This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
58 - Regulatory (Subpart C or D), Gross Ton
39 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-55357
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. Only barges and towing
vessels are in this archive, so any other vessel type in the same activity does not
appear here: these lists are a floor, not a complete manifest.
Echo Depth Sounding device not on board as required under 33 CFR 164.72 (a)(5)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Personnel › Training › Fire Fighting Basic
Issued 30 April 2007Resolved
Fire Fighting Crew Training Requirements not conducted as required under 46 CFR 27.209.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2007
Resolved 30 April 2007
Resolution: Conducted Fire Fighting Drill in presence of CG Inspector.
Communications › Alarms/Indicators › General Alarm
Issued 30 April 2007Resolved
General Alarm placard missing in Machinery space and needs flashing RED light (presently white) in machinery space as required under 46 CFR 27.201(a)(3).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Fire Fighting › Fixed Fire Detection System › Approval
Issued 30 April 2007Resolved
Provide proof Fire Detection System is Certified by a Professional Engineer or Classification Society as required under 46 CFR 27.203(g).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 24 May 2007
Resolution: Recieved report from vessel operator. Report was from Certified Professional Engineer.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 30 April 2007Resolved
Provide proof or exhibit to the attending Coast Guard Marine Inspector that the Fire Detection System operates according to the requirements listed under 46 CFR 27.203.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 30 April 2007Resolved
Flame Screens needed for both fuel tank vents as required under 46 CFR 27.21(d)(1).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 April 2007Resolved
Batteries in machinery space need post covers or placement in covered battery boxes (good marine practice).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 April 2007Resolved
Cover needed on electric fire pump switch and outlet box above work bench in machinery space. (Good Marine Practice)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 30 April 2007Resolved
Fixed Fire Pump must be energized remotely from safe place outside engine room as required under 46 CFR 27.301 (a)(3).
OR
Portable Fire Pump on board meets Coast Guard requirements under 46 CFR 27.301(e).
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 3 May 2007
Resolution: Portable fire pump inspected and charged to the satisfaction of the CG inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 April 2007Resolved
Remote Fuel Oil Shutoff not labeled with operating instructions as required under 46 CFR 27.207.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 3 May 2007
Resolution: Remote Fuel Oil Shutoff now labeled with operating instructions.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 25 October 2005
Resolution: Light repaired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 25 October 2005
Resolution: compass light operational