MAURY USCG vessel records Sign in
← All vessels

O'NEIL TIDE

O'NEIL TIDE is a 1983 offshore supply vessel. The Coast Guard has recorded 34 inspections since 1983, most recently in October 2008, along with 12 deficiencies and 1 casualty investigation in 2009.

Records from 1983 to 2009. Most recent: casualty investigation, 15 August 2009.

Built
1983
Last inspected
29 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8216526 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WRC5791
Flag
MEXICO
—
Maury page id
psix-55339

Inspections, by type

…with no type recorded9
Years with a record 20 calendar years (1983–2008)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it225 - Convention (Subpart B), Net Ton
202 - Regulatory (Subpart C or D), Net Ton
750 - Convention (Subpart B), Gross Ton
298 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WRC5791MMSI not assigned · cancelled · compulsorily equipped · granted 22 May 1998, cancelled 3 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 34

29 October 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3353645
11 July 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1067677
30 January 2001 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423502
10 October 2000 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1430931
2 October 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054635
26 October 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1048044
9 October 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802122
8 October 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465422
7 October 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375150
11 October 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377838
7 May 1996 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1082432
1 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405882
29 January 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 761615
23 January 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1432999
3 January 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 194932
12 December 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1383108
18 October 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458193
18 August 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449629
13 November 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468278
12 September 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1257077
11 January 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224412
16 October 1990 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1216820
20 September 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 892172
1 August 1988 Damage Survey · Deficiency Check · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344205
14 July 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1342019
13 July 1988 Re-Inspection · MARPOL Annex II Examination · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1033177
22 September 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1011523
24 February 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324238
16 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299635
30 January 1986 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997197
3 October 1985 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 997988
27 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976568
26 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282312
6 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277455

Deficiency record · 12

Navigation
Issued 10 October 2000 Resolved
Provide double-nut securing for rudder stocks (2).
Condition: Unknown
Due 10 October 2000
Resolved 10 October 2000
Engineering
Issued 10 October 2000 Resolved
Provide double-nut securing for shaft packing flanges (2).
Condition: Unknown
Due 10 October 2000
Resolved 10 October 2000
Engineering
Issued 10 October 2000 Resolved
Provide copy of test results report of engineering automation system.
Condition: Unknown
Due 10 October 2000
Resolved 10 October 2000
Electrical
Issued 10 October 2000 Resolved
Provide verification of proper operation of overspeed trips to port/stbd SSGs.
Condition: Unknown
Due 10 October 2000
Resolved 10 October 2000
Engineering
Issued 12 December 1995 Resolved
PROVIDE RELIEF VALVE ON DISCHARGE SIDE OF BOTH COMPRESSORS OR DEMONSTRATE THAT COMPRESSORS CANNOT PRODUCE PRESSURES EXCEEDING RATING OF ALL PIPING & FIXTURES ON DISCHARGE SIDE. INSTALLATION & TESTING TO BE TO SATISFACTION OFCOGNIZANT OCMI. (SEE 46 CFR 56.07-10(B)).
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Construction/Loadline
Issued 18 October 1994 Resolved
MAKE PERMANENT REPAIRS TO RUDDER ROOM WATER TIGHT DOOR TO THE SATISFACTION OF THE MARINE INSPECTOR. DOG WHEEL WILL NOT ENGAGE DUE TO EXCESSIVE WEAR.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Accommodation/Occupational Safety
Issued 18 October 1994 Resolved
REDUCE PAC'S TO 9 UNTIL UPPER DECK ACCOMODATION IS ACCEPTABLE TO MARINE INSPECTOR. TWO RACKS BROKEN; MISSING TWO LOCKERS FOR CREW PERSONAL EFFECTS.
Condition: Unknown
Due 31 October 1994
Resolved 31 October 1994
Unknown
Issued 14 July 1988 Resolved
NOTIFY [name withheld], TEXAS PRIOR TO DEPARTING CAMERON, LOUISIANA THE NAME AND LOCATION OF SHIPYARD THAT IS TO CONDUCT REPAIRS TO THE VESSEL'S BOW SECTION.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
UPON RECEIVING PERMISSION FROM [name withheld], TEXAS, PROCEED FROM CAMERON, LOUISIANA ON THE INTRACOASTAL WATERWAY DURING DAYLIGHT HOURS ONLY.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Unknown
Issued 14 July 1988 Resolved
THE GYRO AND MAGNETIC COMPASS AUTO PILOT SYSTEM IS TO BE CHECKED BY A COMPETENT AUTHORITY AND PROVIDE THE TEST RESULTS TO THE [name withheld], TEXAS.
Condition: Unknown
Due 14 July 1988
Resolved 14 July 1988
Fire Fighting
Issued 16 May 1986 Resolved
CONDUCT HYDROSTATIC TEST OF INSTALLATED FIRE MONITOR PIPING AND DEMONSTRATESATISFACTORY OPERATION OF INSTALLATION.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Deck/Cargo
Issued 16 May 1986 Resolved
PRIOR TO PLACING THE TOWING WINCH IN SERVICE AND NO LATER THAN 31DEC86, HAVE THE NEW TOWING WINCH INSTALLATION EXAMINED BY A U. S. COAST GUARD MARINE INSPECTOR AND PROVIDE A COPY TO THE VESSEL OF THE NEW STABILITY LETTER AND BOOKLETS.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986

Casualty record · 1

15 August 2009Routine · role: Moored/Anchored in Vicinity of Primary Subject · activity 3568577
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.