MAURY USCG vessel records Sign in
← All vessels

EAGLE I

EAGLE I is a 1966 passenger vessel (inspected). The Coast Guard has recorded 19 inspections since 1985, most recently in March 2023, along with 36 deficiencies.

Records from 1985 to 2023. Most recent: inspection, 1 March 2023.

Built
1966
Last inspected
1 March 2023
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7309924 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDE3853
Flag
UNITED STATES
367345140 (licence lapsed)
Maury page id
psix-55304

Inspections, by type

…with no type recorded1
Years with a record 14 calendar years (1985–2023)
The 19 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)95.3 ft × 20.0 ft × 9.9 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)95.3 ft × 20.0 ft × 9.9 ft
ITC tonnagegross 162 / net 59
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1966
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portREEDVILLE, VA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it162 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
59 - Convention (Subpart B), Net Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDE3853MMSI 367345140 · expired · compulsorily equipped · granted 26 March 2008, cancelled 26 May 2018
WCY2408MMSI not assigned · expired · voluntarily equipped · granted 20 March 1998, cancelled 24 May 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 19

1 March 2023 Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7640364
21 December 2020 Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7114905
21 March 2010 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3965277
24 March 2009 Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3439418
14 August 2008 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3264573
24 July 2006 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2725194
29 August 2005 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2478541
13 July 2005 Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2406354
25 June 2004 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2063860
26 March 2004 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2032023
21 August 2002 Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1677081
1 May 2001 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1064041
18 April 2001 Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1435174
18 April 2001 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1469983
27 May 1999 COI Inspection · Inclining Experiment · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1410205
12 November 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 79489
10 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015210
13 September 1985 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016076
13 September 1985 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025620

Deficiency record · 36

Operations/Management › Passenger Operations › Safety Orientation
Issued 22 March 2010 Resolved
Vessel is prohibited from carrying passengers until completion of Coast Guard annual inspection to the satisfaction of a marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2020
Resolution: Deficiency cleared for administrative purposes only.
Electrical › Lighting (service) › Conductor
Issued 24 March 2009 Resolved
Remove lighting extension cords, and dead-end wiring IWO old fish hold.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 21 December 2020
Resolution: Deficiency cleared for administrative purposes only
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 13 July 2005 Resolved
Provide Passenger count.
Condition: Unknown
Due 12 August 2005
Resolved 29 August 2005
Resolution: Passenger count is located in a mailbox at vessel mooring (behind Eagle Cruise Sign).
Lifesaving › Lifebuoys › Approval
Issued 13 July 2005 Resolved
Provide type II retro on back side of aft life buoy.
Condition: Unknown
Due 12 August 2005
Resolved 29 August 2005
Resolution: Provided retro tape to life buoy.
Construction/Loadline › Hull › Weld
Issued 13 July 2005 Resolved
Repair marked 11 broken welds on inside stern bulkhead.
Condition: Damaged By Earlier Event
Due 12 August 2005
Resolved 29 August 2005
Resolution: Repaired broken welds.
Stability › Watertight Integrity › General
Issued 8 April 2004 Resolved
Remove temporary plates (2) covering pre-existing MDE exhaust bulkhead penetrations in the lazarette with 18" X 18" inserts. LEGACY COMPONENT DESC: Lazarette
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 25 June 2004
Accommodation/Occupational Safety
Issued 1 May 2001 Resolved
PROVIDE FLANGED "SEALED" INTAKE ON TOP OF VESSELS SEWAGE TANK IAW 46CFR184.704 AND IN COMPLIANCE WITH 33CFR PART 157.
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Fire Fighting
Issued 1 May 2001 Resolved
PROVIDE GAUGE AT PUMP OUTLET ON FIRE PUMP IAW 46CFR181.300.
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Navigation
Issued 1 May 2001 Resolved
PROVIDE PROOF OF PROPER OPERATION OF VESSELS RADAR.
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Lifesaving
Issued 1 May 2001 Resolved
CLOSE UP RAIL COURSES TO < 4 INCHES IN ACCORDANCE WITH 46 CFR 177.900
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Documentation
Issued 1 May 2001 Resolved
PROVIDE PROOF OF ENROLLEMENT IN CHEMICAL TESTING PROGRAM._x001C_
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Electrical
Issued 18 April 2001 Resolved
PROVIDE DETAILS AND PLAN REVIEW REQUEST FOR NEW GENERATOR INSTALLATION.
Condition: Unknown
Due 30 July 2002
Resolved 30 July 2002
Resolution: Re-issued requirement under PHIMS.
Construction/Loadline
Issued 18 April 2001 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPAIR ALL INOPERABLE HIGH LEVEL BILGE ALARMS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Construction/Loadline
Issued 18 April 2001 Resolved
INSTALL A LATCH CABABLE OF BEING OPENED FROM BOTH SIDES ON THE DECK HTCHES LEADING TO THE GALLEY AND MAIN MACHINERY SPACE. PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Fire Fighting
Issued 18 April 2001 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, CONNECT AUXILLIARY POWER SUPPLY TO FIRE DETECTION PANEL.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 18 April 2001 Resolved
PROVIDE PROOF OF FIXED FF SERVICING INCOUDING TESTING OF SENSORS AND PRESSURE SWITCHES. PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Accommodation/Occupational Safety
Issued 18 April 2001 Resolved
PROVIDE LOCKING DEVICES FOR PASSENGER GANGWAY GATES RAIL PINS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Accommodation/Occupational Safety
Issued 18 April 2001 Resolved
PROVIDE/INSTALL ADDITIONAL BOLTS WITH LOCKING NUTS AROUND PILOT HOUSE WINDOWS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Documentation
Issued 18 April 2001 Resolved
COMPLETE REINSPECTION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Accommodation/Occupational Safety
Issued 18 April 2001 Resolved
PROVIDE DETAILS AND PLAN REVIEW REQUEST FOR NEW AIR CONDITIONING UNITS INSTALLED IN DINING ROOM.
Condition: Unknown
Due 30 July 2002
Resolved 30 July 2002
Resolution: Reissued requirement under PHIMS.
Fire Fighting
Issued 18 April 2001 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE PROOF OF SERVICING FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Documentation
Issued 18 April 2001 Resolved
PROVIDE PROOF OF ENROLLMENT IN AN APPROVED DRUG TESTING PROGRAM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 18 April 2001 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE RETRO-REFLECTIVE TAPE ON RING BUOYS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Documentation
Issued 18 April 2001 Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Lifesaving
Issued 18 April 2001 Resolved
AFFIX PFD DONNING INSTRUCTIONS AT STOWAGE AREAS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Lifesaving
Issued 18 April 2001 Resolved
MARK THREE ADULT AND ONE CHILD PFD'S WITH VESSELS NAME.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Documentation
Issued 18 April 2001 Resolved
POST CERTIFICATE OF INSPECTION AND STABILITY LETTER IN A CONSPICUOUS PLACE VISIBLE TO PASSENGERS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 18 April 2001 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROPERLY LABEL ENTRANCE TO UPPER DECK WITH TOTAL PERSONS ALLOWED PER THE VESSELS STABILITY LETTER.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 18 April 2001 Resolved
PROVIDE CLOSEABLE OPENING, OR PERMANENTLY REPAIR HOLE IN PORT PILOTHOUSE WATERTIGHT DOOR.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 18 April 2001 Resolved
PROVIDE THE CORRECT AMOUNT OF LIFE JACKETS IAW VESSELS CERTIFICATE OF INSPECTION. TOTAL PERSONS ALLOWED IS REDUCED TO TOTAL LIFE JACKETS ON BOARD VESSEL UNTIL PROPER AMOUNT OF PFD'S ARE ONBOARD.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 18 April 2001 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, POST LIFE JACKET DONNING INSTRUCTIONPLACARDS IN ALL LIFE JACKET STOWAGE LOCATIONS.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 18 April 2001 Resolved
PROVE PROPER OPERATION ALL WTD'S PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Construction/Loadline
Issued 18 April 2001 Resolved
PROVIDE INDICATOR LIGHT FOR AFT WATERTIGHT DOOR.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Accommodation/Occupational Safety
Issued 18 April 2001 Resolved
PROPERLY SEAL AND COMPLETE REPLACEMENT OF PILOT HOUSE WINDOWS.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 18 April 2001 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE COMPLETE, SIMPLE INSTRUCTIONS FOR OPERATING FIXED CO2 FIRE-FIGHTING SYSTEM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 18 April 2001 Resolved
REPAIR AND MAINTAIN ALL WATERTIGHT DOORS.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.