MAURY USCG vessel records Sign in
← All vessels

MAHARSHI DATTATREYA

MAHARSHI DATTATREYA is a 1983 tank ship. The Coast Guard has recorded 40 inspections since 1985, most recently in September 2003, along with 20 deficiencies and 7 operational controls.

Records from 1985 to 2003. Most recent: inspection, 2 September 2003.

Built
1983
Last inspected
2 September 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8128975 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
INDIA
—
Maury page id
psix-55330

Inspections, by type

…with no type recorded23
Years with a record 8 calendar years (1985–2003)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6877 - Regulatory (Subpart C or D), Net Ton
15709 - Regulatory (Subpart C or D), Gross Ton
24470 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

2 September 2003 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1890918
5 April 2003 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1830955
27 January 2003 Security Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1735891
21 January 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1734618
27 December 2002 Security Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1730187
11 December 2002 Certificate of Compliance
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1717911
22 November 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1709492
1 November 2002 Security Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1706865
16 September 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1676442
28 August 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1668298
28 August 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1671648
10 August 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1659410
1 August 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1655197
25 July 2002 Deficiency Check · Security Inspection · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1651855
13 July 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1653765
30 June 2002 Examination of Repairs · Security Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1638936
13 June 2002 Security Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1630806
30 May 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1632503
15 May 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1633676
30 April 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1633957
7 April 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1602064
26 March 2002 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1597914
14 March 2002 Security Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1493826
1 March 2002 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1491353
28 February 2002 Type not recorded
No type recorded · Station Sabine · USCG Heartland District (CGD-H) · Activity 1497001
28 May 1998 Type not recorded
No type recorded · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 418195
28 May 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1129577
19 June 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 379579
1 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 370007
1 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1174797
24 July 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 369561
24 July 1994 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 865825
2 July 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 368017
2 July 1994 MARPOL Annex I Examination · Letter of Compliance (Initial/Renewal)
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354989
13 February 1991 Certificate of Compliance
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 907227
12 February 1991 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 341758
8 September 1986 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 520343
8 August 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 456640
8 August 1986 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 530994
30 July 1985 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 520997

Deficiency record · 20

Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 11 December 2002 Resolved
Properly stow CO2 bottles in CO2 room in accordance with Class approved CO2 system drawings. LEGACY COMPONENT DESC: Tanks
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 January 2003
Resolved 27 January 2003
Resolution: Witnessed by HIV boarding officer.
Lifesaving › Launching Appliances
Issued 11 December 2002 Resolved
Replace wire on port and starboard side liferaft davits. LEGACY COMPONENT DESC: Lines
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2003
Resolved 27 January 2003
Resolution: Witnessed by HIV boarding officer.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 31 August 2002 Resolved
Significant air leak from the Main Engine control air pressure reducing valve. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 September 2002
Resolved 2 September 2002
Resolution: Received a report from DNV class stating that the pressure reducing valve was repaired and tested to 30 bar. Vessel restriction rescinded.
Engineering › Diesel Engine (auxiliary)
Issued 16 July 2002 Resolved
SPRAYING LUBE OIL LEAK ON THE NO.3 GENERATOR'S GOVERNOR. LEGACY COMPONENT DESC: Governor
Condition: Unknown
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 19 July 2002
Resolution: Received class report from DNV stating the governor wear ring and axle journal were replaced and the engine was tested under load with no leaks noted.
Engineering › Diesel Engine (auxiliary)
Issued 16 July 2002 Resolved
EXCESSIVE FUEL OIL LEAKS ON THE NO.1 GENERATOR'S FUEL OIL PUMPS. LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2002
Resolved 17 July 2002
Resolution: Received class report from DNV stating all leaks have been repaired.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 30 June 2002 Resolved
Fractured cargo pipe in compressor room was leaking anhydrous ammonia into the space. Temp repairs were carried out to the satisfaction of class and USCG. Prior to next full discharge of cargo in the U.S., vessel must make permanent repairs to piping and leaks in compressor room. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2002
Resolution: CG Inspector reviewed class report issued by DNV in Caracas and viewed repairs all sat.
Navigation › Piloting/Steering
Issued 14 March 2002 Resolved
Gyrocompass reading variance of 3-9 off true heading. LOD issued by Captain of the Port. LEGACY COMPONENT DESC: Gyro Compass
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2002
Resolution: Received sat tech report attesting proper gyro operation.
Deck/Cargo
Issued 2 July 1994 Resolved
Ensure all alarms and shutdowns associated with proper operation of Inert Gas Generator are demonstrated to attending marine inspector prior to cargohandling in next U.S. port.
Condition: Unknown
Due 2 August 1994
Resolved 2 November 1994
Fire Fighting
Issued 2 July 1994 Resolved
Repair as original fire main piping on maindeck in way of three soft patches noted during inspection.
Condition: Unknown
Due 2 August 1994
Resolved 2 November 1994
Deck/Cargo
Issued 12 February 1991 Resolved
VSL MUST REPLACE DILUTION FLOW METER INSIDE THE GAS DETECTOR IN THE CARGO CONTROL ROOM.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Deck/Cargo
Issued 12 February 1991 Resolved
VSL MUST PROVIDE EVIDENCE TO RELIEF VALVE SETTINGS FOR THE INTER _x001C_ BARRIER SPACES.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Deck/Cargo
Issued 12 February 1991 Resolved
VSL MUST REPAIR & MAKE OPERABLE THE 95% FULL ALARM FOR NO 2_x001C_ PORT CARGO TANK.
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Navigation
Issued 12 February 1991 Resolved
VSL HAS NO OPERATING INSTRUCTIONS FOR STEERING GEAR CHANGE-OVER _x001C_ AS REQUIRED IN 33 CFR 164.35(k)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 February 1991
Resolved 12 February 1991
Navigation
Issued 12 February 1991 Resolved
VSL MISSING ARPA LABEL & INFORMATION AS REQUIRED IN 33 CFR 164.38(d)(1)(i)(ii).
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994
Deck/Cargo
Issued 12 February 1991 Resolved
VSL MISSING CONTAINMENT AFT FOR MANIFOLDS OF BUNKER & DIESEL LINES_x001C_ LOCATED PORT & STARBOARD AS REQUIRED IN 33 CFR 155.320(a)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Deck/Cargo
Issued 12 February 1991 Resolved
VSL MUST PROVIDE EVIDENCE AS TO THE MELTING POINT OF THE FUSIBLE_x001C_ ELEMENTS FOR SHUTDOWN SYSTEM.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Deck/Cargo
Issued 12 February 1991 Resolved
VSL MUST PROVIDE AN AUTO-CLOSURE FOR OUTER DOOR ON AIR LOCK FOR _x001C_ THE COMPRESSOR MOTOR ROOM.
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Deck/Cargo
Issued 12 February 1991 Resolved
VSL MUST PROVIDE AN ALARM FOR THE INERT GAS SYSTEM IN ACCORDANCE _x001C_ WITH 46 CFR 154.906(c).
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Documentation
Issued 12 February 1991 Resolved
VSL'S OTP ARE INSUFFICIENT, MISSING THE REQUIRED INFORMATION_x001C_ REQUIRED IN 33 CFR 155.750(a)(b)(2)(3)(c)(e)(f)(g)(h).
Condition: Unknown
Due 28 September 1994
Resolved 28 September 1994
Lifesaving
Issued 12 February 1991 Resolved
PRIOR TO CARRIAGE OF CARGO'S LISTED IN TABLE 4 OF 46 CFR 154_x001C_ (I OR I & T CARGO'S) VSL MUST PROVIDE THE PROPER PORTABLE GAS DETECTORS_x001C_ REQUIRED IN 46 CFR 154.1345.
Condition: Unknown
Due 27 September 1994
Resolved 27 September 1994

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.