TIKI TOO

TIKI TOO is a 1980 passenger vessel (inspected). The Coast Guard has recorded 60 inspections since 1985, most recently in February 2026, along with 61 deficiencies, 2 operational controls and 1 casualty investigation in 2003.

Records from 1985 to 2026. Most recent: inspection, 5 February 2026.

Built
1980
Last inspected
5 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDJ8975
Flag
UNITED STATES
368021630
Maury page id
psix-55306

Inspections, by type

…with no type recorded5
Years with a record 33 calendar years (1985–2026)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)55.8 ft × 14.0 ft × 4.0 ft
Registered tonnagegross 39 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLIMITED PRODUCTS INC · GOODLETSVILLE, TN, UNITED STATES · built 1980
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMARINA DEL REY, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 August 2026 · expires 30 September 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it39 - Simplified, Gross Ton
31 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDJ8975MMSI 368021630 · active · compulsorily equipped · granted 1 February 2018, expires 1 February 2028
WDH8891MMSI 367662550 · expired · compulsorily equipped · granted 20 March 2015, cancelled 24 May 2025
WCZ5948MMSI 367426610 · expired · voluntarily equipped · granted 29 September 2009, cancelled 15 February 2020
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 60

5 February 2026 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8282735
11 February 2025 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8048663
19 November 2024 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8015564
5 February 2024 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7836771
14 November 2022 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7573121
31 October 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7573123
17 February 2022 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7377136
19 January 2022 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7382223
11 March 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7154650
17 November 2020 Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7096923
18 February 2020 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6908212
26 February 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6632696
13 November 2018 Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6577375
8 January 2018 Administrative Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333993
6 December 2017 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6320578
24 November 2017 COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6302008
21 February 2017 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6087554
1 November 2016 Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6031331
16 February 2016 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5800784
28 October 2014 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5007234
8 February 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4240725
25 February 2011 Annual Inspection · DAPI Audit
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3951937
12 November 2010 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3879098
21 January 2010 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3669445
13 March 2009 Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3431892
8 December 2008 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3365064
17 November 2008 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3340873
26 November 2007 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3102371
28 November 2005 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2545577
29 November 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2248328
15 November 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2238673
1 December 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1957092
4 July 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1839025
2 December 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1713049
7 January 2002 Hull Examination · Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1477672
30 December 1999 Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 812644
17 December 1999 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1388961
23 October 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 778973
20 April 1995 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 857254
12 July 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 866742
2 June 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 860840
10 September 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1379851
30 April 1993 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1148466
2 July 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 951777
16 April 1992 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 943082
11 April 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227308
3 August 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 913877
24 April 1990 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1220766
6 March 1990 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 926382
21 March 1989 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1274456
18 May 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1044695
25 March 1988 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1300455
25 February 1988 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1024496
21 August 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1016273
2 January 1987 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1002300
3 October 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1300802
18 September 1985 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 990445
1 March 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1286284
21 February 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 978253
16 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 977692

Deficiency record · 61

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 5 February 2026 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Marine Inspector observed that the panel warning indicator at the operating station did not indicate the status of the system.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2026
Resolved 19 February 2026
Resolution: New dash panel installed. Ops check sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 5 February 2026 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Marine Inspector observed that when the automatic bilge pump operated, there was no installed visual indicator at the operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2026
Resolved 19 February 2026
Resolution: Indicator lights installed. Ops check good.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 February 2024 Resolved
Endorsements on Certificates of Documentation are valid for 1 year, except for Recreational Endorsements on Certificates of Documentation, which are valid for 1, 2, 3, 4, or 5 years. However, a Certificate of Documentation with a Recreational Endorsement and a Commercial Endorsement will only be valid for 1 year. Prior to the expiration of an endorsement, the owner of a vessel, which is not exempt from the requirement for documentation under paragraph (c) of § 67.9, must apply for renewal of the endorsement(s) by complying with paragraph (b) of this section. Vessels COD is expired.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 February 2024
Resolved 12 February 2024
Resolution: Operator made payment for COD.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 17 February 2022 Resolved
Provisions shall be made by means of plugs, covers, etc. to prevent the admission of air into the space protected. No closures provided to prevent the admission of air into the space. 46 CFR 181.20-35
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2022
Resolved 10 March 2022
Resolution: Inspector witnessed and approved installed closure device for engine room ventilation.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 17 February 2022 Resolved
A suitable marine type strainer shall be fitted with flame screens. STBD engine fuel filter missing flame screen. 46 CFR 182.20-40 "old-t"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2022
Resolved 10 March 2022
Resolution: Inspector approved installment of flame screen on STBD engine fuel filter.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 February 2022 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons and the vessel from electrical hazards, including fire caused by or originating in electrical shock. Power strip identified by aft refrigerator not secured.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 March 2022
Resolved 10 March 2022
Resolution: Inspected and approved installment of power cord near refrigerator.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2020 Resolved
Machinery space boundaries that separate machinery from accommodation spaces, service spaces, and control spaces must be lined with noncombustible panels or insulation. The vessel was missing numerous panels on the overhead and the aft bulkhead.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2020
Resolved 11 December 2020
Resolution: Vessel has proper insulation installed in engine compartment overhead and aft bulkhead.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2019 Resolved
Annual Inspection. Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel is currently overdue for its annual inspection. Vessel must complete a satisfactory annual inspection prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2019
Resolution: Completed Annual Exam
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 24 November 2017 Resolved
Mark the vessel hull transom with Name and Hailing Port in accordance with 46 CFR 67.123.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 December 2017
Resolved 6 December 2017
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 24 November 2017 Resolved
Replace retroreflective material on 2 adult lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 November 2017
Resolved 6 December 2017
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 21 February 2017 Resolved
Provide proof of operation the generator engine shutdown for the engine room fixed fire suppression system
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 February 2017
Resolved 10 March 2017
Engineering › Reduction Gearing/Clutches › Gear
Issued 21 February 2017 Resolved
Provide proof of operation of the port propulsion engine and reduction gear in all modes. ahead and astern
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 February 2017 Resolved
Make the vessel available to perform man overboard and fire drill.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 March 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 2 November 2016 Resolved
Vessel hull examination is past due.
Condition: Improper/Lack of Maintenance
Due 15 November 2016
Resolved 15 November 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 1 November 2016 Resolved
Ensure railing on bow withstands 200lb point load of force, for port/stbd bow embarkation zones.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 15 November 2016
Documentation › Logs/Records › Drug Test Records
Issued 16 February 2012 Resolved
Submit MIS report for 2011.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 March 2012
Resolved 4 April 2012
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 February 2011 Resolved
Labeled stowage to read 23 Adult Lifejackets
Action required: 705 - Other - as specified
Due 10 March 2011
Resolved 16 March 2011
Resolution: Compartment stenciled to read 23 Adult Lifejackets
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 25 February 2011 Resolved
Display EAP Hotline for employees
Action required: 705 - Other - as specified
Due 10 March 2011
Resolved 16 March 2011
Resolution: EAP Hotline posted for emplyeees
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 February 2011 Resolved
Electrical wire is too close to engine fan belt.
Action required: 705 - Other - as specified
Due 10 March 2011
Resolved 16 March 2011
Resolution: Rerouted eletrical wire and incased in in a plastic wrap. Wire is no longer a potential hazard.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 25 February 2011 Resolved
Log every 3 months emergency drill(s) conducted and attandee names.
Action required: 705 - Other - as specified
Due 10 March 2011
Resolved 16 March 2011
Resolution: Witness log and drills conducted.
Construction/Loadline › Hull › Transverse Frame
Issued 12 November 2010 Resolved
-
Action required: 705 - Other - as specified
Due 12 November 2010
Resolved 19 November 2010
Resolution: Marked area was anded down and gel coat was restored, Csee corresponding activity.
Fire Fighting › Fire Bucket › Capacity
Issued 17 November 2008 Resolved
Provide 01 2.5 Gallon Fire Bucket
Action required: 705 - Other - as specified
Due 8 January 2009
Resolved 8 December 2008
Resolution: Supplied a Fire Bucket.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 November 2008 Resolved
Provide guards over all exposed rotating machinery.
Action required: 705 - Other - as specified
Due 8 January 2009
Resolved 13 March 2009
Resolution: Guards provided over exposed rotating machinery.
Fire Fighting › Fire Bucket › Availability
Issued 28 November 2005 Resolved
Vessel currently carries 02 fire buckets; require a total of 03 IAW 46CFR181.610.
Due 28 November 2005
Resolved 28 November 2005
Resolution: Bucket provided at time of inspection.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 28 November 2005 Resolved
Ring buoy light line attachment in excess of 06 feet. Line must not exceed 06 feet and be at least 03 feet IAW 46CFR180.70(c)
Condition: Improper Installation
Due 28 November 2005
Resolved 28 November 2005
Resolution: Line shortened to proper length on the spot.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 1 December 2003 Resolved
Found vent openings in engine space lead to deck, which would lead to ineffectiveness of fixed Halon system. Informed O/O to provide vent closures on vents.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2003
Resolution: Vent covers provided
Engineering › Bilge Water Management System
Issued 1 December 2003 Resolved
Fix/replace high level bilge alarm in engine room space IAW 46 CFR 182.530.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 December 2003
Resolution: O/O fixed discrepancy on the spot by providing a new battery to the generator and rewiring the alarm to the bridge console.
Engineering › Bilge Water Management System
Issued 1 December 2003 Resolved
Positive shut off valve missing. O/O instructed to install positive shut off valve for electric bilge pump on port side mid-section IAW 46 CFR 182.520 (e)(7). LEGACY COMPONENT DESC: Valve
Condition: Unknown
Due 15 December 2003
Resolved 3 December 2003
Electrical
Issued 1 December 2003 Resolved
Electrical wires found in flying bridge console were not capped. O/O instructed to cap dead-end wires as appropriate.
Condition: Unknown
Due 15 December 2003
Resolved 3 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 1 December 2003 Resolved
Upper deck rails were loose, due to continuous usage by passengers. O/O instructed to tighten top rail on upper deck starboard side to keep from loosening. LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Due 15 December 2003
Resolved 3 December 2003
Electrical › Electrical Distribution System (service)
Issued 2 December 2002 Resolved
Breaker missing from main AC distribution panel. LEGACY COMPONENT DESC: Distribution Panel Bus
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 2 December 2002
Resolution: Replaced.
Electrical › Electric Supply System (service) › Cable
Issued 2 December 2002 Resolved
Metal cable/wire supports missing from engineroom wire runs. Existing supports plastic.
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 December 2002
Resolved 2 December 2002
Resolution: Replaced.
Electrical › Electric Supply System (service)
Issued 7 January 2002 Resolved
Unused and dead wiring in engine room and throughout the vessel.
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Removed all unused and dead end wiring in engine room and throughout the vessel prior to completion of inspection.
Engineering › Bilge Water Management System › Valve
Issued 7 January 2002 Resolved
Noted vessel did not have a positive shut off valve at through hull fitting for electric submersible bilge pump in engine room on starboard side.
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Installed a positive shut off valve prior to completion of inspection.
Electrical › Electric Supply System (service) › Cable
Issued 7 January 2002 Resolved
Noted fuel tanks on port and starboard side were not properly grounded.
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Installed grounding system from fuel fill fitting to fuel tanks on port and starboard side prior to completion of inspection.
Stability › Watertight Integrity
Issued 7 January 2002 Resolved
Noted wasted through hull fittings on port and starboard side that were not being used.
Action required: 705 - Other - as specified
Resolved 7 January 2002
Resolution: Removed wasted through hull fittings. Installed and blanked off new through hull fittings on port and starboard side of vessel prior to the completion of the inspection.
Electrical
Issued 2 June 1994 Resolved
PRIOR TO OPERATING AT NIGHT TIME WITH PASSENGERS FOR HIRE ABOARD, PROVIDE ONE ADDITIONAL FLASHLIGHT.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Documentation
Issued 2 June 1994 Resolved
CONDUCT A RADOM DRUG TEST OF THE CREW.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Engineering
Issued 30 April 1993 Resolved
REMARK FUEL SHUT OFF VALVE.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Fire Fighting
Issued 30 April 1993 Resolved
PROVIDE ONE ADDITIONAL TYPE B-II PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Navigation
Issued 30 April 1993 Resolved
PROVIDE UPDATED CHARTS OF AREA OF OPERATION.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Lifesaving
Issued 30 April 1993 Resolved
PRIOR TO GETTING UNDERWAY, PROVIDE 6 DAY DISTRESS SIGNALS.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Construction/Loadline
Issued 30 April 1993 Resolved
REPLACE MISSING PIPE CAPS FOR FRESH WATER FILL AND SEWAGE DISCHARGE DECK PIPE CONNECTIONS.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Fire Fighting
Issued 16 April 1992 Resolved
PRIOR TO THE CARRIAGE OF PASSENGERS DEMONSTRATE PROPER OPERATION OF HAND FIRE PUMP.
Condition: Unknown
Due 22 April 1992
Resolved 22 April 1992
Documentation
Issued 16 April 1992 Resolved
POST A PLASTIC POLLUTION PLACARD.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Documentation
Issued 16 April 1992 Resolved
PROVIDE A COPY OF VESSELS' DRUG TESTING PROGRAM ABOARD THE VESSEL.
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Fire Fighting
Issued 11 April 1991 Resolved
RESERVICE FIRE (PORTABLE) EXTINGUISHERS MISSING SEALS (TWO). THIS ITEM TO BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Lifesaving
Issued 24 April 1990 Resolved
PROVIDE 3 ADULT LIFE PRESERVERS TO REPLACE 3 REJECTED WITH PUNCTURED FLOATATION BAGS.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Lifesaving
Issued 25 March 1988 Resolved
PROVIDE 1 ADDITIONAL CHILD AND 1 ADDITIONAL ADULT LIFE JACKET.
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Fire Fighting
Issued 25 March 1988 Resolved
INSTALL PLACARDS AT MAIN ENGINE SHUTDOWN STATIONS FOR HALON SYSTEM
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Electrical
Issued 25 March 1988 Resolved
INSTALL VENTS IN BATTERY BOX
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Documentation
Issued 25 March 1988 Resolved
POST STABILITY LETTER AND FCC LICENSE
Condition: Unknown
Due 25 March 1988
Resolved 25 March 1988
Navigation
Issued 18 September 1985 Resolved
PROCURE A NAVIGATION CHART OF AREA OF OPERATION.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Navigation
Issued 18 September 1985 Resolved
PROCURE RECENT RULES OF THE ROAD.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Unknown
Issued 18 September 1985 Resolved
PROCURE PROPER FUEL OIL HOSES TO MAIN ENGINES AND S/S GENERATORS.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Electrical
Issued 18 September 1985 Resolved
REPAIR LOOSE WIRES TO FORWARD HEAD.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Fire Fighting
Issued 18 September 1985 Resolved
SERVICE FIXED HALON SYSTEM.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Construction/Loadline
Issued 18 September 1985 Resolved
PROCURE CAP TO AFT STBD DECK FUEL OIL SHUT DOWN.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Construction/Loadline
Issued 18 September 1985 Resolved
DOUBLE HOSE CLAMP ALL THREW HULL DISCHARGE HOSES.
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Navigation
Issued 18 September 1985 Resolved
PROCURE ANCHOR LIGHT
Condition: Unknown
Due 18 September 1985
Resolved 18 September 1985
Engineering
Issued 21 February 1985 Resolved
PROVIDE AN INTERLOCK SWITCH TO PREVENT THE ENGINES AND GENERATOR FROM STARTING WITHOUT THE BLOWER STARTING FIRST AND COMPLETING ONE COMPLETE AIR CHANGE AS REQUIRED BY 46 CFR 182.15-45.
Condition: Unknown
Due 21 February 1985
Resolved 21 February 1985

Casualty record · 1

4 July 2003Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1839025
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

FANTASY I (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.