MAURY USCG vessel records Sign in
← All vessels

SURFACE INTERVAL

SURFACE INTERVAL is a 1946 passenger vessel (inspected). The Coast Guard has recorded 25 inspections since 1985, most recently in October 1994, along with 24 deficiencies.

Records from 1985 to 1994. Most recent: inspection, 31 October 1994.

Built
1946
Last inspected
31 October 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBT9089
Flag
UNITED STATES
—
Maury page id
psix-55247

Inspections, by type

…with no type recorded7
Years with a record 10 calendar years (1985–1994)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Gross Ton
9 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBT9089MMSI not assigned · expired · compulsorily equipped · granted 20 October 1994, cancelled 25 December 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

31 October 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1420920
2 May 1994 Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1171545
28 April 1993 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1358058
1 May 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1255977
1 May 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1256906
29 July 1991 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004844
23 April 1991 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 998820
17 January 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1216182
13 December 1990 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1239545
9 November 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1233576
24 April 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916790
14 August 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1206245
27 April 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1349832
17 April 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1041990
19 April 1988 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036047
14 March 1988 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029119
6 November 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330603
28 August 1987 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1319456
27 April 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026662
21 May 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 986709
22 April 1986 COI Inspection · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306691
3 March 1986 Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 998948
12 November 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991916
23 August 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294052
22 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 979884

Deficiency record · 24

Lifesaving
Issued 2 May 1994 Resolved
RENEW RETROREFLECTIVE TAPE ON TWELVE ADULT LIFEJACKETS.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Fire Fighting
Issued 2 May 1994 Resolved
ALL PORTABLE FIRE EXTINGUISHERS OUTDATED, HAVE ALL PORTABLE FIRE EXT. SERVICED BY A PROFFESIONAL SERVICING COMPANY.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Navigation
Issued 2 May 1994 Resolved
ALL CHARTS ARE OUTDATED, PROVIDE CURRENT CHARTS AS REQUIRED BY ROUTE ON THECOI.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Documentation
Issued 28 April 1993 Resolved
PROVIDE WRITTEN DOC. TO SHOW ALL VESSEL EMPLOYEES ARE IN COMPLIANCE WITH_x001C_ REQUIREMENTS OF 46CFR PARTS 4, 5 AND 16 PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Engineering
Issued 28 April 1993 Resolved
PROVIDE 30X30 MESH FLAME SCREENS FOR FUEL TANK VENTS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Accommodation/Occupational Safety
Issued 28 April 1993 Resolved
MAKE REPAIRS TO CLEANOUT HOSE ASSEMBLY WHERE IT IS WASTED AWAY FROM THE HOLDING TANK PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 28 April 1993 Resolved
REFASTEN DOUBLE PLANKED STERN WHERE REQUIRED, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 28 April 1993 Resolved
REPAIRS OR REPLACE BACK TO ORIGINAL 2" BARREL VALVE ON PORT SIDE OF MDE._x001C_ ITEM MUST BE CORRECTED AND ACCEPTED BY CG MARINE INSPECTOR PRIOR TO RELAUNCHING VESSEL.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 28 April 1993 Resolved
REPAIRS OR REPLACE BACK TO ORIGINAL 1-1/2" GATE VALVE FOUND PORT SIDE OF MDE. REPAIRS MUST BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 1 May 1992 Resolved
REMOVE AND REPLACE STANCHIN UNDER DECK SUPPORT FORWARD COMPARTMENT.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Construction/Loadline
Issued 1 May 1992 Resolved
REMOVE AND REPLACE AFT DECK IN WAY OF HATCH FOREWARD OF AFT STEERING, AN AREA APPROX. (4'X4').
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Navigation
Issued 1 May 1992 Resolved
PROVIDE CURRENT EDITION OF RULES OF ROAD PUBLICATION ONBOARD VESSEL.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 1 May 1992 Resolved
REPLACE (11) PERSON BOUYANT APPARATUS FOUND WATER SATURATED, WITH APPROVED TYPE BOUYANT APPARATUS OF SAME TYPE.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 1 May 1992 Resolved
REPLACE RING BUOY GRABLINES WITH FLOAT TYPE LINE.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Engineering
Issued 1 May 1992 Resolved
PROVIDE FLAME SCREENS IN FUEL TANK VENTS OF (30 X 30)SIZE MESH.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 1 May 1992 Resolved
REPLACE (03) ADULT LIFEJACKETS WITH APPROVED TYPE 1 , STENCILED WITH NAME OF VSL.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 23 April 1991 Resolved
PROVIDE ONE HAND HELD RED DISTRESS SIGNAL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Navigation
Issued 23 April 1991 Resolved
PROVIDE CURRENT/UPDATED NAVIGATION CHARTS FOR AREA OF OPERATION PRIOR TO OPERATION.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Construction/Loadline
Issued 9 November 1990 Resolved
REPAIR FLOOR LOCATED IN FOREWARD COMPARTMENT UNDER HEAD.
Condition: Unknown
Due 9 November 1990
Resolved 9 November 1990
Construction/Loadline
Issued 9 November 1990 Resolved
REPAIR FIRST FRAME PORT SIDE LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 9 November 1990
Resolved 9 November 1990
Electrical
Issued 27 April 1989 Resolved
INSTALL CIRCUIT PROTECTION ON TWO BILGE PUMPS.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Engineering
Issued 27 April 1989 Resolved
INSTALL HEAT DEFLECTOR SHIELD ON RACOR FUEL FILTER.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Construction/Loadline
Issued 6 November 1987 Resolved
REPLACE DECK PLANK IN WAY OF FORWARD DECK PORT SIDE JUST FORWARD OF COLLISION BULKHEAD.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Construction/Loadline
Issued 6 November 1987 Resolved
REPAIR SECOND GUNWALE SUPPORT AFT OF BOW ON STARBOARD SIDE MAIN DECK.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.