MAD GAFFER II

MAD GAFFER II is a 1983 passenger vessel (inspected). The Coast Guard has recorded 69 inspections since 1985, most recently in March 2026, along with 76 deficiencies and 1 casualty investigation in 2015.

Records from 1985 to 2026. Most recent: inspection, 19 March 2026.

Built
1983
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB3728
Flag
UNITED STATES
366890650
Maury page id
psix-55243

Inspections, by type

…with no type recorded5
Years with a record 40 calendar years (1985–2026)
The 69 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)35.5 ft × 12.0 ft × 6.0 ft
Registered tonnagegross 17 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHENRIQUES BOAT WORKS,INC. · BAYVILLE NJ, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 19 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it17 - Simplified, Gross Ton
14 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDB3728MMSI 366890650 · active · compulsorily equipped · granted 22 February 2023, expires 22 April 2033
WCW9566MMSI 368005000 · expired · compulsorily equipped · granted 27 November 1996, cancelled 27 January 2007 · licensed under a name not among this hull’s recorded names (not shown)
WCO7679MMSI not assigned · expired · compulsorily equipped · granted 15 November 1994, cancelled 15 January 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 69

19 March 2026 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8303611
25 August 2025 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8217904
6 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8087535
25 March 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7884364
27 September 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7799482
20 March 2023 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7653399
21 June 2022 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7482599
5 October 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7326869
21 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7233831
27 May 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6961669
11 March 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6921344
14 January 2020 Type not recorded
No type recorded · USCGC SHRIKE (WPB 87342) · USCG Northeast District (CGD-NE) · Activity 6890538
20 March 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6646460
6 March 2018 Hull Examination · Administrative Inspection · COI Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6340430
30 March 2017 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6114149
26 June 2016 Type not recorded
No type recorded · Station (Small) Shark River · USCG East District (CGD-E) · Activity 5925409
30 March 2016 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5843522
16 March 2016 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5834680
12 November 2015 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 5762285
11 November 2015 Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5762125
11 November 2015 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 5762128
21 March 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4818396
12 March 2014 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4813955
1 December 2011 Administrative Inspection · Simplified Stability Test
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199074
26 March 2010 DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3703514
10 March 2010 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3692013
17 March 2009 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3435452
8 April 2008 Hull Examination · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3178905
20 March 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2890384
7 June 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2672964
7 March 2006 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2597556
28 March 2005 Annual Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2319269
3 August 2004 Administrative Inspection
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2155393
14 April 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2044142
23 March 2004 Internal Structural Exam · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2030328
29 May 2003 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1802972
13 August 2002 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1661045
9 May 2002 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1614983
30 August 2001 Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1070319
1 June 2000 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1050697
25 May 2000 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1056573
29 June 1999 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1113801
28 July 1998 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 796157
28 April 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789752
29 May 1997 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 773948
16 July 1996 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1411341
25 April 1996 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1085861
10 July 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 876104
10 August 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1173029
1 August 1994 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 863633
21 July 1994 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 864594
6 April 1994 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1166084
22 July 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1159088
5 October 1992 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 936644
15 July 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 955917
22 April 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1260860
21 June 1991 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 903137
27 September 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1212416
21 June 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 902925
9 June 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1346570
18 May 1989 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 896111
29 March 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 897635
14 July 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1045038
14 July 1987 Deficiency Check · Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1326142
26 June 1987 Deficiency Check · Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1326134
16 July 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1298194
17 June 1986 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 990660
5 June 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 996114
12 March 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 977872

Deficiency record · 76

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 March 2025 Resolved
A submersible electric bilge pump may be used as a power bilge pump provided that the pump is permanently mounted. The aft-most bilge pump was not permanently mounted. Mount submersible bilge pump to the bilge so that it cannot be moved from its location during operation.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2025
Resolved 12 March 2025
Resolution: Provided proof of mounted bilge pump
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 March 2025 Resolved
All cable and wires must be installed with metal supports spaced not more than 24 inches apart, and in such a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to the bundling or retention of multiple cable installations, and not used as a means of support. Various wire and cable installations throughout the engine space and bilge voids were supported by plastic tie wraps and had abandoned electrical cabling integrated into the serviceable wiring. Remove all abandoned wiring and plastic tie wraps and fasten loose wiring with metal supports.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2025
Resolved 8 March 2025
Resolution: Abandoned wires were removed. Existing wire and cable installations throughout the engine space and bilge voids were cleaned up and properly bundled.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 6 March 2025 Resolved
The float-free link required by §180.130(a)(1) must be: Certified to meet §160.073 in subchapter Q of this chapter and of proper strength for the size of the life float or buoyant apparatus as indicated on its identification tag. The float free link installed for both life floats does not bear an identification tag, so the breaking strength cannot be confirmed. Replace the float free link with one of proper size and strength as specified by subchapter Q of 46 CFR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2025
Resolved 12 March 2025
Resolution: Provided proof of updated weak link
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 March 2024 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. The enclosure in the tank space had a broken cover with exposed wire connections.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2024
Resolved 25 March 2024
Resolution: Enlosure cover replaced to the satisfaction of the attending [name withheld] uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 March 2023 Resolved
An inspection for renewal of a Certificate of Inspection is conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It normally includes inspection and testing of the structure, machinery, equipment, and on a sailing vessel, rigging and sails. The owner or operator must conduct all tests as required by the OCMI, and make the vessel available for all specific inspections and drills required by subpart H of this part. In addition, the OCMI may require the vessel to get underway. Found excessive oil in engine room bilge. Discrepancy written and 14 days given to clean it up. 46 CFR 176.404
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2023
Resolved 21 March 2023
Resolution: Vessel owner provided photographic proof depicting clean, dry bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2022 Resolved
Bilge pump in tank space was inop. Proper operation was witnessed prior to end of inspection. Cleared on the spot. 46 CFR 182.500
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 21 June 2022
Resolution: Cleared on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 June 2021 Resolved
Wire splices made with crimpers in lazarette and engine space need to be made in an enclosure. Enclosure in tank space needs to be secured permenantly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 6 July 2021
Resolution: Received photos of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 June 2021 Resolved
Electrical submersible pump in lazarette space needs to be permenantly secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 6 July 2021
Resolution: Photographs of repairs received.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 21 June 2021 Resolved
Vessel name needs to be marked on both sides of the bow. Letters not less than 4 inches in height.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 July 2021
Resolved 6 July 2021
Resolution: Photographs of vessel name received.
Electrical › Electric Supply System (service) › Cable
Issued 26 March 2018 Resolved
Install metal supports on cable runs at spacing no greater than 24 inches.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 29 March 2018
Resolution: Received e-mail with photo that vessel owner installed metal supports at locations identified during COI inspection.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 March 2016 Resolved
Remove dead end wiring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 31 March 2016
Resolution: Vessel removed dead end wiring.
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 31 March 2016 Resolved
Post proper emergency instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 31 March 2016
Resolution: Vessel posted emergency instructions.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 March 2016 Resolved
Obtain required ammonia inhalants.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 31 March 2016
Resolution: Vessel provided receipt (and later picture) of purchase of ammonia inhalants.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 31 March 2016 Resolved
Maintain company drug policy onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 April 2016
Resolved 31 March 2016
Resolution: Vessel provided picture of posted company drug policy.
Construction/Loadline › Hull › Hull Plating
Issued 12 November 2015 Resolved
Vessel had run aground on rocks. Vessel was found to have four (04) spots on the stbd side of mono-hull that require permanent repair. Two spots where on the keel and two others where on the stbd chine. Repair must be made with only Epoxy resin and the area of repair must be tapered back with a 1 to 12 or more scarf ratio. Require repair proposal to the the satisfaction of attending MI.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 November 2015
Resolved 18 November 2015
Resolution: All repairs were satisfactorily completed.
Stability › Intact Righting Energy › General
Issued 1 December 2011 Resolved
The Coast Guard amended its regulations governing the maximum weight and the number of passengers that may safely be permitted on board a passenger vessel based on a new Assumed Average Weight Per Passenger (AAWPP) of 185 lbs per person. Based on the new AAWPP your vessel has been restricted to the following passenger count of 12 passengers and 02 crew.
Action required: 705 - Other - as specified
Resolved 8 December 2011
Resolution: Satisfactorily conducted a simplified stability test on 08 Dec 2011
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 22 March 2007 Resolved
Demonstrate proper operation of fixed fire fighting system to include automatic and override discharge functions prior to carrying passenger for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 March 2007
Resolution: Tested automatic and override functions of fixed fire fighting system. All Sat.
Fire Fighting › Fixed Fire Detection System › Control Panel
Issued 28 March 2005 Resolved
Prove proper operation of fixed firefighting system release indication (visual/audible).
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2005
Resolved 5 April 2005
Resolution: Re-tested shutdown of machinery utilizing fire system. Verified shutdowns and visual/audible alarms.
Lifesaving › Buoyant Apparatus › Marking
Issued 28 March 2005 Resolved
Stencil 4 pers. L/F with capacity.
Due 7 April 2005
Resolved 5 April 2005
Resolution: verified stencil.
Communications › Radio Communications › EPIRB
Issued 28 March 2005 Resolved
Provide current hydrostatic release for EPIRB. Vessel restricted to NMT 03 NM from shore.
Due 7 April 2005
Resolved 5 April 2005
Resolution: Verified installation of current EPIRB hydrostatic release.
Communications › Alarms/Indicators › Bilge Alarm
Issued 28 March 2005 Resolved
Provide bilge pump auto indicator lights for each installed bilge pump.
Due 7 April 2005
Resolved 5 April 2005
Resolution: Verified installation and operation of bilge pump visual indicators for auto mode.
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 May 2003 Resolved
Provide proper eye wash for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Unknown
Due 29 June 2003
Resolved 17 June 2003
Resolution: Proper eyewash provided.
Fire Fighting › Emergency Fire Pumps
Issued 29 May 2003 Resolved
Provide and label proper fire buckets. LEGACY COMPONENT DESC: Capacity
Condition: Unknown
Due 29 June 2003
Resolved 17 June 2003
Resolution: Proper fire buckets provided.
Fire Fighting › Remote Fuel Shutoff
Issued 29 May 2003 Resolved
Provide proper label for emergency fuel shut off.
Condition: Improper/Lack of Maintenance
Due 29 June 2003
Resolved 17 June 2003
Resolution: Fuel shutoff placard installed on vessel.
Construction/Loadline › Penetrations
Issued 29 May 2003 Resolved
Ensure all thru bulkhead fittings are water-tight. LEGACY COMPONENT DESC: Gasket
Condition: Placed in Improper Service
Due 29 June 2003
Resolved 17 June 2003
Resolution: Thru bulkhead fittings made water tight.
Lifesaving › Buoyant Apparatus
Issued 29 May 2003 Resolved
Change out tape on life float grab lines.
Condition: Placed in Improper Service
Due 29 June 2003
Resolved 17 June 2003
Resolution: Tape on life float grab lines replaced.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 May 2003 Resolved
Raw water cooling discharge missing double hose clamps. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper Installation
Due 29 June 2003
Resolved 17 June 2003
Resolution: Double hose clamps provided.
Engineering › Bilge Water Management System
Issued 29 May 2003 Resolved
Bilge pumps not properly UL listed. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2003
Resolution: Proper UL listed pumps placed in all compartments of vessel.
Construction/Loadline › Penetrations › Gasket
Issued 29 May 2003 Resolved
Provide proper water tight closure for hawspipe arangement.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2003
Resolution: Proper closures provided for opening on bow for anchor line.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 May 2003 Resolved
Provide proof af all employees on vessel enrolled in company managed drug testing program.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 June 2003
Resolution: Proof of proper enrolement provided and submitted with casework.
Documentation
Issued 30 August 2001 Resolved
PROVIDE PROOF OF VESSEL DOCUMENTATION.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Fire Fighting
Issued 30 August 2001 Resolved
PROVIDE PROOF OF CERTIFIED TECH REPORT FOR VESSEL FIXED FIRE FIGHTING SYSTEM AND ALL PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Navigation
Issued 30 August 2001 Resolved
PROVIDE PROOF OF PROPER OPERATION OF VESSEL HORN.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Navigation
Issued 30 August 2001 Resolved
PROVE OPERATION OF VESSEL STERN LIGHT.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Accommodation/Occupational Safety
Issued 30 August 2001 Resolved
REFASTEN HAND RAILS ON BOW FOR BOTH PORT AND STBD SIDES.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Lifesaving
Issued 30 August 2001 Resolved
REPLACE REFLECTIVE TAPE AND CONNECT WEAK LINK ON VESSEL 10 PERSON LIFEFLOAT.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Lifesaving
Issued 30 August 2001 Resolved
PROVIDE PROOF OF EPRIB REGISTRATION.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Electrical
Issued 1 June 2000 Resolved
ELECTRICAL BOX LOCATED ON THE ENGINE (LOWER, STBD SIDE, AFT) WAS IMPROPERLYREPAIRED WITH DUCT TAPE.
Condition: Unknown
Due 16 June 2000
Resolved 21 November 2000
Lifesaving
Issued 29 May 1997 Resolved
PROVIDE APPROVED FIRST AID KIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Lifesaving
Issued 29 May 1997 Resolved
PROVIDE NEW BATTERY FOR FLOAT LIGHTS.
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Lifesaving
Issued 29 May 1997 Resolved
PROVIDE RETRO TAPE ON LIFERING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Fire Fighting
Issued 29 May 1997 Resolved
PROVIDE FIRE HOSE AND NOZZLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Lifesaving
Issued 29 May 1997 Resolved
PROVIDE APPROVED CAT1 406 EPIRB.
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Documentation
Issued 29 May 1997 Resolved
PROVIDE PROPER PUBLICATIONS.
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Fire Fighting
Issued 29 May 1997 Resolved
PROVIDE ONE BII FIRE EXT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Lifesaving
Issued 29 May 1997 Resolved
MARK "DISTRESS SIGNALS" ON FLARE BOX._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Lifesaving
Issued 29 May 1997 Resolved
PROVIDE 2 ADULT PFD'S._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Lifesaving
Issued 29 May 1997 Resolved
PROVIDE NAME OF VESSEL ON L/F._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 June 1997
Resolved 23 June 1997
Construction/Loadline
Issued 25 April 1996 Resolved
VESSEL IS NOT TO CARRY PASSENGERS UNTIL DRYDOCK IS SATISFACTORILY COMPLETED.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Documentation
Issued 1 August 1994 Resolved
PRIOR TO OPERATING THE VESSEL, PROVIDE AN OPERATOR WITH A VALID FCC_x001C_ OPERATOR'S PERMIT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 August 1994
Resolved 1 August 1994
Documentation
Issued 21 July 1994 Resolved
PROVIDE A VALID FCC STATION LICENSE AND A VALID FCC OPERATOR'S PERMIT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Lifesaving
Issued 21 July 1994 Resolved
MARK THE ADULT LIFE PRESERVERS WITH THE VESSEL NAME (MAKE LEGIBLE).
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Fire Fighting
Issued 22 July 1993 Resolved
PROVIDE PROFESSIONAL SERVICING OF BOTH B-II PORTABLE FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Documentation
Issued 22 July 1993 Resolved
PROVIDE EVIDENCE THAT THE CERTIFICATE OF DOCUMENTATION HAS BEEN RENEWED. CORRECT PRIOR TO CARRYING PASSENGERS FOR HIRE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Lifesaving
Issued 22 July 1993 Resolved
REPAIR THE LIFEFLOAT WATERLIGHT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Deck/Cargo
Issued 22 July 1993 Resolved
DEMONSTRATE OPERATION OF THE ANCHOR WINDLASS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Lifesaving
Issued 22 July 1993 Resolved
RENEW THE SEAPAINTER ON THE LIFEFLOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 August 1993
Resolved 9 August 1993
Lifesaving
Issued 15 July 1992 Resolved
PROVIDE 1 CHILD TYPE I USCG APPROVED LIFE PRESERVER. VESSEL RESTRICTED TO 1 CHILD UNTIL ADDITIONAL CHILD PFD'S PROVIDEED.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Navigation
Issued 15 July 1992 Resolved
PROVIDE UPDATED LIGHT LIST FOR AREA OF OPERATION.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Navigation
Issued 15 July 1992 Resolved
Provide updated Navigation Rules Inland.
Condition: Unknown
Due 15 July 1992
Resolved 15 July 1992
Construction/Loadline
Issued 22 April 1992 Resolved
REPAIR HOLE IN STEM AT WATERLINE PRIOR TO CARRYING PASSENGERS. HOLE IS APPROXIMATELY 1/4" IN DIAMETER._x001C_
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Construction/Loadline
Issued 22 April 1992 Resolved
REPAIR DETERIORATED AREA OF HULL COATING LOCATED AT CHINE PORTSIDE AFT PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Engineering
Issued 9 June 1989 Resolved
PROVIDE (1) ONE HEAT DEFLECTOR SHIELD FOR MDE'S FUEL SYSTEM, WHERE MISSING.ORIGINAL COMPLIANCE DATE IS 10JUL89.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Documentation
Issued 9 June 1989 Resolved
PROVIDE A VALID FCC SAFETY CERTIFICATE PRESENTLY NOT ONBOARD. THE VESSEL IS RESTRICTED TO NOT MORE THAN 1000 FEET FROM SHORE, UNTIL FCC SAFETY CERTIFICATE IS ONBOARD. ORIGINAL COMPLIANCE DATE IS 10JUL89.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Navigation
Issued 9 June 1989 Resolved
PROVIDE THE MOST RECENT COPIES OF THE TIDE TABLE, TIDAL CURRENT TABLE, AND NOTICE TO MARINERS PRESENTLY NOT ONBOARD. ORIGINAL COMPLIANCE DATE IS 10JUL89.
Condition: Unknown
Due 9 June 1989
Resolved 9 June 1989
Construction/Loadline
Issued 29 March 1989 Resolved
MAKE PERMANENT REPAIRS TO TWO (2) BLISTERS PORT SIDE BOTTOM HULL.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Construction/Loadline
Issued 29 March 1989 Resolved
REMOVE ONE (1) BOTTOM HULL STRAINER FOR THE INSPECTION OF THE THROUGH HULL FITTING.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Engineering
Issued 29 March 1989 Resolved
RENEW THE TAILSHAFT RUBBER CUTLESS BEARING, WHERE WORN MORE THAN FIFTY PERCENT.
Condition: Unknown
Due 29 March 1989
Resolved 29 March 1989
Lifesaving
Issued 14 July 1987 Resolved
RENEW THE LIFEFLOAT GRABLINES AND MAKE REPAIRS TO THE LIFEFLOATS OUTER PROTECTIVE COATING WHERE PEELED AWAY. REPAIRS ARE TO BE COMPLETED PRIOR TO 01AUG87.
Condition: Unknown
Due 14 July 1987
Resolved 14 July 1987
Lifesaving
Issued 26 June 1987 Resolved
PROVIDE A CG APPROVED FLOAT FREE LINK FOR THE LIFE FLOAT.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987
Accommodation/Occupational Safety
Issued 26 June 1987 Resolved
PROVIDE A DOUBLE CLAMP ON THE TOILET INTAKE LINE IN WAY OF THE INTAKE VALVE.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987
Lifesaving
Issued 26 June 1987 Resolved
RENEW, AS NECESSARY, THE REFLECTING TAPE ON THE LIFE JACKETS.
Condition: Unknown
Due 26 June 1987
Resolved 26 June 1987
Lifesaving
Issued 17 June 1986 Resolved
STENCIL THE LIFEFLOAT WITH ITS CAPACITY.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Lifesaving
Issued 17 June 1986 Resolved
PROVIDE ON BOARD 7 ADULT PFD'S. UNTIL THIS REQUIREMENT IS MET, A MAXIMUM OF 10 PERSONS MAY BE CARRIED.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Navigation
Issued 17 June 1986 Resolved
PROVIDE ON BOARD THE CURRENT EDITION OF RULES OF THE ROAD.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986
Navigation
Issued 17 June 1986 Resolved
PROVIDE ON BOARD THE CURRENT EDITION OF CHART #12214.
Condition: Unknown
Due 17 June 1986
Resolved 17 June 1986

Casualty record · 1

11 November 2015Routine · role: Involved in a Marine Casualty · activity 5762128
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record