Records from 1986 to 2007. Most recent: inspection, 29 October 2007.
Inspection history · 59
29 October 2007
Type not recorded
No type recorded · Station Umpqua River · USCG Northwest District (CGD-NW) · Activity 3088718
19 October 2005
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2519454
1 October 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2215882
30 August 2004
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2181107
2 April 2004
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2035637
4 December 2003
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1961488
18 August 2003
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1877203
7 January 2003
Administrative Inspection
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1727557
26 August 2002
Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1679801
11 June 2001
Deficiency Check · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1389416
12 April 2001
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1387097
28 August 2000
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1369820
3 January 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 811869
30 August 1999
Re-Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1427744
5 July 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 147741
15 December 1998
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 809103
21 August 1998
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 804607
24 June 1998
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 795701
18 September 1997
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 775519
6 September 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 33182
4 September 1997
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1121046
2 July 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 782665
17 June 1996
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1442451
11 April 1996
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1446322
24 January 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1189320
31 August 1995
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 39893
27 July 1995
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1079259
28 June 1995
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1190510
27 June 1995
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1402059
19 July 1994
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1470896
16 December 1993
Deficiency Check · Plan Review "T" Boat
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1389733
26 October 1993
Hull Examination · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1467392
6 August 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 372
16 July 1993
Plan Review "T" Boat · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 848018
25 June 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 142843
8 June 1993
Drydock Extension
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 844784
8 June 1993
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1370640
24 February 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1147290
7 January 1993
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1135448
18 November 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1133259
3 September 1992
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 962065
29 June 1992
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 952450
3 April 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1320353
6 August 1991
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 934689
2 July 1991
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1246041
3 July 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1243482
18 June 1990
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 901598
17 October 1989
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1352939
12 October 1989
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1034092
27 September 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1306381
13 July 1989
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1042040
28 October 1988
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 891406
16 August 1988
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1344078
28 July 1988
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1035117
28 July 1988
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1265127
30 June 1987
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1310992
1 July 1986
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1005116
19 March 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1303783
20 February 1986
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 985501
Fire Fighting › Ventilation Systems › Operating Controls
Issued 30 August 2004
Resolved
Provide a means to secure engine room ventilation remotely to enable fixed gas firefighting system function as designed. 46 CFR 182.465(h). Current ventilation required to be secured until repairs have been made. Correct to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Due 30 September 2004
Resolved 1 October 2004
Resolution: Remote manual engine room ventilation shut down installed at the fixed fire fighting system operating station as required.
Engineering › Lubricating Oil Storage/Transfer System › Drain Tank
Issued 30 August 2004
No resolution recorded
Remove/replace current oil catchment totes for chain drive drag through lubrication system. Current system presents a potential fire hazard. Operator may use chain lubricant in place of used crank case oil or install enclosed non-combustible containers for catchment. Correct to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Due 31 December 2004 — due date passed with no resolution recorded
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 30 August 2004
Resolved
Service all portable fire extinguishers in excess of number required on COI. Operator may remove unserviced excess extinguishers as an alternative to servicing. 46 CFR 181.120. Correct to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Due 30 September 2004
Resolved 1 October 2004
Resolution: Extra extinguisher removed from service.
Engineering › Bilge Water Management System
Issued 18 August 2003
Resolved
Replace bilge hoses with approved type (SAE J1942). Bilge hose leading from pump to overboard discharge port are made of an unapproved material, to the satisfaction of the attending Coast Guard Marine Inspector. LEGACY COMPONENT DESC: Hose
Condition: Improper Installation
Due 18 September 2003
Resolved 23 September 2003
Resolution: Based on a faxed, signed (w/License number) statement from the vessel''s O/O, the subject hoses have been replaced.
Electrical › Electric Supply System (service)
Issued 18 August 2003
Resolved
Remove all household ROMEX wiring from vessel and replace with boat cable as necessary, to the satisfaction of the attending Coast Guard Marine Inspector.. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 1 April 2004
Resolved 2 April 2004
Resolution: ROMEX wiring removed and new boat cable installed.
Engineering › Sea-water System (primary cooling)
Issued 18 August 2003
Resolved
Double clamp raw water hoses. LEGACY COMPONENT DESC: Hoses
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 26 August 2003
Resolution: As per fax dated 26AUG03, secondary clamps have been installed on the associated vital systems in the engineering spaces as required. Fax signed by vessel''''s Master C.G. Eden Lic. #1020896.
Fire Fighting › Combustible Materials
Issued 18 August 2003
Resolved
Remove carpet and other combustible materials from engine space. LEGACY COMPONENT DESC: Carpets
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 26 August 2003
Resolution: As per fax dated 26AUG03, the combustible materials have been removed from the engineering spaces as required. Fax signed by vessel''''''''s Master C.G. Eden Lic. #1020896.
Navigation › Piloting/Steering
Issued 18 August 2003
Resolved
Provide US Coast Pilot, USCG Light List and 2003 Tidal Current Tables for area of operation. Extracts of these publications may be used. LEGACY COMPONENT DESC: Nautical publications
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 August 2003
Resolved 26 August 2003
Resolution: Vessel excluded from carrying certain navigational publications as per MSO Portland navpub policy for SPV''''''''s on restricted routes. Ref. MSO Portland CID Policy 03-01.
Lifesaving
Issued 11 June 2001
Resolved
1 Label PFD storage location
Condition: Unknown
Due 11 July 2001
Resolved 7 January 2003
Electrical
Issued 11 June 2001
Resolved
2 Remove extension cords and permanently wire fixtures
Condition: Unknown
Due 11 July 2001
Resolved 7 January 2003
Documentation
Issued 11 June 2001
Resolved
3 Provide drug testing documentation for all crew members.
Condition: Unknown
Due 11 July 2001
Resolved 7 January 2003
Fire Fighting
Issued 11 June 2001
Resolved
4 Provide annual servicing for fixed fire fighting bottle
Condition: Unknown
Due 11 July 2001
Resolved 7 January 2003
Construction/Loadline
Issued 12 April 2001
Resolved
Repair wasted stbd side aft quarter gussets
Condition: Unknown
Due 11 June 2001
Resolved 14 June 2001
Construction/Loadline
Issued 12 April 2001
Resolved
Provide check valve for engine room bilge pump._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 2001
Resolved 14 June 2001
Construction/Loadline
Issued 12 April 2001
Resolved
Seal pin hole on port side stern
Condition: Unknown
Due 11 June 2001
Resolved 14 June 2001
Construction/Loadline
Issued 12 April 2001
Resolved
Seal pitman arm penetrations on port side stern
Condition: Unknown
Due 11 June 2001
Resolved 14 June 2001
Electrical
Issued 28 August 2000
Resolved
Hard wire all permanent fixtures throughout engine room.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Lifesaving
Issued 28 August 2000
Resolved
Replace wasted lifering water light line.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Engineering
Issued 28 August 2000
Resolved
Replace all fuel lines with USCG approved A1/A2/B1 or B2 hose or pipe._x001C_
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Navigation
Issued 28 August 2000
Resolved
Provide chart for operational area.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Construction/Loadline
Issued 28 August 2000
Resolved
Provide audiable/visual alarm for automatic bilge pump activation._x001C_
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Navigation
Issued 28 August 2000
Resolved
Provide emergency broadcast placard.
Condition: Unknown
Due 30 November 2000
Resolved 30 November 2000
Lifesaving
Issued 30 August 1999
Resolved
LABEL UPPER DECK LIFE JACKET STORAGE LOCATION.
Condition: Unknown
Due 27 September 1999
Resolved 18 November 1999
Construction/Loadline
Issued 30 August 1999
Resolved
PROVIDE HIGH LEVEL BILGE ALARM.
Condition: Unknown
Due 27 September 1999
Resolved 18 November 1999
Fire Fighting
Issued 30 August 1999
Resolved
PROVIDE LOG FOR FIRE, MAN OVERBOARD AND LIFESAVING EQUIPMENT DRILLS/INSPECTIONS.
Condition: Unknown
Due 27 September 1999
Resolved 18 November 1999
Electrical
Issued 30 August 1999
Resolved
PROVIDE GUARD FOR EXPOSED BRIDGE LIGHT.
Condition: Unknown
Due 27 September 2000
Resolved 18 November 1999
Electrical
Issued 30 August 1999
Resolved
PROVIDE APPROVED STERN LIGHT.
Condition: Unknown
Due 27 September 1999
Resolved 18 November 1999
Fire Fighting
Issued 30 August 1999
Resolved
PROVIDE ENGINE ROOM BULKHEADS SMOKE TIGHT FOR FIXED FIREFIGHTING SYSTEM.
Condition: Unknown
Due 27 September 1999
Resolved 18 November 1999
Fire Fighting
Issued 24 June 1998
Resolved
PROVIDE A BII FIRE EXTINGUISHER FOR MACHINERY SPACE.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Lifesaving
Issued 24 June 1998
Resolved
INSTALL RETRO-REFLECTIVE TAPE ON VESSELS RING BUOY.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Engineering
Issued 24 June 1998
Resolved
DEMONSTRATE SECOND MEANS OF CONTROL FOR THE MAIN PROPULSION SYSTEM.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Electrical
Issued 24 June 1998
Resolved
INSTALL CAPTIVE TYPE CONNECTION ON WIRE ATTACHED TO BATTERY POST.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Lifesaving
Issued 24 June 1998
Resolved
REPAIR/REPLACE GRAB LINE AROUND RING BUOY.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Lifesaving
Issued 24 June 1998
Resolved
INSTALL 3-6 FOOT LINE ON RING BUOY LIGHT.
Condition: Unknown
Due 24 June 1998
Resolved 24 June 1998
Documentation
Issued 2 July 1997
Resolved
CONDUCT STABILITY TEST IAW 46CFR171. VESSEL IS RESTRICTED TO REQ'TS OF STABILITY TEST CONDUCTED 15 JUNE 1983 AND LETTER ISSUED 15 SEPTEMBER 1983. UNTIL NEW STABILITY TEST IS CONDUCTED, 13 PASSENGERS ARE ALLOWED ON 2ND DECK, NO PASSENGERS ARE ALLOWED ON UPPERMOST DECK OR TOP OF PILOT HOUSE.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Lifesaving
Issued 2 July 1997
Resolved
PROVIDE PFD DONNING PLACARDS FOR BOTH STYLE LIFEJACKETS ONBOARD THE VESSEL AND DISTRIBUTE THROUGHOUT ACCOMMODATIONS.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Accommodation/Occupational Safety
Issued 2 July 1997
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Condition: Unknown
Due 8 August 1997
Resolved 8 August 1997
Electrical
Issued 2 July 1997
Resolved
PROVIDE THE NAME PLATE DATA FOR THE INDEPENDENT GENERATOR AS REQUIRED BY ARTICLE 445 OF NATIONAL ELECTRICAL CODE. IN PARTICULAR THE AMBIENT TEMPERATURE RATING MUST BE SUBMITTED.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Lifesaving
Issued 2 July 1997
Resolved
REPLENISH OR REPLACE FIRST AID KIT TO BRING INTO COMPLIANCE WITH 46CFR160.041.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Electrical
Issued 2 July 1997
Resolved
PROVIDE ONE ADDITIONAL FLASHLIGHT FOR EMERGENCY LIGHTING, TO BE LOCATED IN VICINITY OF MACHINERY SPACE.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Lifesaving
Issued 2 July 1997
Resolved
PROPERLY MARK LOCATION OF CHILD LIFEJACKETS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Lifesaving
Issued 2 July 1997
Resolved
INSTALL 3 TO 6 FOOT LANYARD WITH DETACHABLE CLIP ON RING BUOY LIGHT.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Documentation
Issued 2 July 1997
Resolved
PROVIDE ADEQUATE NUMBER OF MARPOL V PLACARDS ONBOARD THE VESSEL.
Condition: Unknown
Due 2 July 1997
Resolved 2 July 1997
Fire Fighting
Issued 27 June 1995
Resolved
The stbd side, engineroom, dry chemical, portable fire extinguisher (type B-II) requires hydrostatic testing. Hydrostatically test this extinguisherto the satisfaction of the cognizant OCMI prior to 27JUL95.
Condition: Unknown
Due 27 June 1995
Resolved 27 June 1995
Electrical
Issued 26 October 1993
Resolved
PROVIDE PLANS FOR PROPER INSTALLATION OF SHORE TIE POWER ELECTRICAL SYSTEM.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 26 October 1993
Resolved
REMOVE ALL NON-MARINE PORTABLE WIRING AND SHORE TYPE ELECTRIC EXTENSION CORDS.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 26 October 1993
Resolved
PROVIDE ELECTRICAL DRAWING FOR PROPER GENERATOR INSTALLATION, GENERATOR SHALL BE PERMANENTLY DISCONNECTED OR REMOVED FROM VESSEL UNTIL PLAN APPROVAL.
Condition: Unknown
Due 26 October 1993
Resolved 26 October 1993
Electrical
Issued 8 June 1993
Resolved
PROVIDE COPY OF APPROVED ELECTRICAL DRAWINGS FOR GENERATOR INSTALLATION.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Lifesaving
Issued 8 June 1993
Resolved
REPLACE 3 OUTDATED ORANGE FLARES AND 6 RED FLARES.
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Accommodation/Occupational Safety
Issued 29 June 1992
Resolved
PROVIDE LABELS FOR ALL EMERGENCY EXITS AT LEAST ONE (1) INCH HIGH LETTERS.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Electrical
Issued 29 June 1992
Resolved
PROVIDE COVERS FOR LIGHT BULBS IN ENGINE ROOM.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Lifesaving
Issued 29 June 1992
Resolved
PROVIDE ONE (1) WHITE OR ORANGE 24" RING BUOY.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Engineering
Issued 29 June 1992
Resolved
PROVIDE EXHAUST VENTILATION FOR ENGINE COMPARTMENT. THE DUCTING IS TO BE FIRE PROOF AND EXTEND CLOSE TO THE BILGE. THE AREA IS TO BE AT LEAST 15 SQUARE INCHES.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Engineering
Issued 29 June 1992
Resolved
PUT ONE (1) INCH LETTERS FOR FUEL TANK VALVES ON THE OUTSIDE OF THE COMPARTMENT.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Lifesaving
Issued 29 June 1992
Resolved
EITHER CHANGE THE NAME OF THE VESSEL AT THE DOCUMENTATION OFFICE OR PUT THEVESSEL NAME "ROSE" ON ALL LIFESAVING EQUIPMENT AND HULL.
Condition: Unknown
Due 29 June 1992
Resolved 29 June 1992
Lifesaving
Issued 2 July 1991
Resolved
STENCIL NAME OF VESSEL ON RING LIFE BUOY.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Fire Fighting
Issued 2 July 1991
Resolved
PROVIDE MOUNTING BRACKETS FOR FIRE EXTINGUISHERS IN ENGINE ROOM.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Lifesaving
Issued 2 July 1991
Resolved
PROVIDE THREE (3) ADDITIONAL ORANGE SMOKE FLARES.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Fire Fighting
Issued 2 July 1991
Resolved
PROVIDE PROOF OF SERVICING OF ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 July 1991
Resolved 2 July 1991
Fire Fighting
Issued 13 July 1989
Resolved
PROVIDE AND MOUNT APPROVED BRACKETS FOR THE TWO BII RATED FIRE EXTINGUISHERS IN THE ENGINE ROOM.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Engineering
Issued 28 July 1988
Resolved
PROVIDE FLAME IMPINGMENT BOWL FOR GLASS RACOR FUEL FILTER.
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Engineering
Issued 28 July 1988
Resolved
PROVIDE FUEL SHUTOFFS FOR FUEL TANKS. IAW 46CFR 182.20-40(B)(3)
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Construction/Loadline
Issued 28 July 1988
Resolved
PROVIDE FIXED BILGE PUMP WITH MINIMUM CAPACITY OF TEN GALLONS PER MINUTE, WITH RIGID SUCTION LINE OF AT LEAST ONE INCH DIAMETER AND A CHECK VALVE AT SOME ACCESSIBLE POINT IN THE LINE. IAW 46CFR 182.25-5
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Electrical
Issued 28 July 1988
Resolved
REPAIR EXPOSED WIRING AND UNAPPROVED SPLICES. IAW 46CFR 183.05-50(B)
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988
Unknown
Issued 28 July 1988
Resolved
PROVIDE AND POST EMERGENCY CHECKLIST. 46CFR 185.25-1(A)
Condition: Unknown
Due 28 July 1988
Resolved 28 July 1988