CREOLE QUEEN

Built
1983
Last inspected
9 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 March 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5102
Flag
UNITED STATES
Maury page id
psix-55298

Documentation record

Registered dimensions (L × B × D)162.7 ft × 38.0 ft × 7.7 ft
Registered tonnagegross 397 / net 275
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHALTER MARINE, INC · MOSS POINT, MS, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Electric
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 31 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it397 - Regulatory (Subpart C or D), Gross Ton
275 - Regulatory (Subpart C or D), Net Ton
532 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 57 inspections, each with its date, unit and type; 104 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 57

9 March 2026 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8318544
9 December 2025 Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8268530
9 September 2025 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8230136
17 June 2025 Deficiency Check · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8150915
25 May 2025 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8146944
24 May 2025 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8143927
19 March 2025 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8096368
30 December 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8051792
29 December 2024 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8063033
9 December 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8036988
20 September 2024 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8006050
16 September 2024 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7990949
10 July 2024 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7953725
8 July 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7952814
17 June 2024 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7936985
18 March 2024 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7881276
12 December 2023 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7829078
7 September 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7786804
5 June 2023 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7703563
27 February 2023 Deficiency Check · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7642266
10 January 2023 Deficiency Check · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7619591
8 December 2022 COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7600472
27 October 2022 Drydock Extension
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7584847
19 September 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7552593
7 June 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7470847
29 April 2022 Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7441059
15 March 2022 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7405735
22 November 2021 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7355640
15 September 2021 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7307485
15 August 2021 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7290663
1 June 2021 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7212457
4 March 2021 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7150436
10 December 2020 COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7098689
18 September 2020 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7053125
20 August 2020 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7038130
26 June 2020 Periodic Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6984133
25 February 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6915095
12 December 2019 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6870488
18 September 2019 Periodic Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6809967
27 June 2019 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6709847
25 March 2019 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6642527
17 December 2018 MTSA Verification · COI Inspection · In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6587042
14 December 2018 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6599150
14 December 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6628141
17 September 2018 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6542628
19 July 2018 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6485416
25 June 2018 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6456655
8 March 2018 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6368662
16 November 2017 Deficiency Check · COI Inspection · In-Service Inspection · Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6308287
21 August 2017 MTSA Verification · Administrative Inspection · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6242616
30 May 2017 MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6154560
28 March 2017 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6110490
13 December 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6056207
19 September 2016 Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6000637
2 June 2016 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5887463
16 March 2016 MTSA Verification · Periodic Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5833081
6 January 2016 Damage Survey · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5792392

Deficiency record · 104

09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 March 2026 Resolved
If your vessel's Certificate of Inspection is renewed annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, at each inspection for certification. The safety relief valve for the horn pressure vessel was last tested 3FEB2023. 46CFR61.10-5(i)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 18 March 2026
Resolution: All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 9 March 2026 Resolved
Door frames shall be of rigid construction, and shall provide at least a 1/2 inch door stop at the sides and top, except; Double swing doors, where permitted, may have a maximum clearance of 1/8 inch at the tops and sides. reefer space doors excedded this limit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 5 April 2026
Resolution: All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 March 2026 Resolved
As an alternative to the rescue boat required in § 199.202, vessels may carry a rescue boat meeting the requirements of part 160, subpart 160.056. Bungholes were found cracked and or missing on rescue boat. 46CFR 160.056-1(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 2 April 2026
Resolution: All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 9 March 2026 Resolved
The inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in a satisfactory condition. Relief valve on hot water tank was not routed to the bilge. 46CFR56.50-25(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 18 March 2026
Resolution: All Sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 March 2026 Resolved
The inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in a satisfactory condition. Wastage was found in multiple areas around the vessel. Port bow rail, reefer room floor, soda storage room floor, serve locker door base plate. 46CFR 71.30-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 5 April 2026
Resolution: All sat.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 9 March 2026 Resolved
The inspector shall examine all accessible parts of the vessel's hull, machinery, and equipment to be assured that it is in a satisfactory condition. Insulation in crew only room near fire station 7 was found torn and wasted. 46CFR 71.30-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 18 March 2026
Resolution: All sat.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 9 December 2025 Resolved
All deficiencies were to be rectified to the satisfaction of the USCG inspector and to be completed within 14 days. Deficiency #1: The deck under the Kings Room Bar is getting wasted, clean and determine the extent of rust/wastage. For all three deficiencies, determine the condition of the areas and make temp repairs for weather tightness and give a written repair proposal with time frame to make repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 8 July 2026
Resolution: Deck fixed and renewed.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 9 December 2025 Resolved
All deficiencies were to be rectified to the satisfaction of the USCG inspector and to be completed within 14 days. Deficiency #2 Queens Room door in the "Syrup Room" at the bottom is wasted through and the deck in the room is questionable. Provide repair proposal for the wasted frame and determined the condition of the deck. For all three deficiencies, determine the condition of the areas and make temp repairs for weather tightness and give a written repair proposal with time frame to make repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 8 July 2026
Resolution: Deck fixed and renewed
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 9 December 2025 Resolved
All deficiencies were to be rectified to the satisfaction of the USCG inspector and to be completed within 14 days. Deficiency #3: Top Deck Mardi Gras Bar outer blkhd fwd. Bottom of blkhd wasted through, provide repair proposal for this area as well. For all three deficiencies, determine the condition of the areas and make temp repairs for weather tightness and give a written repair proposal with time frame to make repairs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2025
Resolved 8 July 2026
Resolution: Deck fixed and renewed.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 17 June 2025 Resolved
17Jun25: On 16Jun25 it was reported by the Master and Chief Engineer of the vessel that the EDG Auto switch was not working properly and generator function was impaired. Make proper repairs to the unit prior to getting the vessel underway and demonstrate to the USCG when repaired.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2025
Resolved 17 June 2025
Resolution: A new Voltage regulator installed in the EDG Switchboard. Tested satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2025 Resolved
A survey, either general or partial, according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel or the efficacy or completeness of its lifesaving appliances, fire-fighting or other equipment, or whenever any important repairs or renewals are made. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, that the material and the workmanship of such repairs or renewals are in all respects satisfactory, and that the vessel complies in all respects with the regulations in this subchapter. - 46 CFR 71.40-1(a) Vessel reported an allision with a partially submerged log that became lodged in the starboard side wheel, vessel immediately returned to home dock. Vessel must provide damage assessment and repair plan prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 29 May 2025
Resolution: Vessel provided proof of satisfactory repairs.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 19 March 2025 Resolved
§ 72.01-15 Structural standards. (a) In general, compliance with the standards established by the American Bureau of Shipping, see subpart 70.35 of this subchapter, will be considered satisfactory evidence of the structural efficiency of the vessel. However, in special cases, a detailed analysis of the entire structure or some integral part may be made by the Coast Guard to determine the structural requirements. There is possible deck wastage behind the Creole Room Bar by the void hatch. Cut away deck covering IWO the Rusted Deck. Clear all rust build up and provide a gauge report for the entire area around the hatch as discussed with the vessel master. Provide the report VIA email to [email withheld]. This is to be accomplished by 02Apr25. (Two Weeks). Possible repairs are pending the results of the gauging report.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2025
Resolved 3 April 2025
Resolution: Gauge Report satisfactiry, scanned into document file.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 December 2024 Resolved
Battery box located outside pilot house requires replacement. Currently it is holed at bottom and internally corroded excessively. 46 CFR 111.15-10(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 December 2024
Resolved 27 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 December 2024 Resolved
#1 SSDG turbo charger oil hose and or other fittings leaking oil. Repair/replace hose and fittings on turbo charger. Complete repair(s) prior to operating the #1 SSDG. 46 CFR 61.20-3(a)
Action required: 705 - Other - as specified
Resolved 27 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 9 December 2024 Resolved
#1 SSDG F/O line leaking. Replace this F/O line, re-install lagging on turbo. Complete repair(s) prior to operating the #1 SSDG. 46 CFR 61.20-3(a)
Action required: 705 - Other - as specified
Resolved 27 December 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2024 Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship's service load under normal operational conditions. Vessel's #1 generator became inoperable. Provide tech report attesting to proper operation of #1 generator to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2024
Resolution: Receieved, reviewed, and accepted tech report attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2024 Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship's service load under normal operational conditions. #1 generator became inoperable. Vessel is permitted one time voyage on 19SEP2024 with the following restrictions. 1. Vessel must notify VTS and confirm traffic prior to crossing river, departure and arrival. 2. Master must provide letter stating reduced power will not imped safe operation of vessel 3. Chief Engineer must provide letter stating vessel reduced propulsion speed will allow vessel to operate propulsion, vital systems, and hotel services on a single generator.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 September 2024
Resolution: Receieved, reviewed, and accepted tech report attesting to repairs.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 12 December 2023 Resolved
Each temporary source of emergency power must consist of a storage battery of sufficient capacity to supply the temporary emergency loads for not less than one-half hour. During loss of power, the public address system's battery backup was only able to provide 1 minute of use. Uninterpretable power supply (UPS) was showing a fault light. Repair or replace UPS with adequate battery life prior to departure. 46 CFR 112.37 (1982 Amended)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 December 2023
Resolved 12 December 2023
Resolution: UPS were replaced, power was tested sat.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 December 2023 Resolved
AIS must be maintained in effective operating condition. AIS was found with intermittent power loss and flickering. Troubleshoot and make appropriate repairs prior to departure. 33 CFR 164.46(d)(2)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 12 December 2023
Resolved 12 December 2023
Resolution: AIS was rewired, witnessed no flickering or power loss.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 12 December 2023 Resolved
Overcurrent protective devices must be installed so that a short-circuit on a circuit that is not vital to the propulsion, control, or safety of the vessel does not trip equipment that is vital. Electrical components under pilothouse console was found with multiple daisy-chained power strips and makeshift power cable tied into back of receptacle outlet. Furthermore, these powerstips were providing power to AIS, Throttle lights and miscalaneous non vital components such as microwave. Remove all unnecessary components such as daisy-chained power strips. Re-wire or move location of AIS and throttle control lights to a vital powers source. Survey all electrical components and breakers for overloaded circuits. Remove all stored items such as cleaning supplies from console.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2023
Resolved 26 December 2023
Resolution: All electrical hazards found under the console was addressed and rewired appropriately.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 12 December 2023 Resolved
Doors, other than those which are normally locked shall be of self closing type capable of closing against a 3.5 degree list. Generator room port and STBD escape trunks were found with missing self closing mechanism as per fire plan. Re-install self closing mechanisms.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2023
Resolved 26 December 2023
Resolution: Crew installed self-closing mechanisms to both doors. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 12 December 2023 Resolved
Except as provided in paragraphs (b) through (d) of this section, this subpart applies to vessels with watertight doors in bulkheads that have been made watertight to comply with the flooding or damage stability regulations in this subchapter. Aft port steering pump room water tight door was found with hinge bushing failure and dogs unable to operate without the use of pipe. Top left dog was found loose and not making proper contact with seat. Make appropriate repairs to door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 December 2023
Resolved 26 December 2023
Resolution: Crew installed new dogs and adjusted door accordingly. All SAT.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 21 September 2023 Resolved
Each general emergency alarm signal must be an electrically-operated bell, klaxon, or other warning device capable of producing a signal or tone distinct from any other audible signal on the vessel. General alarm bell on the identified port side bow of super structure was not working as designed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2023
Resolved 26 September 2023
Resolution: Video recieved. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 21 September 2023 Resolved
A receptacle outlet must not have any exposed live parts with the plug opening uncovered. MI discovered an outlet missing a cover in the vessel’s lower galley. Install appropriate cover on the outlet and submit objective evidence to the satisfaction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2023
Resolved 22 September 2023
Resolution: Pictures recieved. All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 21 September 2023 Resolved
Electric installations on vessels must ensure: Protection of passengers, crew other persons, and the vessel from electrical hazards. MI found an open space with a missing blanking plate in the oven circuit panel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2023
Resolved 22 September 2023
Resolution: Pictures recieved. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 21 September 2023 Resolved
Each passenger vessel of less than 500 tons gross tonnage must carry at least one rescue boat approved under approval series 160.156. MI discover cracking/ splitting on a transom support bracket.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2023
Resolved 26 September 2023
Resolution: Pictures of transom repair recieved. Repair completed by Buck Keihs. Transom support was welded in place. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 21 September 2023 Resolved
Double doors capable of independent operation and latching may have a clearance between the doors not to exceed 1/8 inch. However, if one door must always be closed first, a doorstop of at least 1/2 inch shall be provided for the second door. MI found fire doors with out the center latch mullion post installed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2023
Resolved 22 September 2023
Resolution: Pictures recieved. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 21 September 2023 Resolved
Each item of lifesaving equipment carried on board the vessel in addition to those required by this part must— (2) Be accepted by the cognizant OCMI for use on the vessel. MI discovered adult life jacket location signs were blocked from the field of view.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2023
Resolved 6 October 2023
Resolution: Recieved pictures of relocated adult life jacket signs.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 5 June 2023 Resolved
835 issued: Replace broken window in the passenger compartment on the main deck Port side last window in the passenger seating area. Until repaired, mark off the area to prevent passengers from using the seating at the window.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2023
Resolved 11 July 2023
Resolution: Window Replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 February 2023 Resolved
The vsl shall have a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. The vsl's [name withheld] were not sure which valve needed to be opened to dewater the forepeak. Vsl shall post a bilge diagram & label valves below the deckplates with tags or stenciling above the deckplates to show their location.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2023
Resolved 21 March 2023
Resolution: Verified.
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 6 February 2023 Resolved
Pressure Vessels shall have detailed plans that include the information required by 46 CFR 54.01-18, the plans shall be certified by a registered P.E. to meet the design requirements of 46 CFR 54.01-5(d),(e) & ASME VIII. The vsl shall submit the plans to the local OCMI for review & approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2023
Resolved 21 March 2023
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 January 2023 Resolved
Vsl to make repairs and/or provide for examination to the items as noted on the work list issued to the Master on 23 Jan 23.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 January 2023
Resolution: All repairs were completed to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2022 Resolved
The data shall be stamped directly on the pressure vessel. The data shall be legibly stamped and shall not be obliterated during the service life of the pressure vessel. This plate shall be securely attached to the pressure vessel. The nameplate shall be maintained in a legible condition such that it may be easily read. The data plate on the pressure vessel on the upper deck is no longer legible, replace pressure vessel during next dry-docking in January 2023. 46 CFR 54.10-20(c)
Action required: 705 - Other - as specified
Resolved 6 February 2023
Resolution: A new Pressure Vessel was installed, leak test & operational test was SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 December 2022 Resolved
Whenever doubt exists as to the safety of an existing boiler, pressure vessel, or piping system, the marine inspector may require that it be gauged or checked to determine the extent of deterioration, and if necessary for safety may require the recalculation and reduction of the maximum allowable working pressure. The 02 pressure vessel in the bow thruster room were found with questionable corrosion, provide U1A form with specifications for corrosion allowance an conduct gauging of pressure vessel during next dry-docking in January 2023. 46 CFR 50.05-5(a)
Action required: 705 - Other - as specified
Resolved 9 January 2023
Resolution: Satisfactory U1A received and compared to current UT readings, Tanks are satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 September 2022 Resolved
During the test of the E-Gen shore power was not disconnected and the MI observed flashing and knocking at the E-Gen panel. Ch. Eng stated this was due to the shore power not being disconnected at the time of the switchover and was a result of residual power in line. Test was re-done successfully in which the shore line was disconnected and done on ship power only. Issued deficiency for an electrician to verify system is installed as originally designed and that there is no faulty equipment in system.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 October 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 September 2022 Resolved
Vessel does not have an acknowledgment of enrollment of an ASP, as prescribed in 33 CFR 104.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 October 2022
Resolved 4 October 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2022 Resolved
vsl reported loss of propulsion.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 May 2022
Resolved 1 May 2022
Resolution: Attended vsl to examine repairs and conducted sea trials. All systems sat.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 March 2022 Resolved
46CFR71.65-5(d) (1 thru 7) Fire control. (1) Fire control diagram showing location and type of all required fire-screen insulation, including main fire zone and subdivisions, stairway and elevator enclosures, control space enclosures, etc., and type of all doors in such subdivisions and enclosures. (2) Comprehensive typical details of fire-screen insulation of both vertical and horizontal surfaces, including deck coverings where used, keyed by reference numbers to the “fire control diagram”. (3) Ventilation diagram including dampers and other fire control features. (4) Alarm systems. (5) Detecting systems. (6) Extinguishing systems, including fire main, carbon dioxide, clean agent, foam, and sprinkling systems. (7) Supervised Patrol Route. The vessels current fire control plan is an older issue in black and white with outdated symbols and missing important information such as deck and blkhd classing. Time has come to update the plan to include the new symbols and what is missing from this original plan IAW the above CFR requirement. To be Rectified prior to the next quarterly inspection. INFO contact [name withheld] [phone withheld].
Action required: 705 - Other - as specified
Due 8 June 2022
Resolved 4 October 2022
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 15 March 2022 Resolved
33CFR164.35 Equipment on all vessels: 33CFR164.35(f)An illuminated rudder angle indicator in the wheelhouse. The rudder angle indicator located in the pilot house (2each) and the one located in the Engine room Control station are not reading the same rudder angle. At times the one in the pilot house constantly moves approx 5 to 7 degrees back and forth for a while. Correct the deficiencies between all indicators and determine the cause for the fluctuation in the pilot house that stops after a few minutes. This should be corrected within the next three days by 18Mar2022.
Action required: 705 - Other - as specified
Due 29 March 2022
Resolved 30 March 2022
Resolution: Rep provided tech reports for the recalibration and testing of the rudder angle indicators.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2021 Resolved
Firemain systems installed IAW 46CFR76.10 must be maintained in good working order. Currently several fire hydrant valves are leaking by excessively and on valve could not be opened. Make proper repairs and or replacements to these fire hydrant valves and demonstrate to the satisfaction of the USCG Marine Inspector. Prior to carrying and Passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2021
Resolved 9 December 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 November 2021 Resolved
Diesel Fuel systems installed IAW 46CFR56.50-75 shall be maintained so that no leaks are present in the systems. Currently there are two Fuel lines leaking, one on the number 1 Main Generator and one on the number 2 generator. Replace these leaking lines and demonstrate to the USCG inspector the satisfactory operation of these engines. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 December 2021
Resolved 9 December 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 September 2021 Resolved
General. Each vessel must carry a life jacket for each person on board. While onboard, MIs condemned 41 adult lifejackets and 9 child lifejackets. Prove that the total required amount of lifejackets is onboard, prior to carrying more than 785 adults and 78 children as passengers.
Action required: 705 - Other - as specified
Resolved 12 October 2021
Resolution: Received proof that all condemned lifejackets have been replaced, stenciled and are onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 15 September 2021 Resolved
The method of donning lifejackets. Replace life jacket donning instructions on the 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2021
Resolution: Donning instructions were replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 September 2021 Resolved
Each hand portable fire extinguisher shall be marked with a number and the location where stowed shall be marked with a corresponding number at least 1/2 inch high. Where only one type and size of hand portable fire extinguisher is carried, the numbering may be omitted. Several fire extinguishers are missing. Replace all fire extinguishers to their intended location.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 October 2021
Resolution: Fire extinguishers were replaced
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 1 June 2021 Resolved
Where extinguishing systems or equipment are not required, but are installed, the system or equipment and its installation must meet the requirements of this part. Remove or recharge the fire extinguisher on the main deck p/s adjacent to the midships bar.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2021
Resolution: Received documentation from Master stating 835 is rectified.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 June 2021 Resolved
Marine charts of the area to be transited, published by the National Ocean Service, U.S. Army Corps of Engineers, or a river authority that - (i) Are of a large enough scale and have enough detail to make safe navigation of the area possible; and (ii) Are currently corrected. Provide corrected charts for the area normally transited or prove current arrangement meets specification.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 June 2021
Resolution: Received documentation from Master stating 835 is rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2021 Resolved
Safety or relief valves on pressure vessels: If your vessel's COI is renewed annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, at each inspection for certification. Chief Engineer stated that relief valves have not been tested as per the regulation. Provide documentation attesting to the proper function of the relief valves or renew.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 June 2021
Resolution: Received documentation from Master stating 835 is rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2021 Resolved
Test procedures documents must be in a step-by step or checkoff list format. Each test instructions must specify equipment status, apparatus necessary to perform the tests, safety precautions, safety control and alarm sets points, the procedure to be followed, and the expected test results. Chief Engineer conducted Jacket-water and lube-oil high temp alarms using a fry-daddy. Provide proper testing equipment as per manufacture recommendations.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 June 2021
Resolution: Received documentation from Master stating 835 is rectified.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 18 September 2020 Resolved
Means shall be provided for stopping all fans in ventilation systems serving machinery and cargo spaces and for closing all doorways, ventilators and annular spaces around funnels and other openings to such spaces, from outside these spaces, in case of fire. Both port and starboard engine room ventilation closures were found missing gaskets. Replace all missing gaskets prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2020
Resolved 18 September 2020
Resolution: Vessel crew replaced all gaskets. All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 18 September 2020 Resolved
Each Class 1 door must have a quick action closing device operative from both sides of the door. Bow thruster door handle was found severely loose, causing concern of falling off. CE stated that they may be able to tighten the handle. However it appears to have a shaft key type set up that may be causing the problem as well. Make appropriate repairs IAW manufacturers specifications.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 20 September 2020
Resolution: Crew made appropriate repairs to door handle. All SAT
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 September 2020 Resolved
Exhaust pipe installations must conform to the requirements of ABYC P-1 and part 1 of section 23 of NFPA 302 (both incorporated by reference). #3 generator turbo lagging was not designed for specific application on the turbo, exposeing many areas of turbo and exhaust. Install lagging to adequately cover turbo and exhaust such as the #1 and #2 lagging.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2020
Resolved 30 September 2020
Resolution: Exhaust lagging was repaired. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 September 2020 Resolved
Fire Hose stowage bracket is mounted to the bow thruster door and was found with no adequate means of holding the fire nozzle. Because of this, the fire nozzle was found laying on the deck creating both a tripping hazard and possible future failure of nozzle assembly. Furthermore the spanner wrench was found sitting on an overhead beam creating a hazard to crew and possible loss of wrench falling into bilge. Create a bracket to hold both nozzle and spanner wrench.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2020
Resolved 22 September 2020
Resolution: Crew installed a nozzle bracket. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 26 June 2020 Resolved
Anchor line at anchor chain connection is growing green grass, cut back anchor line and re-splice line to the chain prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2020
Resolved 29 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 June 2020 Resolved
2)Replace 06 Adult life jackets prior to carriage of full complement of passengers, currently only allowed (Non COVID Rules) 820 until new life jackets placed on board.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2020
Resolved 1 July 2020
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 26 June 2020 Resolved
3)Gangway shackles loose and spins when gangway is moved by wave action. Properly fasten pin and shackle prior to getting underway.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2020
Resolved 1 July 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 26 June 2020 Resolved
4)Install an emergency light in the engineer’s workshop aft of the ECR room currently none in there.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2020
Resolved 1 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 26 June 2020 Resolved
5)During the test of the fire hoses one failed. All hoses were tested and found that only one failed, replace the failed hose. Prior to getting underway.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 10 July 2020
Resolved 1 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 February 2020 Resolved
A survey either general or parital according to the circumstances, shall be made every time an accident occurs or a defect is discovered which affects the safety of the vessel. The survey shall be such as to insure that the necessary repairs or renewals have been effectively made, and that the vessel complies in all respects with the regulations of this subchapter. Vessel reported a loss of starboard drive to means of propulsion (paddle wheel) and moored safely at Poydras Dock. Vessel is not permitted to move until starboard drive and all associated equipment is inspected and tested to the satisfaction of a CG marine inspector, and a technicians report is provided detailing the cause of the casualty. CITE: 46 CFR 71.40-1
Action required: 60 - Rectify deficiencies prior to movement
Resolved 27 February 2020
Resolution: USCG observed satisfactory replacement of stbd clutch and underway operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2019 Resolved
Currently the STBD SS/DG has a serious F/O leak at the H/P F/O pump distribution block. Repair all F/O leaks prior to using this SS/DG.
Action required: 705 - Other - as specified
Resolved 19 September 2019
Resolution: Witnessed proper repair/replaced leaking parts to the high pressure fuel oil pump distribution block. No more leakage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2019 Resolved
Currently the Center SS/DG has serious F/O leakage at the H/P F/O pump distribution block and at the #4 and #6 Cylinder head F/O line connections. Repair all F/O leaks prior to using this engine.
Action required: 10 - Deficiency Rectified
Due 18 September 2019
Resolved 18 September 2019
Resolution: While onboard, the crew was able to rectify the leaks. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2019 Resolved
Currently the Port SS/DG has F/O lines that have worn rub spots significantly, Replace all worn F/O lines prior to using this engine.
Action required: 10 - Deficiency Rectified
Due 18 September 2019
Resolved 18 September 2019
Resolution: While onboard, crew was able to replace worn fuel lines to rectify the def. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 December 2018 Resolved
A power-driven vessel of less than 12 meters in length may, in lieu of the lights prescribed in paragraph (a) of this Rule, exhibit an all-around white light and sidelights. Rescue boat under 12 meters on board was found with no navigation lights of any kind.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 December 2018
Resolved 17 December 2018
Resolution: Received photographic documentation attesting to cleared deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 September 2018 Resolved
Grab line around life floats is deteriorated. Replace with new line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2018
Resolved 22 October 2018
Resolution: Replaced lines on life floats with new ones.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 September 2018 Resolved
47 adult and 6 child life jackets are deteriorated. Replace with new ones.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2018
Resolved 22 October 2018
Resolution: New Life jackets were purchase ans placed in service to replace all the ones that were deterorated.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 24 September 2018 Resolved
Maintain main deck galley fire doors free from obstructions.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 24 September 2018
Resolved 24 September 2018
Resolution: Cleared walkway and fire doors were able to close.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 24 September 2018 Resolved
Fuel fill coffer dams missing plugs. Provide appropriate plugs to prevent fuel discharge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2018
Resolved 22 October 2018
Resolution: Plugs were procured and installed on the port and Stbd. cofferdams.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 24 September 2018 Resolved
Vent closure sensor on main deck engine intake vents not properly installed. Install sensor correctly.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2018
Resolved 22 October 2018
Resolution: New bracket was installed and ventillation switch was mounted in place as designed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2018 Resolved
Emergency remote fuel shutoff valves (Port and Starboard) not properly marked and missing the tools required to access and operate them. Provide proper markings and tool for access and operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 October 2018
Resolved 22 October 2018
Resolution: Installed new placards on both sides of vessel. Fabricated tools for the access and proper operation of the fuel shut off valves.
Stability › Watertight Integrity › General
Issued 25 June 2018 Resolved
Readjust watertight door to make water tight. Make available a cheater bar to tighten dogs. Pipe was missing from door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 24 September 2018
Resolution: Confirmed watertight door operates correctly.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 25 June 2018 Resolved
Renew missing door handle from fire screen door on the aft exit from the 02 caterers locker.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 July 2018
Resolved 24 September 2018
Resolution: Confirmed the proper installation.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 December 2017 Resolved
The 2nd deck bar has excessive water building up on the deck, determine the source of the water and correct problem.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Reactured water filter under the bar reapired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 18 December 2017 Resolved
Stairway both decks the bottom "Ginger Bread" railing missing, whats left is and HAZD bracket, remove HAZD or repalce "Ginger Bread" railing section.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Ginger bread rail replaced. HAZD Removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
The 2nd Deck aft bar electrical wires are all taped up, determine why they are and make repairs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Obsolete wires which were removed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
There are dead end wires aft 2nd deck bar in cabinet, properly dead end wires.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Properly dead ended in a junction box.
Accommodation/Occupational Safety › Potable Water System › General
Issued 18 December 2017 Resolved
On the aft bar 2nd deck the sink that is mounted to the ice machine is not mounted properly and is a hazd. Properly repair the sink mounting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Sink removed and new one installed on bar counter top behind bar.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
The room that is next to fire station number 7, there are dead end cables located in that room, properly dead end these cables in junction boxes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Cables determined to be obsolete and they were removed.
Fire Fighting › Structural - A Class Divisions › Store-rooms
Issued 18 December 2017 Resolved
In the store room next to fire station number 7 there is missing fire protection insulation on the blkhd, replace missing insulation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Insulation replaced and repaired.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
In the 2nd deck galley stbd side behind refer machinery, a dead end cable is sitting on the deck in water. Properly remove the wire or dead end in junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Obsolete wire removed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 December 2017 Resolved
Fire damper fwd second deck stbd side in cabinet is tight when operated, free up the damper to operate properly.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Maintenance on daper freed up movement.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 December 2017 Resolved
Exterior doors missing door handles, they were removed for painting and have not been installed, missing screws to install them.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: New screws purchased and handles installed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 December 2017 Resolved
The ventilation openings above the CO2 protected bow thruster room can not be closed. Examine and make repairs so dampers be closed, 03 each one Plrt and 1 stbd, then 1 fwd.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Operation of the dampers is what was not understood by crew, training was completed and dampers operate properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
Main deck port side fwd cabinet two electrical boxes (LIVE) not mounted and one with live wire pulled out of the box. Repair same and properly mount the boxes.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 December 2017
Resolved 20 December 2017
Resolution: Boxes mounted and wires repaired.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 18 December 2017 Resolved
Labels identifying # of lifejackets are missing from starboard side 02 deck.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Information stenciled to outside of container.
Fire Fighting › Structural - A Class Divisions › Flammable Liquids Storage Spaces
Issued 18 December 2017 Resolved
Determine where insulation and fire protection is required in the liquor room.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: C/E provided clarification on requirement for the space.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
Remove dead end wiring behind transformer behind lower deck kitchen. Make transformer termainal connections available for inspection.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Dead end wiring was removed.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 18 December 2017 Resolved
Fire dampers in steering room, fwd Creole kitchen (lower deck), port top inoperable, also near fire station #7. (As identified to ship's crew.) Make fire dampers operable.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Fire dampers were freed and proved operational to attending inspectors.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
Stuffing tubes leading from SCR to generator room (port side of door) are not being kept up properly. Has dead end wires and holes where wires were removed. Clean up, remove wires, and make vapor tight.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Wire run was cleaned up and wires were properly enclosed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 December 2017 Resolved
Door missing from breaker box in tool room. Replace.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Door reinstalled.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 December 2017 Resolved
Area behind panels in SCR being used as storage. Remove all unneccessary equipment from area.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Storage items removed from area.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 18 December 2017 Resolved
Life ring stowed outside of EDG is not marked with vessel name. Mark with vessel name.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: RLB marked properly.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 December 2017 Resolved
Housekeeping in tool room is inadequate: items being stowed on top of transformers & excessive amount of flammable liquids stowed inside space. Clear off transformer and remove any flammable liquid in excess of what is needed for immediate use.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Excessive flammable items removed and equipment removed from transformer.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 December 2017 Resolved
Overhead light covers in tool room & SCR are in poor condition (fractured) & secured with zip ties. Replace.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Covers replaced.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 December 2017 Resolved
Replace primary stern light.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Primary stern light replaced.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 18 December 2017 Resolved
Label all circuit breaker panels on bridge for ship's equipment.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Labels were renewed with up-to-date information.
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 December 2017 Resolved
Dead end wire on wheelhouse deck aft must be removed, tagged out, or connected properly.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Wire removed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 December 2017 Resolved
Replace #3 generator fuel gauge.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Replaced fuel gauge.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 December 2017 Resolved
Replace #3 generator expansion joint as shown to Chief Engineer.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Expansion joint replaced.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 December 2017 Resolved
Install caps/plugs on all generator low lube oil testing valves.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: New caps installed on all valves.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 December 2017 Resolved
Replace zip ties in overhead wire runs located throughout the engine room.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 20 December 2017
Resolution: Plastic zip ties replaced with metal.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2017 Resolved
1. In the [name withheld] upper deck, FWD BLKHD on the deck, there are two 1.5" holes that have been recently cut in the deck to pass new audio and visual cable through. These are improper penetrations in the deck. Properly install wires through approved through BLKHD penetrations. Compliance 27Dec2017.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 December 2017
Resolved 13 December 2017
Resolution: Contractor removed cables and shipyard renewed deck. Proper wire runs were fitted to allow passage of necessary cables.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2017 Resolved
2. [name withheld] upper deck, FWD BLKHD where a cut out in the BLKHD was found where there are questionable wire repairs done. Remove electrical tape and determine the type repair completed and make proper approved repairs to these wires. Compliance date 27Dec2017.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 December 2017
Resolved 13 December 2017
Resolution: Shipyard completed proper splicing of wires.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2017 Resolved
3. Upper deck OVHD AFT on the open deck, there are permanent extension cords installed. Remove same and install proper wire and outlets. Compliance date 27Dec2017.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 December 2017
Resolved 13 December 2017
Resolution: Extension cords were removed and replaced with proper wire runs as well as multiple outlets for use in temporary applications.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 November 2017 Resolved
4. Queen Room Galley, there is an extension cord being used as permanent wire. Install proper outlet on the BLKHD where needed for the portable oven and remove the extension cord. Compliance date 27Dec2017.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 December 2017
Resolved 13 December 2017
Resolution: Extension cord removed and proper wiring provided.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 6 January 2016 Resolved
Replace wiring cable to govenor on #1, #2 and #3 generator.
Condition: Improper/Lack of Maintenance
Due 6 February 2016
Resolved 27 January 2016
Resolution: All wiring cables has been replaced.

Ownership record