Records from 1985 to 1994. Most recent: inspection, 31 October 1994.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
31 October 1994
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1420920
2 May 1994
Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1171545
28 April 1993
Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1358058
1 May 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1255977
1 May 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1256906
29 July 1991
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1004844
23 April 1991
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 998820
17 January 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1216182
13 December 1990
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1239545
9 November 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1233576
24 April 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 916790
14 August 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1206245
27 April 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1349832
17 April 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1041990
19 April 1988
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036047
14 March 1988
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1029119
6 November 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1330603
28 August 1987
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1319456
27 April 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1026662
21 May 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 986709
22 April 1986
COI Inspection · Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306691
3 March 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 998948
12 November 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 991916
23 August 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1294052
22 April 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 979884
Lifesaving
Issued 2 May 1994
Resolved
RENEW RETROREFLECTIVE TAPE ON TWELVE ADULT LIFEJACKETS.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Fire Fighting
Issued 2 May 1994
Resolved
ALL PORTABLE FIRE EXTINGUISHERS OUTDATED, HAVE ALL PORTABLE FIRE EXT. SERVICED BY A PROFFESIONAL SERVICING COMPANY.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Navigation
Issued 2 May 1994
Resolved
ALL CHARTS ARE OUTDATED, PROVIDE CURRENT CHARTS AS REQUIRED BY ROUTE ON THECOI.
Condition: Unknown
Due 4 May 1994
Resolved 4 May 1994
Documentation
Issued 28 April 1993
Resolved
PROVIDE WRITTEN DOC. TO SHOW ALL VESSEL EMPLOYEES ARE IN COMPLIANCE WITH_x001C_ REQUIREMENTS OF 46CFR PARTS 4, 5 AND 16 PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Engineering
Issued 28 April 1993
Resolved
PROVIDE 30X30 MESH FLAME SCREENS FOR FUEL TANK VENTS PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Accommodation/Occupational Safety
Issued 28 April 1993
Resolved
MAKE REPAIRS TO CLEANOUT HOSE ASSEMBLY WHERE IT IS WASTED AWAY FROM THE HOLDING TANK PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 28 April 1993
Resolved
REFASTEN DOUBLE PLANKED STERN WHERE REQUIRED, PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 28 April 1993
Resolved
REPAIRS OR REPLACE BACK TO ORIGINAL 2" BARREL VALVE ON PORT SIDE OF MDE._x001C_ ITEM MUST BE CORRECTED AND ACCEPTED BY CG MARINE INSPECTOR PRIOR TO RELAUNCHING VESSEL.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 28 April 1993
Resolved
REPAIRS OR REPLACE BACK TO ORIGINAL 1-1/2" GATE VALVE FOUND PORT SIDE OF MDE. REPAIRS MUST BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 3 May 1993
Resolved 3 May 1993
Construction/Loadline
Issued 1 May 1992
Resolved
REMOVE AND REPLACE STANCHIN UNDER DECK SUPPORT FORWARD COMPARTMENT.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Construction/Loadline
Issued 1 May 1992
Resolved
REMOVE AND REPLACE AFT DECK IN WAY OF HATCH FOREWARD OF AFT STEERING, AN AREA APPROX. (4'X4').
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Navigation
Issued 1 May 1992
Resolved
PROVIDE CURRENT EDITION OF RULES OF ROAD PUBLICATION ONBOARD VESSEL.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 1 May 1992
Resolved
REPLACE (11) PERSON BOUYANT APPARATUS FOUND WATER SATURATED, WITH APPROVED TYPE BOUYANT APPARATUS OF SAME TYPE.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 1 May 1992
Resolved
REPLACE RING BUOY GRABLINES WITH FLOAT TYPE LINE.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Engineering
Issued 1 May 1992
Resolved
PROVIDE FLAME SCREENS IN FUEL TANK VENTS OF (30 X 30)SIZE MESH.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 1 May 1992
Resolved
REPLACE (03) ADULT LIFEJACKETS WITH APPROVED TYPE 1 , STENCILED WITH NAME OF VSL.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 23 April 1991
Resolved
PROVIDE ONE HAND HELD RED DISTRESS SIGNAL PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Navigation
Issued 23 April 1991
Resolved
PROVIDE CURRENT/UPDATED NAVIGATION CHARTS FOR AREA OF OPERATION PRIOR TO OPERATION.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Construction/Loadline
Issued 9 November 1990
Resolved
REPAIR FLOOR LOCATED IN FOREWARD COMPARTMENT UNDER HEAD.
Condition: Unknown
Due 9 November 1990
Resolved 9 November 1990
Construction/Loadline
Issued 9 November 1990
Resolved
REPAIR FIRST FRAME PORT SIDE LOCATED IN ENGINE ROOM.
Condition: Unknown
Due 9 November 1990
Resolved 9 November 1990
Electrical
Issued 27 April 1989
Resolved
INSTALL CIRCUIT PROTECTION ON TWO BILGE PUMPS.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Engineering
Issued 27 April 1989
Resolved
INSTALL HEAT DEFLECTOR SHIELD ON RACOR FUEL FILTER.
Condition: Unknown
Due 27 April 1989
Resolved 27 April 1989
Construction/Loadline
Issued 6 November 1987
Resolved
REPLACE DECK PLANK IN WAY OF FORWARD DECK PORT SIDE JUST FORWARD OF COLLISION BULKHEAD.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Construction/Loadline
Issued 6 November 1987
Resolved
REPAIR SECOND GUNWALE SUPPORT AFT OF BOW ON STARBOARD SIDE MAIN DECK.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987