Records from 1997 to 2026. Most recent: inspection, 23 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 48
23 April 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8354942
2 June 2025
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8212972
24 April 2025
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8126645
15 January 2025
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8063871
24 October 2024
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8024328
2 July 2024
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7947158
18 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7937530
11 April 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7896683
6 April 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7667270
15 August 2022
Internal Structural Exam · Hull Examination · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7534381
11 August 2022
Drydock Exam · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7530650
7 April 2022
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7464234
8 April 2021
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7171231
2 July 2020
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6901920
1 June 2020
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6965527
11 June 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6710843
11 April 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6664346
12 April 2018
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6397727
8 June 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6169777
13 April 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6133200
18 April 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5899741
3 November 2015
In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5756671
9 June 2014
Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4905628
6 June 2012
Hull Examination · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4342670
6 September 2011
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4137455
26 March 2010
DAPI Audit
Administrative · USCG East District (dp) · USCG East District (CGD-E) · Activity 3711908
27 April 2009
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3462288
27 April 2008
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3197286
30 April 2007
Annual Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2944864
20 April 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2632421
13 June 2005
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2396681
29 April 2005
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2345843
29 April 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2055498
11 June 2003
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1814690
1 May 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1809774
13 May 2002
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1614594
5 June 2001
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1362252
23 April 2001
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1062184
13 April 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1397624
2 May 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1457804
28 April 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 794361
28 April 1999
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 802721
12 January 1999
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1029016
14 December 1998
Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 808637
27 November 1998
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 805905
1 May 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 792691
19 March 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1445331
20 March 1997
Initial Certification · Hull Examination · Plan Review "T" Boat
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1416252
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 April 2026
Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This fire pump shall be equipped with suction and discharge hose suitable for use in fire fighting. Vessel did not have a hand operated portable fire pump on board.
46CFR181.10-5(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 May 2026
Resolution: Received photo of portable hand fire pump on board.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 23 April 2026
Resolved
As appropriate for the intended voyage,all vessels must carry adequate and up-to-date-(a) Charts;(b) Sailing directions;(c) Coast pilots;(d) Light lists. There were no up to date charts on board.
46CFR185.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2026
Resolution: New charts on board.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 April 2026
Resolved
Each water light must be of an approved automatic electric type. The life ring buoy water light has an expired battery. Vessel is restricted to daytime operations only.
46CFR180.30-1(b)
Action required: 705 - Other - as specified
Resolved 28 April 2026
Resolution: Photo received of new new battery for water light. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 23 April 2026
No resolution recorded
Attached to the life float or buoyant apparatus by a 12 thread manila or equivalent synthetic lanyard, at least
5.5 meters (18 feet) in length. When stowed in tiers, the separate units must be kept apart by spacers. Water light lanyard was not 18', there were no spacers in between the life floats. There were multiple punctures on both life floats as well as some delamination.
46CFR180.20-1
Action required: 50 - Rectify deficiencies w/in 30 days
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 11 April 2024
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. The FCC-licensed technician must use the latest FCC Information Bulletin, How to Conduct an Inspection of a Small Passenger Vessel. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The vessel's safety cert was past its due date.
47CFR 80.903
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 May 2024
Resolved 24 May 2024
Resolution: Vessel has new FCC Safety Cert.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 6 April 2023
Resolved
46 CFR 185.520 - Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. Vessel could not produce any records of drills or training.
Action required: 10 - Deficiency Rectified
Resolved 12 April 2023
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 August 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel missed Dry Dock exam on 30 June 2022. Vessel is not authorized to carry passengers until dry dock exam is completed. 46 CFR 176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 August 2022
Resolution: Completed successful DDX
Construction/Loadline › Hull › Side Shell
Issued 6 June 2012
Resolved
Two holes located on port bow approx 2" above keel. Grind out all wasted wood and fill to original condition.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 7 June 2012
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Construction/Loadline › Hull › Keel Plate
Issued 6 June 2012
Resolved
Worm shoe at bow wasted. Complete temp repair until November hall out and replace affected worm shoe with new.
Action required: 705 - Other - as specified
Due 13 June 2012
Resolved 7 June 2012
Resolution: Corrected to the satisfaction of attending USCG Marine Inspector.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 26 March 2010
Resolved
Company has no record of completed background checks on safety sensitive employees who worked in the marine industry.
Due 6 April 2010
Resolved 6 April 2010
Resolution: Background check completed as needed for new crew member.
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 26 March 2010
Resolved
Employer needs to have a way to test incase of serious incident testing.
Due 6 April 2010
Resolved 6 April 2010
Resolution: Employer has a way to be tested without having to maintain testing kits on vessel.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 26 March 2010
Resolved
Employer needs to file the annual MIS report information is provided by Health Enhancement Consortium.
Due 6 April 2010
Resolved 6 April 2010
Resolution: Employer has filed MIS for last year 2009.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 April 2006
Resolved
Service one portable FE.
Due 20 April 2006
Resolved 12 May 2006
Resolution: Serviced.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 April 2006
Resolved
Show proof of valid COD
Due 20 May 2006
Resolved 12 May 2006
Resolution: new document
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 April 2006
Resolved
Post COI and stability ltr.
Due 20 May 2006
Resolved 12 May 2006
Resolution: Posted
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 20 April 2006
Resolved
Provide current US Coast Pilot.
Due 20 May 2006
Resolved 12 May 2006
Resolution: New Coast pilot.
Communications › Alarms/Indicators › Bilge Alarm
Issued 20 April 2006
Resolved
Show operation of high water audible alarm.
Due 20 April 2006
Resolved 12 May 2006
Resolution: Alarm working
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 20 April 2006
Resolved
Stencil vessel name on ring buoy.
Due 20 May 2006
Resolved 12 May 2006
Resolution: vessel name on buoy
Documentation › Certificates/Documents
Issued 13 May 2002
Resolved
PROVIDE UP TO DATE COPY OF COAST PILOT.
Due 13 June 2002
Resolved 12 June 2002
Lifesaving › Buoyant Apparatus
Issued 13 May 2002
Resolved
RENEW/REPAIR WATER LIGHT FOR LIFE FLOAT. VSL IS RESTRICTED TO DAYLIGHT OPERATIONS ON CERTIFICATE OF INSPECTION.
Due 22 May 2002
Resolved 12 June 2002
Communications › Alarms/Indicators
Issued 13 May 2002
Resolved
PROVIDE VISUAL INDICATING LIGHT FOR HIGH WATER ALARM. LEGACY COMPONENT DESC: High Water Alarm
Due 13 June 2002
Resolved 12 June 2002
Construction/Loadline
Issued 13 April 2001
Resolved
REPAIR PORT SIDE WASH BOARD ON PUSH BOAT.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Engineering
Issued 13 April 2001
Resolved
PROVIDE SAE J 1942 FUEL HOSE FOR RUNS OVER 30 INCHES.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Construction/Loadline
Issued 13 April 2001
Resolved
REPAIR HIGH WATER BILGE ALARM.
Condition: Unknown
Due 13 April 2001
Resolved 13 April 2001
Accommodation/Occupational Safety
Issued 2 May 2000
Resolved
REPAIR PORT CABIN WINDOW.
Condition: Unknown
Due 2 May 2000
Resolved 2 May 2000
Navigation
Issued 19 March 1998
Resolved
Provide tide & current tables.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Engineering
Issued 19 March 1998
Resolved
Replace alternator on push boat with a marine type. This requriement was not issued during the RIN due to inspector oversight. Requirement issued via phone and fax.
Condition: Unknown
Due 19 March 1998
Resolved 19 March 1998
Fire Fighting
Issued 19 March 1998
Resolved
Provide approved B-II portable.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Navigation
Issued 19 March 1998
Resolved
Replace comapss.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Electrical
Issued 19 March 1998
Resolved
Provide enclsoure for aquariam seitch.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998
Documentation
Issued 19 March 1998
Resolved
Provide evide3nce of drug testing in form of list of persons enrolled & reporting requirements letter.
Condition: Unknown
Due 7 April 1998
Resolved 7 April 1998