT FOR USE IN CLASSIFIED HAZARDOUS LOCATION.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Deck/Cargo
Issued 29 March 1990 Resolved
PROVIDE A WARNING DEVICE FOR THE FORKLIFT.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Engineering
Issued 24 August 1989 Resolved
PROVIDE STILL PHOTOGRAPHS OF PORT AND STARBOARD KORT NOZZLES AND PROPELLERSSHOWING DETAILS OF ANY CORROSION, WELD DEFECTS OR OTHER DAMAGE.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Construction/Loadline
Issued 24 August 1989 Resolved
PROVIDE COPY OF AMERICAN BUREAU OF SHIPPING SURVEY REPORT OF UNDERWATER SURVEY OF AUGUST 1989 IN MALTA.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Construction/Loadline
Issued 24 August 1989 Resolved
PROVIDE NON DESTRUCTIVE TESTING REPORT OF CONDITION OF CRITICAL WELDS AND BRACE CONNECTIONS FOR UNDERWATE SURVEY OF AUGUST 1989 IN MALTA.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Documentation
Issued 30 March 1989 Resolved
PROVIDE EVIDENCE OF SATISFACTORY ANNUAL CRANE SURVEY.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Electrical
Issued 30 March 1989 Resolved
PROVIDE AND INSTALL HEAT SHIELDING OR INSULATION FROM THE TURBO-CHARGER TO THE EXHAUST LINE FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Engineering
Issued 2 July 1987 Resolved
MAKE PERMANENT REPAIRS TO THE PORT AND STARBOARD KORT NOZZLE AT THE NEXT DRYDOCKING. TEMPORARY REPAIRS TO BE COMPLETED BY 21JUL87.
Condition: Unknown
Due 2 July 1987
Resolved 2 July 1987
Navigation
Issued 13 April 1987 Resolved
PROVE THE PROPER OPERATION OF THE SHIP'S WHISTLE, FOG HORN, AND STARBOARD RUNNING LIGHT.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Construction/Loadline
Issued 13 April 1987 Resolved
PROVE THE PROPER OPERATION OF 21-S AND 23-S BILGE VALVES.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Unknown
Issued 13 April 1987 Resolved
PROVE THE PROPER OPERATION OF THE PORT AND STARBOARD OILY WATER SEPARATOR UNITS. ALL MACHINERY SPACE BILGE WASTES TO BE PUMPED INTO WASTE OIL TANK UNTIL PROPERLY OPERATIONAL.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Accommodation/Occupational Safety
Issued 13 April 1987 Resolved
MAKE AVAILABLE FOR COAST GUARD INSPECTION ALL BUT THE FOLLOWING PRESSURE VESSELS: A. P-TANKS #1-3/B. EMERGENCY AIR RECEIVER/C. RIG AIR RECEIVER - MUD PUMP ROOM/D. RIG AIR RECEIVER UNDER DRILL FLOOR. TO BE DONE DURING VESSEL'S DRYDOCKING.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Electrical
Issued 13 April 1987 Resolved
RENEW OR REPAIR 14 BATTERY OPERATED EMERGENCY LIGHTS LOCATED THROUGHOUT VESSEL.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Engineering
Issued 13 April 1987 Resolved
CONDUCT A 1 1/4 MAWP (188 PSI) HYDROSTATIC TEST OF THE 5 AND 4 INCH STEAM PIPING IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Unknown
Issued 13 April 1987 Resolved
ADJUST AND CALIBRATE THE H2S AND LEL GAS DETECTION SYSTEMS. PROVE THE PRO- PER OPERATION OF SAME.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Accommodation/Occupational Safety
Issued 13 April 1987 Resolved
SET ALL PRESSURE RELIEF VALVES AT OR BELOW THE MAWP OF THEIR RESPECTIVE PRESSURE VESSELS (COAST GUARD PRESSURE VESSELS ONLY).
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Electrical
Issued 13 April 1987 Resolved
INSTALL BATTERIES AND CIRCUIT BREAKER FOR THE BAUTEIL MONITOR IN SCR ROOM IN ACCORDANCE WITH ELECTRICAL REGULATIONS. SUBMIT ELECTRICAL PLANS OF THE INSTALLATION TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Navigation
Issued 13 April 1987 Resolved
REPLACE THE MISSING FORWARD ANCHOR LIGHT WITH APPROVED TYPE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Deck/Cargo
Issued 13 April 1987 Resolved
SUBMIT A LIST OF MATERIALS AND SPECIFICATIONS, ONE LIVE DIAGRAM, AND CONNECTION DETAILS FOR THE BASE OIL TANK PIPING MODIFICATION TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Fire Fighting
Issued 13 April 1987 Resolved
IN THE RADIO ROOM AND CONTROL ROOM, REPLACE ELECTRIC SOLENOIDS FOR FIRE DAMPERS (5) WITH HEAVY DUTY TYPE. PROVE THE PROPER OPERATION OF SAME.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Lifesaving
Issued 13 April 1987 Resolved
PROVIDE 2 COAST GUARD APPROVED SMOKE SIGNALS FOR RING BUOYS TO REPLACE SOLAS TYPE.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Unknown
Issued 13 April 1987 Resolved
INSTALL A BACKING ALARM ON FORKLIFT.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Fire Fighting
Issued 13 April 1987 Resolved
INSTALL A WARNING LIGHT IN MUD PUMP ROOM FOR CO2 SYSTEM.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Lifesaving
Issued 13 April 1987 Resolved
MAKE PERMANENT REPAIRS TO PATCHED CRACK IN CANOPY (STARBOARD QUARTER) OF NO. 1 LIFEBOAT.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Unknown
Issued 13 April 1987 Resolved
REPAIR LEAKING AIR SEAL ON THE BOP CONTROL PANEL (DRILLERS SHACK) AND PROVE THE PROPER OPERATION OF THE PURGE AIR ALARM FOR SAME.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Accommodation/Occupational Safety
Issued 13 April 1987 Resolved
PROVE THE PROPER OPERATION OF SHALE SHAKER ROOM VENTILATION ALARM.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Engineering
Issued 13 April 1987 Resolved
SET & SEAL SAFETY VALVES ON THE NO. 1 AND NO. 2 BOILERS AND CONDUCT AUTOMA-TION TESTS ON NO. 1 BOILER IN THE PRESENCE OF A COAST GUARD MARINE INSPEC- TOR.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Unknown
Issued 13 April 1987 Resolved
INSTALL GUARDS ON AIR TUGGERS (4) FOR GUIDELINE TENSIONERS.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Electrical
Issued 13 April 1987 Resolved
PROVIDE NON-CORROSIVE LINERS FOR THE EMERGENCY BATTERIES LOCATED IN THE BATTERY ROOM AND BOS'N STORES ROOM.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Fire Fighting
Issued 13 April 1987 Resolved
RENEW THE MECHANICALS SEALS ON THE NO. 1 , NO. 2 AND FOAM FIRE PUMPS.
Condition: Unknown
Due 13 April 1987
Resolved 13 April 1987
Lifesaving
Issued 18 April 1986 Resolved
REPLACE ONE MISSING RING BUOY SMOKE FLARE.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Electrical
Issued 18 April 1986 Resolved
REMOVE OR MAKE GAS TIGHT THE ANTENNA ON THE PORT SIDE BULKHEAD HELO WAITING ROOM.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Fire Fighting
Issued 18 April 1986 Resolved
PROVIDE U.S. COAST GUARD APPROVED BI FIRE EXTINGUISHER ON FORK TRUCK.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Fire Fighting
Issued 18 April 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Lifesaving
Issued 18 April 1986 Resolved
REPLACE ONE MISSING U.S. COAST GUARD APPROVED WATERLIGHT FOR RING BUOY.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Fire Fighting
Issued 18 April 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Construction/Loadline
Issued 18 April 1986 Resolved
REPLACE THE FOLLOWING BROKEN GLASS ON DOOR'S: (1) FROM PORT SACK STORAGE ROOM TO MAIN DECK. (2) FROM PORT CHANGE ROOM TO MAIN DECK. (3) IN STARBOARD AFT WINCH ROOM.
Condition: Unknown
Due 18 April 1986
Resolved 18 April 1986
Engineering
Issued 12 April 1985 Resolved
OPEN AUXILIARY BOILERS (1 & 2) WATERSIDES FOR INTERNAL ANNUAL INSPECTION BY COAST GUARD.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Engineering
Issued 12 April 1985 Resolved
BLANK OFF SLIDING DOOR BETWEEN RADIO ROOM (PROTECTED BY HALON) AND HELO WAITING ROOM AND PROVIDE PROPER CABLE PENETRATIONS FOR SAT COMM/NAV WIRE.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Documentation
Issued 12 April 1985 Resolved
CONDUCT ANNUAL ABS LOADLINE SURVEY.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985 Resolved
SERVICE 4 FLOAT FREE 25 MAN LIFERAFTS AND HYDROSTATIC RELEASING GEAR.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985 Resolved
PROVIDE 2 CG APPROVED FLOATING ORANGE SMOKE DISTRESS SIGNALS FOR EACH LIFEBOAT.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985 Resolved
ADD SUFFICIENT WATER RATIONS TO EACH LIFEBOAT TO PROVIDE EACH PERSON WITH 3 QUARTS (FOR 58 PERSONS).
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985 Resolved
FOR KILGORE LINE THROWING APPLIANCE PROVIDE ONE EXTRA ROCKET AND ONE SERVICE LINE.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Engineering
Issued 12 April 1985 Resolved
INTERNALLY EXAMINE ALL PRESSURE VESSEL WITH THE EXCEPTION OF THOSE BULK TANKS LISTED BELOW: CG # 81-028, 81-024, 81-025, 81-022 & 81-040.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Deck/Cargo
Issued 12 April 1985 Resolved
PROVIDE A FORK LIFT TRUCK RATED BY U.L. OR F.M. AND MEETING THE REQUIREMENTS OF 46 CFR 108.613.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985 Resolved
PROVIDE CG APPROVED SMOKE SIGNAL FOR STBD LIFE RING BUOY.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985

Casualty record · 1

18 March 2003Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 1758924
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record