MAURY USCG vessel records Sign in
← All vessels

CURRENT REPRIEVE

CURRENT REPRIEVE is a 1977 passenger vessel (inspected). The Coast Guard has recorded 42 inspections since 1985, most recently in September 2006, along with 56 deficiencies — 1 with no resolution recorded —.

Records from 1985 to 2006. Most recent: inspection, 18 September 2006.

Built
1977
Last inspected
18 September 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WZG3358
Flag
UNITED STATES
—
Maury page id
psix-55313

Inspections, by type

…with no type recorded1
Years with a record 20 calendar years (1985–2006)
The 42 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it66 - Simplified, Net Ton
83 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WZG3358MMSI not assigned · expired · compulsorily equipped · granted 13 June 1997, cancelled 19 August 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 42

18 September 2006 Damage Survey
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 2747712
19 August 2003 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1866564
9 May 2003 Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1790032
18 September 2002 Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1676529
24 May 2002 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1620011
20 September 2001 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1074422
22 August 2001 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 212462
15 August 2001 Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435264
25 July 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1052319
7 July 2000 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1420355
14 April 2000 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 819638
30 September 1999 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1039109
29 July 1999 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1109116
29 June 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1378764
12 January 1999 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1129129
3 December 1998 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1427601
8 July 1998 Re-Inspection · Drydock Extension
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473452
30 June 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462582
30 July 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1087987
28 June 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443719
28 June 1995 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 881000
23 May 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 860061
13 December 1993 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1159789
11 August 1993 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1158039
10 June 1993 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1145361
21 August 1992 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 946718
14 November 1991 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 950383
11 September 1991 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1245856
22 August 1991 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1244426
19 September 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 925017
22 August 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 931685
15 November 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 922710
22 August 1989 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1032612
15 June 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1033158
30 September 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1352236
23 August 1988 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1349080
27 April 1988 Hull Examination · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1035597
2 September 1987 Drydock Extension · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1311150
5 September 1986 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1337539
27 May 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 999044
20 May 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 996150
6 September 1985 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 988273

Deficiency record · 56

Construction/Loadline › Hull › Hull Plating
Issued 18 September 2006 No resolution recorded
vessel hull damaged after being blown off of blocks while in the shipyard, major hull repairs required.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 September 2002 Resolved
Proof of Enrollment - Missing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Operations/Management › Drills/Instruction › Fire
Issued 18 September 2002 Resolved
Demonstrate satisfactory Man overboard and Fire drills in the presence of the attending Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 18 September 2002 Resolved
Provide Master licenses and restricted radio operator's licenses for Master of vessel prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Engineering › Bilge Water Management System › Pump
Issued 18 September 2002 Resolved
Demonstrate the proper operation of bilge pumps and high-level alarms for center and aft voids prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 18 September 2002 Resolved
Provide prove of documentation of vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 18 September 2002 Resolved
Label all PFD's with vessel's name
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 September 2002 Resolved
Repair or replace float light on life ring
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 September 2002 Resolved
Repair spiral stair case hatch.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Fire Fighting › Fire Pumps › Impeller
Issued 18 September 2002 Resolved
Prove proper operation of fire pump.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Fire Fighting › Ventilation Systems › Operating Controls
Issued 18 September 2002 Resolved
Prove proper operation of engine and ventilation shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Electrical › Electric Generation Source (service) › Generator
Issued 18 September 2002 Resolved
Prove proper operation of starboard generator.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 18 September 2002 Resolved
Repair or replace insulation on port aft side shell in engine room.
Due 18 October 2002
Resolved 9 May 2003
Navigation › Electronic Positioning › GPS/DGPS Receiver
Issued 18 September 2002 Resolved
Properly secure GPS and Radar
Due 18 October 2002
Resolved 9 May 2003
Operations/Management › Drills/Instruction › Activating General Alarm
Issued 18 September 2002 Resolved
Provide operators manual for vessel's operating station. (Switches on dash)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Construction/Loadline › Penetrations › Gasket
Issued 18 September 2002 Resolved
Make proper repairs to stop leak to the forepeake transducer.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2003
Electrical
Issued 15 August 2001 Resolved
PROVE PROPER OPERATION OF STARBOARD GENERATOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 September 2001
Resolved 23 August 2001
Lifesaving
Issued 15 August 2001 Resolved
RENEW LIFE RING LINE WITH 60 FEET 5/16" BOUYANT LINE.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Construction/Loadline
Issued 15 August 2001 Resolved
PROVE PROPER OPERATION OF BILGE PUMP AND ALARM IN FORWARD COMPARTMENT PRIORTO CARRYING PASSENGERS.
Condition: Unknown
Due 22 September 2001
Resolved 23 August 2001
Documentation
Issued 15 August 2001 Resolved
PROVIDE PROVE OF CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 22 September 2001
Resolved 23 August 2001
Engineering
Issued 15 August 2001 Resolved
RENEW ALL DRY ROTTED RAW WATER AND JACKET WATER HOSES ON MAIN ENGINE AND GENERATORS.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Fire Fighting
Issued 15 August 2001 Resolved
PROVIDE PROOF OF SERVICING PORTABLE FIRE EXTINGUISHER IN MID SHIP CLOSET.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Engineering
Issued 15 August 2001 Resolved
RENEW HYDRAULIC HOSES ON BOW THRUSTER.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Construction/Loadline
Issued 15 August 2001 Resolved
PROVE PROPER OPERATIONOF AUDIBLE HIGH BILGE ALARM IN ENGINE ROOM._x001C_ PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 September 2001
Resolved 23 August 2001
Lifesaving
Issued 15 August 2001 Resolved
UPDATE EXPIRED SUPPLIES IN FIRST AID KIT OR RENEW.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Engineering
Issued 7 July 2000 Resolved
MARK (PAINT) FUEL SHUT OFF VALVE HANDLES_x001C_ PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Deck/Cargo
Issued 7 July 2000 Resolved
DERATE BOW THRUSTER ENGINE TO MAX 1850 RPM._x001C_ PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Fire Fighting
Issued 7 July 2000 Resolved
ENSURE COMPLETE FIXED FIRE SYSTEM IS INSTALLED PRIOR TO 01JUL00.
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Fire Fighting
Issued 7 July 2000 Resolved
ENSURE SOME MEANS IS PROVIDED TO SECURE ENGINEROOM VENTS._x001C_ PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 11 July 2000
Resolved 11 July 2000
Lifesaving
Issued 7 July 2000 Resolved
REPLACE AND ENSURE UPPER DECK LIFE RING IS COAST GUARD_x001C_ APPROVED.
Condition: Unknown
Due 20 July 2000
Resolved 11 July 2000
Documentation
Issued 29 June 1999 Resolved
Conduct simplified stability test as required by 46 CFR 178.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Electrical
Issued 29 June 1999 Resolved
Renew light covers on second deck 12vdc lights.
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Construction/Loadline
Issued 29 June 1999 Resolved
Install high level bilge alarms per 46 CFR 182.530
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Fire Fighting
Issued 29 June 1999 Resolved
Install fixed firefighting system in bow thruster space and engineroom per 46 CFR 181.420
Condition: Unknown
Due 29 June 1999
Resolved 29 June 1999
Lifesaving
Issued 8 July 1998 Resolved
Ensure that all three (3) ring buoys, including water light and line are tothe satisfaction of the attending inspector.
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 8 July 1998 Resolved
Provide batteries for all "Emergency lighting" flashlights and ensure in working order
Condition: Unknown
Due 8 July 1998
Resolved 8 July 1998
Electrical
Issued 28 June 1996 Resolved
REMOVE DEAD-ENDED WIRING FROM BILGE PUMP SPACE (FWD).
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Fire Fighting
Issued 28 June 1996 Resolved
PROVE SERVICING OF ALL PORTABLE AND FIXED FIRE EXTINGUISHERS.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Electrical
Issued 28 June 1996 Resolved
PLACE BLANKS IN ELECTRICAL PANEL BOX FOR 3 TON AIR CONDITIONER.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Construction/Loadline
Issued 28 June 1996 Resolved
REPAIR AND PROVE PROPER OPERATION OF FWD BILGE PUMP.
Condition: Unknown
Due 28 June 1996
Resolved 28 June 1996
Fire Fighting
Issued 22 August 1991 Resolved
REPLACE EXISTING PLASTIC NOZZLES WITH APPROVED FIRE HOSE NOZZLES AT FIRE STATIONS.
Condition: Unknown
Due 22 August 1991
Resolved 22 August 1991
Accommodation/Occupational Safety
Issued 22 August 1990 Resolved
REPLACE BUG SCREEN ON POTABLE WATER TANK VENT.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Construction/Loadline
Issued 22 August 1990 Resolved
PROVIDE DOUBLE HOSE CLAMPS ON BOTH GENERATORS, AND SANITARY PUMP SUCTION.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Accommodation/Occupational Safety
Issued 22 August 1990 Resolved
REPLACE BROKEN WINDOW, MID-MAIN CABIN AT UPPER DECK.
Condition: Unknown
Due 22 August 1990
Resolved 22 August 1990
Electrical
Issued 22 August 1989 Resolved
PROVIDE APPROVED ELECTRICAL WIRING SPLICED BELOW INSTRUMENT PANEL.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Electrical
Issued 22 August 1989 Resolved
REMOVE DEAD END CABLE IN BOW VOID.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Electrical
Issued 22 August 1989 Resolved
PROVIDE BATTERY BOXES FOR EACH OF THE THREE MAIN ENGINE BATTERIES.
Condition: Unknown
Due 22 August 1989
Resolved 22 August 1989
Construction/Loadline
Issued 23 August 1988 Resolved
PROVIDE POSITIVE ACTION VALVE OR COCK AT EACH OVERBOARD DISCHARGE OR SUCTION THAT IS 6" OR LESS ABOVE THE DEEPEST SUBDIVISION LOADLINE. 46CFR171.119.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Documentation
Issued 23 August 1988 Resolved
POST STABILITY LETTER AT MAIN STEERING STATION. 46 CFR 185.12
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Construction/Loadline
Issued 23 August 1988 Resolved
REPLACE ALL NON-METALLIC THROUGH - HULL PENETRATIONS WITH METALLIC 46CFR182.40-1(A)(3).
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Engineering
Issued 23 August 1988 Resolved
PROVIDE TWO ENGINE COMPARTMENT VENTILATION INTAKE LOUVERS AT THE FORWARD END OF THE COMPARTMENT.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Engineering
Issued 23 August 1988 Resolved
INSTALL 30 X 30 FLAME SCREEN IN 3 FUEL TANK OVERFLOW VENTS.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Accommodation/Occupational Safety
Issued 23 August 1988 Resolved
PROVIDE INSECT SCREEN FOR POTABLE WATER TANK VENT.
Condition: Unknown
Due 23 August 1988
Resolved 23 August 1988
Lifesaving
Issued 6 September 1985 Resolved
STENCIL VESSELS NAME ON RING LIFE BUOY.
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Electrical
Issued 6 September 1985 Resolved
REMOVE ALL ELECTRICAL SPLITTER PLUGS (MULTIPLE OUTLETS PLUGGED INTO ONE ELECTRICAL OUTLET) AND EITHER HARD WIRE OR INSTALL ADEQUATE ELECTRICAL OUTLETS TO ALLOW ONE OUTLET PER PLUG IN.
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985
Fire Fighting
Issued 6 September 1985 Resolved
REMOVE THE FLAMMABLE FOAM INSULATION LINING THE ENGINE ROOM AND REPLACE IT WITH A SUITABLE FIRE RETARDENT MATERIAL FOR USE IN A MARINE ENGINE ROOM. THE MATERIAL TO BE USED IS TO BE APPROVED BY THE [name withheld] PRIOR TO INSTALLATION.
Condition: Unknown
Due 6 September 1985
Resolved 6 September 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.