MAURY USCG vessel records Sign in
← All vessels

EVER READY

EVER READY is a 1969 industrial vessel. The Coast Guard has recorded 54 inspections since 1984, most recently in April 2024, along with 63 deficiencies.

Records from 1984 to 2024. Most recent: inspection, 3 April 2024.

Built
1969
Last inspected
3 April 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBR4794
Flag
UNITED STATES
367711220 (licence lapsed)
Maury page id
psix-55314

Inspections, by type

…with no type recorded16
Years with a record 24 calendar years (1984–2024)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it48 - Regulatory (Subpart C or D), Gross Ton
33 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDI5701MMSI 367711220 · expired · compulsorily equipped · granted 20 January 2016, cancelled 28 March 2026
WCZ8108MMSI not assigned · expired · compulsorily equipped · granted 9 May 2000, cancelled 10 July 2010 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 54

3 April 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7890178
28 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2879371
21 February 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2878756
2 June 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2668475
7 April 2006 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2619704
15 September 2004 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2196661
30 July 2004 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2150371
30 July 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2150509
14 June 2004 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2098269
15 May 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1794076
15 July 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1646447
21 March 2002 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1645600
12 March 2001 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362526
30 March 2000 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1372979
23 April 1999 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386488
31 March 1998 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1386225
3 March 1998 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1409851
24 April 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380848
10 October 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 207878
10 October 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 752405
3 April 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1437068
26 February 1996 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1380416
31 May 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 204861
31 May 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 754044
3 April 1995 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1173946
11 February 1994 Hull Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1163121
11 February 1994 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1168660
11 March 1993 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 838537
20 May 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 643934
30 March 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 643935
24 January 1992 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 954486
3 January 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1263242
18 July 1991 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 938583
20 March 1991 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235646
14 December 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1244594
3 October 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1242397
31 August 1990 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 922074
29 May 1990 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 920039
14 June 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 892392
16 May 1989 Deficiency Check · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 894223
20 March 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1213608
4 March 1988 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335202
7 November 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329979
8 August 1987 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1337575
24 July 1987 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1022256
14 May 1986 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997951
10 March 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 991951
3 March 1986 Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304618
25 February 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1304616
11 June 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292282
15 April 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285828
14 March 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1289669
11 January 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 976493
10 December 1984 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 978407

Deficiency record · 63

Documentation › Certificates/Documents › Certificate of Inspection
Issued 7 April 2006 Resolved
Conduct Certificate of Inspection exam.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2006
Resolved 2 June 2006
Resolution: Owner voluntarily surrendered COI on this date.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 14 June 2004 Resolved
Repair exhaust leak stbd main engine
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 30 July 2004
Resolution: New bolts and gasket installed on outboard side of STBD Engine. Exhaust leak repaired.
Engineering › Sea-water System (primary cooling) › Piping
Issued 14 June 2004 Resolved
Re-install s/w cooling hose to stbd main engine exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 30 July 2004
Resolution: S/W cooling hose to STBD engine re-installed; new elbow pipe was installed to eliminate kinking of the cooling hose.
Engineering › Bilge Water Management System › Manifold
Issued 14 June 2004 Resolved
Make bilge alarm in fire pump space audible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 30 July 2004
Resolution: Fire pump space bilge alarm now audible.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 June 2004 Resolved
Provide valid registration for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 30 July 2004
Resolution: Valid EPIRB registration provided.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 14 June 2004 Resolved
Replace expired hydrostatic release for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 30 July 2004
Resolution: Hydrostatic release replaced, current expiration 6/2006
Engineering › Diesel Engine (propulsion-direct drive)
Issued 15 May 2003 Resolved
Replace f/o supply hose on STBD main engine and re-organize/re-route hose assembly to provide better security against chafing. LEGACY COMPONENT DESC: Fuel supply hose
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2003
Resolution: Hose replaced and re-routed.
Engineering › Sea-water System (primary cooling) › Piping
Issued 15 May 2003 Resolved
Replace r/w hose on PORT main engine above right valve cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 21 May 2003
Resolution: Hose replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 15 May 2003 Resolved
Properly mount B-1 fire extinguisher on the bridge. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 28 May 2003
Resolution: Properly mounted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 15 May 2003 Resolved
Properly mount one of the BII fire extinguishers near the outside of the lower entrance to engineroom. LEGACY COMPONENT DESC: Location
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 28 May 2003
Resolution: Properly mounted
Communications › Radio Communications › EPIRB
Issued 15 May 2003 Resolved
Provide EPIRB registration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 27 May 2003
Resolution: Faxed registration to me.
Lifesaving › Buoyant Apparatus
Issued 15 May 2003 Resolved
Maximum number of crew and passengers is limited to 12, based upon total allowance of the single liferaft. Provide proper liferaft allowance of 13 persons or submit letter to amend COI down to 12 total persons. LEGACY COMPONENT DESC: Allowance
Action required: 705 - Other - as specified
Due 19 June 2003
Resolved 27 May 2003
Resolution: Appropriate letter faxed requesting COI amendment to 12 total persons.
Engineering › Bilge Water Management System › Interface Detector
Issued 15 July 2002 Resolved
Bilge alarm float switch in engine room was not working.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 July 2002
Resolved 15 July 2002
Resolution: Replaced with a new float switch during the inspection. Corrected on the spot.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 15 July 2002 Resolved
Missing USCG Light List.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 July 2002
Resolved 15 July 2002
Resolution: Purchased a copy of the USCG Light List prior to the completion of the inspection.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 July 2002 Resolved
Replace plastic wire ties holding and fastening together wire bundles onto bulkheads and overheads in engineroom.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 August 2002
Resolved 8 August 2002
Resolution: Re-fastened wire bundles with metalic type.
Construction/Loadline › Hull › Hull Plating
Issued 13 July 2002 Resolved
Crop and renew as specified on attached worklist.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 July 2002
Resolved 13 July 2002
Engineering
Issued 12 March 2001 Resolved
Provide flame arresters (3).
Condition: Unknown
Due 4 November 2001
Resolved 4 November 2001
Navigation
Issued 12 March 2001 Resolved
Ensure steering gear is either double-nutted or cotter-pinned.
Condition: Unknown
Due 4 November 2001
Resolved 4 November 2001
Navigation
Issued 12 March 2001 Resolved
Tighten or replace portside rudder post packing.
Condition: Unknown
Due 4 November 2001
Resolved 4 November 2001
Accommodation/Occupational Safety
Issued 30 March 2000 Resolved
Replace port engine intake valve.
Condition: Unknown
Due 18 April 2000
Resolved 21 April 2000
Unknown
Issued 30 March 2000 Resolved
Submit repair proposal to Inspection Dept for insert on port quarter side shell.
Condition: Unknown
Due 18 April 2000
Resolved 21 April 2000
Lifesaving
Issued 30 March 2000 Resolved
Check for leaks around and beneath sink, shower & toilet.
Condition: Unknown
Due 18 April 2000
Resolved 21 April 2000
Construction/Loadline
Issued 30 March 2000 Resolved
Ensure hatch cover chains are actually attached to the vessel.
Condition: Unknown
Due 18 April 2000
Resolved 21 April 2000
Construction/Loadline
Issued 30 March 2000 Resolved
Replace port and starboard engine room hatch cover seals.
Condition: Unknown
Due 18 April 2000
Resolved 21 April 2000
Engineering
Issued 30 March 2000 Resolved
Replace both cutlass bearings on both shafts (4 total)
Condition: Unknown
Due 4 April 2000
Resolved 21 April 2000
Construction/Loadline
Issued 3 March 1998 Resolved
Crop and renew hull platin starboard side of engine room between frames 3 and 4, and longitudinals 2 and 3.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 3 March 1998 Resolved
Remove water and debris from foward three compartments and make spaces available for inspection.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Construction/Loadline
Issued 3 March 1998 Resolved
Remove four sea valves and make them available for inspection.
Condition: Unknown
Due 6 March 1998
Resolved 6 March 1998
Documentation
Issued 3 April 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 April 1996
Resolved 3 April 1996
Documentation
Issued 3 April 1995 Resolved
PROVIDE AND MAINTAIN ONBOARD RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 10 April 1995
Resolved 10 April 1995
Navigation
Issued 11 February 1994 Resolved
PROVIDE CORRECTED LIGHTLIST AND CHART OF LOCAL OPERATING AREA.
Condition: Unknown
Due 25 February 1995
Resolved 12 April 1994
Documentation
Issued 11 March 1993 Resolved
PROVIDE WASTE MANAGEMENT PLAN FOR THE VESSEL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Lifesaving
Issued 11 March 1993 Resolved
PROVIDE ONE ADDITIONAL COAST GUARD APPROVED TYPE 1 ADULT LIFEJACKET PRIOR TO CARRING MORE THAN 12 ADULTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 11 March 1993 Resolved
REPAIR WELD ON MAIN DECK STARBOARD SIDE AFT, OVERHEAD IN THE ENGINE ROOM.
Condition: Unknown
Due 11 March 1993
Resolved 11 March 1993
Construction/Loadline
Issued 31 August 1990 Resolved
STENCIL DRAFT MARKS ON BOW AND STERN IN ACCORDANCE WITH STABILITY LETTER.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Construction/Loadline
Issued 31 August 1990 Resolved
RENEW SEA VALVE FOR BILGE SUCTION.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Construction/Loadline
Issued 31 August 1990 Resolved
LABEL NAME OF VESSEL AND HOMEPORT ON STERN IAW 46 CFR 67.15-3(C).
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Electrical
Issued 29 May 1990 Resolved
PROPERLY SUPPORT ELECTRICAL WIRING IN ENGINE ROOM.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Engineering
Issued 29 May 1990 Resolved
DOUBLE CLAMP COOLING WATER HOSE ON AC GENERATOR.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Electrical
Issued 29 May 1990 Resolved
PROVIDE FREQUENCY METER AND AMMETER FOR AC GENERATOR AS PER 46 CFR 183.10-5(G) AND PROVE PROPER OPERATION OF OIL PRESSURE AND WATER TEMPERATURE GAUGE.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Lifesaving
Issued 29 May 1990 Resolved
PROVIDE 3 MORE ORANGE SMOKE VISUAL SIGNALS FOR A TOTAL OF 6, AS PER 46 CFR 180.35-5.
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Construction/Loadline
Issued 29 May 1990 Resolved
PROVIDE PROPER SIZE STRAINER ON FOREPEAK BILGE SUCTION AS PER 46 CFR 182.25-5(B).
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Construction/Loadline
Issued 29 May 1990 Resolved
PROPERLY MARK BOTH WATERTIGHT DOORS AS PER 46 CFR 185.30-25(A).
Condition: Unknown
Due 29 May 1990
Resolved 29 May 1990
Construction/Loadline
Issued 16 May 1989 Resolved
MAKE FORWARD BULKHEAD IN 3RD COMPARTMENT AFT WATERTIGHT.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Navigation
Issued 16 May 1989 Resolved
RENEW BEARINGS TO STEERING GEAR AND TIGHTEN CROSS-OVER BEAM ATTACHMENTS.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 16 May 1989 Resolved
PROVIDE CAPTURE CHAINS FOR MAIN DECK HATCHES IAW 46 CFR 171.124(B).
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 16 May 1989 Resolved
PROVIDE SEA STRAINERS FOR ALL THROUGH-HULL PENETRATIONS BELOW THE WATERLINETHAT ARE INTAKES.
Condition: Unknown
Due 16 May 1989
Resolved 16 May 1989
Construction/Loadline
Issued 20 March 1989 Resolved
REPAIR LEAK IN SEA STRAINER AND PIPING FROM THROUGH HULL FITTING AT SEA VALVE FOR STARBOARD MAIN ENGINE.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Engineering
Issued 20 March 1989 Resolved
PROPERLY REPAIR OR REPLACE MUFFLER ON PORT ENGINE INBOARD EXHAUST.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Engineering
Issued 20 March 1989 Resolved
REPLACE ENGINE COOLING WATER HOSE ON STARBOARD MAIN ENGINE.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Electrical
Issued 20 March 1989 Resolved
REMOVE OR PROPERLY DEAD END ELECTRICAL WIRING ON GENERATOR AND IN WAY OF MACERATOR.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Fire Fighting
Issued 20 March 1989 Resolved
SERVICE B-V AND ONE B-II EXTINGUISHER REQUIRED FOR CARRYING HAZARDOUS CARGOON BOARD VESSEL.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Engineering
Issued 20 March 1989 Resolved
REPAIR OR REPLACE PORT ENGINE INBOARD EXHAUST MANIFOLD.
Condition: Unknown
Due 20 March 1989
Resolved 20 March 1989
Documentation
Issued 24 July 1987 Resolved
PROVIDE CURRENT COPIES OF ALL NAVIGATION PUBLICATIONS.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Lifesaving
Issued 24 July 1987 Resolved
REPLACE ALL ROTTED LIFE LINES ON ALL THREE LIFE FLOATS PRIOR TO CARRIAGE OFPASSENGERS.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Engineering
Issued 24 July 1987 Resolved
DOUBLE HOSE CLAMP ALL FLEXIBLE HOSE CONNECTIONS TO THE RAW WATER COOLING FOR HEAT EXCHANGER AND EXHAUST LINES.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Engineering
Issued 24 July 1987 Resolved
PROVIDE VENT DUCT WHICH EXTENDS TO A POINT NEAR THE BOTTOM OF THE MACHINERYCOMPARTMENT. (46 CFR 182.20-45(C)).
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Lifesaving
Issued 24 July 1987 Resolved
REPAIR OR REPLACE ONE WATER LIGHT FOR THE RING BUOY PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Fire Fighting
Issued 24 July 1987 Resolved
REPAIR LEAK AT FIRE HOSE CONNECTION TO THE HYDRANT PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Electrical
Issued 24 July 1987 Resolved
BLANK OFF EMPTY AREAS OF DISTRIBUTION PANELS FOR FIRE PUMP AND BRIDGE MAIN ELECTRICAL PANELS.
Condition: Unknown
Due 24 July 1987
Resolved 24 July 1987
Construction/Loadline
Issued 14 March 1985 Resolved
PROVIDE WATERTIGHT CLOSURES FOR ALL 4 VENTS ON THE CARGO DECK.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Engineering
Issued 14 March 1985 Resolved
PROVIDE MAIN ENGINE EXHAUST BLANKETS AND GUARDS IN WAY OF THE SHAFTS.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985
Electrical
Issued 14 March 1985 Resolved
REPLACE ALL CAROL CABLE AND UNMARKED RED CABLE WITH APPROVED ELECTRICAL WIRING.
Condition: Unknown
Due 14 March 1985
Resolved 14 March 1985

Ownership record