Records from 1986 to 2009. Most recent: casualty investigation, 14 September 2009.
Inspection history · 34
12 June 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2959684
3 April 2007
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2794428
26 June 2006
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2692130
5 August 2005
Simplified Stability Test · COI Inspection · Plan Review "T" Boat · Hull Examination · Deficiency Check · Examination of Repairs
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2383062
11 January 2005
Plan Review "T" Boat
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2274492
17 November 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2243179
17 August 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2168888
28 May 2004
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2077939
27 April 2004
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2023571
29 July 2003
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1809021
7 August 2002
Damage Survey
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1663282
9 May 2002
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1612436
5 May 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1125432
3 October 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 786446
25 July 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1388135
2 July 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 165652
24 August 1995
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1374367
27 July 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1403979
13 June 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1431367
21 July 1993
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1156203
2 July 1993
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1377003
24 June 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 946762
28 May 1992
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 825955
29 April 1991
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1228015
5 June 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1214884
16 March 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1243439
27 February 1990
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 912813
7 September 1989
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1197023
15 June 1989
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1349101
3 August 1988
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1344202
23 February 1988
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1335968
27 November 1987
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1335585
22 May 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1314211
6 June 1986
Credit Drydock · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 992723
Electrical › Electric Generation Source (service) › Generator
Issued 5 August 2005
No resolution recorded
Do not operate aux gen set with passengers on board until installation is complete IAW submitted plans, and operational tests and inspections are witnessed by USCG attending marine inspector. (Extended at operators request)
Due 15 November 2006 — due date passed with no resolution recorded
Engineering › Steering Gear System › Ram Seal
Issued 5 August 2005
Resolved
Renew steering ram seals and test steering system, prior to the carriage of passengers.
Due 5 September 2005
Resolved 6 August 2005
Resolution: Notified by owner of correction will f/u on the 15th.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 5 August 2005
Resolved
Provide 04 more adult lifejackets with lights. Vessel is limited to no more than 25 total persons until vessel is outfitted as per COI.
Due 5 September 2005
Resolved 6 August 2005
Resolution: Notified by owner of correction ,will f/u on the 15th.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 17 August 2004
Resolved
RE-ISSUED REQUIRED TO PROVIDE OPERATIONAL TEST OF SINGLESIDE BAND RADIO. VESSEL IS RESTRICTED TO OPERATIONS NOT MORE THAN 20 MILES FROM SHORE. ORIGINAL REQUIREMENT WAS IMPROPERLY ENTERED.
Due 17 October 2004
Resolved 17 November 2004
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 28 May 2004
Resolved
Provide proof of operation for single side band, vessel is limited to operating no more than 100 miles from shore. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-4 MHz)
Due 28 June 2004
Resolved 17 August 2004
Resolution: CORRECTED VERBIAGE OF REQUIREMENT AND RE-ISSUED.
Documentation › Certificates/Documents › FCC SSL
Issued 28 May 2004
Resolved
Provide proof of FCC operators permit.
Due 17 October 2004
Resolved 5 August 2005
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 28 May 2004
Resolved
Provide proof of service for portable fire extinguishers, prior to the carriage of passengers for hire.
Due 28 June 2004
Resolved 17 August 2004
Resolution: RECEIVED FAX ED SERVICE REPORT FROM OPERATOR. HE HAD FAXED DURING ORIGINAL REQUIRED DATE BUT FAX WAS NOT RCD BY INSPECTOR.
Engineering › Shafting/Propeller Arrangements
Issued 27 April 2004
Resolved
Renew all cutlass bearings and prove shaft to be true prior to the carriage of passengers. Shaft appeares to be bent and bearings are badly worn after one year of service. LEGACY COMPONENT DESC: Strut Bearing
Condition: Unknown
Due 27 May 2004
Resolved 28 May 2004
Resolution: Repairs made and strut realigned.
Construction/Loadline › Hull
Issued 27 April 2004
Resolved
Prove soundness of hull IWO 1.5 inch lump, port side along lower stringer in steering compartment, prior to the carriage of passengers for hire. Make repair proposals and complete repairs to the satisfaction of the attending USCG marine inspector. LEGACY COMPONENT DESC: Side Shell
Condition: Unknown
Due 27 May 2004
Resolved 28 May 2004
Construction/Loadline › Hull
Issued 27 April 2004
Resolved
Renew rotten transverse frame in steering compartment port side of hatch. LEGACY COMPONENT DESC: Transverse Frame
Condition: Improper/Lack of Maintenance
Due 27 May 2004
Resolved 28 May 2004
Construction/Loadline › Hull
Issued 27 April 2004
Resolved
Prove soundness of keel trough area beneath the engine room, where water appears to be seeping out, prior to the carriage of passengers for hire. Make repair proposals to the attending USCG marine inspector. LEGACY COMPONENT DESC: Keel
Condition: Unknown
Due 27 May 2004
Resolved 28 May 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 27 April 2004
Resolved
Rework, perform maintenance on forward cabin emergency escape hatch, prove operation to the satisfaction of the attending marine inspector prior to the carriage of passengers for hire.
Due 27 May 2004
Resolved 28 May 2004
Operations/Management › Drug and Alcohol Testing
Issued 29 July 2003
Resolved
Provide proof of Drug and Alcohol Testing enrollment. LEGACY COMPONENT DESC: Proof of Enrollment
Due 20 August 2003
Resolved 21 August 2003
Stability › Watertight Integrity
Issued 29 July 2003
Resolved
Install hatch cover captive chains/cables to prevent loss of hatch covers. LEGACY COMPONENT DESC: Hatch Cover Captive Chains
Condition: Improper/Lack of Maintenance
Due 20 August 2003
Resolved 21 August 2003
Lifesaving › Inflatable Liferafts
Issued 29 July 2003
Resolved
Provide copy of life raft serving/initial packing report.
Condition: Unknown
Due 20 August 2003
Resolved 21 August 2003
Engineering › Steering Gear System
Issued 7 August 2002
Resolved
Provide service report for straightening of the rudder. LEGACY COMPONENT DESC: Rudder
Condition: Damaged By Earlier Event
Due 16 August 2002
Resolved 9 August 2002
Engineering › Steering Gear System › Rudder Bearing
Issued 7 August 2002
Resolved
Renew the skeg support to the lower rudder shoe.
Condition: Damaged By Earlier Event
Due 16 August 2002
Resolved 9 August 2002
Lifesaving › Lifejacket/PFD (General)
Issued 9 May 2002
Resolved
Provide live jacket donning placard for the horse shoe type jackets 46CFR185.516 LEGACY COMPONENT DESC: Donning Placard
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Navigation › Piloting/Steering
Issued 9 May 2002
Resolved
Prove proper operation of the compass light. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Personnel › Certificates/Documents/Licenses
Issued 9 May 2002
Resolved
Provide valid FCC Safety Certificate and Operator license. LEGACY COMPONENT DESC: FCC Safety certificate and operator license.
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Engineering › Steering Gear System
Issued 9 May 2002
Resolved
Prove proper operation of steering system. LEGACY COMPONENT DESC: Hydraulic Hose
Condition: Placed in Improper Service
Due 9 June 2002
Resolved 17 May 2002
Communications › Radio Communications
Issued 9 May 2002
Resolved
Prove proper operatio of single side band radio, after it is installed on the vessel. LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 9 May 2002
Resolved
Prove proper operation of fixed fire extinguishers audible alarm and engine shutdown. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Shut down and audible alarm
Condition: Improper Installation
Due 9 June 2002
Resolved 17 May 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 9 May 2002
Resolved
Provide remote fuel shut offs with proper markings. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Valve
Condition: Design Flaw
Due 9 June 2002
Resolved 17 May 2002
Engineering › Fuel Oil Service System
Issued 9 May 2002
Resolved
Provide flame shield and metal plugs for the fuel bowl. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Filter
Due 9 June 2002
Resolved 17 May 2002
Pollution Prevention/Response › Prevention Equipment
Issued 9 May 2002
Resolved
Provide placard for sewage system overboard valve. LEGACY COMPONENT DESC: Sewage placard
Condition: Improper Installation
Due 9 June 2002
Resolved 17 May 2002
Construction/Loadline › Structures
Issued 9 May 2002
Resolved
Mark forward hatch with keep clear emergency escape LEGACY COMPONENT DESC: Scuttle
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Electrical › Electric Supply System (service)
Issued 9 May 2002
Resolved
Provide covers for battery boxes. LEGACY COMPONENT DESC: Battery Installation
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Electrical › Electrical Distribution System (service)
Issued 9 May 2002
Resolved
Provide labels for circuit breakers showing what they service. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Construction/Loadline › Structures
Issued 9 May 2002
Resolved
Renew or repair the deck long beam located fwd of the collisions bulkhead. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Deck Long
Due 9 June 2002
Resolved 17 May 2002
Engineering › Sea-water System (primary cooling)
Issued 9 May 2002
Resolved
Provide double clamps for all through hole fittings andf on the muffler.
Condition: Improper Installation
Due 9 June 2002
Resolved 17 May 2002
Personnel › Training
Issued 9 May 2002
Resolved
Conduct operational test of all machinery and conduct man overboard and fire drill. Must be completed prior to carriage of passengers. LEGACY COMPONENT DESC: Man overboard and fire drill
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Construction/Loadline › Penetrations
Issued 9 May 2002
Resolved
Close up holes in the collision bulkhead. LEGACY COMPONENT DESC: Close holes in collision bulkhead
Condition: Unknown
Due 9 June 2002
Resolved 17 May 2002
Construction/Loadline › Structures
Issued 9 May 2002
Resolved
Replace cracked window in the pilot house. LEGACY COMPONENT DESC: Windows
Condition: Damaged By Earlier Event
Due 9 June 2002
Resolved 17 May 2002
Construction/Loadline
Issued 2 July 1993
Resolved
CONDUCT SAT TEST OF BILGE PUMPING SYSTEM.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Engineering
Issued 2 July 1993
Resolved
CONDUCT SAT TEST OF MAIN PROPULSION SYSTEM.
Condition: Unknown
Due 2 July 1993
Resolved 2 July 1993
Construction/Loadline
Issued 28 May 1992
Resolved
REPAIR LEAK/FRACTURE IN AFT ENGINEROOM BULKHEAD BELOW SHAFT LOG AND ABOVE KEEL.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Construction/Loadline
Issued 28 May 1992
Resolved
MAKE OPERABLE HIGH WATER ALARM IN LAZARETTE.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Construction/Loadline
Issued 28 May 1992
Resolved
PROVIDE SECURING LATCH FOR FISH HOLD HATCH.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Construction/Loadline
Issued 28 May 1992
Resolved
CAP OR PLUG OVERBOARD LINE PORTSIDE, AFT IN ENGINEROOM.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Lifesaving
Issued 28 May 1992
Resolved
RENEW LIFELINES ON LIFEFLOAT WITH FLOATING LINE OR PROVIDE FLOATS FOR CURRENT LINE.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Electrical
Issued 28 May 1992
Resolved
INSTALL GROUND WIRE BETWEEN FUEL FILL OPENING AND FUEL TANK.
Condition: Unknown
Due 28 May 1992
Resolved 28 May 1992
Accommodation/Occupational Safety
Issued 27 February 1990
Resolved
REFASTEN HANDRAIL IN AFT SECTION OF DECK.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Construction/Loadline
Issued 27 February 1990
Resolved
REPLACE SECTIONS OF ROTTED WOOD IN FUEL TANK SPACE.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Accommodation/Occupational Safety
Issued 27 February 1990
Resolved
REPLACE FISH TANK WASH DOWN SUCTION VALVE.
Condition: Unknown
Due 27 February 1990
Resolved 27 February 1990
Engineering
Issued 22 May 1987
Resolved
FUEL SHUT-OFF VALVES MUST BE MADE ACCESSABLE FROM THE MAIN DECK (ACCESS COVER FROZEN IN PLACE).
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Accommodation/Occupational Safety
Issued 22 May 1987
Resolved
FRESH WATER TANK SUCTION LINE MUST BE FIRMLY ATTACHED AT BOTTOM OF TANK.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Engineering
Issued 22 May 1987
Resolved
PROVIDE CHECK VALVE IN ELECTRIC BILGE PUMP DISCHARGE LINE (IN ACCORDANCE WITH 46 CFR 182.25-5(C)).
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Navigation
Issued 22 May 1987
Resolved
REPAIR OR RENEW WOODEN MOUNTING BRACKET FOR STEERING RAM.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Accommodation/Occupational Safety
Issued 22 May 1987
Resolved
TOILET MUST BE MADE OPERATIONAL (NO WATER COMES INTO TOILET).
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Electrical
Issued 22 May 1987
Resolved
REPAIR WIRING ON STARTER MOTOR FOR ENGINE.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Lifesaving
Issued 22 May 1987
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE 6 ORANGE AND 6 RED FLARES.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Lifesaving
Issued 22 May 1987
Resolved
VESSEL RESTRICTED TO CARRYING A MAXIMUM OF 18 TOTAL PERSONS UNTIL MORE ACCEPTABLE ADULT LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Navigation
Issued 22 May 1987
Resolved
EMERGENCY TILLER FOR STEERING MUST BE MADE EASILY ACCESSABLE.
Condition: Unknown
Due 22 May 1987
Resolved 22 May 1987
Fire Fighting
Issued 6 June 1986
Resolved
VESSEL IS REQUIRED TO HAVE ONE ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR THE GALLEY STOVE.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986