MAURY USCG vessel records Sign in
← All vessels

SANTA FE RIG 135

SANTA FE RIG 135 is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 23 inspections since 1985, most recently in November 1991, along with 40 deficiencies.

Records from 1985 to 1991. Most recent: inspection, 20 November 1991.

Built
1983
Last inspected
20 November 1991
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-55277

Inspections, by type

…with no type recorded2
Years with a record 7 calendar years (1985–1991)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 35 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5076 - Regulatory (Subpart C or D), Net Ton
7587 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 23

20 November 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939451
27 November 1990 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914671
4 October 1990 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 916897
29 March 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214390
5 January 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 907596
9 October 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909256
19 June 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1350977
16 May 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202694
15 January 1989 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202975
21 September 1988 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1199964
4 January 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326968
1 December 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335210
1 November 1987 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021407
11 May 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021155
9 December 1986 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1022489
4 December 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024067
4 December 1986 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1026400
7 November 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1013939
29 October 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1318420
3 July 1986 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 989627
13 May 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 997112
18 September 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 993004
17 June 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 979192

Deficiency record · 40

Lifesaving
Issued 4 October 1990 Resolved
PLACE ON BOARD PORTABLE LIFEBOAT RADIO (MESSING) AND ENSURE PROPER OPERATION NOT LATER THAN 04DEC90.
Condition: Unknown
Due 5 December 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 4 October 1990 Resolved
PROVIDE COMPLETE COPY OF VSL'S FIREFIGHTING EQUIPMENT SERVICE REPORT AND REPORT OF FOAM ANALYSIS OF HELO DECKS FIXED FOAM SYSTEM FOR SERVICING COMPLETED 02-04 OCT 90 BY CTEAC.
Condition: Unknown
Due 4 October 1990
Resolved 4 October 1990
Construction/Loadline
Issued 9 October 1989 Resolved
PROVIDE COPY CONSTRUCTION PORTFOLIO ONBOARD VESSEL.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Electrical
Issued 9 October 1989 Resolved
REPAIR THE FOLLOWING ELECTRICAL CONNECTIONS IN #1S CAISSON: V201, 263 AND 230.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Deck/Cargo
Issued 9 October 1989 Resolved
PROPERLY SECURE FLEX HOSES FOR DECANTER CENTRIFUDGE LOCATED IN THE MUD PIT ROOM.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Deck/Cargo
Issued 9 October 1989 Resolved
PROVE PROPER OPERATION OF EMERGENCY SHOWER LOCATED OUTSIDE MUD PIT ROOM.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Deck/Cargo
Issued 9 October 1989 Resolved
PROVIDE PROPER VENT DUCTING IN WELDING SHOP.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Fire Fighting
Issued 9 October 1989 Resolved
REPAIR VENT CLOSURE JUST OUTSIDE PAINT LOCKER.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Construction/Loadline
Issued 9 October 1989 Resolved
WTD LEADING FROM SHALE SHAKER AREA BLOCKS OUTSIDE WALKWAY AND ESCAPE ROUTE WHEN OPENED. PROVIDE TO MIO NY PLANS TO MODIFY SAID DOOR.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Engineering
Issued 9 October 1989 Resolved
PROVIDE PROPER SAFETY RELIEF VALVES WITH HAND RELIEVING DEVICE FOR THE POTABLE WATER SURGE TANK, STBD LOWER HULL WINCH A/R AND L/P COMPRESSORS.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Electrical
Issued 9 October 1989 Resolved
REWIRE AND SUBMIT PLANS TO MIO NY FOR THE REWIRING OF THE ESSENTIAL EMERGENCY TRIP SO THAT ONE COOLING PUMP FOR THE D/6 SETS REMAINS OPERATIONAL.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Electrical
Issued 9 October 1989 Resolved
REWIRE EMERGENCY TRIP FOR MAIN/EMERGENCY GENERATORS, WHICH IS LOCATED ON THE DRILL FLOOR, SO THAT THEY ARE NOT LOCATED IN SAME LOCATION (SAME SWITCH).
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Lifesaving
Issued 9 October 1989 Resolved
SERVICE ALL 4 LIFE RAFTS PRIOR TO 15 DECEMBER 1989.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Lifesaving
Issued 9 October 1989 Resolved
RENEW FALLS AND CONDUCT WEIGHT TEST OF BOTH DAVITS FOR LIFE RAFTS.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Fire Fighting
Issued 9 October 1989 Resolved
RECHARGE AND HAVE HYDRO CONDUCTED ON 15 LB HALON BOTTLE FOR STBD THRUSTER.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Fire Fighting
Issued 9 October 1989 Resolved
PROVIDE SERVICING REPORT FOR PORTABLE AND FIXED FIRE FIGHTING EQUIPMENT.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Navigation
Issued 9 October 1989 Resolved
REPAIR AND PROVE PROPER OPERATION OF AUTOMATIC WHISTLE LOCATED IN PILOT HOUSE.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Navigation
Issued 9 October 1989 Resolved
REPAIR AND PROVE PROPER OPERATION OF OBSTRUCTION LIGHT LOCATED ON TOP OF DERRICK.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Electrical
Issued 9 October 1989 Resolved
REPAIR AND PROVE PROPER OPERATION OF PURGE AIR SYSTEM AND ALARMS LOCATED ON THE DRILL FLOOR.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Electrical
Issued 9 October 1989 Resolved
REPAIR & PROVE PROPER OPERATION OF THE FOLLOWING GENERAL ALARMS BELLS: MOONPOOL; STBD HELO FOAM UNIT; FWD CEMENT UNIT; MUD PUMP RM; SHALE SHAKER RM; 85 FT FLAT #25 CAISSON; 4 BELLS IN STBD LOWER HULL AND ONE IN PORT LOWER HULL.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Fire Fighting
Issued 9 October 1989 Resolved
PROVIDE THE REQUIRED EQUIPMENT FOR THE FIRE STATION LOCATED IN THE SHALE SHAKER ROOM LOWER LEVEL.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Electrical
Issued 9 October 1989 Resolved
ALARM FOR PRESSURE DEFFERENTIAL BETWEEN MUD PIT ROOM AND MUD PUMP ROOM SHOULD BE REWIRED SO THAT WHEN THE ALARM SOUNDS IT REQUIRES A MANUAL RESET.
Condition: Unknown
Due 9 October 1989
Resolved 9 October 1989
Construction/Loadline
Issued 15 January 1989 Resolved
PROVIDE TO [name withheld] A COPY OF THE NDT CRITICAL JOINT TEST REPORT AND THE DIVERS UNDERWATER HULL SURVEY WITH A COPY OF THE VIDEO.
Condition: Unknown
Due 15 January 1989
Resolved 15 January 1989
Accommodation/Occupational Safety
Issued 1 November 1987 Resolved
MAKE PERMANENT REPAIRS TO STEAM PIPING FOR ACCOMMODATIONS HEATING SO SYSTEMWILL MEET HEATING REQ. AS PER 46 CFR 108.213 ELEC. SPACE HEATERS MAY BE UTILIZED FOR TEMP. HEATING OF ACCOM. SPACE HEATERS SHALL NOT OVERLOAD EXISTING ELEC. CIRCUITS & MUST BE LOCATED TO PREVENT INJURY TO CREW MBRS.
Condition: Unknown
Due 1 November 1987
Resolved 1 November 1987
Engineering
Issued 1 November 1987 Resolved
CONDUCT HYDROSTATIC TEST OF NEWLY INSTALLED STEAM PIPING TO 1 1/2 MAWP.
Condition: Unknown
Due 1 November 1987
Resolved 1 November 1987
Fire Fighting
Issued 1 November 1987 Resolved
INSTALL AND PROVE PROPER OPERATION OF HALON SHUTDOWNS FOR MAIN GENERATORS.
Condition: Unknown
Due 1 November 1987
Resolved 1 November 1987
Engineering
Issued 1 November 1987 Resolved
CONDUCT HYDROSTATIC TEST OF ALL (3) HEATING BOILERS TO 1 1/4 MAWP.
Condition: Unknown
Due 1 November 1987
Resolved 1 November 1987
Engineering
Issued 1 November 1987 Resolved
PROVE PROPER OPERATION OF EMERGENCY ALARMS AND SHUT DOWNS OF #2 BOILER AND SET SAFETY VALVES. BOILER SERIAL NUMBER 22042.
Condition: Unknown
Due 1 November 1987
Resolved 1 November 1987
Unknown
Issued 4 December 1986 Resolved
SUBMITTED PLANS FOR ALTERATION TO BILGE DRAIN SYSTEM.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Unknown
Issued 29 October 1986 Resolved
REPAIR/REPLACE THE FOLLOWING DOORS TO PROVIDE A SECURE FIT AND PROPER OPER-ATION:PORT FWD WINCH HUT,STBD FWD WINCH HUT,BOTH DOORS TO DOGHOUSE,BOTH DOORS TO MUD PIT ROOM,BOILER ROOM TO WAREHOUSE,BOILER ROOM TO COMPRESSOR FLATS,CHANGE ROOM,STBD BRIDGE TO MAIN DECK,EMER GEN ROOM,& HELO WAIT DECK.
Condition: Unknown
Due 29 October 1986
Resolved 29 October 1986
Electrical
Issued 13 May 1986 Resolved
PROVIDE AND INSTALL PROPER COVERS OVER OPEN AREAS IN ELECTRICAL PANELS P212C AND P-446 IN MAIN GENERATOR ROOM.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Lifesaving
Issued 13 May 1986 Resolved
PROVIDE PROPER SMOKE SIGNALS FOR BOTH LIFEBOATS.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Engineering
Issued 13 May 1986 Resolved
SUBMIT PLANS FOR CHANGES TO BILGE DRAIN SYSTEM TO OCMI,NEW YORK.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Construction/Loadline
Issued 13 May 1986 Resolved
REPAIR/REPLACE THE FOLLOWING DOORS TO PROVIDE A SECURE FIT AND PROPER OPER-ATION;PORT FRED WINCH HUT,STBD FWD WINCH HUT,BOTH DOORS TO DOGHOUSE,BOTH DOORS TO MUD PIT ROOM,BOILER ROOM TO WAREHOUSE,BOILER ROOM TO COMPRESSOR FLATS,CHANGE ROOM,STRBD BRIDGE TO MAIN DECK,EMERG GEN ROOM,HELO WAIT DECK.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Fire Fighting
Issued 13 May 1986 Resolved
OBTAIN SAMPLE OF FIREFIGHTING FOAM FROM EACH ONBOARD FIXED FOAM SYSTEM AND HAVE SAME ANALYZED FOR SPECIFIC GRAVITY,PH, % WATER DILUTION, SOLID CONTENTAND ADEQUACY FOR SERVICE AND SUBMIT REPORT TO [name withheld] PRIOR TO 30JUN86.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Deck/Cargo
Issued 13 May 1986 Resolved
REPAIR ELEVATOR CUTOUT SWITCHES AND DEMONSTRATE PROPER OPERATION OF SAME.
Condition: Unknown
Due 13 May 1986
Resolved 13 May 1986
Unknown
Issued 18 September 1985 Resolved
MAKE PERM. REPAIR INWAY OF TEMP. REPAIR TO SEA WATER COOLING LINE LOCATED IN DRILL WATER TANK #4S.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Electrical
Issued 17 June 1985 Resolved
REWIRE EMERGENCY GENERATOR SHUTDOWN FROM HALON SYSTEM 80 THAT SOLENOIDS ON AIR MANIFOLD ARE OPERATED UPON HALON RELEASE.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Engineering
Issued 17 June 1985 Resolved
REMOTE SHUTDOWN ON ALL THREE BIR'S MUST BE REWIRED TO ENABLE ALL POWER TO BE CUT-OFF FROM CONTROL PACKAGE AS WELL AS BIR.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985
Accommodation/Occupational Safety
Issued 17 June 1985 Resolved
RENEW ALUMINUM DECKING IN GENERATOR WITH STEEL DECKING.
Condition: Unknown
Due 17 June 1985
Resolved 17 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.