MAURY USCG vessel records
← All vessels

MILLER BOYS

MILLER BOYS is a 1982 passenger vessel (inspected). The Coast Guard has recorded 14 inspections since 2016, most recently in November 2025, along with 50 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 20 November 2025.

Built
1982
Last inspected
20 November 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 20 November 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDA4373
Flag
UNITED STATES
Maury page id
psix-55266

Documentation record

Registered dimensions (L × B × D)32.6 ft × 10.8 ft × 5.3 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMONARK BOAT COMPANY · MONTICELLO AR, UNITED STATES · built 1982
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 14

20 November 2025 Deficiency Check · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8266496
7 March 2024 Deficiency Check · Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7862321
1 November 2023 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7818517
29 June 2022 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7490391
18 November 2021 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7543113
19 October 2020 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7079724
15 June 2020 Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6973865
11 December 2019 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6872027
5 October 2018 COI Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6555157
2 October 2018 Simplified Stability Test
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6553273
28 June 2018 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6458711
1 November 2017 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6298472
19 October 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6025959
7 July 2016 Drydock Exam · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5932842

Deficiency record · 50

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 November 2025 Resolved
Remote fuel shutoff stations shall be marked in at least 1 inch letters indicating purpose of the valve and direction of operation. Remote fuel shutoff is missing direction of operation. 46 CFR 185.30-20(a)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: Remote fuel shutoff was stenciled with direction of operation. Rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 November 2025 Resolved
Portable fire extinguishers shall be installed and located to the satisfaction of the Officer in Charge Marine Inspection. Fire extinguisher in cabin space is being stored on deck and not in a bracket. 46 CFR 181.30-10
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: Fire extinguisher has been installed in bracket. Rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Bulwarks and freeing ports
Issued 20 November 2025 Resolved
Rails or equivalent protection shall be installed near the periphery of all weather decks. Forward handrail base has broken welds.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: Rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 20 November 2025 Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Forward peak hatch needs to be adjusted and captive chain securing the hatch in cabin room is missing.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: Captive chain was installed. Rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 November 2025 Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Child life jackets are not physically separated from adults.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2025
Resolved 4 December 2025
Resolution: Lifejackets were separated in two different compartments. Rectified.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 20 November 2025 Resolved
The employer shall provide an Employee Assistance Program for all crew members that includes both education and training on the effects and consequences of drug and alcohol use. Supervisory personnel must receive at least 60 minutes of training. Conduct chemical testing program compliance audit and provide satisfactory evidence of an Employee Assistance Program.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2025
Resolved 8 December 2025
Resolution: Conducted a satisfactory DAPI Audit. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 16 September 2024 Resolved
Aft bulkhead in steering void has major deflection IVO center port & stbd 1st bays. Crop and renew as discussed. Submit a plan proposal for repair prior to starting.
Action required: 705 - Other - as specified
Resolved 14 January 2025
Resolution: Crop and renewal sat.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 26 March 2024 Resolved
Except as otherwise provided in this section, rails or equivalent protection shall be installed near the periphery of all weather decks accessible to passengers and crews... Rails of a sufficient height not present on fantail or bow.
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2024
Resolved 10 October 2024
Resolution: Courses present for passenger carrying area's of aft deck.
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 24 March 2024 Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's ...stability letter, Certificate of Inspection...as the case may be. Operator explained that the vessel utilizes tow bit on main deck as well as periodically operates as a dive boat. Both operating conditions have different implications for the vessel's stability and limitations on either operation shall be addressed on the stability letter. Most recent stability letter from 15OCT2018 indicates "no deck cargo may be carried" and does not mention any variable loads from dive equipment or towing operations authorized.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2025
Resolution: Rectified, vessel does not conduct tow operations.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2024 Resolved
(a) All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment... except...the space forward the collision bulkhead... (b)...The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. (c)The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be provided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some accessible point in the bilge line... The vessel does not have a bilge system in compliance with Old Subchapter T regulations or new Subchapter T regulations. The bilge manifold system addresses the Engine Room and Compartment 3, however, the manifold does not run to the lazzarette or Compartment 2. The engine room suction does not have a strainer and Compartment 3's bilge suction was inaccessible to inspection. There is no installed means of dewatering Compartment 2 and they were multiple electric pumps being utilized without plan approval/OCMI verification.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 January 2025
Resolution: Bilge system is compliant
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2024 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the... (7) Bilge and drainage systems. The means provided for pumping bilges shall be tested by operation... Bilge suction lines had evidence of oily waste. Operator was unable to test function of bilge system without causing a possible pollution incident.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2025
Resolution: Vessel has subsumergible pums and portable pump.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 24 March 2024 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate... the recovery of persons who have fallen overboard. Observed crew member currently certified in CPR and 1st Aid unable to demonstrate necessary actions following a man overboard. Conduct sufficient training and familiarization.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2025
Resolution: MOB drill/training was conducted all sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 24 March 2024 Resolved
...a vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible... Vessel had neither printed charts within 6months of inspection or up-to-date electronic charts.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2025
Resolution: Provided up to date charts.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 March 2024 Resolved
...insure that the main propulsion machinery installed on each vessel is suitable for the vessel and its operation... that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. USCG MI observed diesel fuel collected on top the port engine representing significant fire hazard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2024
Resolution: Cleaned
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 March 2024 Resolved
(b) Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. There is no battery cover on battery located on the port side of engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 November 2025
Resolution: Rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 24 March 2024 Resolved
Each hatch exposed to the weather must be watertight... Observed no gasket material on main deck hatch covers to engine room representing significant downflooding risk. Operator agreed to revisit an adequate test of watertight integrity after installation of gasket material.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2025
Resolution: Hatch is weathertight and a gasket will impede hatch to properly close.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 March 2024 Resolved
An internal structural examination conducted in compliance with § 176.600 may be conducted while the vessel is afloat... and consists of a complete examination of the vessel's main strength members, including the major internal framing, the hull plating and planking, voids, and ballast, cargo, and fuel oil tanks. Where the internal framing, plating, or planking of the vessel is concealed, sections of the lining, ceiling or insulation may be removed or the parts otherwise probed or exposed so that the inspector may be satisfied as to the condition of the hull structure. The hull plating thickness is recorded as 1/4inch, USCG MI observed significant corrosion in compartment 2 and 3 with gauged pits [1/16,3/32]inch in several areas of compartment 2. Compartment 3 shall be made accessible to USCG MI at the next drydock availability to conduct an internal structures examination of the space.
Action required: 705 - Other - as specified
Resolved 10 October 2024
Resolution: Drydock Deficiencies cover this and access made into void 3.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 November 2023 Resolved
A Certificate of Inspection is valid for 5 years for all other vessels. Vessel's Certificate of Inspection is expired. Complete a satisfactory COI renewal inspection and obtain a valid COI prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 November 2025
Resolution: COI Renewal completed.
02 - Structural Conditions › N/A - No Subsystem › Information on the A/A-max Ratio (Roro/pass. only)
Issued 29 June 2022 Resolved
Repair pinhole identified in aft starboard side of lazarette void. Prior to credit dry dock.
Action required: 705 - Other - as specified
Resolved 3 August 2022
Resolution: Verified satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - operational damage
Issued 29 June 2022 Resolved
Bulkhead penetration between forward void and cabin void not watertight. Repair to make fitting watertight. Prior to Credit DDX.
Action required: 705 - Other - as specified
Resolved 3 August 2022
Resolution: Verified satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 29 June 2022 Resolved
Cracked deck welds identified in following locations: aft deck port and starboard side, port side middle cleat, starboard side forward cleat. Repair welds. Prior to Credit DDX.
Action required: 705 - Other - as specified
Resolved 3 August 2022
Resolution: Verified satisfactory repair.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 29 June 2022 Resolved
Forepeak gasket worn. Replace gasket to make watertight. Repair prior to credit DDX
Action required: 705 - Other - as specified
Resolved 3 August 2022
Resolution: Verified satisfactory repair.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 19 October 2020 Resolved
Vessel operator failed to provide monthly inspections and testing of vessel's EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 October 2020
Resolved 19 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2020 Resolved
Vessel requires servicing of starboard fuel oil shut off valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 26 October 2020
Resolution: Witnessed satisfactory servicing of valve on follow up visit to vessel.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 19 October 2020 Resolved
Vessel has a cracked weld where deck stringer meats shear strake.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2020
Resolved 13 December 2020
Resolution: Witnessed successful repair of damage on starboard quarter while conducting inspection of other vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2019 Resolved
The vessel MILLER BOYS is a SPV T-S (OLD T), therefore not required a safety management system (SMS) per regulation. SECTOR NEW YORK has found the following deficiencies to be objective evidence that a serious substandard condition has not been pro-actively managed by the vessel's owner/operator, leading to a lack of safety culture onboard the vessel. 46 CFR 176.25 - OLD T 46 CFR 176.800
Action required: 30 - Ship detained
Resolved 20 December 2019
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 December 2019 Resolved
At each inspection for certification and re-inspection the Marine Inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. There was approximately 4" inches of water and emulsified oil in the engine space bilge, approximately 5" inches of water and fuel oil in the lazarette, and approximately 6" in the midships void space. Clean and dewater all bilge and void spaces. 46 CFR 176.25-50(b) OLD T
Action required: 30 - Ship detained
Resolved 20 December 2019
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 11 December 2019 Resolved
At each initial and subsequent inspection for certification, re-inspection and at every other vessel inspection the Marine Inspector shall require that all observed unsafe practices and hazardous situations be corrected. The starboard front window was previously logged as broken in May of 2019 and was found missing. Replace window prior to movement. 46 CFR 176.25-50(a) OLD T
Action required: 30 - Ship detained
Resolved 20 December 2019
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 December 2019 Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. The forward watertight hatch does not properly secure due to the seized dogging T handle. Replace or repair locking device components. 46 CFR 185.20-15 OLD T
Action required: 30 - Ship detained
Resolved 20 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2019 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference; see 46 CFR 175.600) or be specifically approved by the Commandant. Unapproved fuel hose in use on port and starboard fuel supply lines and on the port side fuel return line. Replaced with approved hose.
Action required: 30 - Ship detained
Resolved 20 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 December 2019 Resolved
In systems and applications where flexible hoses are permitted to be clamped: (1) Double hose clamping is required where practicable. The shaft through hull hose was not double clamped. Double clamp hoses as required. 46 CFR 182.410(d)(1)
Action required: 30 - Ship detained
Resolved 20 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2019 Resolved
The master shall conduct drills and give instructions as necessary to ensure that all crew members are familiar with their duties. Man overboard drills have not been performed since May 2019. Crew must perform MOB drills prior to carrying passengers. 46 CFR 185.25-10 OLD T
Action required: 30 - Ship detained
Resolved 20 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2019 Resolved
The master of a vessel, except a vessel listed in § 185.502(a) of this part, shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Vessel does not maintain a passenger count onboard and it is not communicated ashore as required. 46 CFR 185.504
Action required: 30 - Ship detained
Resolved 20 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 11 December 2019 Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The starboard RPM gauge installed after 1996 is inoperable. Replace RPM gauge. 46 CFR 182.410
Action required: 30 - Ship detained
Resolved 20 December 2019
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 December 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. The vessel had 3 first aid kits missing items and numerous items were expired. Vessel must have a first aid kit with all required contents. 46 CFR 184.710
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 December 2019 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel was missing 01 fire bucket. Vessel must procure additional fire bucket. 46 CFR 181.610
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 December 2019 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that (3) The pump is permanently mounted. The lazarette submersible electric bilge pump and switch was not permanently mounted. Vessel must permanantly mount bilge pump and switch. 46 CFR 182.520(e)(3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019 Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure. Wires for the forward bilge pump are not connected in an enclosure. Place wire in an enclosure as required. 46 CFR 183.340(g)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019 Resolved
Electrical equipment on a vessel must be installed and maintained to: (c) Minimize accidental personnel contact with energized parts. Bridge light is inoperable and hanging from overhead. 46 CFR 183.200(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 December 2019 Resolved
Receptacle outlets and attachment plugs for portable lamps, tools, and similar apparatus operating at 100 volts or more, must have a grounding pole and a grounding conductor in the portable cord. An ungrounded portable space heater was found in the main cabin. Crew immediately removed the space heater from the vessel. 46 CFR 183.370(b)
Action required: 10 - Deficiency Rectified
Resolved 20 December 2019
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2019 Resolved
Alcohol-testing devices must be used according to the procedures specified by the manufacturer of the testing device and by this part. Vessel had 03 expired alcohol testing devices onboard. The crew replaced the exipred devices with new ones. 46 CFR 4.06-3(a)(2)
Action required: 10 - Deficiency Rectified
Resolved 20 December 2019
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 11 December 2019 Resolved
As appropriate for the intended voyage, all vessels must carry adequate and up-to-date- (a) Charts; (h) All other nautical publications necessary. Vessel had outdated charts and NAVRULES. Provide up to date charts and NARULES. 46 CFR 185.20-35 OLD T
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 December 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2018 Resolved
ALL ELECTRICAL RECEPTACLES EXPOSED TO THE WEATHER SHALL BE WEATHERTIGHT. THE ELECTRICAL JUNCTION BOX ON TOP OF THE PILOT HOUSE WAS DAMAGED AND NOT WEATHERTIGHT. 46CFR183.05-35(b) OLD T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2018
Resolved 19 October 2018
Resolution: Receptacle was replaced in kind with a new unit.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 October 2018 Resolved
ALL NAVIGATION LIGHTS SHALL BE COMPLIANT WITH THE INLAND RULES OF NAVIGATION. THE STARBOARD SIDE NAVIGATION LIGHT WAS NOT SECURED TO THE MOUNTING PLATE, LIMITIN THE AFFECTIVE ARC OF VISIBILITY. VESSEL IS LIMITED TO DAYLIGHT TRANSIT UNTIL RECTIFICATION.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2018
Resolved 19 October 2018
Resolution: The navigation light was properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 October 2018 Resolved
ELECTRICAL INSTALLATIONS SHALL BE MADE TO THE SATISFACTION OF THE [name withheld] WAS A DEAD END WIRE COMING OFF OF THE STARBOARD SIDE HORN INSTALLATION. 46CFR183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 October 2018
Resolved 19 October 2018
Resolution: The dead-end wire was re-attached.
Lifesaving › Inflatable Buoyant Apparatus › Quantity
Issued 16 February 2018 Resolved
Life floats were replaced with IBAs, this change resulted in known aggregate weight change of 471lbs. The vessel last underwent a stability test in 1995. Vessel must address stability to the satisfaction of [name withheld] count reduced to 13, and total persons reduced to 15.
Action required: 705 - Other - as specified
Resolved 5 October 2018
Resolution: SST was conducted in the presence of USCG MI's on 02OCT2018.
Communications › Radio Communications › VHF Radiotelephone
Issued 1 November 2017 Resolved
Properly install DSC-capable VHF radio and program MMSI number.
Action required: 705 - Other - as specified
Due 8 November 2017
Resolved 20 November 2017
Resolution: Observed proper installation of required DSC-capable VHF radio (with programmed MMSI number).
Communications › Alarms/Indicators › High Water Alarm
Issued 1 November 2017 Resolved
Label high water alarm in operating station for lazarette.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 20 November 2017
Resolution: Observed required labeling of high water alarm for lazarette space.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 1 November 2017 Resolved
Provide aspirin for first aid kit.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 20 November 2017
Resolution: Observed unexpired aspirin for first aid kit.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 1 November 2017 Resolved
Enclose loose wires identified in engine room in a junction box.
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 20 November 2017
Resolution: Observed junction box enclosing loose wires in engine space.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.