Records from 1991 to 2023. Most recent: inspection, 3 April 2023.
Inspection history · 26
3 April 2023
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7661981
21 August 2013
MARPOL · Risk-based Targeted Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4778137
24 July 2012
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4389368
24 July 2012
Type not recorded
No type recorded · Station Rochester · USCG Great Lakes District (CGD-GL) · Activity 4389597
20 June 2012
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4350190
20 June 2012
Type not recorded
No type recorded · Station Alexandria Bay · USCG Great Lakes District (CGD-GL) · Activity 4350565
10 May 2012
Spot Check (Safety)
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4308168
3 October 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4160461
3 October 2011
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 4162178
8 December 2010
Spot Check (Safety)
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3911299
6 February 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3142740
19 June 2007
Deficiency Check
Physical examination · Sector Field Office Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2966897
30 April 2007
Uninspected Other
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2921314
29 December 2006
Administrative Inspection
Administrative · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2847779
31 May 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2666286
25 October 2005
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2522387
18 August 2005
Uninspected Other
Physical examination · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2466962
2 February 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1999969
2 October 2003
Type not recorded
No type recorded · Marine Safety Detachment Grand Haven · USCG Great Lakes District (CGD-GL) · Activity 2147843
21 June 1993
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 660612
25 May 1993
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 17185
25 May 1993
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 134397
6 June 1992
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 660613
25 April 1992
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 81649
23 December 1991
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 674166
16 December 1991
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 674165
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 30 April 2007
Resolved
Current copy of COD not on board as required under 46 CFR 67.313(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 30 April 2007
Resolved
Vessel log of required tests and inspections not on board as required under 33 CFR 164.78(b) & 33 CFR 164.80(a).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 30 April 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 30 April 2007
Resolved
Coast Guard Local Notice To Mariners not in board as required under 33 CFR 164.72(b)(2).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Navigation › Collision/Grounding Avoidance › Searchlight
Issued 30 April 2007
Resolved
Port side searchlight not working as required under 33 CFR 164.72(a)(2).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 30 April 2007
Resolved
Magnetic Compass not illuminated as required under 3 CFR 164.72(a)(4).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 30 April 2007
Resolved
Echo Depth Sounding device not on board as required under 33 CFR 164.72 (a)(5)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Personnel › Training › Fire Fighting Basic
Issued 30 April 2007
Resolved
Fire Fighting Crew Training Requirements not conducted as required under 46 CFR 27.209.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 May 2007
Resolved 30 April 2007
Resolution: Conducted Fire Fighting Drill in presence of CG Inspector.
Communications › Alarms/Indicators › General Alarm
Issued 30 April 2007
Resolved
General Alarm placard missing in Machinery space and needs flashing RED light (presently white) in machinery space as required under 46 CFR 27.201(a)(3).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Fire Fighting › Fixed Fire Detection System › Approval
Issued 30 April 2007
Resolved
Provide proof Fire Detection System is Certified by a Professional Engineer or Classification Society as required under 46 CFR 27.203(g).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 24 May 2007
Resolution: Recieved report from vessel operator. Report was from Certified Professional Engineer.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 30 April 2007
Resolved
Provide proof or exhibit to the attending Coast Guard Marine Inspector that the Fire Detection System operates according to the requirements listed under 46 CFR 27.203.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 30 April 2007
Resolved
Flame Screens needed for both fuel tank vents as required under 46 CFR 27.21(d)(1).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 April 2007
Resolved
Batteries in machinery space need post covers or placement in covered battery boxes (good marine practice).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 30 April 2007
Resolved
Cover needed on electric fire pump switch and outlet box above work bench in machinery space. (Good Marine Practice)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 25 May 2007
Fire Fighting › Fire Pumps › Arrangement
Issued 30 April 2007
Resolved
Fixed Fire Pump must be energized remotely from safe place outside engine room as required under 46 CFR 27.301 (a)(3).
OR
Portable Fire Pump on board meets Coast Guard requirements under 46 CFR 27.301(e).
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2007
Resolved 3 May 2007
Resolution: Portable fire pump inspected and charged to the satisfaction of the CG inspector.
Fire Fighting › Remote Fuel Shutoff › General
Issued 30 April 2007
Resolved
Remote Fuel Oil Shutoff not labeled with operating instructions as required under 46 CFR 27.207.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 May 2007
Resolved 3 May 2007
Resolution: Remote Fuel Oil Shutoff now labeled with operating instructions.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 August 2005
Resolved
Mast head light bulb missing. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 25 October 2005
Resolution: Light repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 August 2005
Resolved
Compass light out. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2005
Resolved 25 October 2005
Resolution: compass light operational