MAURY USCG vessel records Sign in
← All vessels

QUEEN OF PEACE

QUEEN OF PEACE is a 1982 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1985, most recently in September 2024, along with 88 deficiencies — 1 with no resolution recorded —.

Records from 1985 to 2024. Most recent: inspection, 10 September 2024.

Built
1982
Last inspected
10 September 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD2704
Flag
UNITED STATES
367118740, 367641570 (licence lapsed)
Maury page id
psix-55261

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 34 calendar years (1985–2024)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.0 ft × 14.1 ft × 6.2 ft
Registered tonnagegross 25 / net 20
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderM W WILLIS&SON BOAT WORKS · MARSHALLBERG, NC, UNITED STATES · built 1982
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNIAGARA FALLS, NY
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 5 September 2025 · expires 30 September 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it25 - Simplified, Gross Ton
20 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH6783MMSI 367641570 · expired · compulsorily equipped · granted 24 September 2014, cancelled 7 December 2024
WDD2704MMSI 367118740 · expired · compulsorily equipped · granted 2 June 2006, cancelled 6 August 2016 · licensed under a name not among this hull’s recorded names (not shown)
WAA5936MMSI not assigned · expired · voluntarily equipped · granted 6 April 1994, cancelled 15 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 60

10 September 2024 Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8000144
5 September 2023 COI Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7785099
16 June 2023 Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7799441
18 August 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7558216
12 May 2021 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7195352
27 July 2020 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7018372
24 June 2019 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6720241
11 June 2018 DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6441611
19 May 2017 Deficiency Check · Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6149917
27 May 2016 DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5937601
5 May 2016 DAPI Audit · Administrative Inspection · Drydock Exam · Examination of Repairs · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5869478
23 October 2014 Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5010564
14 October 2014 Administrative Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5004559
28 September 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4160827
9 September 2011 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4140440
8 April 2009 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3474818
1 November 2007 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3109862
30 October 2007 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3088962
22 March 2007 In-Service Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2890517
3 October 2006 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2792776
31 May 2006 Initial Certification · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2663934
10 June 2004 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2094399
30 July 2003 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1859680
1 May 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1611447
12 April 2002 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1603179
22 June 2001 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1068658
30 April 2001 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1376571
17 May 2000 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1424924
20 April 2000 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 817517
9 March 2000 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 816016
6 May 1999 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 785733
30 April 1998 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1457562
13 November 1997 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1445283
24 April 1997 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1422828
13 March 1996 Deficiency Check · Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1380442
6 November 1995 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1468364
20 June 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 27527
28 March 1995 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1440915
20 April 1994 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 862116
30 March 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 862115
10 March 1994 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 856151
16 March 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1144217
30 March 1992 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1265825
17 March 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1412429
7 May 1991 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 900402
6 March 1991 Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 909881
7 August 1990 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1240810
10 May 1990 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 921613
19 July 1989 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1340280
30 April 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1036496
25 April 1989 COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1194541
1 March 1989 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1043978
18 May 1988 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1199223
18 May 1988 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1200067
22 February 1988 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1330870
19 May 1987 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1015864
2 June 1986 Credit Drydock
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1301648
9 May 1986 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1302813
20 June 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 984565
28 March 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 984187

Deficiency record · 88

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 September 2024 Resolved
Replaced water light.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2026
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 September 2024 Resolved
Replace 01 fire bucket
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 August 2026
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2023 Resolved
Vessels first aid kit was found to have expired Aspirin. Vessel owner/operator shall supply the vessel with up to date aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 13 August 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 September 2023 Resolved
Battery installed in life ring strobe light was found expired. Vessel Owner/Operator shall replace battery with an up to date battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 September 2023
Resolved 13 August 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 August 2022 Resolved
Vessel had 03 adult PFD's that were found deteriorated. Vessel owner/operator shall replace the PFD's to ensure their is a sufficient amount of PFD's for the passenger capacity. * Vessel is limited to carrying a maximum of 44 Passengers until the owner/operator replace the 03 Adult PFD's.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2022
Resolved 19 August 2022
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2021 No resolution recorded
Vessel was unavailable to conduct Keel bolt inspection. Make vessel available for inspection once vessel is pulled from service in 2021 season to allow internal inspection.
Action required: 705 - Other - as specified
Due 1 May 2022 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 May 2021 Resolved
In Void #2, discovered wastage in starboard vertical frame #9. Provide repair proposal of permanent repair to the satisfaction to the attending Marine Inspector. Proposal must be reviewed and approved prior to commencing repair.
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 9 June 2021
Resolution: MI found repair satisfactory
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 May 2021 Resolved
In Void #4, discovered wastage in vertical frames 1-6, and keelson. Provide repair proposal of permanent repair to the satisfaction to the attending Marine Inspector. Proposal must be reviewed and approved prior to commencing repair.
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 9 June 2021
Resolution: MI found repair satisfactory
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2021 Resolved
Discovered noticeable weeping at external keel located five feet forward of shaft bearing on port and starboard side and discovered an unknown/undocumented repair located approximately 15' forward of shaft bearing on keel. Remove paint to better expose and assess areas.
Action required: 705 - Other - as specified
Due 30 June 2021
Resolved 9 June 2021
Resolution: MI found repair satisfactory
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 24 June 2019 Resolved
Prove proper operations of the bilge high water alarm for the lazeratte prior to commercial service.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2019
Resolved 25 June 2019
Resolution: Received statement from poc attesting to sat repair follow up visit 7/1.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 24 June 2019 Resolved
Void #2; de-water and maintain dry and ventilated.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Received statement from poc attesting to sat repair follow up visit 7/1.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 June 2019 Resolved
emove coating of sludge, grime and debris from propulsion engine surfaces.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Received statement from poc attesting to sat repair follow up visit 7/1.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2019 Resolved
Coat bare negative wire at battery
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Received statement from poc attesting to sat repair follow up visit 7/1.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2019 Resolved
Enlarge battery box and cover cutouts for leads to allow proper fit.
Action required: 705 - Other - as specified
Due 1 July 2019
Resolved 25 June 2019
Resolution: Received statement from poc attesting to sat repair follow up visit 7/1.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 24 June 2019 Resolved
Prior to 2020 operating season replace wasted fasteners within void #2. Make vessel available for inspection once vessel is pulled from service in 2019 to allow internal inspection.
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 9 June 2021
Resolution: MI found satisfactory
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 14 June 2018 Resolved
Modify emergency procedures to reflect actual course.
Action required: 705 - Other - as specified
Due 14 July 2018
Resolved 5 July 2018
Resolution: Posted procedures reflect actual emergency response.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 14 June 2018 Resolved
Make deck hatches watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2018
Resolved 5 July 2018
Resolution: Received email with photos of repaired hatches before the 28th and completed verification during def check with sat results.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 14 June 2018 Resolved
Prove proper operation of emergency steering operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2018
Resolved 5 July 2018
Resolution: Demonstrated adequate means prior to departures however master not comfortable with measures. O/O and master completed training with crew. Demonstration provided during def check.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 6 July 2017 Resolved
Correct life jacket stowage to be readily avialable for an emergency.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 31 August 2017
Resolution: Attended vessel witnessing sat retrieval of stowed jackets.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 July 2017 Resolved
Provide suitable hull strainer for the cooling water intake on the main engine. Provide a plan to the Coast Guard for repair/install.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 7 June 2018
Resolution: External strainer installed.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 23 June 2017 Resolved
Found 8 life jackets that need new retro reflective tape.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 23 June 2017 Resolved
Found 1 life jacket that needs to be marked with the name of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 June 2017 Resolved
Found 3 child life jackets with ripped seams. Replacement jackets to be provided.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Lifesaving › Hand Flares › Expired
Issued 23 June 2017 Resolved
The three orange smoke signals are expired and need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 June 2017 Resolved
The battery on the floating water light needs to be replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 23 June 2017 Resolved
The emergency fuel shutoff needs to be marked and show the direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Electrical › Electrical Distribution System (service) › Cable
Issued 23 June 2017 Resolved
Secure electrical cable from battery to alternator from running in the bilge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Engineering › Steering Gear System › Rudder
Issued 23 June 2017 Resolved
Correct leaking rudder post.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2018
Resolved 7 June 2018
Resolution: Inspection of arrangement sat.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 June 2017 Resolved
Provide current copy of Certificate of Documentation.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 20 July 2017
Resolution: Vessel operator provided a copy of their COD to clear deficiency.
Navigation › Piloting/Steering › US Coast Pilot
Issued 23 June 2017 Resolved
Provide current copy of CG Light List and Coast Pilot.
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Documentation › Logs/Records › Logbook (official)
Issued 23 June 2017 Resolved
Operator unable to provide drill records for the previous operating season.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 June 2017
Resolved 23 June 2017
Resolution: The vessel operator has drill records for this season and going foward will ensure records are maintained.
Operations/Management › Drills/Instruction › Not Conducted
Issued 23 June 2017 Resolved
Conduct emergency drills with USCG and full crew.
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Engineering › Bilge Water Management System › Not Operational
Issued 23 June 2017 Resolved
Clean water out of bilges for follow-up inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 July 2017
Resolved 6 July 2017
Resolution: Corrected to the satisfaction of the attending marine inspector.
Documentation › Certificates/Documents › FCC SSL
Issued 14 October 2014 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 14 October 2014
Resolved 14 October 2014
Resolution: Received email copy of FCC/SSL.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 September 2011 Resolved
Replace or repair indicated PFD's with retro-reflective tape per 46 CFR 180.75
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 September 2011
Resolved 28 September 2011
Resolution: Vessel replaced retro reflective tape on indicated PFD''s.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 12 September 2011 Resolved
Replace or repair ring lifebuoy waterlight. Prior to operating at night.
Condition: Improper/Lack of Maintenance
Due 28 September 2011
Resolved 28 September 2011
Resolution: Vessel replaced ring lifebuoy waterlight.
Navigation › Piloting/Steering › US Coast Pilot
Issued 12 September 2011 Resolved
Provide current U.S. Coast Pilot, and Rules of the Road (Colregs).
Action required: 705 - Other - as specified
Due 28 September 2011
Resolved 28 September 2011
Resolution: Vessel provided current U.S. Coast Pilot and Rules of the Road.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 September 2011 Resolved
Repair stbd nav light and masthead light prior to operating at night.
Condition: Placed in Improper Service
Due 28 September 2011
Resolved 28 September 2011
Resolution: Vessel repaired stbd nav light and masthead light.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 October 2007 Resolved
Provide a copy of current Certificate of Documentation to the attending maine inspector.
Due 14 November 2007
Resolved 1 November 2007
Resolution: Provided a copy of current Certificate of Documentation to the attending marine inspector.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 30 October 2007 Resolved
Renew corroded engine space fire extinguisher hose and fittings at the bottle IAW 46 CFR 176.810.
Due 14 November 2007
Resolved 1 November 2007
Resolution: Renewed corroded engine space fire extinguisher hose and fittings at the bottle IAW 46 CFR 1760.810.
Stability › Watertight Integrity › General
Issued 30 October 2007 Resolved
Tighten the new drive shaft packing IAW 46 CFR 176.670 / 182.220
Due 14 November 2007
Resolved 1 November 2007
Resolution: Tightened the new drive shaft packing IAW 46 CFR 176.670 / 182.220.
Documentation › Certificates/Documents › FCC SSL
Issued 13 September 2006 Resolved
Provide proof of FCC Safety Certificate i.a.w. 47 CFR 80.903. Vessel restricted to not more than 1000 feet from shore until proof is provided.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 3 October 2006
Resolution: Vessel owner provided proof of FCC Safety Certificate as required.
Documentation › Certificates/Documents › FCC SSL
Issued 13 September 2006 Resolved
Provide proof of FCC Marine Radio Operator Permit as required by route and 47 CFR 80. Vessel restricted to not more than 1000 feet from shore until proof is provided.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 22 March 2007
Resolution: Amended COI limiting vessel to not more than 1000 feet from shore.
Navigation › Piloting/Steering › Marine Charts
Issued 13 September 2006 Resolved
Provide charts for local operating area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 September 2006
Resolved 3 October 2006
Resolution: Charts provided for local area as required.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 13 September 2006 Resolved
Update new hailing port on vessel as required.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 September 2006
Resolved 3 October 2006
Resolution: New hailing port updated on vessel as required.
Engineering › Bilge Water Management System › Interface Detector
Issued 13 September 2006 Resolved
Provide proof of operation on forward & aft bilge high level alarms for audible indications. Both work but not at level needed to hear with engine running.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2006
Resolved 3 October 2006
Resolution: Proved proper operation of forward and aft bilge high level alarms for audible indications.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 September 2006 Resolved
Install machinery guard over engine belts.
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 September 2006
Resolved 3 October 2006
Resolution: Properly installed machinery guard as required.
Construction/Loadline › Penetrations › Valve Flange
Issued 31 May 2006 Resolved
Make all gate valves located 6 inches above the deepest load water line and below available for inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: Completed to the satisfaction of the attending Marine Inspector.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 31 May 2006 Resolved
Replace cutlass bearing on tail shaft.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: Completed to the satisfaction of the attending marine inspector.
Construction/Loadline › Hull › Bottom Plating
Issued 31 May 2006 Resolved
Repair penetration in hull just aft of the main diesel engine (approximately 4 inches off keel) on the port side.
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: Completed to the satisfaction the attending Marine Inspector.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 31 May 2006 Resolved
Clean out exhaust piping from the transom to the main.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: Completed to the satisfaction of the attending Marine Inspection.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 31 May 2006 Resolved
Clean out exhaust piping from the transom to the main.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 June 2006
Resolution: Completed to the satisfaction of the attending Coast Guard Maine Inspector.
Documentation › Certificates/Documents
Issued 2 May 2002 Resolved
Provide current safety radio certificate. Vessel is restricted to 1000 feet from shore until deficiency is cleared to the satisfactory of attending marine inspector. LEGACY COMPONENT DESC: Cargo Ship Safety Radio Certificate
Due 30 May 2002
Resolved 10 May 2002
Documentation › Certificates/Documents
Issued 2 May 2002 Resolved
Post current COI. LEGACY COMPONENT DESC: Certificate of Inspection
Due 31 May 2002
Resolved 9 May 2002
Documentation › Markings/Placards
Issued 2 May 2002 Resolved
Post emergency broadcast placard.
Due 31 May 2002
Resolved 9 May 2002
Resolution: Provide owner with placard.
Construction/Loadline › Hull
Issued 12 April 2002 Resolved
Make repairs to FRP as original on starboard side aft at transom.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 10 May 2002
Construction/Loadline › Hull
Issued 12 April 2002 Resolved
Make repairs to FRP as original at centerline transom at turn of the bilge.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 May 2002
Resolved 10 May 2002
Fire Fighting
Issued 30 April 2001 Resolved
REMOVE COMBUSTIBLE SOUND DEADENING MATERIAL FROM OVERHEAD IN ENGINE ROOM ORPROVIDE ALTERNATIVE PLAN TO MINIMIZE FIRE HAZARD.
Condition: Unknown
Due 30 April 2001
Resolved 30 April 2001
Construction/Loadline
Issued 13 November 1997 Resolved
RENEW PLANK ON PORT SIDE IN WAY OF SEWAGE TANK OVERBOARD VALVE. NEW PLANK TO COVER AT LEAST THREE FRAMES. TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 November 1997
Resolved 13 November 1997
Construction/Loadline
Issued 13 November 1997 Resolved
RENEW BOTTOM TEN INCHES OF THE TRAMSON PLANK. TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 November 1997
Resolved 13 November 1997
Accommodation/Occupational Safety
Issued 6 November 1995 Resolved
REPLACE STBD MSD TANK VENT HOSE.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Construction/Loadline
Issued 6 November 1995 Resolved
REPLACE THE FWD AND AFT HATCHES.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Construction/Loadline
Issued 6 November 1995 Resolved
REPLACE AFT MAIN DECK AREA BETWEEN THE HEADS.
Condition: Unknown
Due 6 November 1995
Resolved 6 November 1995
Lifesaving
Issued 6 March 1991 Resolved
DEMONSTRATE OPERATION OF WATERLIGHT FOR LIFE RING
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Engineering
Issued 6 March 1991 Resolved
DEMONSTRATE OPERATION OF MAIN PROPULTION
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Engineering
Issued 6 March 1991 Resolved
DEMONSTRATE OPERATION OF BILGE FLOAT INDICATOR LIGHT AT OPERATOR'S STATION
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Fire Fighting
Issued 6 March 1991 Resolved
DEMONSTRATE OPERATION OF FIRE PUMP
Condition: Unknown
Due 6 March 1991
Resolved 6 March 1991
Fire Fighting
Issued 10 May 1990 Resolved
PLACE GUARD AROUND FIRE PUMP DRIVE BELTS
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Documentation
Issued 10 May 1990 Resolved
PROVIDE CERTIFICATION LETTER STATING THAT DRUG TESTING PROGRAM HAS BEGUN BY 21DEC90
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Fire Fighting
Issued 10 May 1990 Resolved
MOUNT 2ND B-II FIRE EXTINGUISHER
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Engineering
Issued 10 May 1990 Resolved
LABEL FUEL SHUT-OFF VALVE ABOVE MAIN DECK
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Construction/Loadline
Issued 25 April 1989 Resolved
DOUBLE CLAMP SEAWATER INLET HOSE FOR TOILET
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 25 April 1989 Resolved
DEMONSTRATE OPERATION OF PUBLIC ADDRESS SYSTEM
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Navigation
Issued 25 April 1989 Resolved
PROVIDE UP-TO-DATE CHART OF OPERATING AREA, INLAND NAVIGATION RULES
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Accommodation/Occupational Safety
Issued 25 April 1989 Resolved
LOCK MSD ON BOARD DISCHARGE VALVES CLOSED AND PROVIDE MEANS FOR PUMPING AND HOLDING TANK
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Documentation
Issued 25 April 1989 Resolved
PROVIDE FCC STATION LICENSE, FCC SAFETY CERTIFICATE & MARINE RADIO OPERATORS PERMIT
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Lifesaving
Issued 25 April 1989 Resolved
MARK LOCATION OF STOWAGE OF ADULT AND CHILD PFD'S ACCORDING TO 46 CFR 180.25-15
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Navigation
Issued 25 April 1989 Resolved
REPLACE COTTER PIN THAT PENETRATES LOWER RUDDER STOCK
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Navigation
Issued 25 April 1989 Resolved
ADD ONE ADDITIONAL NUT TO BOLT AT STEERING LINKAGE
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Engineering
Issued 25 April 1989 Resolved
DEMONSTRATE OPERATION OF MAIN ENGINE STBD FIRE PUMP
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Engineering
Issued 18 May 1988 Resolved
CONDUCT OPERATIONAL TEST OF MAIN PROPULSION AND FIRE PUMP
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Navigation
Issued 18 May 1988 Resolved
PROVIDE WATERPROOF CONTAINER FOR FLARES
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Construction/Loadline
Issued 18 May 1988 Resolved
REMOVE SLUICE VALVE IN COLLISION BULKHEAD AND MAKE PENETRATION WATERTIGHT
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Lifesaving
Issued 18 May 1988 Resolved
PROVIDE 18' LINE TO ATTACH WATERLIGHT TO RING BUOY
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Accommodation/Occupational Safety
Issued 18 May 1988 Resolved
EXTEND ONE VENT IN MACHINERY SPACE TO BILGE
Condition: Unknown
Due 18 May 1988
Resolved 18 May 1988
Unknown
Issued 28 March 1985 Resolved
MOUNT EMERGENCY CHECK OFF LIST
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
MOUNT COMPASS AND ELECTRONIC EQUIPMENT
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985
Unknown
Issued 28 March 1985 Resolved
PROVIDE 6 RED AND 6 ORANGE FLARES..
Condition: Unknown
Due 28 March 1985
Resolved 28 March 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.