Records from 2016 to 2025. Most recent: inspection, 9 December 2025.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Documentation record
Registered dimensions (L × B × D)60.7 ft × 19.8 ft × 5.3 ft
Registered tonnagegross 56 / net 38
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLYDIA YACHTS INC. · STUART, FL, UNITED STATES · built 1974
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portHARWICH PORT, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Gross Ton
38 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
9 December 2025
Administrative Inspection
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8279825
12 June 2025
COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8113961
11 February 2025
In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8078118
17 December 2024
Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8048885
16 October 2023
Internal Structural Exam · Drydock Exam · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7809522
16 July 2023
Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 7744220
16 July 2023
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7786182
23 November 2022
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7601909
6 December 2021
Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7363920
16 November 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7358395
23 November 2020
COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7096724
4 December 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6866863
15 October 2019
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6834416
13 November 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6579370
13 November 2017
Drydock Exam · DAPI Audit · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6306676
14 November 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6040361
14 November 2016
DAPI Audit
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6041207
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 June 2025
Resolved
Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. The clip must have a strength of at least 22.7 kilograms (50 pounds), and allow the waterlight to be quickly disconnected from the ring life buoy. Vessel corrected on the spot.
46CFR 180.70.d.3.
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 12 June 2025
Resolved 12 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 12 June 2025
Resolved
If the vessel carries more than one life float or buoyant apparatus in a group with each group secured by a single painter ...The vessel's life floats are arranged for tandem launching. Provide individual painters to weak link or properly installed tandem line to the satisfaction of the attending USCG MI prior to the carriage of passengers.
46CFR 180.137.e.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2025
Resolved 13 June 2025
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 June 2025
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. Vessel's fire extinguishers are not mounted. Provide proper installation to the satisfaction of the attending USCG MI prior to the carriage of passengers.
46CFR 181.520
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2025
Resolved 13 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 12 June 2025
Resolved
The maximum number of passengers permitted must be not more than that allowed by the requirements of this section, except as authorized by the OCMI under paragraph (d) of this section ...The vessel's passenger seating has been removed for maintenance. Current COI authorizes 49 passengers. Provide proof and count criteria IAW regulation cited to the satisfaction of the attending USCG MI prior to the carriage of passengers.
46CFR 176.113
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2025
Resolved 13 June 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 June 2025
Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. Life jackets are to be stored onboard the vessel IAW the cited regulation. Provide installation to the satisfaction of the attending USCG MI prior to the carriage of passengers.
46CFR 180.78
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2025
Resolved 13 June 2025
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 June 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards ...The 12v house battery and all of the vessels distribution, breaker and junction panels (to include deadfront covers 46CFR 183.330) shall be installed and maintained to the satisfaction of the attending USCG MI within 14 days of this issued 835v.
46CFR 183.200
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 13 June 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 June 2025
Resolved
Cocks are prohibited except for the solid bottom type with tapered plugs and union bonnets. The fuel filter/water separator assemblies have the factory cocks installed. Vessel shall remove and install solid mechanical plugs to the satisfaction of the attending USCG MI within 14 days of this issued 835v.
46CFR 182.455.a.3.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 June 2025
Resolved 1 July 2025
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 12 June 2025
Resolved
The vessel shall provide proof of registration with the FCC for radio installation and vessel call sign designation, within 30 days of this issued 835v.
47CFR 80
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2025
Resolved 17 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 February 2025
No resolution recorded
46 CFR 176.500(b)(1) Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. (i) You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. Vessel's annual inspection window will expire while vessel is in transit to its new operating zone, vessel must contact the cognizant OCMI upon arrival and schedule its overdue inspection. Vessel may not transit to its new OCMI zone with passengers on board.
Action required: 701 - Prior to carriage of passengers/cargo
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 November 2023
No resolution recorded
On a vessel of at least 26’ in length a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: a machinery space, a space with a through hull fitting, a space with a non-water tight closure. Vessel's "rudder room" and "engine room" indicator would not illuminate, only produce sound.
Action required: 16 - Rectify deficiencies w/in 14 days
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 10 November 2023
No resolution recorded
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 47 CFR 80.1101(c)(2). VHF radio on board does not have MMSI number nor location capabilities installed per 47 CFR 80.905(a)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 November 2021
Resolved
Found (2) small holes in port wood strut mounts due to wood borers; repaiar to the satisfaction of the attending marine inspector. Prior to Dry dock credit.
Action required: 705 - Other - as specified
Resolved 29 November 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 November 2021
Resolved
Damage was found around both exhaust ports and a softball size scuff in the gel coat on the transom. Two gussets on the deck frames in the lazarette were found rotted out supporting main deck beams and excessive angel hair was found in the engine room and tank space. All marked areas to be ground back to good fiberglass and repaired prior to credit dry-dock.
46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 29 November 2021
Resolution: Repaired to the satisfaction of the attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 December 2019
Resolved
Replace worn tape(retro-reflective)with SOLAS approved retro-reflective tape on 7 identified life jackets.
46 CFR 180.25-25
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2019
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 5 December 2019
Resolved
Replace DOT reflective tape on life floats with SOLAS approved retro reflective tape.
46 CFR 176.25-20(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2019
Resolution: Corrected.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 December 2019
Resolved
Replace or remove broken light base in engine compartment on aft bulkhead.
46 CFR 183.05-45(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2019
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 November 2016
Resolved
Found 21 lifejackets in unserviceable condition; deteriorated and waterlogged. Reduced PAX count to 28. 46 CFR 180.25-5
Due 28 November 2016
Resolved 23 November 2016
Resolution: Vessel owner purchased 21 new lifejackets.
Lifesaving › Lifebuoys › Serviceable
Issued 14 November 2016
Resolved
Renew ring life-buoy as original; found deteriorated and worn. 46 CFR 180.30-5
Due 28 November 2016
Resolved 16 November 2016
Resolution: Renewed as orig.
Electrical › Electric Supply System (service) › Battery Installation
Issued 14 November 2016
Resolved
Make permanent terminal connection on batteries on bridge and compartment #3 (fuel tank compartment). Found in improper connections. 46 CFR 183.05
Action required: 705 - Other - as specified
Due 28 November 2016
Resolved 16 November 2016
Resolution: Permanent connections made to battery terminals.
Engineering › Reduction Gearing/Clutches › Seal
Issued 14 November 2016
Resolved
Repair starboard engine transmission hydraulic pump; found with severe oil leak. 46 CFR 182.05
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 November 2016
Resolution: Replaced hydrolic pump as original.