HENRIETTA

HENRIETTA is a 1983 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in June 2026, along with 54 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 2 June 2026.

Built
1983
Last inspected
2 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 2 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-55232

Documentation record

Registered dimensions (L × B × D)63.3 ft × 20.0 ft × 5.7 ft
Registered tonnagegross 48 / net 32
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFREEPORT SHIPBUILDING & MARINE REPAIR INC · FREEPORT, FL, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portWILMINGTON, NC
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
32 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 23

2 June 2026 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8383681
8 January 2026 Vessel Attendance · Examination of Repairs · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8291908
31 March 2025 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 8102275
22 April 2024 COI Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7899404
8 January 2024 Drydock Exam · Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7857549
18 May 2023 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7691480
30 March 2023 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7659602
22 March 2023 In-Service Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7654787
9 August 2022 Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7528678
6 January 2022 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7375642
5 January 2022 Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7376199
29 December 2021 Damage Survey
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7373406
9 August 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7281204
3 August 2020 Deficiency Check · Annual Inspection
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 7023116
15 January 2020 Drydock Exam · Examination of Repairs · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6889748
12 March 2019 Internal Structural Exam · COI Inspection · Deficiency Check · Examination of Repairs · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 6640718
1 August 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6498260
24 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6295493
20 October 2017 Internal Structural Exam · Administrative Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6291856
26 July 2017 Deficiency Check · DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6221359
23 June 2016 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5916987
22 June 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5916316
18 April 2016 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5856752

Deficiency record · 54

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 June 2026 Resolved
Visual alarm did not function for the lazarette and engine room bilge alarms. Repair to the satisfaction of the Marine Inspector. 46 CFR 182.530(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 9 June 2026
Resolution: Verified operational
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 June 2026 Resolved
Lagging on the generator exhaust piping has gaps exposing hot surfaces. Install lagging to the satisfaction of the Marine Inspector. 46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 1 July 2026
Resolution: lagging installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 June 2026 Resolved
Stowage of child life jackets on main deck not appropriately marked and separated from adult life jackets. Properly mark and stow child life jackets. 46 CFR 180.78(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 18 June 2026
Resolution: verified stowage and markings
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 2 June 2026 Resolved
Alcohol swabs on board are expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 July 2026
Resolved 1 July 2026
Resolution: Verified new swabs onboard
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 March 2025 Resolved
REPLACE TORN HOSE ON CO2 EXTINGUISHER IN ER
Condition: Unknown
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 7 April 2025
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 March 2025 Resolved
VESSEL MUST BE EQUIPPED W/ THREE NIGHT DISTRESS SIGNALS; THREE FLARES ARE EXPIRED.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2025
Resolved 7 April 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 April 2024 Resolved
Electrical equipment must be installed and maintained to protect personnel and the vessel from electrical hazards; there is a dead end wire in the A/C compartment that must be properly terminated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 May 2024
Resolved 24 April 2024
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 May 2023 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom; the existing waste receptacles are not of an approved typed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 23 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 May 2023 Resolved
Emergency exits used as a means of escape must be marked on both sides in 2 inch letters, "EMERGENCY EXIT, KEEP CLEAR"; the exits are not properly marked.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 23 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2023 Resolved
Cable runs must be installed with metal supports spaced no more than 24” apart; the cable runs in the fuel tank void are not properly supported due to modifications.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 18 May 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 April 2023 Resolved
Fuses must be of the cartridge type only and be UL listed in accordance with 46 CFR 183.380 (k) (1); the fuses installed in the main engines electrical feed from the ECM is are blade type fuses.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 May 2023
Resolved 18 May 2023
Resolution: Fuses have been replaced with UL 489 breakers.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
Drug testing background checks are not being conducted IAW 49 CFR 40.25.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
There is no alcohol testing device on board IAW 46 CFR 16.240.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
The EAP display with the hotline number is not displayed IAW 46 CFR 16.401.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
The supervisors have not recieved the one hour EAP supervisor training IAW 46 CFR 16.401.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
The list of covered employees was not available for verification IAW 46 CFR Part 16.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 April 2024
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 3 August 2020 Resolved
A vessel of at least 26 feet in length must be provided with a visual and audible alarm, at the operating station, which indicates high water level in required spaces; the bilge alarm for the A/C compartment is not operational due to a short or ground.
Action required: 10 - Deficiency Rectified
Due 15 September 2020
Resolved 3 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2020 Resolved
Each life buoy must be marked with Type II reflective material approved IAW 164.018; the life buoy is missing the reflective tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 15 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020 Resolved
Fuses must be of the cartridge type only and be listed by UL; the battery chargers and the electronic propulsion control system have non-approved type fuse installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 15 September 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 August 2020 Resolved
Twist on type connectors may not be used for facilitating a conductor splice unless installed IAW 183.340 (i) (1); the are numerous twist on type wire connectors under the bridge console.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 September 2020
Resolved 15 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 May 2019 Resolved
Each lifebuoy must be marked in block letters with the vessel name. Currently no name is on lifebuoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Name properly marked on 02 lifebouys.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 May 2019 Resolved
Stowage location of lifejackets shall be marked with appropriate size and qty. Current markings are not adequate.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Lifejacket stowage properly marked, all children relocated to upper deck.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 9 May 2019 Resolved
Vsl shall have installed audible and visual high level bilge alarms. Alarms are not labeled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: High level alarm panel properly labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 May 2019 Resolved
In systems where flexible hose are permitted to be clamped, clamps must not depend on spring tension. The new installation generator is relying on spring tension clamps for components of the fuel system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Spring clamps have been replaced with SS screw type clamps.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 9 May 2019 Resolved
Electrical installations shall be to the satisfaction of the [name withheld] all electrical panels have proper labeling for equipment installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: All panels are labeled properly.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 May 2019 Resolved
Navigation publications shall be provided onboard for the vsl route. Provide the following current pubs: tide/current tables, navigation rules, coast pilot, and light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Excerpts of publications for area of operation were onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 May 2019 Resolved
Training and drills shall be logged as required. Ensure all items are logged.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: A new logbook for the vessel has been started.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 May 2019 Resolved
An existing vsl must comply with the requirements of 183.420, navigation lights. Nav lights shall have 2 sources of power. The current nav anchor light is 110 volts. Provide two adequate sources of power of anchor light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Anchor light shifted over to 12 volts.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 9 May 2019 Resolved
conduct man overboard and fire drills with assigned crew in the presence of MI.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 May 2019
Resolution: Drills conducted with Capt and two crew.
Communications › Radio Communications › VHF Radiotelephone
Issued 31 July 2017 Resolved
Document daily radio checks IAW 47 CFR 80
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 24 October 2017
Resolution: Log updated to satisfaction of MI.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 31 July 2017 Resolved
Provide updated Coast Pilot and corrected charts for area of operation IAW 46 CFR 184.420
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 24 October 2017
Resolution: Coast pilot and charts updated to satisfaction of MI.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 31 July 2017 Resolved
Provide acceptable bracket for concession stand portable fire extinguisher IAW 46 CFR 181.30-5
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 10 August 2017
Resolution: Fire extinguisher was placed in an appropriate bracket.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 July 2017 Resolved
Secure refrigerator and sink to prevent movement in heavy seas IAW 46 CFR 184.220
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 10 August 2017
Resolution: Items were properly secured.
Lifesaving › Lifebuoys › Serviceable
Issued 31 July 2017 Resolved
Plug or replace life ring buoy per manufacturer's standards IAW 46 CFR 180.70
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 10 August 2017
Resolution: Ring buoy was fixed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 July 2017 Resolved
Secure life jacket stowage containers on upper deck IAW 46 CFR 176.800
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 10 August 2017
Resolution: Container was secured to vsl.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 31 July 2017 Resolved
Repack bulkhead opening between void and pump room and cap pump room to E-room conduit IAW 46 CFR 179.320
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 24 October 2017
Resolution: Bulkhead opening packed to satisfaction of MI.
Engineering › Fuel Oil Service System › Filter
Issued 31 July 2017 Resolved
Install missing drip pan flame screen on fuel filter IAW 46 CFR 182.455
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 24 October 2017
Resolution: Drip pan flame screen installed.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 31 July 2017 Resolved
Make all bulkheads vapor tight IAW 46 CFR 179.320
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 24 October 2017
Resolution: Bulkheads vapor tight to satisfaction of MI.
Electrical › Electrical Distribution System (service) › Cable
Issued 31 July 2017 Resolved
Secure cabling at 24" intevals with metal supports IAW 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 24 October 2017
Resolution: Cabling secured to satisfaction of MI.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 31 July 2017 Resolved
Re-attach forward hatch cover IAW 46 CFR 176.800
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 10 August 2017
Resolution: Hatch was attached.
Documentation › Markings/Placards › Warning Signs
Issued 31 July 2017 Resolved
Update signage to reflect 68 passenger allowed on upper deck per stability letter IAW 46 CFR 185.602
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2017
Resolved 10 August 2017
Resolution: Signage was posted.
Engineering › Fuel Oil Service System › Piping
Issued 24 May 2016 Resolved
Port side engine compartment fuel pipe unsecured.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Fuel pipe was secured properly.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 24 May 2016 Resolved
Port and starboard fuel vent flame screen is painted over
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Vent pipes cleaned.
Engineering › Bilge Water Management System › Manifold
Issued 24 May 2016 Resolved
Bilge manifold not labeled specifically for compartments
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Bilge manifold was properly labeled.
Engineering › Freshwater Generation System › Valve, Dump
Issued 24 May 2016 Resolved
Hot water heater pressure relief valve is rated for 150 psi
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Relief valve replaced with 75 psi valve.
Stability › Watertight Integrity › General
Issued 24 May 2016 Resolved
Starboard shaft packing requires tightening
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Shaft packing was adjusted underway and not leaking in port as before.
Communications › Radio Communications › VHF Radiotelephone
Issued 24 May 2016 Resolved
VHF radios do not have DSC capability
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: New radio installed with DSC and safety cert issued.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 24 May 2016 Resolved
Aft galley window is broken.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Windows replaced.
Electrical › Electric Generation Source (service) › Panelboard
Issued 24 May 2016 Resolved
Circuit breaker panel not labeled appropriately
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Panel box labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 May 2016 Resolved
Dead end wiring found on top of canopy
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Wire was removed.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 24 May 2016 Resolved
Anchor does not have mousing on shackle to prevent backing out of screw
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Mousing added to anchor.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 24 May 2016 Resolved
Emergency instructions are required to be posted at operating station
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Emergency instructions posted near helm.
Navigation › Piloting/Steering › Marine Charts
Issued 24 May 2016 Resolved
Vessel required to have updated publications.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Pubs updated.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 24 May 2016 Resolved
Update drug consortium roster and post EAP hotline.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 June 2016
Resolved 22 June 2016
Resolution: Drug roster sheet updated with all crew.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.