Records from 1985 to 2025. Most recent: inspection, 28 May 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 May 2025
Resolved
…All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
Belts on both engine PTO loose and worn.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 1 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2025
Resolved
All fuel tanks must be electrically bonded to a common ground. Fuel fill needs to be bonded to a common ground
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 1 July 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 May 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Plastic waste receptacle on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 1 July 2025
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 28 May 2025
Resolved
Each hull identification number must be carved, burned, stamped, embossed, molded, bonded, or otherwise permanently affixed to the boat so that alteration, removal, or replacement would be obvious. Hull identification number was posted on a removable wood plaque.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 1 July 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 May 2025
No resolution recorded
The discharge ends of fuel tank vent pipes must terminate on the hull exterior as high above the waterline as practicable and remote from any hull openings, or they must terminate in U-bends as high above the weather deck as practicable and as far as practicable from openings into any enclosed spaces. Vent pipes terminating on the hull exterior must be installed or equipped to prevent the accidental contamination of the fuel by water under normal operating conditions.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 May 2027
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 August 2024
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard (fire, heavy weather, or man overboard conditions) required by § 185.510 of this part. Drills are not being properly documented and crew failed to demonstrate knowledge of drill procedures.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2024
Resolved 8 August 2024
Resolution: Drills completed in the presence of MI and logged as required.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 6 August 2024
Resolved
Provisions shall be made by means of plugs, covers, ect to prevent admission of air into the space protected. Engine room ventilation cover inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2024
Resolved 8 August 2024
Resolution: Attaching device installed to secure ventilation in the closed position.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 August 2024
Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Emergency Instructions” listed in § 185.512. The emergency instructions must be designed to address the particular equipment, arrangement, and operation of each individual vessel. Emergency instruction placards do not address all requirements for vessels systems.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 August 2024
Resolved 8 August 2024
Resolution: Emergency instructions posted as required.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 6 August 2024
Resolved
Each EPIRB must be tested monthly, using the integrated test circuit and output indicator, to determine that it is operative. EPIRB is not being tested monthly.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 8 August 2024
Resolution: EPRIB being tested as required.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 August 2024
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests on portable fire extinguishers:Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Crew is not conducting monthly inspections of fire extinguishers and is not documenting inspections as required.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2024
Resolved 8 August 2024
Resolution: Fire extinguishers being tested as required.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 August 2024
Resolved
A hatch cover must:(1) Have securing devices; and(2) Be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Steering space hatch not properly secured to prevent loss.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 8 August 2024
Resolution: Hatch cover properly tethered
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 6 August 2024
Resolved
Watertight hatches must be marked in clearly legible letters at least 25 millimeters (1 inch) high: “WATERTIGHT HATCH—KEEP CLOSED”. Water tight hatches on main deck missing label.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 8 August 2024
Resolution: Hatch cover properly labeled
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 6 August 2024
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Light on compass inoperative.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 8 August 2024
Resolution: Compass light properly wired
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 August 2024
Resolved
Each life float must meet the requirements in subpart 160.010 of this chapter - Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. Retro reflective material installed not the approved type.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 8 August 2024
Resolution: Solas tape installed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 August 2024
Resolved
When the flexible section of hose between fill and tank is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. Wire joining fuel fill and tank broken.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 8 August 2024
Resolution: Fuel tank properly bound to fill
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 6 August 2024
Resolved
Section 151.59 (Garbage Placards) applies to—(1) A manned U.S. ship (other than a fixed or floating drilling rig or other platform) that is 26 feet or more in length. Vessel is missing garbage placard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 8 August 2024
Resolution: Garbage placard installed
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 August 2024
Resolved
Vessels subject to part III of title III of the Communications Act that operate in the waters described in § 80.901 must, at a minimum, be equipped as follows:(1) Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2), except that a VHF radiotelephone installation without DSC capability is permitted until one year after the Coast Guard notifies the Commission that shore-based sea area A1 coverage is established. Vessels in this category must not operate more than 20 nautical miles from land. Vessels VHS-DSC is not programmed with vessel's MMSI# required by 47 CFR 80.103(b) (MMSI number programmed into DSC radios)-47 CFR 80.905(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 September 2024
Resolved 8 August 2024
Resolution: Vessel radio programmed with MMSI number
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 29 August 2023
Resolved
A vessel must carry one floating waterlight.
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feel, securing the waterlight around the body of the ring life buoy… [and] must be attached to the lanyard with a corrosion-resistant clip. 1) replace expired battery 2) place waterlight on a lanyard 3) attach the lanyard to the buoy with a clip.
46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2023
Resolution: New battery installed and line made up appropriately.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. 1) obtain 10 missing life jackets 2) renew retro-reflective tape 3) renew faded labeling.
46 CFR 180.25-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 August 2023
Resolution: Vsl requested that the passenger count be reduced to 38 and max pob to 40. 10 life jackets no longer required.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2023
Resolved
46 CFR 180.78
701c
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Mark lifejacket compartment and make it clear that the child size lifejackets are stowed separately.
46 CFR 180.78
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2023
Resolution: Lifejacket retroreflective tape and markings renewed. Number made moot after reduction of passengers by owners request.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 August 2023
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Obtain and post placards for all types of life jackets on board (including all newly purchased life jackets).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 August 2023
Resolution: Placards posted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 August 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Vessel electrical connections were exposed and subject to accidental contact and shock hazards requiring physical barrier to protect crew and equipment.
46 CFR 183.200(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 September 2023
Resolved 31 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 August 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Renew starboard engine belt guard.
46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 August 2023
Resolution: Machinery guard renewed.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 29 August 2023
Resolved
Each device must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warnings pertinent to the device. The size of the letters printed on the placard must be one-eighth of an inch or larger. Obtain appropriate placarding for MSD.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 31 August 2023
Resolution: MSD confirmed to be type III
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 July 2021
Resolved
Ring Buoy - provide a 60' lifeline and provide a clip for the water floatlight.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2021
Resolution: Operator installed new 60' lifeline and installed a new clip for the water floatlight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 July 2021
Resolved
Found nuerous ground wires detached from fittings. Re-attach ground wires to appropriate grounds.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2021
Resolution: Observed ground wires throughout vessel reattached to fittings.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 21 July 2021
Resolved
Found water egressing in way of port stern corner in lazarette. Make proper repairs to ensure water tight integrity is maintained.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2021
Resolution: Observed repair work of FRP.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 July 2021
Resolved
Found numerous dead end wires in way of operating station. Remove all dead end wires.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 26 August 2021
Resolution: Dead end wires removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 June 2020
Resolved
cap or remove dead end wires behind operating console and in forward space.
46 CFR 183.200
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 8 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 4 June 2020
Resolved
replace guard for starboard engine.
Action required: 10 - Deficiency Rectified
Due 4 June 2020
Resolved 4 June 2020
Resolution: crew replaced guard before inspectors departed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2020
Resolved
replace first aid kit. Multiple items in first aid kit are expired.
46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 21 July 2021
Resolution: Vessel is equipped with proper first aid kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 June 2020
Resolved
provide proof of FCC Radio Station Authorization
47 CFR 13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2020
Resolved 21 July 2021
Resolution: Vessel provided current FCC Radio Station Authorization
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 June 2020
Resolved
provide new alcohol test kits, test kits onboard are expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2020
Resolved 21 July 2021
Resolution: Vessel provided valid alcohol test kit.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 July 2019
Resolved
Make repairs to small crack identified on one of the corners of the lifefloat, using approved materials.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 July 2019
Resolution: Pictures were provided showing adequate repairs made using approved patch kit.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 8 August 2018
Resolved
A Certificate of Inspection is valid for 1 year for vessels carrying more than 12 passengers on international voyages. Vessel's COI annual exam expired on 7 Aug 2018. Vessel is limited to carrying 06 passengers until an annual inspection is completed. 46 CFR 176.107(a)
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 August 2018
Resolved 15 August 2018
Resolution: Vessel completed COI annual exam on 15 Aug 2018.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 20 July 2017
Resolved
PROVIDE DETACHABLE CLIP FOR WATER LIGHT/RING BUOY ARRANGEMENT. 46 CFR 180.70(d)(3).
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 9 August 2017
Resolution: verified clip, cleared def.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 20 July 2017
Resolved
RE-LABEL LIFE JACKET CAPACITY TO PROPERLY IDENTIFY ADULTS AND CHILDREN LIFEJACKETS. 46 CFR 180.78.
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 9 August 2017
Resolution: verified correct markings, cleared def.
Lifesaving › Lifefloat › Lifeline
Issued 28 July 2016
Resolved
Renew life float pendants and lifelines. Renew markings.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 11 August 2016
Resolution: Vessel renewed life float pendants, lifelines, and markings.
Lifesaving › Lifefloat › Paddle
Issued 28 July 2016
Resolved
Provide 01 paddle for lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 1 August 2016
Resolution: new paddle with vessel name marked on it placed on the vessel.
Lifesaving › Lifefloat › Float-free Link
Issued 28 July 2016
Resolved
Renew weak link and make floatfree arrangement.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 11 August 2016
Resolution: Vessel replaced weak link and made lifefloat a float-free arrangement.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 July 2016
Resolved
Renew/provide first aid kit.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 1 August 2016
Resolution: new first aid kit, with all required items, placed on vessel.
Communications › Audible Communications › Horn/Whistle
Issued 28 July 2016
Resolved
Demonstrate satisfactory ship's whistle to attending MI.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 1 August 2016
Resolution: tested ships whistle and operated properly.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 28 July 2016
Resolved
Ensure port side shaft seal is not leaking excessively.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 28 July 2016
Resolution: Shaft seal properly packed.
Electrical › Electric Supply System (service) › Cable
Issued 28 July 2016
Resolved
Remove dead end wires/electrical hazards in engine compartment.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 1 August 2016
Resolution: dead end wiring removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 July 2016
Resolved
Provide guards to flywheels on main engines.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 1 August 2016
Resolution: guards properly installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 28 July 2016
Resolved
Post original COI/Stability letter in visible location.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 1 August 2016
Resolution: original COI/Stability letter placed in sleve visible to passengers on an interior bulkhead.
Stability › Weathertight Integrity › General
Issued 28 July 2016
Resolved
Make port side window weather-tight.
Action required: 705 - Other - as specified
Due 4 August 2016
Resolved 1 August 2016
Resolution: repairs made to window gasket to create weathertight seal.
Stability › Weathertight Integrity › General
Issued 28 July 2016
Resolved
Make elec cable penetration in pilothouse bulkhead weather tight.
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 28 July 2016
Resolution: Filled in with 5200 and made wx tight.
Navigation › Piloting/Steering › Marine Charts
Issued 28 July 2016
Resolved
Provide updated charts for vessel operation.
Action required: 705 - Other - as specified
Due 8 August 2016
Resolved 11 August 2016
Resolution: Vessel provided updated charts for vessel operation.
Construction/Loadline › Hull › Stringer
Issued 28 July 2016
Resolved
Provide repair proposal for wasted deck structual members (longitudals). Proposal and repair to be completed at next drydock.
Action required: 705 - Other - as specified
Resolved 28 July 2016
Resolution: recieved repair proposal.
Lifesaving › Lifebuoys › Serviceable
Issued 28 July 2016
Resolved
Lifebuoy found holed and soiled. Renew.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 July 2016
Resolved 1 August 2016
Resolution: new life buoy placed on vessel and properly marked and taped.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 16 December 2015
Resolved
Verify aft strut bearing.
Condition: Invalid
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 21 December 2015
Resolution: O/O verified with satisfactory results.
Construction/Loadline › Hull › Keel
Issued 16 December 2015
Resolved
Bring back forward starboard keel area to good material and repair as required.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 December 2015
Resolved 21 December 2015
Resolution: O/O ground down, inspected fiberglass, found to be in satisfactory condition, completed repair.
Construction/Loadline › Structures › Deck Plating
Issued 16 December 2015
Resolved
Forward starboad deck outboard, cut back to good material and renew as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 January 2016
Resolution: Verified correction of deficiency.
Construction/Loadline › Structures › Deck Plating
Issued 16 December 2015
Resolved
Forward deck at forepeak access hatch, renew deck as original.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 January 2016
Resolution: Verified correction of deficiency.
Construction/Loadline › Structures › Deck Plating
Issued 16 December 2015
Resolved
Repair delamination to deck port side of pilot house, midship.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 January 2016
Resolution: Verified correction of deficiency.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 16 December 2015
Resolved
Forward compartment, secure wire runs and ladder.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 5 January 2016
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 December 2015
Resolved
Repair port overhead frame in engine room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 December 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Girder
Issued 16 December 2015
Resolved
Repair port deck beam tank compartment in way of access hatch.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 23 December 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Hull › Longitudinal Frame
Issued 16 December 2015
Resolved
Renew port deck frame and rot in steering room.
Action required: 705 - Other - as specified
Resolved 21 December 2015
Resolution: Verified correction of deficiency.
Construction/Loadline › Structures › Deck Plating
Issued 16 December 2015
Resolved
Repair aft starboard corner deck and frame.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 January 2016
Resolution: Verified correction of deficiency.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 January 2012
Resolved
Attach water light to life float with 3/8 inch lanyard at least 18 feet in length, attach around body of life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2012
Lifesaving › Lifefloat › Painter
Issued 25 January 2012
Resolved
Painter for life float must run out freely when life float floats away from a sinking vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2012
Lifesaving › Lifefloat › Paddle
Issued 5 January 2012
Resolved
Provide two 4 foot paddles attached to life float.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 January 2012
Construction/Loadline › Hull › Bottom Plating
Issued 5 December 2011
Resolved
Grind back delaminated fiberglass areas on hull as identified and make available for inspection.
Action required: 705 - Other - as specified
Resolved 8 December 2011
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 December 2011
Resolved
Seal penetration in aft engine room bulkhead starboard side of center.
Action required: 705 - Other - as specified
Resolved 8 December 2011
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 December 2011
Resolved
Splice exposed wire above port battery box in engine room.
Action required: 705 - Other - as specified
Resolved 8 December 2011
Electrical › Electric Supply System (service) › Battery Installation
Issued 5 December 2011
Resolved
Replace missing cap to battery cell in engine room.
Action required: 705 - Other - as specified
Resolved 26 January 2012
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 5 December 2011
Resolved
Make repairs to leaking impeller housing on Port MDE.
Action required: 705 - Other - as specified
Resolved 8 December 2011
Engineering › Reduction Gearing/Clutches › Casing
Issued 5 December 2011
Resolved
Replace wasted and holed gear oil fill cap on starboard MDE
Action required: 705 - Other - as specified
Resolved 8 December 2011
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 26 July 2011
Resolved
Vessel may not carry more than 32 adult passengers. Provide 13 adult life jackets.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 29 August 2011
Navigation › Piloting/Steering › Marine Charts
Issued 26 July 2011
Resolved
Provide updated NOAA marine chart.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 10 August 2011
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 26 July 2011
Resolved
Properly mount main A/C circuit breaker.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 10 August 2011
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 July 2011
Resolved
Properly terminate or remove dead-end cables from radio and switchboard.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 10 August 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 July 2011
Resolved
Provide guards for both main engine flywheels.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 10 August 2011
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 26 July 2011
Resolved
Provide globe for overhead light in the engine room, fwd port side.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 10 August 2011
Electrical › Electrical Distribution System (service) › Junction Box
Issued 26 July 2011
Resolved
Make fwd loudhailer junction box weather tight.
Action required: 705 - Other - as specified
Due 9 August 2011
Resolved 26 July 2011
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 4 August 2008
Resolved
Provide current edition of tidal currents, US Coast Pilot, USCG light list and current/corrected charts onboard.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 12 August 2008
Engineering › Bilge Water Management System › Piping
Issued 4 August 2008
Resolved
Provide suction for fuel/sewage void bilge in correct position (horizontal not vertical).
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 21 August 2008
Engineering › Bilge Water Management System › Strainer
Issued 4 August 2008
Resolved
Provide/replace strainer in fuel/sewage void.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 21 August 2008
Engineering › Bilge Water Management System › Valve
Issued 4 August 2008
Resolved
Replace check valve in bilge line in fuel/sewage void.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 21 August 2008
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 August 2008
Resolved
Replace line on ring buoy (grab line).
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 12 August 2008
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 August 2008
Resolved
Replace waterlight battery and provide proper mounting bracket.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 12 August 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 4 August 2008
Resolved
Replace hose clams on STBD engine.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 4 August 2008
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 4 August 2008
Resolved
Provide mounting bracket for aft fire extinguisher.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 12 August 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 August 2008
Resolved
Put quantity of lifesaving jackets on locker door and quantity of Childs lifejackets on child stowage box.
Action required: 705 - Other - as specified
Due 8 August 2008
Resolved 12 August 2008
Engineering › Steering Gear System › Rudder Bearing
Issued 3 July 2007
Resolved
Provide rudder bearing or repack rudder.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Engineering › Steering Gear System › Rudder
Issued 3 July 2007
Resolved
Repair laceration in port rudder.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Stability › Watertight Integrity › General
Issued 3 July 2007
Resolved
Provide proper gasket for all deck hatches.
Action required: 705 - Other - as specified
Resolved 20 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2007
Resolved
Remove dead end wires through out or properly terminate.
Action required: 705 - Other - as specified
Resolved 20 July 2007
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 3 July 2007
Resolved
Properly repair hole in bow forward of hydraulic hoses.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 3 July 2007
Resolved
Prove proper operation of anchor windlass.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Engineering › Steering Gear System › Rudder Stock
Issued 3 July 2007
Resolved
Provide rudder stops.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Engineering › Bilge Water Management System › Pump
Issued 3 July 2007
Resolved
Prove proper operation of all bilge pumps, primary and secondary.
Action required: 705 - Other - as specified
Resolved 20 July 2007
Construction/Loadline › Structures › End Bulkhead
Issued 3 July 2007
Resolved
Properly seal collision bulkhead.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Construction/Loadline › Structures › Deck Plating
Issued 3 July 2007
Resolved
Properly seal livewell plumbing on deck.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 July 2007
Resolved
Provide means to determine sewage tank 3/4 full.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 July 2007
Resolved
Relocate high water alarm in fuel oil tank void.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 3 July 2007
Resolved
Mount sewage water pump.
Action required: 705 - Other - as specified
Resolved 20 July 2007
Engineering › Fuel Oil Service System › Valve
Issued 3 July 2007
Resolved
Provide access to starboard emergency fuel shutoff valve.
Action required: 705 - Other - as specified
Resolved 12 July 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 3 July 2007
Resolved
Properly secure high water alarm in void #1.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Construction/Loadline › Structures › End Bulkhead
Issued 3 July 2007
Resolved
Make aft bulkhead watertight in void #1
Action required: 705 - Other - as specified
Resolved 18 July 2007
Engineering › Steering Gear System › Piping
Issued 3 July 2007
Resolved
Properly secure hydraulic piping in void #1.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 July 2007
Resolved
Properly secure wire in void #1.
Action required: 705 - Other - as specified
Resolved 20 July 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 3 July 2007
Resolved
Replace flex hose on port MDE water exhaust.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Engineering › Lubricating Oil Service System › Hose
Issued 3 July 2007
Resolved
Replace stbd transmission hydraulic hose.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Engineering › Fuel Oil Service System › Piping
Issued 3 July 2007
Resolved
Properly run fuel line from RAYCOR to stbd MDE.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Operations/Management › Navigation Safety › Arrival/Departure Tests
Issued 3 July 2007
Resolved
Prove proper operation of port MDE.
Action required: 705 - Other - as specified
Resolved 20 July 2007
Construction/Loadline › Structures › Deck Plating
Issued 3 July 2007
Resolved
Provide repair proposal for E/R vent ducts port and stbd.
Action required: 705 - Other - as specified
Resolved 18 July 2007
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2005
Resolved
Three areas on the port bow (as marked) are blistered, soft and are in need of repair. Grind area and expose damage area for inspection before making permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2005
Resolved
Areas on the port keel a midship (as marked) is blistered, soft and in need of repair. Grind area and expose damage area for inspection before making permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 28 June 2005
Resolved
Port cutlass bearing worn and in need of replacement. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Construction/Loadline › Hull › Bottom Plating
Issued 28 June 2005
Resolved
Prior repairs on starboard bow de-laminating. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Engineering › Shafting/Propeller Arrangements › Flange/Thrust Collar Fillet
Issued 28 June 2005
Resolved
Rubber boot on shaft log deteriorated, make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Electrical › Electrical Distribution System (service) › Cable
Issued 28 June 2005
Resolved
Electric wires not proper support in main machinery spaces.
Action required: 705 - Other - as specified
Due 30 June 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 May 2005
Resolved
Adult and child size life jackets need to be properly segregated. They are currently being stowed in the same compartment with no indication as to which space is for adult lifejackets and which are for child size lifejackets.
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 8 August 2005
Resolution: Cleared via e-mail pictures and class docs., CK
Engineering › Sea-water System (primary cooling) › Piping
Issued 27 May 2005
Resolved
Raw water suction hoses are worn on port ans stbd side sea water intakes. Replace raw water suction hoses on port and stbd side through hull fittings.
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 29 June 2005
Resolution: Cleared at Dry Dock. CHK
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2005
Resolved
Dead end and improper wiring throughout the vessel. Ensure all wiring is in accordance with CFR 183.340 and appropriate for marine use. Remove or properly terminate in an electrical box all dead end wires. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Engineering › Bilge Water Management System › Piping
Issued 10 May 2005
Resolved
In accordance with 46CFR182.710 remove all non-ferrous piping from fixed bilge system. In addition, only short pieces of hose for flexibility should be used. Hose lengths must be less than 30 inches unless it is ASME J1942 hose. All hose ends must be doubled clamped. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Engineering › Freshwater Generation System › Piping
Issued 10 May 2005
Resolved
In accordance with 46CFR182.710 remove all non-ferrous piping from main propulsion cooling system piping. In addition, only short pieces of hose for flexibility should be used. Hose lengths must be less than 30 inches unless it is ASME J1942 hose. All hose ends must be doubled clamped. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Engineering › Freshwater System (intermediary cooling) › Hose
Issued 10 May 2005
Resolved
Hose to the exhaust cooling on the port main diesel engine is leaking and cracked. In accordance with 46CFR182.710 only short pieces of hose for flexibility should be used. Hose lengths must be less than 30 inches unless it is ASME J1942 hose. All hose ends must be doubled clamped. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 10 May 2005
Resolved
Portable fire extinguishers not properly mounted in approved brackets. Ensure all portable extinguishers are in approved brackets and readily accessible.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Lifesaving › Lifefloat › Platform
Issued 10 May 2005
Resolved
Ladder to upper deck where the life float and rescue platform are stowed is not fixed or safe. Make primary life saving equipment must be readily accessible. Submit plans for any modification of the vessel prior to commencing the work.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 8 August 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 May 2005
Resolved
The rescue platform in need of repairs. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 May 2005
Resolved
Electrical plug to power reel still not proper. Provide a proper wire run and out let for on deck use. Remove cable from vent and make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 10 May 2005
Resolved
Life jacket locker not proper marked. Make permanent and proper repairs to the satisfaction of the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Stability › Incline Test › General
Issued 10 May 2005
Resolved
Stability letter not readable and in question, provide documentation to prove the validity of the previously conducted test or conduct new test.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 May 2005
Resolved 27 May 2005
Operations/Management › Equipment Service/Testing › EPIRB
Issued 13 July 2004
Resolved
Prove registration of the newly purchased/installed EPIRB.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2004
Resolved 10 May 2005
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 13 July 2004
Resolved
Remove hardwired power reel from battery bank (Direct Wired), or install protection for circuit.
Condition: Improper Installation
Due 13 August 2004
Resolved 10 May 2005
Engineering › Bilge Water Management System › Piping
Issued 13 July 2004
Resolved
Renew wasted bilge piping IWO engine room.
Condition: Unknown
Due 13 August 2004
Resolved 10 May 2005
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 13 July 2004
Resolved
Renew broken bonding wire in way of fuel tank.
Condition: Unknown
Due 13 August 2004
Resolved 10 May 2005
Construction/Loadline › Structures › Superstructure
Issued 13 July 2004
Resolved
Renew broken window in way of bridge/cabin.
Condition: Unknown
Due 13 August 2004
Resolved 10 May 2005
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 13 July 2004
Resolved
Provide access to the life float/upperdeck.
Condition: Design Flaw
Due 10 May 2005
Resolved 10 May 2005
Lifesaving › Buoyant Apparatus › Serviceable
Issued 13 July 2004
Resolved
Repair lifloat puncture.
Condition: Damaged By Earlier Event
Due 13 August 2004
Resolved 10 May 2005
Construction/Loadline › Hull
Issued 18 June 2003
Resolved
Properly grind out to good material and properly repair areas marked on exterior hull by marine inspector LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 26 June 2003
Stability › Weathertight Integrity
Issued 18 June 2003
Resolved
Install coaming on aft cabin door LEGACY COMPONENT DESC: Door Coamings
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 26 June 2003
Construction/Loadline › Penetrations
Issued 18 June 2003
Resolved
Remove all valves on side shell within six inches of deepest load waterline for inspection. LEGACY COMPONENT DESC: Valves
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 26 June 2003
Navigation › Piloting/Steering
Issued 18 June 2003
Resolved
Provide all navigation publications. LEGACY COMPONENT DESC: Navigational Publications
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 26 June 2003
Engineering › Steering Gear System
Issued 18 June 2003
Resolved
Repack rudder shafts with new packing material. LEGACY COMPONENT DESC: Rudder Stock
Action required: 705 - Other - as specified
Due 27 June 2003
Resolved 26 June 2003
Engineering › Bilge Water Management System
Issued 16 June 2003
Resolved
Provide means to dewater compartment fwd of the collision bulkhead LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Documentation › Certificates/Documents
Issued 16 June 2003
Resolved
Properly mount COI and Stability letter under glass or transperant material LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 16 June 2003
Resolved
Provide current service report for fixed firefighting system
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 16 June 2003
Resolved
Ensure distribution line in CO2 system extends 2" past last oriface. Ensure all piping & fittings meet approved specifications LEGACY COMPONENT DESC: Nozzle
Condition: Improper Installation
Due 15 July 2003
Resolved 30 June 2003
Communications › Radio Communications
Issued 16 June 2003
Resolved
Provide current hydostatic release test for EPIRB LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Communications › Radio Communications
Issued 16 June 2003
Resolved
Provide current NOAA registration for EPIRB LEGACY COMPONENT DESC: EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Communications › Radio Communications
Issued 16 June 2003
Resolved
Provide monthly log for testing of EPIRB LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Operations/Management › Drills/Instruction
Issued 16 June 2003
Resolved
Provide emergency instructions to accurately reflect vessel equipment installation LEGACY COMPONENT DESC: Fire
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Operations/Management › Passenger Operations
Issued 16 June 2003
Resolved
Provide a more adequate means for determining passenger count while vessel is underway
Due 25 June 2003
Resolved 30 June 2003
Navigation › Piloting/Steering
Issued 16 June 2003
Resolved
Provide a light for magnetic compass LEGACY COMPONENT DESC: Magnetic Compass
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Communications › Internal Communications System
Issued 16 June 2003
Resolved
Provide a working PA system LEGACY COMPONENT DESC: Public address system
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2003
Resolved 30 June 2003
Operations/Management › Drills/Instruction
Issued 16 June 2003
Resolved
Provide emergency broadcast placard LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Lifesaving › Buoyant Apparatus
Issued 16 June 2003
Resolved
Replace all pendants on life float LEGACY COMPONENT DESC: Pendant
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Lifesaving › Buoyant Apparatus
Issued 16 June 2003
Resolved
Provide a float free link with appropriate rating for installed lifefloat LEGACY COMPONENT DESC: Float free link
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2003
Resolved 30 June 2003
Lifesaving › Buoyant Apparatus
Issued 16 June 2003
Resolved
Provide a floating waterlight for lifefloat LEGACY COMPONENT DESC: Floating waterlight
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Stability › Watertight Integrity
Issued 16 June 2003
Resolved
Provide retaining device for maindeck hatches
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Engineering › Bilge Water Management System
Issued 16 June 2003
Resolved
Provide a portable hand bilge pump LEGACY COMPONENT DESC: Pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Fire Fighting › Fire Pumps
Issued 16 June 2003
Resolved
Provide a hand operated fire pump
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Operations/Management
Issued 16 June 2003
Resolved
Conduct a credit dry-dock prior to carriage of passengers
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2003
Construction/Loadline › Structures
Issued 24 May 2002
Resolved
Repair scuttle dog on forward scuttle. LEGACY COMPONENT DESC: Scuttle
Condition: Damaged By Earlier Event
Due 10 June 2002
Resolved 26 June 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 24 May 2002
Resolved
Repair fuel leak on starboard engine fuel pump. LEGACY COMPONENT DESC: Pump, Positive Displacement
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2002
Resolution: Operator corrected fuel oil leak.
Engineering › Steering Gear System
Issued 24 May 2002
Resolved
Renew/replace steering hose and fittings located in aft compartment with SAE J-1942 hose and fittings. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Improper/Lack of Maintenance
Due 16 June 2002
Resolved 1 May 2003
Construction/Loadline › Hull
Issued 5 March 2002
Resolved
Repair indicated areas of the hull. LEGACY COMPONENT DESC: Bottom Plating
Due 5 March 2002
Resolved 15 March 2002
Construction/Loadline › Structures
Issued 5 March 2002
Resolved
Replace all dogs for watertight hatches on deck. LEGACY COMPONENT DESC: Manhole
Due 5 March 2002
Resolved 15 March 2002
Engineering
Issued 30 May 2001
Resolved
Provide covers for all rotating machinery and belts.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Engineering
Issued 30 May 2001
Resolved
Move Diesel fill pipe to the weather deck.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Engineering
Issued 30 May 2001
Resolved
Move Diesel vents to weather deck.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Documentation
Issued 30 May 2001
Resolved
Provide written statment that addresses the repairs carried out to the maindeck stbd. aft on top of lazarette compartment.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Documentation
Issued 30 May 2001
Resolved
Provide CPR/First aid cards for 50% of the deckhands.
Condition: Unknown
Due 30 May 2001
Resolved 30 May 2001
Documentation
Issued 18 May 2000
Resolved
ALL MASTERS ARE TO OBTAIN AN FCC OPERATORS LICENSE.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Documentation
Issued 21 June 1999
Resolved
Prior to 28Jun99, provide the proper vessels name on all FCC Certificates.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Engineering
Issued 21 June 1999
Resolved
Prior to 28Jun99, repair PORT tachometer gauge.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Electrical
Issued 21 June 1999
Resolved
Prior to 28Jun99, provide metal wire ties for hanging all wires throughout vessel.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 21 June 1999
Resolved
Prior to 28Jun99, provide a proper Employee Assistance Program (IAW 46CFR16.401) and MIS requirements (IAW 46CFR16.500).
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 21 June 1999
Resolved
Prior to 28Jun99, provide a Bilge High Level Alarm System IAW 46CFR182.530.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 21 June 1999
Resolved
Prior to 15Jul99, provide a Fixed Fire Extinguishing & Detecting System IAW46CFR181.400. IF NOT COMPLETED BY THIS DATE, VESSEL'S COI WILL BE REVOKED.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Lifesaving
Issued 21 June 1999
Resolved
Prior to 28Jun99, provide a shepards-pole to assist in person overboard drills.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Lifesaving
Issued 27 January 1999
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, REMOVE AFT BOUYANT APPARATUS (15 PERSONS) FROM VESSEL, OR REPLACE PAINTER, WEAKLINK, AND WATERLIGHT LINE IAW46CFR180.15.5.
Condition: Unknown
Due 28 January 1999
Resolved 28 January 1999
Construction/Loadline
Issued 27 January 1999
Resolved
PRIOR TO 27FEB99, PROVIDE A CHECK VALVE FOR EACH BILGE SUCTION LINE.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Construction/Loadline
Issued 27 January 1999
Resolved
PRIOR TO 27FEB99, MAKE WATERTIGHT, ALL WATER TIGHT BLKHD PENITRATIONS.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Lifesaving
Issued 27 January 1999
Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS, REPLACE PAINTER LINE AND LIGHT LINE TOFWD LIFEFLOAT IAW 46CFR180.15.5.
Condition: Unknown
Due 27 January 1999
Resolved 27 January 1999
Construction/Loadline
Issued 21 May 1997
Resolved
INSTALL PERMANENT CONNECTIONS AT EACH BULKHEAD FOR BILGE PIPING PENETRATIONS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
MAKE BULKHEAD PENETRATIONS OF BILGE LINE WATERTIGHT.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 21 May 1997
Resolved
PROVIDE SUITABLE LADDER/PLATFORM TO RECOVER MAN OVERBOARDS.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Navigation
Issued 21 May 1997
Resolved
PROVIDE CURRENT COAST PILOT, NAV RULES AND CHARTS.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 21 May 1997
Resolved
POST LIFE JACKET PLACARDS.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Documentation
Issued 21 May 1997
Resolved
ESTABLISH COMPANY CHEMICAL TESTING PROGRAM IAW 46CFR16.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Navigation
Issued 21 May 1997
Resolved
INSTALL RF METER FOR VHG RADIO.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Documentation
Issued 21 May 1997
Resolved
ESTABLISH CHEMICAL TESTING PROGRAM FOR ALL CREWMEMBERS IAW 46 CFR 16.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 21 May 1997
Resolved
INSTALL SEPARATOR TO SEPARATE CHILD FROM ADULT LIFEJACKETS.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Documentation
Issued 21 May 1997
Resolved
POST COMPANY CHEM TESTING PROGRAM.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
MAKE PERM REPAIRS TO OVERBOARD DISCHARGE LINE-PORT SIDE FUEL TANK VOID.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
DISASSEMBLE, INSPECT AND CLEANUP FIRE PUMP MANIFOLD AT EACH FLEXIBLE HOSE FITTING AND TIGHTEN/ADJUST MATALLIC COUPLING AT MANIFOLD.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Electrical
Issued 21 May 1997
Resolved
REPLACE PORT BATTERY SELECTOR SWITCH KNOB.
Condition: Unknown
Due 2 June 1997
Resolved 2 June 1997
Lifesaving
Issued 28 September 1994
Resolved
Renew/repair ringbuoy light.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Lifesaving
Issued 28 September 1994
Resolved
Install retro reflective tape on both lifefloats.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Navigation
Issued 28 September 1994
Resolved
Relocate stern light to stern of vessel.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Accommodation/Occupational Safety
Issued 28 September 1994
Resolved
Double clamp raw water suction hoses to toilets.
Condition: Unknown
Due 4 November 1994
Resolved 4 November 1994
Engineering
Issued 28 September 1994
Resolved
Insulate both main engine exhaust lines from the mainfold to the point of raw water injection.
Condition: Unknown
Due 4 November 1994
Resolved 4 November 1994
Construction/Loadline
Issued 28 September 1994
Resolved
Label bilge manifold.
Condition: Unknown
Due 4 November 1994
Resolved 4 November 1994
Construction/Loadline
Issued 20 September 1990
Resolved
CREDIT DRYDOCK DUE 20MAR92. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Lifesaving
Issued 20 September 1990
Resolved
RENEW INSIDE LIFELINES ON BOTH 15 MAN LIFERAFTS. UNTIL COMPLETED, THE VESSEL IS LIMITED TO 48 PASSENGERS (50 TOTAL PERSONS) WITH TEMPORARY 25 MAN FLOAT.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Accommodation/Occupational Safety
Issued 20 September 1990
Resolved
PROVE OPERATION FO BOTH HEADS AND SINKS. UNTIL COMPLETED, VESSEL IS LIMITED TO THE CARRIAGE OF 49 PASSENGERS ON RUNS OF NOT MORE THAN 30 MINUTES.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Construction/Loadline
Issued 27 September 1989
Resolved
REPAIR FIBERGLASS FRACTURES IN STERN DECK. NOT TO BE PUTTY ONLY.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Electrical
Issued 27 September 1989
Resolved
PROVIDE BATTERY BOX PORT.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Engineering
Issued 27 September 1989
Resolved
TIGHTEN LINKAGE BRACKET STBD TRANSMISSION.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Fire Fighting
Issued 27 September 1989
Resolved
PROVIDE SUITABLE HOSES FOR PORTABLE FIRE PUMP.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Engineering
Issued 27 September 1989
Resolved
PROVIDE REMOTE FUEL SHUT OFFS OUTSIDE ENGINEROOM.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989
Resolved
REPLACE RING BUOY GRAB LINE.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Electrical
Issued 27 September 1989
Resolved
REPLACE MISSING/BROKEN LIGHT GLOBES.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Accommodation/Occupational Safety
Issued 27 September 1989
Resolved
REMOUNT SPEAKER OVER CABIN AFT DOOR.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Construction/Loadline
Issued 27 September 1989
Resolved
PROVIDE MISSING DOGS ON ALL DECK HATCHES.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Electrical
Issued 27 September 1989
Resolved
RELOCATE STERN LIGHT AFT.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989
Resolved
STENCIL LIFEFLOAT CAPACITY AND PADDLE WITH VESSEL NAME.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989
Resolved
REPAIR 1 LIFEFLOAT LIGHT.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Lifesaving
Issued 27 September 1989
Resolved
PROVIDE 2 18" LINES FOR LIFEFLOAT LIGHTS.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Navigation
Issued 27 September 1989
Resolved
TIGHTEN PORT SHAFT PACKING.
Condition: Unknown
Due 27 September 1989
Resolved 27 September 1989
Electrical
Issued 4 May 1989
Resolved
PROVE OPERATION OF STEERING, FIREPUMP, MAIN PROPULSION, ELECTRONICS AND TOILETS AND WINDLASS.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Engineering
Issued 4 May 1989
Resolved
REPLACE R/W PICKUP SEA VALVE IN TANK SPACE AND PORT R/W COOLING SEA VALVE &INSTALL SEA VALVES IN STBD SIDESHELL PENETRATIONS IN TANK SPACE AND E/R.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Navigation
Issued 4 May 1989
Resolved
MAKE OPERATIONAL MAST HEAD LIGHT PRIOR TO OPERATING AT NIGHT.
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Navigation
Issued 7 December 1988
Resolved
PROVIDE NEW BATTERY FOR EPIRB. UNTIL COMPLETED ROUTE IS REDUCED TO COASTWISE NO MORE THAN 20 MILES. SUBMIT RECEIPT FOR BATTERY TO MSO TAMPA
Condition: Unknown
Due 7 December 1988
Resolved 7 December 1988
Navigation
Issued 7 June 1988
Resolved
PROVIDE A SINGLE SIDE BAND RADIO PRIOR TO OPERATING MORE THAN 20 MILES OFF-SHORE. CORRECTED BY REDUCING ROUTE TO COASTWISE.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Construction/Loadline
Issued 7 June 1988
Resolved
INSTALL CAPTIVE CHAINS ON ALL WEATHER DECK HATCHES.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Fire Fighting
Issued 7 June 1988
Resolved
MAKE NECESSARY REPAIRS TO ENGINE DRIVEN FIRE & BILGE PUMP PRIRO TO CARRYINGMORE THAN 49 PASSENGERS.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Navigation
Issued 7 June 1988
Resolved
REPLACE THE 6" SHIPS BELL WITH THE REQUIRED 8" BELL.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Navigation
Issued 7 June 1988
Resolved
PROVIDE 6 HAND HELD RED FLARES PROIR TO CARRYING PASSENGERS AT NIGHT.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Accommodation/Occupational Safety
Issued 7 June 1988
Resolved
PROVIDE A WASH BASIN FOR MALE/FEMALE HEADS PRIOR TO CARRYING MORE THAN 49 PASSENGERS.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Unknown
Issued 7 June 1988
Resolved
INSTALL FLAME SCREEN OF 30X30 MESH ON VSL FUEL TANK VENT.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988