Records from 1985 to 2023. Most recent: inspection, 1 March 2023.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
1 March 2023
Plan Review "T" Boat
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7640364
21 December 2020
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7114905
21 March 2010
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3965277
24 March 2009
Drydock Exam · Internal Structural Exam
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 3439418
14 August 2008
COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3264573
24 July 2006
Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2725194
29 August 2005
Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2478541
13 July 2005
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2406354
25 June 2004
COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2063860
26 March 2004
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2032023
21 August 2002
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1677081
1 May 2001
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1064041
18 April 2001
Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1435174
18 April 2001
Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1469983
27 May 1999
COI Inspection · Inclining Experiment · Hull Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1410205
12 November 1993
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 79489
10 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015210
13 September 1985
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016076
13 September 1985
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025620
Operations/Management › Passenger Operations › Safety Orientation
Issued 22 March 2010
Resolved
Vessel is prohibited from carrying passengers until completion of Coast Guard annual inspection to the satisfaction of a marine inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2020
Resolution: Deficiency cleared for administrative purposes only.
Electrical › Lighting (service) › Conductor
Issued 24 March 2009
Resolved
Remove lighting extension cords, and dead-end wiring IWO old fish hold.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 21 December 2020
Resolution: Deficiency cleared for administrative purposes only
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 13 July 2005
Resolved
Provide Passenger count.
Condition: Unknown
Due 12 August 2005
Resolved 29 August 2005
Resolution: Passenger count is located in a mailbox at vessel mooring (behind Eagle Cruise Sign).
Lifesaving › Lifebuoys › Approval
Issued 13 July 2005
Resolved
Provide type II retro on back side of aft life buoy.
Condition: Unknown
Due 12 August 2005
Resolved 29 August 2005
Resolution: Provided retro tape to life buoy.
Construction/Loadline › Hull › Weld
Issued 13 July 2005
Resolved
Repair marked 11 broken welds on inside stern bulkhead.
Condition: Damaged By Earlier Event
Due 12 August 2005
Resolved 29 August 2005
Resolution: Repaired broken welds.
Stability › Watertight Integrity › General
Issued 8 April 2004
Resolved
Remove temporary plates (2) covering pre-existing MDE exhaust bulkhead penetrations in the lazarette with 18" X 18" inserts. LEGACY COMPONENT DESC: Lazarette
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 8 May 2004
Resolved 25 June 2004
Accommodation/Occupational Safety
Issued 1 May 2001
Resolved
PROVIDE FLANGED "SEALED" INTAKE ON TOP OF VESSELS SEWAGE TANK IAW 46CFR184.704 AND IN COMPLIANCE WITH 33CFR PART 157.
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Fire Fighting
Issued 1 May 2001
Resolved
PROVIDE GAUGE AT PUMP OUTLET ON FIRE PUMP IAW 46CFR181.300.
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Navigation
Issued 1 May 2001
Resolved
PROVIDE PROOF OF PROPER OPERATION OF VESSELS RADAR.
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Lifesaving
Issued 1 May 2001
Resolved
CLOSE UP RAIL COURSES TO < 4 INCHES IN ACCORDANCE WITH 46 CFR 177.900
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Documentation
Issued 1 May 2001
Resolved
PROVIDE PROOF OF ENROLLEMENT IN CHEMICAL TESTING PROGRAM._x001C_
Condition: Unknown
Due 14 May 2001
Resolved 15 May 2001
Electrical
Issued 18 April 2001
Resolved
PROVIDE DETAILS AND PLAN REVIEW REQUEST FOR NEW GENERATOR INSTALLATION.
Condition: Unknown
Due 30 July 2002
Resolved 30 July 2002
Resolution: Re-issued requirement under PHIMS.
Construction/Loadline
Issued 18 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPAIR ALL INOPERABLE HIGH LEVEL BILGE ALARMS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Construction/Loadline
Issued 18 April 2001
Resolved
INSTALL A LATCH CABABLE OF BEING OPENED FROM BOTH SIDES ON THE DECK HTCHES LEADING TO THE GALLEY AND MAIN MACHINERY SPACE. PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Fire Fighting
Issued 18 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, CONNECT AUXILLIARY POWER SUPPLY TO FIRE DETECTION PANEL.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 18 April 2001
Resolved
PROVIDE PROOF OF FIXED FF SERVICING INCOUDING TESTING OF SENSORS AND PRESSURE SWITCHES. PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Accommodation/Occupational Safety
Issued 18 April 2001
Resolved
PROVIDE LOCKING DEVICES FOR PASSENGER GANGWAY GATES RAIL PINS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Accommodation/Occupational Safety
Issued 18 April 2001
Resolved
PROVIDE/INSTALL ADDITIONAL BOLTS WITH LOCKING NUTS AROUND PILOT HOUSE WINDOWS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Documentation
Issued 18 April 2001
Resolved
COMPLETE REINSPECTION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Accommodation/Occupational Safety
Issued 18 April 2001
Resolved
PROVIDE DETAILS AND PLAN REVIEW REQUEST FOR NEW AIR CONDITIONING UNITS INSTALLED IN DINING ROOM.
Condition: Unknown
Due 30 July 2002
Resolved 30 July 2002
Resolution: Reissued requirement under PHIMS.
Fire Fighting
Issued 18 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE PROOF OF SERVICING FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Documentation
Issued 18 April 2001
Resolved
PROVIDE PROOF OF ENROLLMENT IN AN APPROVED DRUG TESTING PROGRAM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 18 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE RETRO-REFLECTIVE TAPE ON RING BUOYS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Documentation
Issued 18 April 2001
Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Lifesaving
Issued 18 April 2001
Resolved
AFFIX PFD DONNING INSTRUCTIONS AT STOWAGE AREAS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Lifesaving
Issued 18 April 2001
Resolved
MARK THREE ADULT AND ONE CHILD PFD'S WITH VESSELS NAME.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Documentation
Issued 18 April 2001
Resolved
POST CERTIFICATE OF INSPECTION AND STABILITY LETTER IN A CONSPICUOUS PLACE VISIBLE TO PASSENGERS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 18 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROPERLY LABEL ENTRANCE TO UPPER DECK WITH TOTAL PERSONS ALLOWED PER THE VESSELS STABILITY LETTER.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 18 April 2001
Resolved
PROVIDE CLOSEABLE OPENING, OR PERMANENTLY REPAIR HOLE IN PORT PILOTHOUSE WATERTIGHT DOOR.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Lifesaving
Issued 18 April 2001
Resolved
PROVIDE THE CORRECT AMOUNT OF LIFE JACKETS IAW VESSELS CERTIFICATE OF INSPECTION. TOTAL PERSONS ALLOWED IS REDUCED TO TOTAL LIFE JACKETS ON BOARD VESSEL UNTIL PROPER AMOUNT OF PFD'S ARE ONBOARD.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Lifesaving
Issued 18 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, POST LIFE JACKET DONNING INSTRUCTIONPLACARDS IN ALL LIFE JACKET STOWAGE LOCATIONS.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 18 April 2001
Resolved
PROVE PROPER OPERATION ALL WTD'S PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 April 2001
Resolved 13 June 2001
Construction/Loadline
Issued 18 April 2001
Resolved
PROVIDE INDICATOR LIGHT FOR AFT WATERTIGHT DOOR.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Accommodation/Occupational Safety
Issued 18 April 2001
Resolved
PROPERLY SEAL AND COMPLETE REPLACEMENT OF PILOT HOUSE WINDOWS.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Fire Fighting
Issued 18 April 2001
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PROVIDE COMPLETE, SIMPLE INSTRUCTIONS FOR OPERATING FIXED CO2 FIRE-FIGHTING SYSTEM.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 18 April 2001
Resolved
REPAIR AND MAINTAIN ALL WATERTIGHT DOORS.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001