TREASURE STAWINNER

TREASURE STAWINNER is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 31 inspections since 1984, most recently in March 1992, along with 98 deficiencies.

Records from 1984 to 1992. Most recent: inspection, 18 March 1992.

Built
1983
Last inspected
18 March 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-55294

Inspections, by type

…with no type recorded6
Years with a record 9 calendar years (1984–1992)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it9243 - Regulatory (Subpart C or D), Net Ton
9608 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 31

18 March 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 958901
19 February 1992 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 952577
18 January 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23491
12 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221992
20 February 1991 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 918053
30 November 1990 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 923955
16 November 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237019
5 November 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931511
16 October 1990 Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933458
23 August 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247831
7 March 1990 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223561
21 November 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915333
17 October 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348573
28 July 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042422
13 July 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042003
13 July 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340013
12 May 1988 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1194188
8 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018622
16 July 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308756
15 June 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316141
21 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017215
28 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319692
30 December 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316009
25 August 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012576
25 August 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012732
20 June 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998021
21 May 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995427
25 July 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990471
14 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990969
28 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980810
7 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977622

Deficiency record · 98

Lifesaving
Issued 19 February 1992 Resolved
PROVIDE REFLECTIVE TAPE FOR ALL LIFEBOATS AND RING BUOYS AS PER SOLAS REQUIREMENTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
PROVIDE CHAIN TO NIPPLE CONNECTION FOR HOSE NOZZLE ON FIRE STATIONS #2, 4, 3, 10, 11, 16, 12, 49, 32, 28, 35, 31, 43, 42, 24, 30, 41, 36, 19 AND 23._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
INSTALL PURGE TO TOP DRIVE MONITOR LOCATED NEXT TO DRILLER'S CONSOLE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REMOVE DEAD END WIRING UNDER DRILL FLOOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROPERLY MOUNT HEAT SENSOR IN SHAKER HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
INSTALL SAFETY LEASE TO LIGHT ABOVE SINK IN SHAKER HOUSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPLACE ARMOR CABLE TO RENTAL MUD CLEANER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REATTACH WITH METAL BANDING THE WIRE LOCATED ABOVE THE DEGASSER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 February 1992 Resolved
RENEW RING BUOY LOCATED AFT PORT BY #2 LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
RENEW CORRODED ELECTRIC WIRE BRACKETS FOR EMERGENCY LIGHT WIRE ON #2 LIFEBOAT EMBARKATION STATION._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPACK WIRE TO THE JUNCTION BOX LOCATED ABOVE THE DOOR BY SINK IN THE MUD PITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPACK WIRE TO THE JUNCTION BOX LOCATED BELOW THE INTAKE FAN IN THE MUD PITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROPERLY MOUNT JUNCTION BOX ON #2 MUD PUMP STROKE COUNTER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPLACE MISSING GLOBE FOR THE LIGHT IN #4 THRUSTER ROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPAIR ROTATING LIGHT ON #1 EMD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPAIR REVERSE POWER RELAY ON #4 EMD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
PROVIDE "O" RING FOR NOZZLE NIPPLE ON FIRE STATIONS #2, 9, 11, 10, 16, 12, 50, 32, 42, 43, 30, 41, 36 AND 19._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROPERLY RUN WIRING AND REMOVE DEAD END WIRING UNDER HELO DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 February 1992 Resolved
RENEW BROKEN GLASS ON GENERAL ALARM CONTACT MAKER BY #3 LIFEBOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
RELABEL #49 FIRE STATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
REPAIR #14 FIRE STATION FOR OPERATIONAL TEST._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROPERLY HANG ELECTRIC WIRE RUNNING TO LOUDSPEAKER LOCATED ON THE BOP ROOM OUTSIDE FORWARD BULKHEAD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPAIR ORANGE LANDING LIGHT ON HELO DECK BY STBD STAIRWAY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
MAKE APPROVED REPAIRS TO PORT SALT WATER SERVICE PIPE IN AREA OF DOUBLER PATCHES IN PORT PUMP ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROPERLY HANG NEW ELECTRIC WIRE RUNNING DOWN PORT AFT COLUMN TO BOS'N STORAGE LOCKER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
REPAIR LEAKING VALVE ON FIRE STATIONS #18, 22, 36, AND THE ONE IN THE BOS'NSTORAGE LOCKER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
MAKE APPROVED REPAIRS TO SALT WATER PIPE RUNNING TO CONDENSER UNIT IN AREA OF DOUBLER PATCHES LOCATED IN STBD FORWARD COLUMN._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 19 February 1992 Resolved
REMOVE ALL EQUIP AND OTHER ITEMS NOT DIRECTLY RELATED TO THE NEEDS AND/OR REQUIREMENTS OF A HOSPITAL SPACE FROM SAME AS PER 46 CFR 108.209._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 February 1992 Resolved
PROVIDE OPERATING INSTRUCTIONS FOR LINE THROWING APPLIANCE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 19 February 1992 Resolved
PROVIDE THE VESSEL FIRST AID KIT WITH EIGHT 4" COMPRESSES, EIGHT 2" COMPRESSES, ONE RUBBER BLANKET, ONE TOURNIQUET, AND RENEW ALL EXPIRED MEDICATION._x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 19 February 1992 Resolved
PROVIDE RESULT OF FIRE FIGHTING FOAM SAMPLE ANALYSIS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROPERLY MOUNT JUNCTION BOX PRESENTLY LAYING IN CABLE TRAY BY STAND PIPE MANIFOLD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPAIR SUBSEA MONITOR'S PURGE SWITCH LOCATED IN BACKROOM ON DRILL FLOOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPAIR WATER COOLER JUNCTION BOX ON DRILL FLOOR. REPACK WIRE CONNECTION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 February 1992 Resolved
PROVIDE HAND FLARES (12), MONKEY FIST ON HEAVING LINE, LIGHTS AND WHISTLE _x001C_ON LIFE JACKETS, TOOL KIT, AND 35 ADDITIONAL WATER BAGS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROVE EMBARKATION LIGHT FOR #1 LIFEBOAT IS ON THE EMERGENCY BUS AND LABEL._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 February 1992 Resolved
RENEW LINES ON STBD FORWARD CORNER RING BUOY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 19 February 1992 Resolved
RENEW RING BUOY LOCATED STBD AMIDSHIP AFT OF FUEL OIL TRANSFER STATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
PROPERLY HANG LOOSE ELECTRIC WIRING LOCATED AT FORWARD DAVIT SUPPORT ON #3 LIFEBOAT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
RENEW CORRODED ELECTRIC WIRE BRACKETS FOR #3 LIFEBOAT WINCH CONTROL WIRE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 19 February 1992 Resolved
OPEN FOR INTERNAL INSPECTION ALL TENSION BOTTLES NOT INSPECTED DURING THIS VISIT AS NOTED IN INSPECTION RECORD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REMOVE THE 3M SCOTCH CAST SPLICE LOCATED ABOVE HYDROMATIC BRAKE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 19 February 1992 Resolved
PROVIDE ANNUAL SURVEY FOR IOPP CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPACK THE CENTER WIRE TO THE JUNCTION BOX ABOVE THE DOOR TO THE MUD PITS._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 19 February 1992 Resolved
REPLACE MISSING SCREW TO THE SWITCH BOX NEXT TO THE GENERAL ALARM BELL IN THE MUD PITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 March 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 30 November 1990 Resolved
PERFORM WEIGHT TEST OF BOTH DAVITS, LAUNCH LIFE RAFT STATION DAVITS.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Engineering
Issued 30 November 1990 Resolved
PROVE PROPER OPERATION OF #2 GENERATOR, LOW 40 PRESSURE
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Fire Fighting
Issued 30 November 1990 Resolved
PROVIDE A FOAM ANALYSIS, REPORT TO [name withheld], TEXAS
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Engineering
Issued 30 November 1990 Resolved
PROVE PROPER OPERATION OF DRILLERS CONSOLE, PURGE AIR ALARM.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 7 March 1990 Resolved
SERVICE #2 AND #4 LIFERAFTS (D/L) AND THE BOW DAVIT HOOK PRIOR TO PUTTING A FULL COMPLIMENT OF PERSONEL ABOARD THE RIG.
Condition: Unknown
Due 7 March 1990
Resolved 7 March 1990
Electrical
Issued 13 July 1989 Resolved
PROPERLY HANG THE CABLES IN THE MUD PUMP ROOM.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
POUR ALL THE EYS FITTINGS BEHIND THE DATA LOG SHACK ENSURING THAT WIRES ARE SEPERATED.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
PULL THE DEAD IN CABLE ON THE DRILL FLOOR BY THE SWACO UNIT OR MAKE A PROPER ENDING WITH A JUNCTION BOX AND POURED EYS FITTING.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
SEAL AND TIGHTEN THE BULKHEAD CABLE PENETRATING FOR THE BAROID SHACK ON THESHALE SHAKER.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
POUR ALL THE EYS FITTINGS FOR THE SERVICE EQUIPMENT IN THE MUD PIT ROOM.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
RENEW THE 1/4" STEEL AND PLASTIC THE WRAPS THROUGHOUT THE VESSEL WITH CORROSION RESISTANT TIE WRAPS OF SUFFICIANT WIDTH AS TO NOT CUT THROUGH THECABLE.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Accommodation/Occupational Safety
Issued 13 July 1989 Resolved
INSTALL CHAINS AT BOAT LANDING, EMARKATION AREA.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Accommodation/Occupational Safety
Issued 13 July 1989 Resolved
MAKE VENTILATION, ENGINE AND RIG SHUTDOWNS AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Fire Fighting
Issued 13 July 1989 Resolved
MAKE THE FIRE AND GAS DETECTION SYSTEM AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
SECURE CAMERA IN SHALE SHAKER AREA OR SHAW APPROVAL FOR USE IN HAZARDOUS AREA (CLASS I DIV I) FOUND CAMERA BOX PURGED BUT DOES NOT COMPLY WITH TYPE X PURGING AS REQUIRED BY NFPA 496. MUST SHUT DOWN POWER TO CAMERA WHEN PURGE IS LOST.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
MAKE #1,#2,#3,AND #4 EMERGENCY GENERATORS AVAILABLE FOR OVERSPEED TRIP, LOWOIL PRESSURE, HIGH WATER TEMPERATURE, AND REVERSE POWER RELAY TESTS IN THE PRESENCE OF A U.S.C.G. MARINE INSPECTOR.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Accommodation/Occupational Safety
Issued 13 July 1989 Resolved
MAKE ALL AIR RECIEVERS BULK/CEMENT TANKS AND HIGH PRESSURE VESSELS AVAILABLE FOR INTERVAL INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
MAKE HAZARDOUS LOCATIONS INCLUDING DRILL FLOOR, SHALE SHAKER AREA AND DRILLFLOOR SUBSTRUCTURE AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Lifesaving
Issued 13 July 1989 Resolved
SHOW APPROVAL FOR THE LIFEBOAT WINCH DRUMS WHICH ARE DOUBLE WRAPPED WITH WIRE.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Documentation
Issued 13 July 1989 Resolved
HAZARDOUS AREA DRAWING DOES NOT COMPLY WITH REGS. SHOWS DRILL FLOOR CLASS IDIV I OTHER AREAS NOT NORMALLY SHOWN ARE SHOWN AS HAZARDOUS. PLEASE REVIEW DRAWING FOR ACCURACY.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Lifesaving
Issued 13 July 1989 Resolved
REPLACE BOTH PERSONNEL BASKET.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
CHANGE JUNCTION BOX IN BATTERY ROOM, USE BOX UL, FM OR CSA APPROVED FOR CLASS I DIV I GROUP B ATMOSPHERE 46CFR 111.15-5 GENERAL ALARM STRIKEN NEEDES TO BE GROUP B AS WELL.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
POUR ALL EYS FITTINGS IN BATTERY ROOM (ALL EMPTY AT JUNCTION BOX).
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
INSTALL EYS FITTING ON JUNCTION BOX TO MOTOR FOR BATTERY ROOM BLOWER MOTOR.SHOW HAZARDOUS PLUM AROUND VENT ON HAZARDOUS AREA PLAN.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Deck/Cargo
Issued 13 July 1989 Resolved
TAYLOR DIVING, INSTALL REMOTE FUEL SHUTDOWN FOR SKID GENERATOR.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Electrical
Issued 13 July 1989 Resolved
TAYLOR DIVING INSTALL RUBBER MAT IN FRONT OF GENERATOR SWITCH BOARD.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Construction/Loadline
Issued 15 June 1987 Resolved
PAINT DRAFT MARKS AND LOADLINES ON SIDES OF HULL PLATING. SEE 46CFR 107.231(A) 4
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987
Deck/Cargo
Issued 20 June 1986 Resolved
PROVIDE SEVEN AIR PRESSURE RELIEF VALVES SET AT NOT MORE THAN 2400 PSI FOR THE DSC AND RISER TENSIONING AIR RECEIVERS. VALVES SHALL BE TESTED IN PRESENCE OF THE COAST GUARD.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Engineering
Issued 20 June 1986 Resolved
REPAIR THE TUBE NEST IN NO. 2 BOILER AND CONDUCT HYDRO TEST AND RELIEF VALVE TEST IN PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 20 June 1986
Resolved 20 June 1986
Electrical
Issued 25 July 1985 Resolved
RESET OVERSPEED TRIP ON EMERGENCY GENERATOR AT NOT OVER 15 PERCENT OF RATEDRPM. 46 CFR 58.10.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Accommodation/Occupational Safety
Issued 25 July 1985 Resolved
TEST RELIEF VALVES ON TENSIONER BOTTLES IN PRESENCE OF A COAST GUARD MARINE INSPECTOR. 46 CFR 61.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Construction/Loadline
Issued 25 July 1985 Resolved
RENEW SUCTION PRESSURE GAUGE ON S(1) BALLAST PUMP. 46 CFR 56.50.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Lifesaving
Issued 25 July 1985 Resolved
PROVIDE LIFEBOAT WINCH THAT WILL COMPLY WITH 46 CFR 160.015-2(B). NO DOUBLE WRAPING OF WIRE.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Construction/Loadline
Issued 25 July 1985 Resolved
RENEW SUCTION PRESSURE GAUGE ON P(1) BALLAST PUMP. 46 CFR 56.50.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Construction/Loadline
Issued 25 July 1985 Resolved
PROVIDE A NON-SKID SURFACE ON HELICOPTER LANDING DECK. REF 46 CFR 108.235.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Fire Fighting
Issued 25 July 1985 Resolved
MAKE OPERABLE THE FIRE AND GAS ALARM SYSTEM. REF 46 CFR 108.405.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Unknown
Issued 25 July 1985 Resolved
REPAINT THE LOAD LINE. REF 46 CFR 108.663.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Construction/Loadline
Issued 25 July 1985 Resolved
PROVIDE APPROVAL CONSTRUCTION PORTFOLIO ON BOARD VESSEL. REF 46 CFR 107.305.
Condition: Unknown
Due 25 July 1985
Resolved 25 July 1985
Unknown
Issued 7 September 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PENROD 78 DN655023
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Documentation
Issued 7 September 1984 Resolved
OBTAIN FROM THE [name withheld] A PERMANENT STABILITY LETTER AND PLACE IT ON BOARD THE RIG. 46CFR93.15
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Fire Fighting
Issued 7 September 1984 Resolved
PROVIDE TWO ADDITIONAL FIREMAN OUTFITS AS PER THE APPROVED FIRE CONTROL PLAN OR MODIFY THE PLAN AND SUBMIT APPROVAL. 46CFR108.497
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Fire Fighting
Issued 7 September 1984 Resolved
PROVIDE TWO APPROVED 4 FOOT LOW VOLOCITY SPRAY APPLICATORS FOR THE MACHINERY SPACES. 46CFR162.027 *FOOTNOTES.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Unknown
Issued 7 September 1984 Resolved
REMOVE THE NON-APPROVED FORKLIFT FROM THE RIG ANY REPLACEMENT MUST BE MADE WITH AN APPROVED TYPE OF FORKLIFT. 46CFR108.(A)(B)
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Unknown
Issued 7 September 1984 Resolved
REMOVE THE 5-100 FOOT LONG FIRE HOSES FROM THE RIG AND REPLACE THEM WITH 2 50 FT LENGTH, OF FIR EHOSE. 46CFR108.425
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Electrical
Issued 7 September 1984 Resolved
REPAIR THE LOW LUBE OIL ALARM FOR THE GENERATOR DRIVES NUMBERS 2,3, AND 4 46CFR107.231
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Unknown
Issued 7 September 1984 Resolved
PROVIDE HEAT RESISTANT FLOW SIGHT GAGES FOR ALL OF THE FUEL OIL DAY TANKS. 46CFR58.50.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Electrical
Issued 7 September 1984 Resolved
REMOVE ALL OF THE BRASS FITTINGS FROM THE FUEL OIL DAY TANKS. 46CFR56.50.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Unknown
Issued 7 September 1984 Resolved
PROVIDE THE RELIEF VALVES FIRE MAIN AND FOAM EXTINGUISHING BETWEEN THE PUMP AND THE DISCHARGE VALVES. 46CFR108.417
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Electrical
Issued 7 September 1984 Resolved
ON THE DRILL FLOOR MAKE THE FOLLOWING ELECTRICAL EQUIPMENT SUITABLE FOR DIVISION II HAZARDOUS LOCATIONS: (4) GENERAL ALARM BELLS, THE (2) LIGHT PANEL CURCUIT BOARDS AND THE (2) 480 VOLT PLUGS.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Electrical
Issued 7 September 1984 Resolved
MASTER BLOWN OUT PREVENTOR PANEL, HOOK PERCENT GAGE, WESTON GAGE, GENERAL ALARM CONTACT MAKER, AND THE SOUND POWERED PHONE ALARM LIGHT, UNDERWATER TELEVISION CONTROL BUTTON. 46CFR11.105
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Electrical
Issued 7 September 1984 Resolved
PROVIDE A GENERAL ALARM BELL AND LIGHT SUITABLE FOR DIVISION I HAZARDOUS LOCATIONS IN THE SHALE SHAKER. 46CFR111.105
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Electrical
Issued 7 September 1984 Resolved
PROVIDE TWO GENERAL ALARM BELLS SUITABLE FOR DIVISION II HAZARDOUS LOCATIONIN THE MUD PIT. 46CFR111.105.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984
Electrical
Issued 7 September 1984 Resolved
PROVIDE A GENERAL ALARM BELL APPROVED FOR HAZARDOUS LOCATIONS IN THE BATTERY ROOM. 46CFR111.105.
Condition: Unknown
Due 7 September 1984
Resolved 7 September 1984

Ownership record