MAURY USCG vessel records Sign in
← All vessels

FALCON

FALCON is a 1974 passenger vessel (inspected). The Coast Guard has recorded 67 inspections since 1983, most recently in November 2025, along with 42 deficiencies.

Records from 1983 to 2025. Most recent: inspection, 19 November 2025.

Built
1974
Last inspected
19 November 2025
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-55244

Inspections, by type

…with no type recorded3
Years with a record 40 calendar years (1983–2025)
The 67 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 67

19 November 2025 Drydock Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8269834
3 January 2025 Annual Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8051179
1 November 2023 Annual Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7924323
11 May 2023 Internal Structural Exam · Examination of Repairs · Drydock Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7684435
10 November 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7584152
2 June 2022 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7460434
17 November 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7351836
23 June 2021 COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7225144
25 May 2021 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7206475
9 December 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7117470
5 December 2019 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6867308
30 August 2019 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6824381
17 June 2019 Administrative Inspection · Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6759841
30 October 2018 Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6753437
4 December 2017 Examination of Repairs · Administrative Inspection · Drydock Exam · Annual Inspection · DAPI Audit · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6408009
5 June 2017 Administrative Inspection · DAPI Audit · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6155974
17 November 2016 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6155497
16 November 2015 Internal Structural Exam · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5849267
9 May 2014 Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4873005
7 May 2012 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4311890
7 December 2011 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4210936
1 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199544
9 December 2010 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3907655
14 December 2009 Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3650137
12 December 2008 Annual Inspection · Hull Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3378895
26 November 2008 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3369815
6 December 2007 Hull Examination · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3204700
20 June 2007 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2968243
31 January 2006 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2576819
7 December 2005 Hull Examination · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2547137
2 June 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2384013
6 December 2004 Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2329540
24 November 2003 Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2029070
24 June 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1833290
31 March 2003 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1789815
31 January 2002 Hull Examination · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1483042
3 May 2001 Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1059058
5 June 2000 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 818672
17 May 2000 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 817464
29 April 1999 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1386493
27 April 1998 Hull Examination · COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1453479
9 May 1997 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1467012
28 June 1996 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1390319
19 June 1995 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 878497
1 May 1995 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 855456
14 April 1995 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1360070
11 April 1994 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 857403
25 March 1994 Examination of Repairs
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 856021
16 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1165208
10 March 1994 Examination of Repairs
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1354608
6 December 1993 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1468304
23 June 1993 Drydock Extension
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1152733
15 May 1993 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1444733
15 May 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 946141
16 March 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 946755
11 March 1991 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1230112
29 October 1990 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1233949
17 May 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1217270
6 September 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 998920
17 May 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1040348
23 March 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1031050
25 May 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 887611
14 September 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1313158
26 May 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1327991
29 May 1986 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306644
30 May 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982959
2 June 1983 COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 988414

Deficiency record · 42

02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 5 December 2019 Resolved
Replace bottom planks #6 and #7 from the bow. -46 CFR 176.610
Action required: 705 - Other - as specified
Due 19 December 2019
Resolved 25 May 2021
Resolution: Mealanie Morrsion sent photos clearing all open defs
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 29 July 2019 Resolved
A power-driven fire pump shall be installed on each mechanically propelled vessel of not more than 65 feet in length which is a ferry vessel or which is permitted to carry more than 49 passengers. The FALCON does not have an installed power-driven fire pump to meet this regulation. The vessel must install a power-driven fire pump and related equipment to meet the requirements of 46 CFR 181 Subpart C for a new installation on an existing vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2019
Resolved 19 December 2019
Resolution: Vessel granted Special Consideration to continue operating without a power-driven fire pump provided it carries one additional 40-B:C portable fire extinguisher in the vicinity of the machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 July 2019 Resolved
A fixed power bilge pump shall be installed on each mechanically propelled vessel of not more than 65 feet in length which is a ferry vessel or which is permitted to carry more than 49 passengers. The FALCON does not have an installed fixed power bilge pump to meet this regulation. The vessel must install a power-driven fire pump and related equipment to meet the requirements of 46 CFR 182 Subpart E for a new installation on an existing vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 August 2019
Resolved 19 December 2019
Resolution: Vessel granted Special Consideration to operate with its current arrangement of two electric submersible bilge pumps in place of a fixed power bilge pump.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 June 2019 Resolved
Provide at least 60 minutes of training annually to individuals in supervisory positions of the effects and consequences of drug and alcohol use and how to identify individuals abusing alcohol or drugs. Document training.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 July 2019
Resolution: Vessel representative provide 60 minutes of DAPI training to individuals in supervisory positions.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 5 June 2017 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 23 June 2017
Resolution: Received copy of employee enrollment list.
Lifesaving › Lifebuoys › Quantity
Issued 5 June 2017 Resolved
Provide one life ring buoy designated for the flat (02 total on the ferry).
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 23 June 2017
Resolution: Received photo of new/additional ring life buoy.
Communications › Alarms/Indicators › High Water Alarm
Issued 5 June 2017 Resolved
Visual indicator for bilge high level alarm is always on. Prove proper operation of high level alarm during activation only.
Action required: 705 - Other - as specified
Due 5 July 2017
Resolved 23 June 2017
Resolution: Received photo of unlit visual indicator.
Engineering › Bilge Water Management System › Pump
Issued 7 May 2012 Resolved
Repair/Replace inoprable electrical bilge pump in starboard side of engine room.
Due 6 June 2012
Resolved 14 May 2012
Resolution: [name withheld] attended vessel and winessed successful operation of bilge pump in engine room.
Stability › Watertight Integrity › General
Issued 20 March 2012 Resolved
Vessel must complete satisfactory underway checkride prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 7 May 2012
Resolution: Completed U/W check ride accompanied by [name withheld] & [name withheld]
Stability › Intact Righting Energy › General
Issued 1 December 2011 Resolved
Based on the new AAWPP your vessel has been restricted to the following passenger count: 21passengers 2 crew If you have any questions regarding the new passenger count permitted on your vessel please contact [name withheld] at [phone withheld].
Action required: 705 - Other - as specified
Resolved 7 May 2012
Resolution: Vessel FALCON is exempted from stablitity regulations as per 46 CFR 178.320 (c).
Construction/Loadline › Hull › Side Shell
Issued 14 December 2009 Resolved
Plank #1 from the bow is rotted. Forward transverse member, slightly above plank #1 is rotted. Starboard side, 5ft aft, longitudinal beam is rotted. Directly above plank #10, starboard side, has significant rot. Port side, longitudinal beam, 15 foot section from the bow moving aft is rotted. One paddle wheel is fractured and needs to be repaired.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2010
Resolution: All areas in need of repair above have been repaired. All Sat. Repairs have been attested to.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 20 June 2007 Resolved
Properly rep[air the H/L alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 July 2007
Construction/Loadline › Hull › Hull Plating
Issued 7 December 2005 Resolved
Conduct underway hull inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2006
Resolved 27 April 2006
Resolution: Inspected sat.
Engineering › Fuel Oil Service System › Hose
Issued 7 December 2005 Resolved
Reclamp gasoline filter with double hose clamps & prove USCG A1 fuel hose.
Action required: 705 - Other - as specified
Due 27 April 2006
Resolved 25 May 2006
Resolution: Installed CG-A1 hose and double clamped all sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 7 December 2005 Resolved
Provide means ashore for keeping passenger count.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 25 May 2006
Resolution: Mail box placed on both shores for passenger count.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 December 2005 Resolved
Configure nav lts so anchor & running lights do not iluminate at the same time.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 25 May 2006
Resolution: Witnessed independant test of Nav lts & anchor lts, all sat.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 December 2005 Resolved
Prove hydrostatic test date of B-I & B-II extinguishers.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 25 May 2006
Resolution: Installed new B-I and replaced B-II with original that was hydro tested.
Documentation › Markings/Placards › Garbage Placard
Issued 7 December 2005 Resolved
Provide garbage placard.
Action required: 705 - Other - as specified
Due 27 May 2006
Resolved 25 May 2006
Resolution: Installed placard, all sat.
Construction/Loadline › Hull › Bottom Plating
Issued 17 June 2005 Resolved
Do not carry passengers proir to a Coast Guard Inspection of the repair of the three broken planks and the hull.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2006
Resolution: Vessel completed sat hull exam.
Construction/Loadline › Hull › Hull Plating
Issued 31 January 2002 Resolved
Prior to placing vessel in passenger service, carrying passengers for hire, provide vessel for operational tests to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 31 May 2002
Resolved 1 July 2002
Resolution: Examined the vessel in the water, no leaks noted.
Engineering
Issued 3 May 2001 Resolved
PROVIDE VESSEL FOR OPERATIONAL TEST OF ITS PROPULSION ENGINE.
Condition: Unknown
Due 30 May 2001
Resolved 18 May 2001
Construction/Loadline
Issued 17 May 2000 Resolved
BOTTOM CROSS PLANKS NUMBERS 8,34,35,66 AND 67 NUMBERED FROM BOW TO STERN REQUIRE REPLACMENT.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Lifesaving
Issued 17 May 2000 Resolved
PROVIDE REPLACEMENT WATERLIGHT FOR RING LIFE BUOY.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Engineering
Issued 17 May 2000 Resolved
PADDLE WHEEL REPAIRS TO REPLACE 1 BROKEN BUCKET.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Navigation
Issued 17 May 2000 Resolved
TWO RUDDER BOARDS TO BE REPLACED.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Documentation
Issued 1 May 1995 Resolved
PROVIDE CHEMICAL DRUG TESTING POLICY AND RANDOM TESTING PROCEDURES IN WRITING. IDENTIFY HOW RANDOM SELECTION OF EMPLOYEES REQUIRED TO BE TESTED UNDER 46 CFR 16.230 IS CONDUCTED USING A SCIENTIFICALLY VALID METHOD.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Lifesaving
Issued 1 May 1995 Resolved
PRIOR TO CARRYING MORE THAN 44 TOTAL PERSONS ON THE GREY FLAT AND THE FALCON WHILE THEY ARE OPERATED TOGETHER, PROVIDE 12 ADDITIONAL USCG APPROVED TYPE I OR II ADULT-SIZE LIFE PRESERVERS.
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Navigation
Issued 14 April 1995 Resolved
REPLACED LOWER RUDDER BOARD, APPROX 1" THICK, 12" WIDE, 5 FT LONG.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Engineering
Issued 14 April 1995 Resolved
CROPPED OUT ROT AND SISTERED JACKSHAFT SUPPORT (JACKSHAFT BASE) ON STBD SIDE WITH YELLOW PINE APPROX 2 FT X 4 FT, 2" THICK.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Construction/Loadline
Issued 14 April 1995 Resolved
COUNTING FROM BOW TO STERN REPLACED FOLLOWING BOTTOM PLANKS WITH 2 3/4" YELLOW PINE PLANKS FASTENED WITH 6" 60 PENNY NAILS: #1,2,7,8,9,19,33,34,35,36,37,38,39,40,42,43,44,45.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Construction/Loadline
Issued 14 April 1995 Resolved
REFASTENED FOLLOWING YELLOW PINE BOTTOM PLANKS COUNTING FROM BOW TO STERN WITH 6" LONG 60 PENNY NAILS: #10, #11, #12.
Condition: Unknown
Due 17 April 1995
Resolved 17 April 1995
Construction/Loadline
Issued 14 April 1995 Resolved
PRIOR TO CARRYING PASSENGERS, PROVE INTEGRITY OF THE VESSEL UNDERWAY, TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 April 1995
Resolved 14 April 1995
Construction/Loadline
Issued 6 December 1993 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE MAKE PERMANENT REPAIRS TO VESSEL'S BOTTOM PLANKING AS MARKED FOR REPLACEMENT & AS DISCUSSED WITH OWNER REP. ALL REPAIRS SHALL BE MADE BACK TO ORIGINAL AND SHALL BE ACCOMPLISHED TO THESATISFACTION OF THE COGNIZANT OCMI._x001C_
Condition: Unknown
Due 6 December 1993
Resolved 6 December 1993
Construction/Loadline
Issued 11 March 1991 Resolved
D1-COUNTING FROM STERN TO FWD REPLACE #9 BOTTOM PLANK.
Condition: Unknown
Due 11 March 1991
Resolved 11 March 1991
Lifesaving
Issued 17 May 1990 Resolved
D1-PROVIDE RETROREFLECTIVE MATERIAL TO EACH LIFE PRESERVERS THE VESSEL IS REQUIRED TO DO 1/3 OF THE TOTAL LIFE PRESERVERS EACH YEAR TILL ALL LIFE PRESERVERS ARE DONE. MAY91-MAY92-MAY93
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Accommodation/Occupational Safety
Issued 6 September 1989 Resolved
THIS REQUIREMENT EXTENDS THE DEADLINE TO THE REQUIREMENT #4 ISSUED 17MAY89 TO REPAIR THE STOVE PIPE AND OVERHEAD PENETRATION UNTIL 30SEP89.
Condition: Unknown
Due 6 September 1989
Resolved 6 September 1989
Lifesaving
Issued 17 May 1989 Resolved
PROVIDE 6 NEW RED FLARES AND 6 ORANGE SMOKE AND 6 COMBINATION FLARES OF THE APPROVED TYPE. ORIGINAL COMPLIANCE DATE IS 01JUN89.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Lifesaving
Issued 17 May 1989 Resolved
PROVIDE APPROVED WATERTIGHT AND BRACKET FOR LIFERING BUOY. ORIGINAL COMPLIANCE DATE IS 01JUN89.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Fire Fighting
Issued 17 May 1989 Resolved
PAINT, STENCIL, AND HANG FIRE AX ON BULKHEAD TO ENGINE ROOM. ORIGINAL COMPLIANCE DATE IS 01JUN89.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Navigation
Issued 17 May 1989 Resolved
REPAIR THE PORT RUNNING LIGHT AND THE MASTERHEAD LIGHTS. ORIGINAL COMPLIANCE DATE IS 01JUN89.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Accommodation/Occupational Safety
Issued 17 May 1989 Resolved
PROVIDE NEW STOVE PIPE SECTION AND PENETRATION COLLAR OF CEILLING. ORIGINAL COMPLIANCE DATE IS 01JUN89.
Condition: Unknown
Due 17 May 1989
Resolved 17 May 1989
Lifesaving
Issued 26 May 1987 Resolved
PROVIDE TWELVE ADDITIONAL ADULT LIFEJACKETS FOR THE FALCON AND ITS BARGE TO PROVIDE A TOTAL OF 56 ADULT LIFEJACKETS.
Condition: Unknown
Due 26 May 1987
Resolved 26 May 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.